Antari DNG-250 Low Fog Generator

User Manual

Brand: Antari

Model: DNG-250

Introduction

Thank you for choosing Antari's DNG-250 Low Fog Generator. This machine features a 3.5 TFT color touch panel for easier operation. It offers increased output volume and continuity compared to its predecessor, the DNG-200, with no CO2 required, making it an environmentally friendly effect machine.

Please follow these operation, safety, and maintenance instructions to ensure a long and safe life for your DNG-250 Low Fog Generator. Pay attention to all warning labels and instructions printed on the exterior of the machine.

Safety Instructions

If you have questions about operating the machine safely, please contact your local Antari dealer.

Unpacking and Inspection

Open the shipping carton and verify that all necessary equipment is present and intact. If any items are missing or damaged due to transportation, contact your Antari dealer and return the product with original packaging for inspection. The shipping carton should contain:

Setup

The wheels at the bottom of the DNG-250 aid in mobility. Wheel fixing mechanisms are located diagonally. Position the machine and press down the fixing mechanism to prevent movement. To move the machine, press the opposite side of the mechanism to release it. Note: The machine should not be placed on a slope due to its size.

Figure 1: Diagram showing the wheels and their fixing mechanisms on the bottom of the machine.

Aim the key on the PowerCon terminal of the power cord towards the slot on the machine's connector. Plug it in and turn approximately 10° clockwise until the cord is securely fixed. The upper power cord is for the fog generator, and the bottom one is for the compressor.

Figures 2 & 3: Diagrams illustrating the connection of the PowerCon power cords to the rear panel of the machine, showing the locking mechanism and the two distinct power inputs.

Before connecting to power, verify the required voltage and wattage indicated on the machine's metal plate.

Connect the machine with the black fog conducting hose. This is a three-meter pipe that can be adjusted to the required length.

Figure 4: Image showing the flexible black fog conducting hose attached to the front of the DNG-250.

Fill the tank with Antari FLL Low Fog Effects Fluid and tighten the tank cap.

Figure 5: Image of a bottle of Antari FLL Low Fog Effects Fluid.

Operation

1. After confirming the voltage, connect the power cord to a grounded outlet. Turn on the lower power switch first, then the higher one. The warmup process begins, and the TFT touch panel will display the warmup progress percentage until 100% is reached.

TFT Touch Panel Introduction

The TFT touch panel provides intuitive control over the DNG-250.

Main Menu

The main screen displays:

Manual Mode

In Manual Mode, you can directly control fog output and fan speed.

Manual Mode Setting

This sub-menu allows fine-tuning of manual fogging:

Timer Mode

Timer Mode allows for automated fogging sequences.

Timer Mode Setting

Configure the timer parameters:

DMX

The DMX interface allows integration with lighting control systems.

DMX Setting

Configure the DMX address using the on-screen numeric keypad. Enter the desired address number and press Confirm.

Diagram showing a numeric keypad for DMX address input, with 'Cancel' (❌) and 'Confirm' (✔️) buttons.

Enforceable Fluid Drawing

Use this function to draw fluid when the tank is refilled or if the pump struggles. Press "Pause" once the output is back to prevent excessive dampness. The default duration is 1 minute.

Diagrams showing the 'Enforceable Fluid Drawing' screen in 'Start' mode and 'Pause' mode with a countdown timer.

Heater

The heater can be activated or deactivated manually. The default setting is activated upon power-on.

Diagrams showing the 'Heater Activated' and 'Heater Deactivated' screens.

Main Menu

Access various settings and information from the main menu:

DMX Connector Pin Assignment & Instruction

DMX Connector Pin Assignment

The machine provides 3-pin and 5-pin XLR connectors for DMX connection. The diagrams indicate pin assignment information.

Pin Function
1 Grounding
2 Data -
3 Data +

Diagrams showing 3-pin and 5-pin XLR connectors with pin numbering.

DNG-250 DMX Instruction

The DNG-250 low fog generator has built-in DMX 512 functionality with 3-pin and 5-pin sockets. After connecting to DMX, the TFT touch panel cannot be used for operation; all actions are controlled by DMX. Only the DMX address can be entered via the TFT touch panel.

DMX 512 Settings

Function Figures Meaning
Output Volume 0 - 4 Off
5 - 255 20 - 100%
Output Fan 0 - 4 Off
5 - 255 20 - 100%

RDM Function

RDM (Remote Device Management) Function

The DNG-250 is equipped with RDM function, allowing users to control the unit through devices supporting the RDM ANSI E1.20 protocol. This protocol enhancement enables bi-directional communication between a controller and RDM-compliant devices over a standard DMX line. Users can set, monitor, and manage RDM-supported devices and equipment within a DMX network.

RDM Directory

The RDM directory lists available PIDs (Parameter IDs) and their capabilities.

RDM PID Value GET Allowed SET Allowed
DISC_UNIQUE_BRANCH0x0001
DISC_MUTE0x0002
DISC_UN_MUTE0x0003
STATUS_MESSAGE0x0030O
SUPPORTED_PARAMETERS0x0050O
*PARAMETER DESCRIPTION0x0051O
DEVICE_INFO0x0060O
PRODUCT_DETAIL_ID_LIST0x0070O
DEVICE_MODEL_DESCRIPTION0x0080O
MANUFACTURER_LABEL0x0081O
DEVICE_LABEL0x0082OO
LANGUAGE_CAPABILITIES0x00A0O
LANGUAGE0x00B0OO
SOFTWARE_VERSION_LABEL0x00C0O
DMX_PERSONALITY0x00E0OO
DMX_PERSONALITY_DESCRIPTION0x00E1O
DMX_START_ADDRESS0x00F0OO
SENSOR_DEFINITION0x0200O
SENSOR_VALUE0x0201O
DEVICE_HOURS0x0400O
IDENTIFY_DEVICE0x1000OO

Other Important Notes

Note 5-1: A water collection tray is equipped at the rear of the DNG-250. When the compressor runs, water drops may flow into the tray. Check the water level routinely and drain it to prevent overflow.

Figure 6: Image of the water collection tray at the rear of the DNG-250.

Note 5-2: For extended use or when unable to check the tray frequently, remove the tray and connect a 6mm PU hose to the water draining hole at the top of the collection tank to drain water directly. Push up the red button to remove the hose after draining.

Figure 7: Close-up of the water draining hole with a PU hose attached.

Note 5-3: The black square metal mesh at the back is the air inlet for the fan. Do not block it and clean it regularly.

Note 5-4: If fog volume is too low, the machine generates noise, or fog is not sprayed smoothly, turn off the power immediately. Check fluid level, external fuse, controller connection, or power supply. If issues persist, re-insert the power plug. If the machine still does not operate normally, check the hose to the fog fluid tank for blockages and fluid flow. If the cause cannot be identified, do not operate the machine to avoid damage. Turn off the machine, let it cool down, and contact an Antari dealer or service center. Do not disassemble the machine yourself.

Note 5-5: After prolonged use, residue may form on the floor, creating a slippery hazard. Be aware of floor material and ensure safety for people walking on it.

Note 5-6: The DNG-250 Low Fog Generator does not use dry ice; it is environmentally friendly and safe. However, the output fog is easily dispersed by wind. Consider the impact of fans or air conditioners on the fog effect.

Machine Maintenance Methods

6-1 Cleaning: Regular cleaning helps reduce replacement and repair costs.

6-2 Fluid Quality: Do not allow fog fluid to become contaminated. Keep the tank cap on at all times.

6-3 Storage Preparation: Before storing for extended periods, clean the machine, drain all fog fluid, disconnect the fog pipe and power cord. Store the machine and parts in the front accessory compartment. Warm up the machine once a month to prevent moisture buildup.

6-4 Storage Environment: Store the machine in a cool and dry place.

Technical Specifications

Specification Details
Input voltageUS model: AC 100-120V, 50/60Hz
EU model: AC 220-240V, 50/60Hz
Refrigerant120V R-404A, 1.76LB (0.8Kg)
240V R-404A, 1.76LB (0.8Kg)
Start current120V / 77.4A
240V / 36.1A
Rated power120V / 14.2A
240V / 6.5A
Fog power consumption120V / 1600W 13.5A
240V / 1600W 6.8A
Warm-up time6 minutes (approx.)
Fluid consumption100 ml / min (100% output)
Fluid tank capacity10 Liters (2.64 gallon)
Compatible fluidAntari FLL-10 Low Fog Effects Fluid
Ambient temp. range5°C ~ 40°C (41°F ~ 104°F)
Output120 m² / min
ControlManual, Timer, DMX 512
DMX Channels2 channels
ConnectionNeutrik Powercon (Power)
XLR 3-pin and 5-pin (DMX)
Optional AccessoriesFDNG-250 Flight Case
DimensionsL 780 W 608 H 715 mm
(L 30.7 W 23.93 H 28.15 inch)
Weight130 kg (286.6 lbs)

Please save this user manual carefully.

Spare Parts

The following parts are available for the DNG-250 Low Fog Generator:

Diagram showing an exploded view of the DNG-250 with numbered parts corresponding to the list above.

Models: DNG-250 Low Fog Generator, DNG-250, DNG-250 Fog Generator, Low Fog Generator, Fog Generator, Generator

File Info : application/pdf, 24 Pages, 1.28MB

PDF preview unavailable. Download the PDF instead.

C08DNG252DNG-250-中英文說明書-20210408 compressed

References

Microsoft Word 2016 iLovePDF

Related Documents

Preview Antari S-100X / S-200X Snow Machine User Manual and Technical Guide
Comprehensive user manual and technical specifications for Antari S-100X and S-200X snow machines, covering setup, operation, DMX control, maintenance, and safety.
Preview Antari FT-200 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-200 Fire Training Fog Machine. This guide covers essential safety information, unpacking and inspection, product overview, setup instructions, detailed operation modes (timer, volume, DMX, wireless), control panel functions, menu settings, fluid recommendations, maintenance procedures, breaker reset, and technical specifications.
Preview Antari AF-5X / AF-5XR Special Effects Fan User Manual
User manual for the Antari AF-5X and AF-5XR Special Effects Fans, detailing setup, operation, control panel functions, DMX and wireless control, safety information, and technical specifications.
Preview Antari FT-100 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-100 Fire Training Fog Machine, detailing setup, operation, safety precautions, maintenance, and technical specifications. Essential for fire training simulations.
Preview Antari MB-1 Mobile Fog Machine User Manual and Guide
Comprehensive user manual for the Antari MB-1 Mobile Fog Machine, covering setup, operation, safety, maintenance, and technical specifications. Learn how to use your MB-1 fogger effectively.
Preview Antari S-600 Yeti Snow Machine User Manual
Comprehensive user manual for the Antari S-600 Yeti Snow Machine, covering installation, operation, safety, technical specifications, and maintenance. Learn how to set up and use your snow machine effectively.
Preview Antari SW-250/SW-250X Snow Machine User Manual - High Output Wireless Control
Comprehensive user manual for the Antari SW-250 and SW-250X high output wireless snow machines. Covers setup, operation, remote control, DMX, maintenance, and technical specifications.
Preview Antari HZ-100 Haze Machine User Manual
Comprehensive user manual for the Antari HZ-100 Haze Machine, covering setup, operation, safety precautions, maintenance, technical specifications, and warranty information.