1. Introduction

Please read this user manual carefully before operating the machine. Keep this manual in a place where you can refer to it at any time. If you encountered any problems, please contact your local Antari dealer for advice and assistance.

2. Safety Information

⚠️ CAUTION!

Please read the following safety information carefully before operating the machine. This information includes important safeguards about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the machine.

⚡ DANGER! Electrical shock

Always connect the machine to correct voltage. It will lead to electrical shock or burns and may cause serious consequences if connecting to incorrect or improper voltage.

⚡ WARNING! Risk of electrocution

Always connect the machine to a protected circuit and ensure it is properly grounded to avoid risk of electrocution.

Damage caused by the disregard of this user manual is not subject to warranty. Antari and its dealer will not accept liability for any resulting defects or problems.

2.1 Installation

2.2 Operation

2.3 Grounding Instruction

This appliance must be grounded in the event of malfunction or breakdown. Grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER – Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal. Check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician.

This appliance is for use on a nominal 120V circuit and has a grounding plug that looks like the plug illustrated in sketch A. A temporary adaptor, which looks like the adaptor illustrated in sketches B and C, may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet can be installed by a qualified electrician. The green colored rigid ear, lug, and the like, extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by the metal screw.

Diagram Description: Sketch A shows a standard three-prong plug and a grounded outlet. Sketch B shows a two-prong outlet with a temporary adapter connected, illustrating how the grounding means of the adapter connects to the outlet box cover. Sketch C shows the grounding means of the adapter.

3. Package Items

Immediately upon receiving the machine, carefully unpack the carton and check the contents to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retain the packing material for inspection.

3.1 Standard Package

3.2 Optional Accessories

Item Code Description
WTR-90 W-2 & W-DMX Receiver & W-DMX-PCB
SC-4 Cable Remote
S-600-BH 5-Liter Bottle Holder

4. Product Overview

The S-600 Yeti Snow Machine features the following components:

Diagram Description: An image shows the snow machine with numbered callouts pointing to the control panel, power connectors, DMX connector, remote connector, output nozzle, antenna, and hanging bracket.

5. Technical Label Information

Read the information on the technical label before operation. The technical label is attached on one side of the control panel.

Label Details:

6. Snow Fluid

CAUTION!

Always disconnect from the mains before filling the machine. Never add flammable liquids. If fluid gets inside the machine, please contact your local Antari dealer for service.

Only use Antari SL-N, SL-AN, SL-H, SL-C, SL-UV fluid for the S-600 Snow Machine. The machine is tested and calibrated with this liquid to get the best output performance. Warranty will be void if any other type of liquid is used; improper use of liquid may lead to machine failure and malfunction.

7. Setting Up

CAUTION!

Risk of injury caused by falling objects.

Setup Steps:

  1. Place the machine on a flat surface and in a suitably large area with at least 50 cm open space around the machine.
  2. Connect the 5M fluid tube to the S-600 and put the filter into the tank. Please do not bend the fluid tube and fill the fluid tank with Antari snow fluid.
  3. Connect the machine to a suitably rated power supply. To determine the power requirement for the machine, refer to the label on the back of the machine.
  4. Turn on the machine, press the [VOLUME]/[DOWN] button on the control panel to start making snow. To stop making snow, press the [STOP] / [■] button.
  5. To turn off the machine, press the [STOP] / [■] button and put the power switch to the OFF position.

Notice: The motor of the S-600 continues running for about 5 seconds after the [STOP] / [■] button is pressed. Please turn off the main power after the motor stops running.

8. Operation

The S-600 Yeti snow machine can be operated in the following modes. The machine can accept 1 kind of signal at a time. When using different control modes simultaneously, the machine will work according to built-in control priority.

Operation Modes:

Priority: Wireless DMX (Optional) > DMX512 > W-2 Wireless Transmitter > SC-4 Wired Remote (Optional) > Manual

8.1 Control Panel Operation

The machine can be operated in manual or timer modes with the onboard digital control interface.

Diagram Description: A simplified image of the control panel display shows 'Ready' and 'To Snow' status, with buttons labeled TIMER and VOLUME.

Button Function
[MENU] Scroll through setting menu
[UP]/[TIMER] Increase setting value/Activate Timer function
[DOWN]/[VOLUME] Decrease setting value/Activate Volume function
[STOP] Deactivate Timer/Volume function, Confirm/Leave Setting Menu

8.2 Control Menu

Menu Item Description
DMX DMX512 Add: XXX DMX-512 Address: 1-510 (S-600 occupies 3 control channels.)
LinkMode Link Mode: Wired / Wireless
Manual Wired W-DMX Linking
W-DMX Unlink? Linking cancelled
Interval XXX min Set interval time at timer mode from 5 to 240 minutes
Duration XXX min Set duration time at timer mode from 5 to 240 minutes
Volume Out XXX% Set output volume at volume mode from 0 to 100%
Blower XXX% Set blower output from 0 to 100% to adjust snowflake size. The smaller output, the bigger snowflake.
Fan Speed XXX% Set fan speed from 0 to 100%
Info W-DMX ok W-DMX Transmitter assigned, DMX signal received.
No DMX W-DMX transmitter assigned, No DMX signal
TX Lost W-DMX link lost or linking to transmitter
Unassign W-DMX Transmitter not assigned
UID 1ED8 06020001 Product UID Code
Run Time 0000000H Accumulated Snowing time: 0 - 9999999 hour
Setting W.Remote Pair Wireless Transmitter: Pair / Unpair
Run Last Set Off Run the last setting: On / Off
KeySound Set On Keypad Sound: On / Off
Backlite AlwaysOn Screen Backlite: On/Off / AlwaysOn
Default Proceed? Reset to factory settings

9. Machine Status Message

Screen Description
S-600 v1.0 Software Version
AC Input Input Voltage
AC-XXX Machine is ready to make snow.
Ready SC-4 wired remote operating (only shows when SC-4 is connected)
To Snow Running at volume mode
Remote Out XXX% Running at timer mode, Interval time
Volume Out XXX% Running at timer mode, Duration time
Interval XXX min Current DMX 512 channel
Duration XXX min Activate pump at maximum output
DMX-512 Add: XXX Wrong input voltage
Priming
100%
Wrong Voltage!

10. DMX Connection

10.1 DMX Connector Pin Assignment

The machine provides a 5-pin XLR connector for DMX connection. The diagram below indicates pin assignment information.

Diagram Description: A 5-pin XLR connector is shown with pins labeled 1 through 5. A table lists the pin functions.

Pin Function
1 Ground
2 Data-
3 Data+
4 N/A
5 N/A

10.2 DMX Channel Function

Channel Mode DMX Value Function
Channel 1 Snow Output Volume 0-5 Snow off
6-255 Snow Output 0-100%
Channel 2 Blower Output 0-5 Blower off
6-255 Blower Output 0-100%
Channel 3 Fan Output 0-5 Fan Off
6-255 Fan Output 0-100%

11. RDM

The S-600 snow machine Yeti is RDM enabled, allowing control system to configure, monitor, and manage. See below table for supported RDM parameters.

GET Allowed SET Allowed Category RDM Parameter ID's (Slot 21-22) Value Required
Network Management DISC_UNIQUE_BRANCH 0x0001 O
DISC_MUTE 0x0002 O
DISC_UN_MUTE 0x0003 O
RDM Information QUEUED_MESSAGE 0x0020 O
SUPPORTED_PARAMETERS 0x0050 O
PARAMETER_DESCRIPTION 0x0051 O
DEVICE_INFO 0x0060 O
PRODUCT_DETAIL_ID_LIST 0x0070 O
Product Information DEVICE_MODEL_DESCRIPTION 0x0080 O
MANUFACTURER_LABEL 0x0081 O
DEVICE_LABEL 0x0082 O
SOFTWARE_VERSION_LABEL 0x00C0 O
DMX512 Setup DMX_PERSONALITY 0x00E0 O
DMX_PERSONALITY_DESCRIPTION 0x00E1 O
DMX_START_ADDRESS 0x00F0 O
SLOT_INFO (0x0120) O
SLOT_DESCRIPTION (0x0121) O
DEFAULT_SLOT_VALUE (0x0122) O
Sensors SENSOR_DEFINITION 0x0200 O
SENSOR_VALUE 0x0201 O
Control DEVICE_HOURS 0x0400 O
IDENTIFY_DEVICE 0x1000 O

12. Wireless Control Operation

The S-600 is equipped with W-2 wireless control function as a standard. The receiver is attached onto the S-600 before shipped from the factory.

12.1 W-2 Wireless Transmitter

Button Function
[A] Press Once: activate output
Keep pressing for 2 seconds: turn off S-600
[B] Adjust snow output level
[C] Adjust motor output level
[D] Adjust fan output level

Diagram Description: Images show the W-2 Wireless Transmitter and the W-2 Wireless Receiver.

12.2 W-2 Wireless Receiver

The S-600 is equipped with W-2 wireless control function as a standard. The transmitter is included in the package. The receiver is attached onto the S-600 before shipped from the factory.

12.3 Registering a Transmitter

  1. Press the [MENU] button and select [Setting]. Scroll through the menu until [W.Remote] shows on the display.
    UP: Pair
    DOWN: Unpair
  2. Step 2A: Press the [UP / ▲] button to select [Pair] to pair a new transmitter. Press the [STOP / ■] button, and then press any button on the W-2 transmitter to finish pairing.
  3. Step 2B: Press the [DOWN / ▼] button to select [Unpair] to delete an existing transmitter.

13. Wireless DMX Operation (Optional)

13.1 WTR-90 (Optional)

WTR-90 includes a 2-in-1 (W-DMX & W-2) receiver and a W-DMX-PCB.

Diagram Description: Images show the 2-in-1 receiver (W-DMXW2R) and the W-DMX-PCB.

13.2 Installation Steps

  1. Release and unscrew the existing receiver, and replace it with the 2-in-1 receiver (W-DMXW2R). Connect it to the cable shown in the photo and then screw it to the panel.
  2. Connect the receiver's cable with the W-DMX-PCB and then install the W-DMX-PCB onto the main PCB, circled in red below.

Notice: Please make sure the W-DMX-PCB pins are firmly installed and attached to the S-600 main PCB.

Diagram Description: Images show the connection of the receiver cable to the W-DMX-PCB and the installation of the W-DMX-PCB onto the main PCB.

14. SC-4 Wired Remote Operation (Optional)

Wired remote control SC-4 enables control of the machine from a remote location. It features three push buttons and 3 rotary knobs for activating/deactivating, priming, and snow, motor, and fan output level adjustment.

Button/Knob Function
[SNOW VOLUME] Knob Adjust snow output level 0-100%
[BLOWER SPEED] Knob Adjust motor output level 0-100% to adjust snowflake size.
[FAN SPEED] Knob Adjust fan output level 0-100%
[TIMER] Button Activate Timer Setting. Interval and duration time is set on the control panel. Output level is controlled by rotary knob on SC-4.
[POWER] Button Turn On/Off SC-4 remote
[MANUAL] Button Max snow, motor, and fan output level.

IMPORTANT NOTE:

  1. Press the [POWER] button to activate the SC-4 remote.
  2. With first-time operation, a new tank of fluid or refilled fluid may not pump properly due to airlock in the pipeline. Use the [MANUAL] button to activate the pump, motor, and fan at maximum output to push the air out of the pipeline.

Diagram Description: Images show the SC-4 Connector port and the Antari SC-4 Wired Remote control unit.

15. S-600-BH / 5-liter bottle holder (Optional)

The optional S-600-BH / 5-liter bottle holder is available to meet the needs of different occasions. Follow below steps to install the bottle holder.

  1. Release the T-shaped handle on the S-600.
  2. Install the S-600-BH to the machine.
  3. Screw the T-shaped handle back to the S-600 tightly to complete the installation.

Diagram Description: Images show the bottle holder and the installation process on the snow machine.

16. Service and Maintenance

DANGER!

Disconnect from mains before starting maintenance operation!

17. Technical Specifications

S-600

Parameter Specification
Input voltage US model: AC 100-120V, 50/60Hz 10A
EU model: AC 220-240V, 50/60Hz 5A
Rated power 1200W
Fluid consumption 400 ml/min
Compatible fluid Antari SL-N Snow Foam Fluid
Antari SL-AN Premium Snow Foam Fluid
Antari SL-H Super Dry Snow Foam Fluid
Antari SL-C Anti-Freezing Snow Foam Fluid
Antari SL-UV UV Snow Foam Fluid
Ambient temp/ range 5°C ~ 40°C (41°F – 104°F)
Control Manual, Timer, DMX 512, Wireless
Wireless DMX (Optional)
DMX channels 3 channels
Connection Neutrik Powercon (Power)
XLR 5-pin (DMX)
Included accessories W-2 Wireless Radio Transmitter
5-Meter Fluid Tube with Filter
Hanging Bracket
Optional accessories WTR-90 Wireless DMX
SC-4 Cable Remote
S-600-BH Bottle Holder (For 5-Liter Bottle. Bottle is not included)
Dimension L 461.2 W 596 H 629.6 mm (L 18.16 W 23.47 H 24.79 inch)
Weight 24 kg (52.9 lbs)

18. Machine Dimension

Diagram Description: An illustration shows the snow machine with dimensions indicated: Length 461.2 mm, Width 596 mm, Height 629.6 mm.

19. Exploded diagram

19.1 AC-120V

Diagram Description: An exploded view of the S-600 snow machine for the AC-120V model, showing all components with numbered callouts.

# Part Name Description
1 S-600-M Air blower
2 C040039B0 Rocker switch / Power
3 C04312621 Power socket (Inlet)
4 S-600-PCBD5 P.C board DMX 5Pin
5 W-2A Wireless transmitter
6 C045E2900 Control inlet socket
7 C00013610 Fluid tube connector
8 S-600-P Pump (Group)
9 S60000100 Steel
10 C02000700 Acrylic
11 S-600-PCBC Control P.C board
12 S-600-PCB Main P.C board
13 C01007010 Socket head cap screw
14 C02025000 Handle
15 S-600-PC Power cord & Plug
16 W-2RA Wireless Receiver
17 FT-P-6-4A-5M Fluid tube with filter / 5M
18 SC-4 Wired remote controller (Optional)
19 S-600-BH Bottle holder (Optional)

19.2 AC-230V

Diagram Description: An exploded view of the S-600 snow machine for the AC-230V model, showing all components with numbered callouts.

# Part Name Description
1 S-600E-M Air blower
2 C040039A0 Rocker switch / Power
3 C04312621 Power socket (Inlet)
4 S-600-PCBD5 P.C board DMX 5Pin
5 W-2E Wireless transmitter
6 C045E2900 Control inlet socket
7 C00013610 Fluid tube connector
8 S-600-P Pump (Group)
9 S60000100 Steel
10 C02000700 Acrylic
11 S-600-PCBC Control P.C board
12 S-600-PCB Main P.C board
13 C01007010 Socket head cap screw
14 C02025000 Handle
15 S-600-PC Power cord & Plug
16 W-2RE Wireless Receiver
17 FT-P-6-4A-5M Fluid tube with filter / 5M
18 SC-4 Wired remote controller (Optional)
19 S-600-BH Bottle holder (Optional)
Models: S-600, Yeti Snow Machine, S-600 Yeti Snow Machine

File Info : application/pdf, 23 Pages, 2.27MB

antari S-600 manual

References

Microsoft Word 2016

Related Documents

Preview Antari Z-350 Fazer Fog Machine: Specifications, Features, and Overview
Explore the Antari Z-350 Fazer, a professional fog machine offering superior CP value, lightweight design, and advanced features like Air Pump, smart saving mode, and DMX512 control. Ideal for creating vibrant atmospheric effects.
Preview Antari S-100X / S-200X Snow Machine User Manual and Technical Guide
Comprehensive user manual and technical specifications for Antari S-100X and S-200X snow machines, covering setup, operation, DMX control, maintenance, and safety.
Preview Antari SW-250/SW-250X Snow Machine User Manual - High Output Wireless Control
Comprehensive user manual for the Antari SW-250 and SW-250X high output wireless snow machines. Covers setup, operation, remote control, DMX, maintenance, and technical specifications.
Preview Antari DNG-250 Low Fog Generator User Manual | Operation & Maintenance Guide
Comprehensive user manual for the Antari DNG-250 Low Fog Generator. Learn about setup, operation, safety, maintenance, technical specifications, and troubleshooting. Get detailed instructions for this professional fog machine.
Preview Antari IP-1000 Waterproof Fog Machine User Manual
Comprehensive user manual for the Antari IP-1000 Waterproof Fog Machine, detailing setup, operation, safety guidelines, technical specifications, cleaning, maintenance, and warranty information.
Preview Antari J-100 SonicJet Fog Machine User Manual
Comprehensive user manual for the Antari J-100 SonicJet Fog Machine, detailing setup, operation, safety guidelines, technical specifications, maintenance, and troubleshooting.
Preview Antari FT-200 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-200 Fire Training Fog Machine. This guide covers essential safety information, unpacking and inspection, product overview, setup instructions, detailed operation modes (timer, volume, DMX, wireless), control panel functions, menu settings, fluid recommendations, maintenance procedures, breaker reset, and technical specifications.
Preview Antari FT-100 Fire Training Fog Machine User Manual
Comprehensive user manual for the Antari FT-100 Fire Training Fog Machine, detailing setup, operation, safety precautions, maintenance, and technical specifications. Essential for fire training simulations.