Immergas Zone Remote Panel

Immergas Zone Remote Panel

Code: 3.030863

Congratulations for having chosen a top-quality Immergas product, able to assure well-being and safety for a long period of time. As an Immergas customer you can also count on a qualified after-sales service, prepared and updated to guarantee constant efficiency of your "Remote Control". We would like to provide you with some important indications, your observance of which will ensure your satisfaction with the Immergas product:

  • Read the following pages carefully: you will find useful suggestions regarding the correct use of the device.
  • For assistance and scheduled maintenance, contact "Immergas Authorised After-Sales centres": they have original spare parts and are specifically trained.

How to Use the Instruction Book

The instruction book has been divided into 3 main parts:

In the first, for the installer, the assembly and connection phases of the Zone Remote Panel with the boiler are described;

In the second, all operating program customisation phases are described;

In the third and last part, all operations for displaying and keeping system operation under control are described.

Foreword

The "Zone Remote Panel" is a device designed to guarantee ideal temperature conditions at any time of the day and night for each individual day of the week. Its installation takes a few minutes: it is connected to an appliance via 4 cables, through which, it receives and sends the adjustment and control commands and receives the power supply. On completion of installation it is ready to function thanks to the pre-set program inside. The customer can modify the basic program according to requirements. Programming the Zone Remote Panel is extremely easy and a wide display allows constant control of all values set.

General Warnings

This manual was intended for: the Installer and the User.

  • Carefully read the warnings contained in this document as they are required to indicate the use of the Zone Remote Panel envisioned by the design hypothesis, the technical features, the installation, assembly, programming, adjustment and use instructions.
  • The system must be compliant with applicable IEC Standards.
  • The instruction manual must be considered a part of the Zone Remote Panel and must be "kept for future reference".
  • After having removed the packaging, check the integrity of the Zone Remote Panel. If in doubt, do not use it and contact the Dealer or Manufacturer.
  • The Zone Remote Panel is destined only for the use for which it has been expressly designed. Any other use must be considered improper and therefore dangerous.
  • Immergas products are manufactured in compliance with the Safety Standards in force. It is, therefore, recommended to use all devices and attention in such a way that injury/damage is not caused to persons or objects.
  • Do not remove parts of the Zone Remote Panel when it is functioning.
  • Do not use the Zone Remote Panel if exposed to heat sources or under the scorching sun.
  • The manufacturer will not be held responsible in the following cases: a) Incorrect installation. b) Unauthorised changes or tampering. c) Total or partial failure to comply with instructions. d) Exceptional events etc.

Cleaning the Case

To clean the case of the Zone Remote Panel use damp cloths. Never use abrasive or powder detergents.

WARNING: Immergas reserves the right to make improvements and changes to details and accessories, excepting the essential features of the model described and illustrated herein.

1. Installation

1.1 Zone Remote Panel Main Dimensions

Figure 1 shows the main dimensions of the Zone Remote Panel: Width 128 mm, Height 98 mm, Depth 36 mm.

1.2 Zone Remote Panel Installation Operations

  1. Separate the fixing template from the body of the Zone Remote Panel using a screwdriver as a lever in the relative recess (Fig. 2). Install the Zone Remote Panel away from heat sources and in a suitable position to detect the room temperature correctly.
  2. Install the Zone Remote Panel using the openings on its rear part directly onto the wall or on a recess box using the relative supplied screws.
  3. Connect the Zone Remote Panel to the electronic management clamps, as indicated in the wiring diagram (Fig. 3). The connection is made using wires with a minimum section of 0.50 mm² and maximum section of 1.5 mm² and with a maximum length of 50 metres.
  4. Fix the body of the Zone Remote Panel to the mount template, engaging it with pressure.
  5. After the device has been powered, wait about 30 seconds before regulation so that communication between Zone Remote Panel and the device has established.

2. Use of the Zone Remote Panel

Figure 4 shows the Zone Remote Panel's control interface:

  • 1 - Main parameter switch [button-confirm]
  • 2 - Left context button [button-left]
  • 3 - Right context button [button-right]
  • 4 - Display

3. Operating Mode Selection

Press the "Mode" button to select the following functions: Stand-by, Summer, Summer with Cooling, Winter (Fig. 5). If multiple Zone Remote Panels are present, the operating mode is continuously updated between the various devices.

  • Stand-by / Antifreeze mode [❄️]: In this mode, the appliance can only function in the event of antifreeze request, where this option is available.
  • Summer mode [?]: In this mode the appliance is enabled for producing domestic hot water excluding heating or cooling the room.
  • Summer with Cooling mode [❄️/?]: In Summer with Cooling mode, the appliance is enabled for the production of domestic hot water, for the production of room cooling and for room dehumidification. In "Cooling" mode, the Zone Remote Panel can operate in automatic or temporary manual mode.
  • Winter mode [?/?]: In Winter mode the appliance is enabled for producing domestic hot water and for central heating the room. In Winter mode, the Zone Remote Panel can operate in automatic or temporary manual mode.

Depending on the system mode, the main screen displays various information regarding the system, amongst which:

  • Room humidity value
  • External temperature value (external probe enabled) [?️]
  • Production of Domestic Hot Water in progress [?]
  • Request for room central heating or cooling in progress [?/❄️]
  • Dehumidify and cool room in progress [❄️]
  • Dehumidify room in progress
  • Comfort Temperature operation [☀️]
  • Economy Temperature operation [?]
  • Operation in manual mode
  • External probe enabled [?️]
  • Anomaly present [⚠️]

4. Main Page Setting

The area to which the information refers is shown at the centre of the display. It is possible to display the information on the Zone and on the domestic hot water part. Simply press the main switch [button-confirm] to cyclically go from Zone to DHW (Domestic hot water). The lower part of the display shows the parameter that can be changed (it varies according to the appliance configuration), it is possible to change the value by turning the main switch and pressing it to confirm the parameter change. The values that can be found according to the configuration, are:

  • Set room: Defines the room zone temperature.
  • Set flow: Defines the system's flow temperature to the zone.
  • Flow offset: Changes the operation curve of the external probe.
  • DHW (Domestic hot water) set: This defines the DHW temperature.

5. Summer Mode Functions

With the Zone Remote Panel in Summer mode [?], only the production of DHW is enabled. The DHW setpoint can be set from the dedicated page. If you want to regulate the request for domestic hot water in distinct time bands (Comfort and Economy), it can be set in the Sanitary Setpoint Menu, if the device to which the Zone Remote Panel is connected includes this logic. The time slots used are the same as those used for setting the area's heating / cooling request.

6. Winter Mode Functions

With the Zone Remote Panel in Winter mode [?/?], the production of DHW and room central heating are enabled. Two main functioning modes can be selected for room central heating: automatic or temporary manual.

  • Automatic [☀️/?]: The room temperature is regulated on two levels Comfort (sun) and Economy (moon) during the day via a program set by the user.
  • Temporary manual [?]: The room temperature is modified momentarily with respect to automatic functioning until the successive passage between Comfort and Economy mode of the automatic program set.

6.1 Automatic Functioning

The Zone Remote Panel allows automatic functioning, in which a program manages the room temperature during the hours of the day. The desired room temperature can be adjusted onto two independent levels: Comfort [☀️] and Economy [?] in the Zone Setpoint menu, whose distribution throughout the day or the week is managed by hourly programming. Press the button until the icon switches-on on the display. The Zone Remote Panel is factory set with a standard program shown below. If this should not satisfy requirements, it is possible to modify it as described in the chapter relative to programming.

Figure 5 displays icons representing operating modes: Stand-by/Antifreeze [❄️], Summer [?], Summer with Cooling [❄️/?], Winter [?/?].

The system is designed to function on Comfort and Economy temperature levels depending on the hour program set. Therefore also during operation on Economy level, if the room temperature measured is below that set, the appliance may function.

6.2 Temporary Manual Functioning

If the room temperature is changed in automatic operation [☀️/?], Temporary manual operation is activated. In this mode, the room temperature will be regulated to the value set until the next switch-on or switch-off phase of the automatic program set. The forced automatic function can be interrupted by simply changing the operation mode.

7. Summer Mode with Cooling Functions

With the Zone Remote Panel in Summer mode with Cooling [❄️/?], the production of DHW, room central cooling and room dehumidifier are enabled. Two main functioning modes can be selected: automatic or temporary manual. These operating modes are similar to those found in the WINTER mode.

The room dehumidification function is activated automatically according to the humidity setpoint set on the Zone Remote Panel (see Zone Setpoint Menu) and the relevant room humidity value measured by the device. The room dehumidification function is a manual function, i.e. it does not depend on the set time program.

8. Operation with External Probe

When the external probe is enabled [?️] in the appliance, the symbol is shown on the Zone Remote Panel display. From this moment, the system's flow temperature for room central heating is calculated depending on the external temperature measured. It is possible to change the operation curve by using the main switch [button-confirm] and changing the external probe offset (Ref. 1 Fig. 4).

9. Time and Program Menu

  • Time slots: The Zone Remote Panel allows you to set 4 calendars with up to 4 slots. During the set time slots, the system will be in Comfort mode [☀️]. After setting these 4 calendars it is possible to associate them to the various days of the week. Press the "Menu" button [button-menu]. Select by pressing the main selector [button-confirm] the item "Time and program", then "Time slots". Once you have accessed the menu, adjust the various items highlighted by turning the main switch. Set the value and save it by pressing the main switch. Each time it is saved, it moves to the next item. After programming, press "Conferma" (Confirm) [button-confirm].
  • Time programme: Time slots are assigned to Zones in these menus (Calendars from 1 to 4) to the associated Zone, both sanitary and heating. You can assign the calendar to a single day or to a group of days (single day, Monday - Friday, Saturday Sunday, Monday - Saturday, Monday - Sunday). Therefore each day may be personalised with 4 different operating programs. For convenient selection, the bottom part displays the graphics of the relevant calendar being selected.
  • Holiday programme: In case of need it is possible to suspend the operation of the system for a certain period, if the device to which it is connected has this function. In the menu you can enter the start and end dates of the holiday.

10. Settings Menu

By pressing the "Menu" button [button-menu] you can access a list of menu items to customize the Zone Remote Panel. To browse the menus, which can be accessed by pressing the relative "RH" or "LH" context buttons [button-right]/[button-left], scroll through the sub-menus displayed by turning the main switch [button-confirm]. Press the said selector to select the one highlighted. By pressing repeatedly, you can scroll down the menu levels and go back to a previous level by pressing the "Indietro" (Back) [button-back] context button. To exit the menu completely, press the "Esci" (Exit) [button-exit] button, which will take you back to the initial page of normal operation. To confirm the parameter change, press the main switch [button-confirm].

Note: The default values depend on the device connected to the Zone Remote Panel, except those indicated below.

Note: Parameters not managed by the device connected to the Zone Remote Panel are displayed with the symbol "--".

Key Menus:

  • Setpoint Zone Menu: Defines operating parameters for zone management, including Set comfort heat [☀️], Set economy heat [?], Set comfort cool [❄️], Set economy cool [❄️], Set humidity cool [?], Set flow, and Offset.
  • Setpoint DHW Menu: Defines parameters for domestic hot water management, including Set Comfort [☀️], Set Economy [?], Set Manual DHW Temperature, Enable DHW time slots, and Antilegio function.
  • Time and program menu: Defines time ranges for operation (Time slots), schedules Zone programs, schedules DHW programs, and holiday scheduling.
  • Information Menu: Displays system operating data such as External temperature [?️], Set system temp. calc., Room Temp., Room Humidity, Flow temperature, Return temperature, DHW Setpoint, DHW Temp., and firmware versions.
  • User Menu: Allows disabling the heat pump (HP Disable) and dehumidification (Dehumidification Disable) according to time slots, and setting CH min. set and Max cooling setpoint.
  • Service Menu: Password-protected menu for qualified technicians, including Definition of zone, System defining (e.g., Enable Room thermostat, Room probe correction, Enable dew point), Device configuration (e.g., Slave address, Baud rate), and Factory settings restore.
  • Language Menu: Defines the Zone Remote Panel operation language (e.g., ITA, ENG, POL).

11. Technical Characteristics

  • Dimensions (LxHxD): 128 x 98 x 36 mm
  • Power Supply: 24V nominal (12V...24V)
  • Maximum input: max 10 mA (max 250 mW)
  • Functioning room temperature: 0 - +50°C
  • Warehouse temperature: -10 - +60°C
  • Protection rating according to EN 60730: Class II
  • Protection rating according to EN 60529: IP 20
  • Power supply electrical features: polarised bipolar cable
  • Communication electrical features: polarised bipolar cable
  • Connection cable max. length: 50 m (with cable 2x0.75mm²; 0.5 mm² min - 1.5 mm² max)
  • Precision indication room temp.: +/- 0.5°C at 25°C*
  • Humidity probe accuracy: +/- 10%*
  • Clock indication diversion: +/- 15 minutes/year

* The indications of the room temperature and humidity can be affected by the point of installation of the Zone Remote Panel (e.g. hot wall, cold wall, height from the ground, etc.).

11.1 Product Sheet

In compliance with Regulation 811/2013, the class of the temperature control device is:

  • Class V: +3% contribution to room central heating seasonal energy efficiency (Zone Remote Panel)
  • Class VI: +4% contribution to room central heating seasonal energy efficiency (Zone Remote Panel combined with external probe)
Models: 3.030863 Zone Remote Panel, 3.030863, Zone Remote Panel, Remote Panel, Panel

File Info : application/pdf, 24 Pages, 1.01MB

PDF preview unavailable. Download the PDF instead.

Pannello-remoto-di-zona-EXP-1045256 01D2J ?ef= ENG

References

Adobe PDF Library 16.0.3 Adobe InDesign 17.0 (Windows)

Related Documents

Preview Immergas Modulating Room Thermostat Kit 3.015245 Installation and Operation Manual
Detailed instructions for installing and operating the Immergas Modulating Room Thermostat Kit (Model 3.015245), including general warnings, installation guidelines, electrical connections, functions, and troubleshooting.
Preview Immergas Heat Pumps: AUDAX TOP ErP, MAGIS PRO ErP, RAPAX ErP - Product Guide
Comprehensive guide to Immergas's advanced heat pump solutions, including AUDAX TOP ErP (mono-bloc air-to-water), MAGIS PRO ErP (split-type air-to-water), and RAPAX ErP (heat pump water heaters). Details product features, technical specifications, energy efficiency (ErP/ELD compliance), installation considerations, and accessories for sustainable climate control and domestic hot water.
Preview Immergas Dominus V2 Remote Control Application Installation Guide
Comprehensive guide for installing and using the Immergas Dominus V2 remote control application to manage your Immergas generator. Includes technical specifications, wiring diagrams, and setup instructions.
Preview IMMERGAS, SPLENDID, RADSON, SANICA: Κατάλογος Θέρμανσης, Ψύξης & Υδραυλικών
Ανακαλύψτε μια ολοκληρωμένη γκάμα προϊόντων θέρμανσης, ψύξης και υδραυλικών από κορυφαίους κατασκευαστές όπως IMMERGAS, SPLENDID, RADSON και SANICA. Ο κατάλογος περιλαμβάνει χαλύβδινα θερμαντικά σώματα panel, επίτοιχους λέβητες συμπύκνωσης, αντλίες θερμότητας, συστήματα VRF και μια ευρεία ποικιλία αξεσουάρ.
Preview Immergas CAR V2 Modulating Remote Control User Manual
User manual for the Immergas CAR V2 modulating remote control, detailing installation, operation, programming, and troubleshooting.
Preview Immergas HERCULES Condensing Boilers: High Comfort, Performance & Hydrogen Ready
Explore the Immergas HERCULES range of floor-standing condensing boilers with integrated stainless steel tanks. Featuring high sanitary hot water production, advanced technology, efficiency, and Hydrogen Ready capabilities.
Preview Immergas VICTRIX OMNIA User Manual: Installation, Use, and Maintenance Guide
Comprehensive user manual for the Immergas VICTRIX OMNIA condensing boiler. Includes installation instructions, operating guidelines, maintenance procedures, technical specifications, and troubleshooting for optimal performance and safety.
Preview Immergas Victrix Tera V2 Series Condensing Boilers: User, Installation, and Maintenance Manual
Comprehensive guide for Immergas Victrix Tera V2 series condensing boilers (V28, V32, V38 EU). Covers installation, operation, maintenance, and technical details for installers, users, and technicians.