Antari S-600 Yeti Snow Machine User Manual
1. Introduction
Please read this user manual carefully before operating the machine. Keep this manual in a place where you can refer to it at any time. If you encountered any problems, please contact your local Antari dealer for advice and assistance.
2. Safety Information
⚠️ CAUTION!
Please read the following safety information carefully before operating the machine. This information includes important safeguards about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the machine.
⚡ DANGER! Electrical shock
Always connect the machine to correct voltage. It will lead to electrical shock or burns and may cause serious consequences if connecting to incorrect or improper voltage.
⚡ WARNING! Risk of electrocution
Always connect the machine to a protected circuit and ensure it is properly grounded to avoid risk of electrocution.
Damage caused by the disregard of this user manual is not subject to warranty. Antari and its dealer will not accept liability for any resulting defects or problems.
2.1 Installation
- Keep this device dry. This machine is not waterproof. Do not expose the machine to water splashes.
- Place the machine on a flat surface in a well-ventilated area. Provide at least 50 cm space around the machine.
- Make sure there are no flammable materials close to the machine while operating. Never add flammable liquid of any kind to the machine.
- Before connecting the machine to power, always check the voltage indicated on the machine matches your local AC voltage. Do not use the machine if AC power voltage does not match.
- If the supply cord is damaged, it must be replaced by a special cord or assembly available from your local Antari dealer for replacement.
- No user-serviceable or modifiable parts inside. Never try to repair this product; an unauthorized technician may lead the machine to damage or malfunction.
- This product is for indoor use only! Do not expose to rain or moisture. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, immediately unplug the machine and contact your local Antari dealer for advice.
- Pay attention to all warning labels and instructions on the machine before operation.
2.2 Operation
- Do not operate the machine with bundled power cables; it could be a fire hazard.
- Do not operate the machine in an area with unstable voltage, as this may burn out internal components and cause the machine to fail.
- Do not use the machine against humans, animals, or flames. Make sure there are no flammable materials close to the machine.
- For adult use only. The machine is not to be used by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge. Never leave the machine running unattended.
- Children should be supervised not to play with the machine.
- If you hear a strange sound or experience machine failure, stop use immediately. Turn off and unplug the machine, and contact your local Antari dealer for service.
- Turn off and unplug the machine when it is not in use.
- Make sure the machine is turned off before unplugging it.
- Do not use the machine upside down or tilted, as it may damage the machine and cause malfunction.
- Before transporting the machine, make sure the fluid tank is completely drained.
- Snow fluid may present health risks if swallowed. Do not drink snow fluid. Store it securely. In case of eye contact or if fluid is swallowed, immediately seek medical advice.
2.3 Grounding Instruction
This appliance must be grounded in the event of malfunction or breakdown. Grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120V circuit and has a grounding plug that looks like the plug illustrated in sketch A. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by the metal screw.
Diagram Description: Sketch A shows a standard three-prong plug and a grounded outlet. Sketch B shows a two-prong outlet with a temporary adapter connected, illustrating how the grounding means of the adapter connects to the outlet box cover. Sketch C shows the grounding means of the adapter.
3. Package Items
Immediately upon receiving the machine, carefully unpack the carton and check the contents to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retain the packing material for inspection.
3.1 Standard Package
- 1 x S-600 Snow Machine
- 1 x PowerCon True 1 Power Cord
- 1 x User Manual or scan QR code on technical label
- 1 x 5M Fluid Tank Feed Tube with Filter
- 1 x W-2 Wireless Transmitter (Receiver has been installed onto the machine)
- 1 x Hanging Bracket
3.2 Optional Accessories
| Item Code | Description |
|---|---|
| WTR-90 | W-2 & W-DMX Receiver & W-DMX-PCB |
| SC-4 | Cable Remote |
| S-600-BH | 5-Liter Bottle Holder |
4. Product Overview
The S-600 Yeti Snow Machine features the following components:
- 01. Control Panel: Interface for manual and timer operations.
- 02. Fluid Tube Connection: Port for connecting the fluid feed tube.
- 03. Main Power Switch: Turns the main power on/off.
- 04. True 1 PowerCon Connector: Power input connector.
- 05. XLR 5-Pin DMX Connector: For DMX control.
- 06. Wireless Receiver Antenna: For wireless signal reception.
- 07. SC-4 Remote Connector: Port for the SC-4 wired remote.
- 08. Output Nozzle: Where the snow effect is generated.
- 09. Hanging Bracket: For mounting the machine.
- 10. Technical Label: Contains important machine information.
Diagram Description: An image shows the snow machine with numbered callouts pointing to the control panel, power connectors, DMX connector, remote connector, output nozzle, antenna, and hanging bracket.
5. Technical Label Information
Read the information on the technical label before operation. The technical label is attached on one side of the control panel.
Label Details:
- 1. Model Name: S-600 Yeti
- 2. Input Voltage: XXXVac (e.g., 100-120V or 220-240V)
- 3. Frequency: 50/60Hz
- 4. Rated Power: XXXXW (e.g., 1200W)
- 5. QR CODE for User Manual: A QR code linking to the user manual.
- 6. Serial No.: Unique identifier for the unit.
- 7. Breaker: Indicates the circuit breaker rating (e.g., XA 250V).
- Made in Taiwan
6. Snow Fluid
CAUTION!
Always disconnect from the mains before filling the machine. Never add flammable liquids. If fluid gets inside the machine, please contact your local Antari dealer for service.
Only use Antari SL-N, SL-AN, SL-H, SL-C, SL-UV fluid for the S-600 Snow Machine. The machine is tested and calibrated with this liquid to get the best output performance. Warranty will be void if any other type of liquid is used; improper use of liquid may lead to machine failure and malfunction.
7. Setting Up
CAUTION!
Risk of injury caused by falling objects.
- Make sure installation location, fastening, connecting, and rigging hardware can hold at least 10 times the weight of the machine.
- Make sure that the machine is installed securely and cannot fall down. It will cause severe injuries if the machine falls down.
Setup Steps:
- Place the machine on a flat surface and in a suitably large area with at least 50 cm open space around the machine.
- Connect the 5M fluid tube to the S-600 and put the filter into the tank. Please do not bend the fluid tube and fill the fluid tank with Antari snow fluid.
- Connect the machine to a suitably rated power supply. To determine the power requirement for the machine, refer to the label on the back of the machine.
- Turn on the machine, press the [VOLUME]/[DOWN] button on the control panel to start making snow. To stop making snow, press the [STOP] / [■] button.
- To turn off the machine, press the [STOP] / [■] button and put the power switch to the OFF position.
Notice: The motor of the S-600 continues running for about 5 seconds after the [STOP] / [■] button is pressed. Please turn off the main power after the motor stops running.
8. Operation
The S-600 Yeti snow machine can be operated in the following modes. The machine can accept 1 kind of signal at a time. When using different control modes simultaneously, the machine will work according to built-in control priority.
Operation Modes:
- Manual: operation via control panel
- Timer: operation via control panel
- DMX 512
- SC-4 Wired Remote (Optional)
- Wireless DMX (Optional)
- W-2 Wireless Transmitter
Priority: Wireless DMX (Optional) > DMX512 > W-2 Wireless Transmitter > SC-4 Wired Remote (Optional) > Manual
8.1 Control Panel Operation
The machine can be operated in manual or timer modes with the onboard digital control interface.
Diagram Description: A simplified image of the control panel display shows 'Ready' and 'To Snow' status, with buttons labeled TIMER and VOLUME.
| Button | Function |
|---|---|
| [MENU] | Scroll through setting menu |
| [UP]/[TIMER] | Increase setting value/Activate Timer function |
| [DOWN]/[VOLUME] | Decrease setting value/Activate Volume function |
| [STOP] | Deactivate Timer/Volume function, Confirm/Leave Setting Menu |
8.2 Control Menu
| Menu | Item | Description |
|---|---|---|
| DMX | DMX512 Add: XXX | DMX-512 Address: 1-510 (S-600 occupies 3 control channels.) |
| LinkMode | Link Mode: Wired / Wireless | |
| Manual | Wired | W-DMX Linking |
| W-DMX Unlink? | Linking cancelled | |
| Interval XXX min | Set interval time at timer mode from 5 to 240 minutes | |
| Duration XXX min | Set duration time at timer mode from 5 to 240 minutes | |
| Volume Out XXX% | Set output volume at volume mode from 0 to 100% | |
| Blower XXX% | Set blower output from 0 to 100% to adjust snowflake size. The smaller output, the bigger snowflake. | |
| Fan Speed XXX% | Set fan speed from 0 to 100% | |
| Info | W-DMX ok | W-DMX Transmitter assigned, DMX signal received. |
| No DMX | W-DMX transmitter assigned, No DMX signal | |
| TX Lost | W-DMX link lost or linking to transmitter | |
| Unassign | W-DMX Transmitter not assigned | |
| UID 1ED8 06020001 | Product UID Code | |
| Run Time | 0000000H | Accumulated Snowing time: 0 - 9999999 hour |
| Setting | W.Remote Pair | Wireless Transmitter: Pair / Unpair |
| Run Last Set Off | Run the last setting: On / Off | |
| KeySound Set On | Keypad Sound: On / Off | |
| Backlite AlwaysOn | Screen Backlite: On/Off / AlwaysOn | |
| Default Proceed? | Reset to factory settings |
9. Machine Status Message
| Screen | Description |
|---|---|
| S-600 v1.0 | Software Version |
| AC Input | Input Voltage |
| AC-XXX | Machine is ready to make snow. |
| Ready | SC-4 wired remote operating (only shows when SC-4 is connected) |
| To Snow | Running at volume mode |
| Remote Out XXX% | Running at timer mode, Interval time |
| Volume Out XXX% | Running at timer mode, Duration time |
| Interval XXX min | Current DMX 512 channel |
| Duration XXX min | Activate pump at maximum output |
| DMX-512 Add: XXX | Wrong input voltage |
| Priming | |
| 100% | |
| Wrong Voltage! |
10. DMX Connection
10.1 DMX Connector Pin Assignment
The machine provides a 5-pin XLR connector for DMX connection. The diagram below indicates pin assignment information.
Diagram Description: A 5-pin XLR connector is shown with pins labeled 1 through 5. A table lists the pin functions.
| Pin | Function |
|---|---|
| 1 | Ground |
| 2 | Data- |
| 3 | Data+ |
| 4 | N/A |
| 5 | N/A |
10.2 DMX Channel Function
| Channel | Mode | DMX Value | Function |
|---|---|---|---|
| Channel 1 | Snow Output Volume | 0-5 | Snow off |
| 6-255 | Snow Output 0-100% | ||
| Channel 2 | Blower Output | 0-5 | Blower off |
| 6-255 | Blower Output 0-100% | ||
| Channel 3 | Fan Output | 0-5 | Fan Off |
| 6-255 | Fan Output 0-100% |
11. RDM
The S-600 snow machine Yeti is RDM enabled, allowing control system to configure, monitor, and manage. See below table for supported RDM parameters.
| GET Allowed | SET Allowed | Category | RDM Parameter ID's (Slot 21-22) | Value | Required |
|---|---|---|---|---|---|
| ○ | Network Management | DISC_UNIQUE_BRANCH | 0x0001 | O | |
| ○ | DISC_MUTE | 0x0002 | O | ||
| ○ | DISC_UN_MUTE | 0x0003 | O | ||
| ○ | RDM Information | QUEUED_MESSAGE | 0x0020 | O | |
| ○ | ○ | SUPPORTED_PARAMETERS | 0x0050 | O | |
| ○ | ○ | PARAMETER_DESCRIPTION | 0x0051 | O | |
| ○ | DEVICE_INFO | 0x0060 | O | ||
| ○ | PRODUCT_DETAIL_ID_LIST | 0x0070 | O | ||
| ○ | ○ | Product Information | DEVICE_MODEL_DESCRIPTION | 0x0080 | O |
| ○ | ○ | MANUFACTURER_LABEL | 0x0081 | O | |
| ○ | ○ | DEVICE_LABEL | 0x0082 | O | |
| ○ | ○ | SOFTWARE_VERSION_LABEL | 0x00C0 | O | |
| ○ | ○ | DMX512 Setup | DMX_PERSONALITY | 0x00E0 | O |
| ○ | ○ | DMX_PERSONALITY_DESCRIPTION | 0x00E1 | O | |
| ○ | ○ | DMX_START_ADDRESS | 0x00F0 | O | |
| ○ | SLOT_INFO | (0x0120) | O | ||
| ○ | SLOT_DESCRIPTION | (0x0121) | O | ||
| ○ | DEFAULT_SLOT_VALUE | (0x0122) | O | ||
| ○ | ○ | Sensors | SENSOR_DEFINITION | 0x0200 | O |
| ○ | ○ | SENSOR_VALUE | 0x0201 | O | |
| ○ | ○ | Control | DEVICE_HOURS | 0x0400 | O |
| ○ | ○ | IDENTIFY_DEVICE | 0x1000 | O |
12. Wireless Control Operation
The S-600 is equipped with W-2 wireless control function as a standard. The receiver is attached onto the S-600 before shipped from the factory.
12.1 W-2 Wireless Transmitter
- Battery: 27A 12V
- Effective distance: In a free open space, the effective distance is about 50 meters; actual usage depends on obstacle level, and the effective distance varies.
- The W-2 Wireless remote control system is equipped with 4 buttons to activate, deactivate, adjust snow, motor, and fan output level.
| Button | Function |
|---|---|
| [A] | Press Once: activate output Keep pressing for 2 seconds: turn off S-600 |
| [B] | Adjust snow output level |
| [C] | Adjust motor output level |
| [D] | Adjust fan output level |
Diagram Description: Images show the W-2 Wireless Transmitter and the W-2 Wireless Receiver.
12.2 W-2 Wireless Receiver
The S-600 is equipped with W-2 wireless control function as a standard. The transmitter is included in the package. The receiver is attached onto the S-600 before shipped from the factory.
12.3 Registering a Transmitter
- Transmitter can be paired or deleted from the receiver.
- Each receiver can pair up to 5 transmitters.
- Follow below steps to pair or delete a transmitter.
- Press the [MENU] button and select [Setting]. Scroll through the menu until [W.Remote] shows on the display.
UP: Pair
DOWN: Unpair - Step 2A: Press the [UP / ▲] button to select [Pair] to pair a new transmitter. Press the [STOP / ■] button, and then press any button on the W-2 transmitter to finish pairing.
- Step 2B: Press the [DOWN / ▼] button to select [Unpair] to delete an existing transmitter.
13. Wireless DMX Operation (Optional)
13.1 WTR-90 (Optional)
WTR-90 includes a 2-in-1 (W-DMX & W-2) receiver and a W-DMX-PCB.
Diagram Description: Images show the 2-in-1 receiver (W-DMXW2R) and the W-DMX-PCB.
13.2 Installation Steps
- Release and unscrew the existing receiver, and replace it with the 2-in-1 receiver (W-DMXW2R). Connect it to the cable shown in the photo and then screw it to the panel.
- Connect the receiver's cable with the W-DMX-PCB and then install the W-DMX-PCB onto the main PCB, circled in red below.
Notice: Please make sure the W-DMX-PCB pins are firmly installed and attached to the S-600 main PCB.
Diagram Description: Images show the connection of the receiver cable to the W-DMX-PCB and the installation of the W-DMX-PCB onto the main PCB.
14. SC-4 Wired Remote Operation (Optional)
Wired remote control SC-4 enables control of the machine from a remote location. It features three push buttons and 3 rotary knobs for activating/deactivating, priming, and snow, motor, and fan output level adjustment.
| Button/Knob | Function |
|---|---|
| [SNOW VOLUME] Knob | Adjust snow output level 0-100% |
| [BLOWER SPEED] Knob | Adjust motor output level 0-100% to adjust snowflake size. |
| [FAN SPEED] Knob | Adjust fan output level 0-100% |
| [TIMER] Button | Activate Timer Setting. Interval and duration time is set on the control panel. Output level is controlled by rotary knob on SC-4. |
| [POWER] Button | Turn On/Off SC-4 remote |
| [MANUAL] Button | Max snow, motor, and fan output level. |
IMPORTANT NOTE:
- Press the [POWER] button to activate the SC-4 remote.
- With first-time operation, a new tank of fluid or refilled fluid may not pump properly due to airlock in the pipeline. Use the [MANUAL] button to activate the pump, motor, and fan at maximum output to push the air out of the pipeline.
Diagram Description: Images show the SC-4 Connector port and the Antari SC-4 Wired Remote control unit.
15. S-600-BH / 5-liter bottle holder (Optional)
The optional S-600-BH / 5-liter bottle holder is available to meet the needs of different occasions. Follow below steps to install the bottle holder.
- Release the T-shaped handle on the S-600.
- Install the S-600-BH to the machine.
- Screw the T-shaped handle back to the S-600 tightly to complete the installation.
Diagram Description: Images show the bottle holder and the installation process on the snow machine.
16. Service and Maintenance
DANGER!
Disconnect from mains before starting maintenance operation!
- Do not allow the machine to become contaminated.
- Remove dust from air vents with an air compressor, vacuum, or a soft brush.
- Only use a damp cloth to clean the casing.
- It is recommended to run the machine on a monthly basis to achieve the best performance and output condition.
- Excessive dust, liquid, and dirt buildup will degrade performance and cause overheating.
- Before storing away after operation, pump pure water through the system for at least 1 to 2 minutes. This will help clean out the remaining snow fluid and prevent pump malfunction on next usage.
17. Technical Specifications
S-600
| Parameter | Specification |
|---|---|
| Input voltage | US model: AC 100-120V, 50/60Hz 10A EU model: AC 220-240V, 50/60Hz 5A |
| Rated power | 1200W |
| Fluid consumption | 400 ml/min |
| Compatible fluid | Antari SL-N Snow Foam Fluid Antari SL-AN Premium Snow Foam Fluid Antari SL-H Super Dry Snow Foam Fluid Antari SL-C Anti-Freezing Snow Foam Fluid Antari SL-UV UV Snow Foam Fluid |
| Ambient temp/ range | 5°C ~ 40°C (41°F – 104°F) |
| Control | Manual, Timer, DMX 512, Wireless Wireless DMX (Optional) |
| DMX channels | 3 channels |
| Connection | Neutrik Powercon (Power) XLR 5-pin (DMX) |
| Included accessories | W-2 Wireless Radio Transmitter 5-Meter Fluid Tube with Filter Hanging Bracket |
| Optional accessories | WTR-90 Wireless DMX SC-4 Cable Remote S-600-BH Bottle Holder (For 5-Liter Bottle. Bottle is not included) |
| Dimension | L 461.2 W 596 H 629.6 mm (L 18.16 W 23.47 H 24.79 inch) |
| Weight | 24 kg (52.9 lbs) |
18. Machine Dimension
Diagram Description: An illustration shows the snow machine with dimensions indicated: Length 461.2 mm, Width 596 mm, Height 629.6 mm.
19. Exploded diagram
19.1 AC-120V
Diagram Description: An exploded view of the S-600 snow machine for the AC-120V model, showing all components with numbered callouts.
| # | Part Name | Description |
|---|---|---|
| 1 | S-600-M | Air blower |
| 2 | C040039B0 | Rocker switch / Power |
| 3 | C04312621 | Power socket (Inlet) |
| 4 | S-600-PCBD5 | P.C board DMX 5Pin |
| 5 | W-2A | Wireless transmitter |
| 6 | C045E2900 | Control inlet socket |
| 7 | C00013610 | Fluid tube connector |
| 8 | S-600-P | Pump (Group) |
| 9 | S60000100 | Steel |
| 10 | C02000700 | Acrylic |
| 11 | S-600-PCBC | Control P.C board |
| 12 | S-600-PCB | Main P.C board |
| 13 | C01007010 | Socket head cap screw |
| 14 | C02025000 | Handle |
| 15 | S-600-PC | Power cord & Plug |
| 16 | W-2RA | Wireless Receiver |
| 17 | FT-P-6-4A-5M | Fluid tube with filter / 5M |
| 18 | SC-4 | Wired remote controller (Optional) |
| 19 | S-600-BH | Bottle holder (Optional) |
19.2 AC-230V
Diagram Description: An exploded view of the S-600 snow machine for the AC-230V model, showing all components with numbered callouts.
| # | Part Name | Description |
|---|---|---|
| 1 | S-600E-M | Air blower |
| 2 | C040039A0 | Rocker switch / Power |
| 3 | C04312621 | Power socket (Inlet) |
| 4 | S-600-PCBD5 | P.C board DMX 5Pin |
| 5 | W-2E | Wireless transmitter |
| 6 | C045E2900 | Control inlet socket |
| 7 | C00013610 | Fluid tube connector |
| 8 | S-600-P | Pump (Group) |
| 9 | S60000100 | Steel |
| 10 | C02000700 | Acrylic |
| 11 | S-600-PCBC | Control P.C board |
| 12 | S-600-PCB | Main P.C board |
| 13 | C01007010 | Socket head cap screw |
| 14 | C02025000 | Handle |
| 15 | S-600-PC | Power cord & Plug |
| 16 | W-2RE | Wireless Receiver |
| 17 | FT-P-6-4A-5M | Fluid tube with filter / 5M |
| 18 | SC-4 | Wired remote controller (Optional) |
| 19 | S-600-BH | Bottle holder (Optional) |