Honeywell Unitary Controller

Mounting Instructions / Instructions de Montage / Instrucciones de Montaje

Important Information

Keep these instructions together with the device or with the equipment documentation.

French: Cette instruction est à conserver avec le contrôleur ou avec la documentation de l'installation!

Spanish: Conserve estas instrucciones con el equipo o con la documentación del producto.

1. Contents of Shipment

French: CONTENU DE L'EXPÉDITION

Spanish: CONTENIDO DEL ENVÍO

2. Storage and Operation

French: ENTREPOSAGE ET EXPLOITATION

Spanish: CONDICIONES DE ALMACENAMIENTO Y OPERACIÓN

Storage Temperature: -40 °F to 150 °F (-40 °C to 66 °C)

Operation Temperature: -40 °F to 122 °F (-40 °C to 50 °C)

Humidity: 95% RH/HR/de HR (non-condensing)

Note: Protect from water ingress.

3. Dimensions

3.1 Large Housing Model

Width: 4.79 inches (121.6 mm)

Height: 4.55 inches (115.6 mm)

Depth: 5.16 inches (131.1 mm)

Mounting Slot Height: 1.77 inches (45.1 mm)

Overall Depth with Connector: 2.09 inches (53 mm)

3.2 Small Housing Model

Width: 4.33 inches (110 mm)

Height: 4.55 inches (115.6 mm)

Depth: 5.16 inches (131.1 mm)

Mounting Slot Height: 1.77 inches (45.1 mm)

Overall Depth with Connector: 2.09 inches (53 mm)

Note: All dimensions are in inches (mm).

4. Permissible Orientations

The controller can be mounted in various orientations. Ensure proper airflow and access for maintenance.

Permissible temperature ranges for different orientations:

5. DIN Rail End Stop

A DIN rail end stop is required for proper mounting on a standard DIN rail.

6. DIN Rail Mounting

  1. Mount the DIN rail on the wall/panel using screws.
  2. Extend all mounting red clips to the unlock position.
  3. Hold the controller and mount it onto the DIN rail.
  4. Push all red tabs into the Lock position to secure in place.

7. Wall Mounting

  1. Extend all red clips to the screw mounting position.
  2. Hold the controller against the wall and mark drilling locations through the screw red clip slots.
  3. Remove the controller from the wall and drill four holes at the marked locations.
  4. Insert anchors into the four mounting screw holes.
  5. Place the controller on the wall/surface so that the holes are aligned. Insert screws into the topside holes first and fasten with a screwdriver.
  6. Insert screws into the bottom holes and fasten with a screwdriver.

Note: It is recommended to use 6-18 1-inch pan head phillips tapping screws.

Warnings and Cautions

Electrical Shock Hazard

Can cause severe injury, death or property damage. Disconnect the power supply before beginning installation to prevent electrical shock and equipment damage. More than one power supply may have to be disconnected.

CAUTION/MISE EN GARDE/PRECAUCIÓN

To reduce the risk of fire or electric shock, do not interconnect the outputs of different Class 2 circuits.

RISK OF ELECTRICAL SHOCK OR EQUIPMENT DAMAGES!

It is not permitted to combine low voltage and line voltage in the relay block.

WEEE/DEEE/RAEE

Dispose of the product and packaging at an appropriate recycling center at the end of its life. Do not dispose of with domestic refuse or burn the device.

Regulatory Information

CAN RSS-GEN/CNR-GEN CANADIAN CONFORMANCE AND FCC STATEMENTS

This Class B digital apparatus complies with Canadian ICES-003. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

Specifications of the Controller

Power Supply/Alimentation/Alimentación eléctrica

24-30 VDC / 20-30 VAC

Nominal Power Consumption/Consommation d'énergie nominale/Consumo de potencia nominal

IP: 4 VA, MS/TP: 4 VA, T1L: 4 VA

Full Load Power Consumption/Consommation d'énergie à pleine charge/Consumo de potencia a carga completa

IP: 30 VA, MS/TP: 30 VA, T1L: 30 VA

Degree of Protection/Degré de protection/Grado de protección

IP20, NEMA -1

Standards and Approvals/Normes et Approbations/Aprobaciones y Estándares

Purpose of Control: Operating control and multifunctional non-safety control intended for HVAC in-home (residential, commercial, and light-industrial) environments.

Certification

CE mark, BACnet™ BTL®-Listed; UL 916, UL/ULC 60730-1, FCC/IC Product Class B

Construction of Control

Independently mounted electronic control unit with fixed wiring. Panel-mounted on a DIN rail.

Shock Protection/Protection contre les chocs/Protección contra descargas

Class II/Classe II/Clase II

Pollution Degree/Degré de pollution/Grado de suciedad

2

Rated Impulse Voltage/Tension d'impulsion nominale/Tensión nominal a los impulsos

Category I/Catégorie I/Categoría I

Type of Action/Type d'action/Tipo de acción

Type 1.C/Tipo 1.C

Software Class/Classe de logiciel/Clase de software

Class A/Classe A/Clase A

Note: Keep AC mains supply/loads cables separate from signal wiring.

China RoHS Table

This table lists hazardous substances in components of the Honeywell Unitary Controller.

Component Name/Nom du composant Lead (Pb)/Plomb (Pb)/Plomo (Pb) Mercury (Hg)/Mercure (Hg)/Mercurio (Hg) Cadmium (Cd)/Cadmium (Cd)/Cadmio (Cd) Hexavalent Chromium (Cr(VI))/ chrome hexavalent (Cr(VI))/cromo hexavalente (Cr(VI)) Polybrominated Biphenyls (PBB)/ Polybromobiphényle (PBB)/Polibromobifenilos (PBB) Polybrominated Diphenyl Ethers (PBDE)/ éthers diphényliques polybromés (PBDE)/éteres difenilicos polibromados (PBDE)
PRINTED CIRCUIT BOARD ASSEMBLIES/ENSEMBLES DE CARTES DE CIRCUITS IMPRIMÉS/PLACAS DE CIRCUITO IMPRESO X 0 0 0 0 0
ELECTRICAL COMPONENTS/COMPOSANTS ÉLECTRIQUES/COMPONENTES ELÉCTRICOS X 0 0 0 0 0
METAL COMPONENTS/COMPOSANTS MÉTALLIQUES/COMPONENTES METÁLICOS X 0 0 0 0 0
TERMINAL ASSEMBLY/ASSEMBLAGE DES BORNES/ENSAMBLE DE TERMINALES X 0 0 0 0 0
WIRING AND CABLE/CÂBLAGE ET CÂBLE/CABLEADO Y CABLE 0 0 0 0 0 0
RELAY CONTACTS/CONTACTS DU RELAIS/CONTACTOS DE RELÉ 0 0 0 0 0 0
PLASTIC COMPONENTS/COMPOSANTS EN PLASTIQUE/COMPONENTES PLÁSTICOS 0 0 0 0 0 0
Models: 31-00572 Unitary Controller, Unitary Controller, Controller

File Info : application/pdf, 6 Pages, 1.12MB

PDF preview unavailable. Download the PDF instead.

hbt-bms-unitarycontroller24V-mountinginstructions

References

Adobe PDF Library 17.0

Related Documents

Preview Honeywell Optimizer Suite: Step Up to IP Control with Unitary Controllers
Learn how Honeywell's Optimizer Suite and Unitary Controllers enable seamless IP control for building management systems, leveraging T1L technology for efficient data transfer and reduced infrastructure upgrades.
Preview Honeywell Optimizer Unitary Controller Datasheet
Datasheet for Honeywell 230 VAC Optimizer Unitary Controllers, detailing features, specifications, part numbers, dimensions, and communication protocols for advanced building automation systems.
Preview Honeywell Advanced Controller Mounting Instructions
Detailed mounting instructions for the Honeywell Advanced Controller, covering contents of shipment, storage and operation, dimensions, mounting on walls/panels/DIN rails, terminal blocks, and wiring adapters.
Preview Honeywell TR80 Wall Module Mounting Instructions
Comprehensive mounting and installation guide for the Honeywell TR80 Wall Module, detailing wiring, dimensions, and safety precautions in multiple languages.
Preview Honeywell Alerton EU Declaration of Conformity for BACTALK Controllers
Official EU Declaration of Conformity from Honeywell for Alerton BACTALK Unitary Controllers, including model numbers VAV-DD, VAV-DD7, VAV-SD, and VAV-SD2A, compliant with EMC and RoHS directives.
Preview CV30 & Thor CV31 Vehicle Mounting Kit Instructions
Comprehensive instructions for installing the Honeywell CV30 and Thor CV31 vehicle mounting kit, detailing hardware requirements and step-by-step assembly procedures.
Preview Honeywell CIPer Model 30 Controller and Expansion IO Product Data Sheet
Comprehensive product data sheet detailing the Honeywell CIPer Model 30 IP-based EDGE controllers and Expansion IO modules, covering features, specifications, ordering information, system overview, and safety standards.
Preview Honeywell DTI/DTU Differential Pressure Transmitter Installation Guide
Installation instructions for Honeywell DTI (2-Wire) and DTU (3-Wire) Differential Pressure Transmitters. Covers dimensions, electrical connections, pressure specifications, and safety guidelines.