R. STAHL LS Miniature Circuit Breaker

Model: 8530/1-MCB-STA101-B16-500-2

Article No.: 293980

Key Features

Product Overview

The R. STAHL 8530 series miniature circuit breakers offer excellent current limiting for short circuits and a high breaking capacity of 10, 15, or 25 kA. This results in reduced stress on conductors and high selectivity with upstream fuses. The components are modularly designed and available in 1- to 4-pole versions for rated currents from 0.5–63 A. The maximum installation capacity is 4.5 module widths (TE).

Technical Data

Explosion Protection

FeatureSpecification
Area of application (zones)1, 2
Area of application (zones) noteUsable in Zone 21 / 22 with protection by enclosure Ex tb / tc
IECEx Certificate GasIECEx FMG 19.0029U
IECEx Gas explosion protectionEx db eb IIC Gb
ATEX Certificate GasFM19ATEX0191U
ATEX Gas explosion protectionII 2 G Ex db eb IIC Gb
CertificationsATEX (FM), Brazil (ULB), IECEx (FM), People's Republic of China (CQST)
Declarations of conformityConformity certification (ATEX)

Electrical Data

FeatureSpecification
Rated operating voltage AC230 V
Rated operating current16 A
Frequency50/60 Hz
Rated breaking capacity10 kA
Electrical service life2 x 10⁴
Mechanical service life2 x 10⁴
Auxiliary function1 changeover auxiliary contact + 1 fault signal changeover contact
Rated voltage 1st auxiliary function AC230 V
Max. rated current 1st auxiliary function2 A
2nd auxiliary function-
Max. voltage 2nd auxiliary function DC-
Trip characteristicB
Number of poles1-pole

Environmental Conditions

FeatureSpecification
Ambient temperature-40 °C ... 70 °C
Ambient temperature (Fahrenheit)-40 °F ... 158 °F
Ambient temperature noteDeviating ambient temperatures available upon request based on current certificates.

Mechanical Data

FeatureSpecification
Protection type (IP) (IEC 60529)IP2X
Housing materialThermoplast
Conductor cross-section min.1.5 mm²
Conductor cross-section max.25 mm²
Conductor cross-section AWG min.16 AWG
Conductor cross-section AWG max.4 AWG
Conductor cross-section 2 min.1.5 mm²
Conductor cross-section 2 max.10 mm²
Conductor cross-section 2 AWG min.16 AWG
Conductor cross-section 2 AWG max.8 AWG
Conductor cross-section HIKO min.0.5 mm²
Conductor cross-section HIKO max.4 mm²
Conductor cross-section HIKO AWG min.18 AWG
Conductor cross-section HIKO AWG max.14 AWG
Tightening torque min.2 N·m
Tightening torque max.3 N·m
Conductor cross-section note2-conductor connection (upper and lower chamber simultaneously): Upper and lower chamber max. 16/10 mm² (A maximum cross-section difference between the upper and lower chamber may be clamped.) The permitted combinations of conductor cross-sections can be found in the operating manual.
Width65 mm [2.56 in]
Length165 mm [6.5 in]
Installation depth138.3 mm [5.44 in]
Weight1 kg [2.205 lb]

Mounting / Installation

FeatureSpecification
Tightening torque2-3 N·m
Tightening torque lbf·in17.7 ... 26.6 lbf·in
Tightening torque auxiliary contact0.4-0.6 Nm
Tightening torque auxiliary contact lbf·in3.5 ... 5.3 lbf·in

Technical Drawings and Dimensions

Diagrams illustrating the tripping characteristic (Type B) and dimensional drawings of the device are provided. The tripping characteristic shows the relationship between the multiple of the rated current and the tripping time, indicating the device's response to overcurrents. The dimensional drawings provide precise measurements for installation, including width, length, and depth, in both millimeters and inches.