R. STAHL LS Miniature Circuit Breaker
Model: 8530/1-MCB-STA102-B16-500-3
Article No. 272126
Key Features
- Trennfunktion nach EN 60947-2 (Disconnecting function according to EN 60947-2)
- Energiebegrenzungsklasse 3 (Energy limiting class 3)
- Simple replacement or expansion of your system through modular circuit breaker design
- Easy installation by snapping onto mounting rails in Ex e enclosures
- Fixed thermal and magnetic trip units
- Ergonomically shaped operating lever ensures safe switching on and off
- Protection against re-engagement during maintenance using padlocks (accessories)
Product Overview
The R. STAHL 8530 series miniature circuit breakers offer excellent current limitation for short circuits and a high breaking capacity of 10, 15, or 25 kA. This results in reduced stress on conductors and higher selectivity to upstream fuses. The components are modularly designed and available in 1- to 4-pole versions for rated currents from 0.5–63 A. The maximum installation capacity is 4.5 module widths (TE).
Technical Data
Explosion Protection
Parameter | Value |
---|---|
Einsatzbereich (Zonen) (Area of Use (Zones)) | 1, 2 |
Einsatzbereich (Zonen) Hinweis (Area of Use (Zones) Note) | Usable in Zone 21 / 22 when protected by enclosure Ex tb / tc |
IECEx Bescheinigung Gas (IECEx Certificate Gas) | IECEx FMG 19.0029U |
IECEx Gasexplosionsschutz (IECEx Gas Explosion Protection) | Ex db eb IIC Gb |
ATEX Bescheinigung Gas (ATEX Certificate Gas) | FM19ATEX0191U |
ATEX Gasexplosionsschutz (ATEX Gas Explosion Protection) | II 2 G Ex db eb IIC Gb |
Bescheinigungen (Certificates) | ATEX (FM), Brazil (ULB), IECEx (FM), People's Republic of China (CQST) |
Konformitätserklärungen (Conformity Declarations) | Conformity Certificate (ATEX), People's Republic of China (CCC) |
Electrical Data
Parameter | Value |
---|---|
Bemessungsbetriebsspannung AC (Rated operating voltage AC) | 230/400 V |
Bemessungsbetriebsstrom (Rated operating current) | 16 A |
Frequenz (Frequency) | 50/60 Hz |
Bemessungsschaltvermögen (Rated breaking capacity) | 10 kA |
Elektrische Lebensdauer (Electrical service life) | 2 x 10⁴ |
Mechanische Lebensdauer (Mechanical service life) | 2 x 10⁴ |
1. Hilfsfunktion (1st Auxiliary function) | Auxiliary contact 1 changeover + fault signal contact 1 changeover |
Bemessungsspannung 1. Hilfsfunktion AC (Rated voltage 1st Auxiliary function AC) | 230 V |
Max. Bemessungsstrom 1. Hilfsfunktion (Max. rated current 1st Auxiliary function) | 2 A |
2. Hilfsfunktion (2nd Auxiliary function) | - |
Max. Spannung 2. Hilfsfunktion DC (Max. voltage 2nd Auxiliary function DC) | - |
Auslösecharakteristik (Trip characteristic) | B |
Polzahl (Number of poles) | 2-pole |
Umgebungsbedingungen (Environmental Conditions)
Parameter | Value |
---|---|
Umgebungstemperatur (Ambient temperature) | -40 °C ... 70 °C (-40 °F ... 158 °F) |
Umgebungstemperatur Hinweis (Ambient temperature note) | Deviating ambient temperatures are available on request based on current certificates. |
Mechanische Daten (Mechanical Data)
Parameter | Value |
---|---|
Schutzart (IP) (IEC 60529) (Degree of protection (IP) (IEC 60529)) | IP2X |
Gehäusematerial (Housing material) | Thermoplast |
Anschlussquerschnitt min. (Connection cross-section min.) | 1.5 mm² |
Anschlussquerschnitt max. (Connection cross-section max.) | 25 mm² |
Anschlussquerschnitt AWG min. (Connection cross-section AWG min.) | 16 AWG |
Anschlussquerschnitt AWG max. (Connection cross-section AWG max.) | 4 AWG |
Anschlussquerschnitt 2 min. (Connection cross-section 2 min.) | 1.5 mm² |
Anschlussquerschnitt 2 max. (Connection cross-section 2 max.) | 10 mm² |
Anschlussquerschnitt 2 AWG min. (Connection cross-section 2 AWG min.) | 16 AWG |
Anschlussquerschnitt 2 AWG max. (Connection cross-section 2 AWG max.) | 8 AWG |
Anschlussquerschnitt HIKO min. (Connection cross-section HIKO min.) | 0.5 mm² |
Anschlussquerschnitt HIKO max. (Connection cross-section HIKO max.) | 4 mm² |
Anschlussquerschnitt HIKO AWG min. (Connection cross-section HIKO AWG min.) | 18 AWG |
Anschlussquerschnitt HIKO AWG max. (Connection cross-section HIKO AWG max.) | 14 AWG |
Anzugsdrehmoment min. (Tightening torque min.) | 2 N·m |
Anzugsdrehmoment max. (Tightening torque max.) | 3 N·m |
Anschlussquerschnitt Hinweis (Connection cross-section note) | 2-conductor connection (upper and lower chamber simultaneously): Max. 16/10 mm² for upper and lower chamber (A cross-section difference between the upper and lower chamber may be clamped). The permissible combinations of connection cross-sections can be found in the operating manual. |
Breite (Width) | 83 mm (3.27 in) |
Länge (Length) | 165 mm (6.5 in) |
Einbautiefe (Mounting depth) | 138.3 mm (5.44 in) |
Gewicht (Weight) | 1.3 kg (2.867 lb) |
Montage / Installation
Parameter | Value |
---|---|
Anzugsdrehmoment (Tightening torque) | 2-3 N·m |
Anzugsdrehmoment Ibf in (Tightening torque lbf in) | 17.7 ... 26.6 lbf-in |
Anzugsdrehmoment Hilfskontakt (Tightening torque auxiliary contact) | 0.4-0.6 Nm |
Anzugsdrehmoment Hilfskontakt Ibf in (Tightening torque auxiliary contact lbf in) | 3.5 ... 5.3 lbf in |
Technical Drawings and Dimensions
Trip Time Curve: A graph showing tripping time in seconds versus multiples of rated current (I/In) for characteristic B, with curves for cold state and typical operation.
Dimensions:
- Overall Width: 83 mm [3.27 in]
- Overall Length: 165 mm [6.50 in]
- Mounting Depth: 138.3 mm [5.44 in]
- Unit Width: 8530/1; 3 module widths
Accessories
Lock-out/Tag-out Device (Fourfold)
A Lock-out / Tag-out device for individually locking the component, allowing the use of up to 4 cylinder locks.
- Article No.: 227232
Mounting Set
A mounting set for attaching the component to the mounting plate without a top-hat rail.
- Article No.: 276618
Cylinder Lock
For locking (shackle Ø 3)
- Article No.: 107115
Note on Diagrams
The diagrams provided are for illustrative purposes only and are not binding. Technical data, dimensions, weights, constructions, and delivery options are subject to change without notice.