MEAN WELL NTS-300 Series 300W High Reliable True Sine Wave DC-AC Power Inverter
Brand: MEAN WELL
Model Series: NTS-300
Product Description
The MEAN WELL NTS-300 is a 300W highly reliable off-grid true sine wave DC-AC power inverter. It features a digital design with MCU control for streamlined circuitry that quickly responds to environmental changes, enhancing reliability. With a 600W peak power capability, adjustable AC output voltage and frequency, and a wide operating temperature range of -25°C to +65°C, the NTS-300 is suitable for a variety of applications. When combined with batteries, it is ideal for residential, commercial, marine, automobile, mine, construction sites, and remote areas lacking utility power. The output can power fans, TVs, radios, phone chargers, PCs/laptops, lighting, electromechanical tools, communication equipment, power distribution cabinets, outdoor camping equipment, and marine AC power systems.
Key Features
- Compact size and light weight.
- True sine wave output (THD<3%).
- High surge power up to 600W.
- Fanless design for quiet operation.
- AC output voltage and frequency selectable by DIP S.W.
- Low no-load power dissipation (<1.5W max. in standby saving mode).
- Wide operating temperature range: -25°C to +65°C.
- Power ON-OFF remote control capability.
- Front panel indicator for operation status.
- Comprehensive Protections:
- Input: Reverse polarity, DC low alarm, DC low shutdown, Over voltage.
- Output: Short circuit, Overload, Over temp.
- Battery over-discharge protection (Low voltage disconnect).
- Suitable for lead-acid or li-ion batteries.
- Optional carry handle accessory available (Order NO.: Carry handle, sold separately).
- Conformal coating for enhanced durability.
- 3 years warranty.
Applications
- Mobile devices
- Home and office appliances
- Power tools
- Portable equipment
- Vehicles
- Yachts
- Off-grid solar power systems
- Wireless networks
- Telecom or datacom systems
Model Encoding
The model number is structured to define specific configurations:
NTS - 300 - [AC Socket Type] - [DC Input Voltage] - [AC Output Voltage]
- AC output socket: (Type US, EU, CN, AU, UK, UN, GFCI outlet)
- DC input voltage: (12: 12Vdc, 24: 24Vdc, 48: 48Vdc)
- AC output voltage: (1: 100/110/115/120Vac, 2: 200/220/230/240Vac)
- Rated wattage: 300W
- Series name: NTS
Example: NTS-300-112 US indicates a 300W inverter with a US AC socket, 12Vdc input, and 110Vac output.
Specifications
MODEL NO. | NTS-300-112 | NTS-300-124 | NTS-300-148 | NTS-300-212 | NTS-300-224 | NTS-300-248 | ||
---|---|---|---|---|---|---|---|---|
RATED POWER (Continuous) | 300W | |||||||
OVER RATED POWER (3 Min.) | 345W | |||||||
PEAK POWER (10 Sec.) | 450W | |||||||
SURGE POWER (30 Cycles) | 600W | |||||||
AC OUTPUT | Default setting: 110VAC, 60Hz±0.1Hz | Default setting: 230VAC, 50Hz±0.1Hz | ||||||
AC VOLTAGE | 100/110/115/120Vac selectable by DIP S.W | 200/220/230/240Vac selectable by DIP S.W | ||||||
FREQUENCY | 50/60Hz selectable by DIP S.W | |||||||
WAVEFORM | True sine wave (THD<3%) | |||||||
AC REGULATION | ±3.0% at rated output voltage | |||||||
FRONT PANEL LED | Please refer to page 5 for details. | |||||||
DC INPUT | DC VOLTAGE | 12V | 24V | 48V | 12V | 24V | 48V | |
VOLTAGE RANGE (Typ.) | 10~16.5Vdc | 20~33Vdc | 40~66Vdc | 10~16.5Vdc | 20~33Vdc | 40~66Vdc | ||
DC CURRENT (Typ.) | 30A | 15A | 8A | 30A | 15A | 8A | ||
NO LOAD DISSIPATION (Typ.) | NON-SAVING MODE | 10W (12V), 10W (24V), 12W (48V) | ||||||
SAVING MODE | Default disable, ≤1.2W~1.5W by models @ auto detect AC output load ≤10W will be changed to saving mode. (1.2W, 1.3W, 1.5W respectively) | |||||||
OFF MODE CURRENT DRAW | ≤1mA | |||||||
EFFICIENCY (Typ.) | 90% | 92% | 92% | 92% | 93% | 93% | ||
BATTERY TYPES | Lead Acid or li-ion | |||||||
PROTECTION (DC INPUT) | FUSE (Internal) | 30A*2 | 30A*1 | 10A*2 | 30A*2 | 30A*1 | 10A*2 | |
LOW ALARM | 11±0.3Vdc | 22±0.5Vdc | 44±1Vdc | 11±0.3Vdc | 22±0.5Vdc | 44±1Vdc | ||
LOW SHUTDOWN | 10±0.3Vdc | 20±0.5Vdc | 40±1Vdc | 10±0.3Vdc | 20±0.5Vdc | 40±1Vdc | ||
LOW RESTART | 12.5±0.3Vdc | 25±0.5Vdc | 50±1Vdc | 12.5±0.3Vdc | 25±0.5Vdc | 50±1Vdc | ||
HIGH ALARM | 15.5±0.3Vdc | 31±0.5Vdc | 62±1Vdc | 15.5±0.3Vdc | 31±0.5Vdc | 62±1Vdc | ||
HIGH SHUTDOWN | 16.5±0.3Vdc | 33±0.5Vdc | 66±1Vdc | 16.5±0.3Vdc | 33±0.5Vdc | 66±1Vdc | ||
HIGH RESTART | 15±0.3Vdc | 30±0.5Vdc | 60±1Vdc | 15±0.3Vdc | 30±0.5Vdc | 60±1Vdc | ||
BAT. POLARITY | By internal fuse open | |||||||
PROTECTION (AC OUTPUT) | OVER TEMPERATURE | Protection type: Shut down o/p voltage, re-power on to recover. | ||||||
OUTPUT SHORT | Protection type: Shut down o/p voltage, re-power on to recover. | |||||||
OVER LOAD (Typ.) | 105~115% load for 180 sec., 115%~150% load for 10 sec. Protection type: Shut down o/p voltage, re-power on to recover. | |||||||
GFCI PROCTECTION | None (Only for "GFCI" AC socket, by request). Design refer to UL458. | |||||||
FUNCTION REMOTE CONTROL | Power ON-OFF remote control by front panel dry contact connector (by RELAY); Open: Normal work; Short: Remote off. | |||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +65°C (Refer to "Derating curve") | ||||||
WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -30 ~ +70°C / -22 ~ +158°F, 10 ~ 95% RH non-condensing | |||||||
VIBRATION | 10~500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
SAFETY STANDARDS | CB IEC62368-1, Dekra BS EN/EN62368-1, E13, EAC TP TC 004 approved; Design refer to AS/NZS 62368.1 (Please refer to next page "AC output socket" table for more details); Design refer to UL458 (By request). | |||||||
WITHSTAND VOLTAGE | DC I/P - AC O/P: 3.0KVac; AC O/P - FG: 1.5KVac | |||||||
SAFETY & EMC (Note.4) | EMC EMISSION | Radiated | FCC for 112,124,148 only (expect for Type-UN) - Class A | BS EN/EN55032(CISPR32) for 212,224,248 only (expect for Type-UN) - Class A | ||||
Harmonic Current | BS EN/EN61000-3-2 | |||||||
Voltage Flicker | BS EN/EN61000-3-3 | |||||||
EMC IMMUNITY | ESD | BS EN/EN61000-4-2: Level 3, 8KV air; Level 2, 4KV contact | ||||||
Radiated | BS EN/EN61000-4-3: Level 2, 3V/m | |||||||
Magnetic Field | BS EN/EN61000-4-8: Level 1, 1A/m | |||||||
OTHERS | MTBF | 845.6K hrs min. Telcordia TR/SR-332 (Bellcore); 85.3K hrs min. MIL-HDBK-217F (25°C) | ||||||
DIMENSION | 210*130*55mm (L*W*H) | |||||||
PACKING | 1.3Kg; 8pcs/ 11.4Kg/ 1.74CUFT |
Notes:
- Efficiency, AC regulation and THD are tested by 300W, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.
- All parameters not specified above are measured at rated load, 25°C of ambient temperature and set to factory setting.
- Internal pre-start circuit, the setup time is 8s.
- The power supply is considered as an independent unit, but the final equipment still needs to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on meanwell.com).
Product Liability Disclaimer: For detailed information, please refer to meanwell.com/serviceDisclaimer.aspx.
AC Output Socket Options
MODEL NO. | NTS-300-112 | NTS-300-124 | NTS-300-148 | NTS-300-212 | NTS-300-224 | NTS-300-248 | ||
---|---|---|---|---|---|---|---|---|
Socket type | TYPE-US | TYPE-GFCI | TYPE-UN | TYPE-EU | TYPE-CN | TYPE-UK | TYPE-AU | TYPE-UN |
Country | USA | USA | UNIVERSAL | EUROPE | CHINA | U.K. | AUSTRALIA | UNIVERSAL |
Certificate | CB, FCC, DEKRA | None | CB, E13, EAC, CE | CB, FCC | CB, E13, DEKRA, EAC, CE | CB, E13 | CB, E13, DEKRA, EAC, CE | E13, EAC |
Derating Curves
Ambient Temperature Derating: The inverter operates at 100% load capacity from -25°C up to 40°C. Beyond 40°C, the load capacity gradually derates, reaching approximately 60% at 65°C.
DC Input Voltage Derating: The derating curve illustrates load capacity based on DC input voltage. For 12Vdc models, full load is supported between approximately 10.5Vdc and 16.5Vdc. For 24Vdc models, this range is 21Vdc to 33Vdc. For 48Vdc models, it is 42Vdc to 66Vdc. Operation outside these ranges may result in reduced output or shutdown.
Remote ON-OFF Control
The inverter can be controlled remotely via a dry contact connector on the front panel.
Remote ON-OFF State | AC Output Status |
---|---|
Open (Pin 1 & 2) | Power Inverter ON |
Short (Pin 1 & 2) | Power Inverter OFF |
AC Output Voltage, Frequency, and Power Saving Mode Selection
Users can adjust the AC output voltage, frequency, and power saving mode using DIP switches (SW1-SW4) located on the panel. Factory settings are typically 110Vac/60Hz or 230Vac/50Hz.
SW1 | SW2 | SW3 | SW4 | Setting |
---|---|---|---|---|
OFF | OFF | ON | ON | AC Output: 100Vac or 200Vac; Frequency: 50Hz; Power Saving: Saving mode |
OFF | ON | ON | OFF | AC Output: 110Vac or 220Vac; Frequency: 60Hz; Power Saving: Non-Saving mode |
ON | OFF | OFF | ON | AC Output: 115Vac or 230Vac; Frequency: 50Hz; Power Saving: Saving mode |
ON | ON | OFF | OFF | AC Output: 120Vac or 240Vac; Frequency: 60Hz; Power Saving: Non-Saving mode |
Note: The table above details specific combinations for voltage, frequency, and power saving mode selection.
LED Status Indicators
The front panel LEDs provide status information:
Normal Work:
Status | Green | Orange | Red |
---|---|---|---|
System Status | System check | Remote off | Abnormal Status (See table below) |
Inverter Status | Inverter OK | Saving mode |
DC Input Levels:
Status | Green | Orange | Red |
---|---|---|---|
12Vdc Input | 12.5~15.5Vdc | 11~12.5Vdc | <11Vdc or >15.5Vdc |
24Vdc Input | 25~31Vdc | 22~25Vdc | <22Vdc or >31Vdc |
48Vdc Input | 50~62Vdc | 44~50Vdc | <44Vdc or >62Vdc |
Load Levels:
Status | Green | Orange | Red |
---|---|---|---|
Load | <40% load | 40~80% load | >80% load |
Abnormal Status:
LED Indicator | Abnormal Indication |
---|---|
Status (LEDs for DC Input and Load) | Output overload or AC output short circuit |
DC Input (LEDs for DC Input and Load) | Abnormal DC voltage |
Status (LEDs for DC Input and Load) | Over temperature or Fan lock |
DC Input (LEDs for DC Input and Load) | Inverter fail |
LED Indicators: Light = Steady light, Light off = Off, Flash = Flashing.
Mechanical Specification
Dimensions are in millimeters (mm) with a tolerance of ±1mm.
Overall Dimensions: 210mm (Length) x 130mm (Width) x 55mm (Height).
DC Input Side: Features a chassis bonding lug and DC input terminals (+/-). A warning states: "Reverse Polarity Will Damage The Unit." Includes a remote control switch (R.C SW).
AC Output Side: Shows different AC output socket types (Type-EU, Type-US, Type-CN, Type-UN) with their respective terminal layouts.
R.C Connector: Uses JST B-XH or equivalent for remote control.
- Remote Control Pin Configuration:
- Pin 1,2 Open: Normal work
- Pin 1,2 Short: Remote off
Mating Housing: JST XHP or equivalent.
Terminal: JST SXH-001T or equivalent.
Accessory List
The following accessories may be available:
MW's Order No. | Item | Quantity |
---|---|---|
Carry Handle | Handle | 1 |
Foot pad | 4 | |
Screw (M4*2) | 2 |
Note: Carry handle is an optional accessory. The power inverter and pull handle should be ordered separately.
Typical Application Scenarios
The NTS-300 inverter is versatile and can be integrated into various systems:
1. Household Application:
Depicts a house powered by a battery bank and the NTS series inverter, providing AC power to household appliances like a fan and TV. It implies integration with solar power or other DC sources.
2. Marine Application:
Illustrates a yacht system where the NTS series inverter is used. It shows utility input (shore power), an AC/DC battery charger, a battery bank, and the inverter supplying AC power to onboard equipment.
3. RV Application:
Shows a recreational vehicle (RV) equipped with an AC/DC battery charger, a battery bank, and the NTS series inverter to provide AC power for various appliances and systems within the vehicle.
Installation Manual
For detailed installation instructions, please refer to the official MEAN WELL website: