1700W High Reliable True Sine Wave DC-AC Power Inverter - NTS-1700 Series
Product Description
The NTS-1700 is a 1700W, highly reliable off-grid true sine wave DC-AC power inverter. It features a digital design with MCU control for responsive circuitry, a high-quality fan with low acoustic noise, and a peak power capability of 3400W. The inverter offers adjustable AC output voltage and frequency, operates within a wide temperature range of -25°C to +70°C, and includes comprehensive protection features. It is suitable for use in residential, commercial, marine, automobile, mining, construction sites, and remote areas lacking utility power. The output can power various devices including fans, TVs, radios, phone chargers, PCs, laptops, lighting, induction stoves, air conditioners, electromechanical tools, communication equipment, and more.
Features
- True sine wave output (THD<3%)
- High surge power up to 3400W
- Temperature controlled cooling fan
- AC output voltage and frequency selectable by DIP SW
- No load dissipation <1.5W at standby saving mode
- -25℃~+70℃ wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections: Input (Reverse polarity, DC low alarm, DC low shutdown, Over voltage); Output (Short circuit, Overload, Over temp.); Battery (Over discharge protection - low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Optional remote controller (IRC1, IRC2, IRC3) available
- Support RS-232 communication
- Optional carry handle accessory available
- Conformal coating
- 3 years warranty
Applications
- Home and office appliance
- Power tools
- Portable equipment
- Vehicle
- Yacht
- Off-grid solar power system
- Wireless network
- Telecom or datacom system
Model Encoding
The model number follows the structure: NTS - 1700 - [AC Output Socket Type] [DC Input Voltage] [AC Output Voltage]
- AC output socket: US, EU, CN, AU, UK, UN, GFCI outlet
- DC input voltage: 12: 12Vdc, 24: 24Vdc, 48: 48Vdc
- AC output voltage: 1: 100/110/115/120Vac, 2: 200/220/230/240Vac
Specifications
General
Parameter | NTS-1700-112, -124, -148 (US, GFCI, UN) | NTS-1700-212, -224, -248 (EU, CN, AU, UK, UN) |
---|---|---|
RATED POWER (Continuous) | 1500W | 1700W |
OVER RATED POWER (3 Min.) | 1750W | 2000W |
PEAK POWER (10 Sec.) | 2200W | 2550W |
SURGE POWER (30 Cycles) | 3000W | 3400W |
BATTERY TYPES | Lead Acid or Li-ion |
AC Output
Parameter | NTS-1700-112, -124, -148 (US, GFCI, UN) | NTS-1700-212, -224, -248 (EU, CN, AU, UK, UN) |
---|---|---|
AC VOLTAGE | Default setting 110VAC; 100/110/115/120Vac selectable by DIP S.W | Default setting 230VAC; 200/220/230/240Vac selectable by DIP S.W |
FREQUENCY | Default setting 60±0.1Hz; 50/60Hz selectable by DIP S.W | Default setting 50±0.1Hz; 50/60Hz selectable by DIP S.W |
WAVEFORM | True sine wave (THD<3%) | |
AC REGULATION | ±3.0% at rated input voltage |
DC Input
Parameter | 12Vdc | 24Vdc | 48Vdc | 12Vdc | 24Vdc | 48Vdc |
---|---|---|---|---|---|---|
DC VOLTAGE | 12Vdc | 24Vdc | ||||
VOLTAGE RANGE (Typ.) | 10~16.5Vdc | 20~33Vdc | 40~66Vdc | 10~16.5Vdc | 20~33Vdc | 40~66Vdc |
DC CURRENT (Typ.) | 150A | 75A | 37.5A | 170A | 85A | 42.5A |
NO LOAD DISSIPATION (SAVING MODE)(Typ.) | 1.2W | 1.4W | 1.5W | 1.2W | 1.4W | 1.5W |
OFF MODE CURRENT DRAW | <1mA | |||||
EFFICIENCY (Typ.) | 89% | 90% | 91% | 89% | 92% | 93% |
Protections
Category | Parameter | 12Vdc Input | 24Vdc Input | 48Vdc Input |
---|---|---|---|---|
DC INPUT | ALARM (Low) | 11±0.3Vdc | 22±0.5Vdc | 44±1Vdc |
SHUTDOWN (Low) | 10±0.3Vdc | 20±0.5Vdc | 40±1Vdc | |
ALARM (High) | 15.5±0.3Vdc | 31±0.5Vdc | 62±1Vdc | |
SHUTDOWN (High) | 16.5±0.3Vdc | 33±0.5Vdc | 66±1Vdc | |
AC OUTPUT | OVER TEMPERATURE / OUTPUT SHORT | Protection type: Shut down o/p voltage, re-power on to recover | ||
OVER LOAD (Typ.) | 105~115% load for 180 sec., 115%~150% load for 10 sec. Protection type: Shut down o/p voltage, re-power on to recover | |||
BAT. POLARITY | By internal fuse open | |||
CIRCUIT BREAKER (GFCI AC SOCKET) | 15A (for GFCI socket) / 10A (for GFCI socket) | |||
GFCI PROTECTION | UL458 (Only for "GFCI" AC socket, by request) |
Environment
Parameter | Value |
---|---|
WORKING TEMP. | -25~+70℃ (Refer to "Derating curve") |
WORKING HUMIDITY | 20% ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -30~+70℃ / -22~ +158°F, 10~95% RH non-condensing |
VIBRATION | 10~500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes |
Safety & EMC
Category | Parameter | Standard | Test Level / Note |
---|---|---|---|
EMC EMISSION | Radiated | FCC (for 112, 124, 148 only) / BS EN/EN55032 (CISPR32) (for 212, 224, 248 only) | Class A |
Harmonic Current | BS EN/EN61000-3-2 | - | |
Voltage Flicker | BS EN/EN61000-3-3 | - | |
EMC IMMUNITY | ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact |
Radiated | BS EN/EN61000-4-3 | Level 2, 3V/m | |
Magnetic Field | BS EN/EN61000-4-8 | Level 1, 1A/m | |
SAFETY STANDARDS | CB IEC62368-1, Dekra BS EN/EN62368-1, UL458, E13, EAC TP TC 004, AS/NZS 62368.1 approved | ||
WITHSTAND VOLTAGE | DC I/P - AC O/P: 3.0KVac; AC O/P - FG: 1.5KVac |
Mechanical Specification
Parameter | Value |
---|---|
DIMENSION (L*W*H) | 400*184*70mm |
WEIGHT | 4.63Kg |
PACKING | 2pcs/ 12Kg/ 1.76CUFT |
R.C Connector | JST B-XH or equivalent |
Remote Control Pinout | Pin 1,2 Open: Normal work; Pin 1,2 Short: Remote off |
Remote Port Connector (RJ11) | Assignment: DB9 (Pin 2=Rx, Pin 3=GND, Pin 4=Tx) |
AC Output Socket Types
MODEL NO. | NTS-1700-112 | NTS-1700-124 | NTS-1700-148 | NTS-1700-212 | NTS-1700-224 | NTS-1700-248 | ||
---|---|---|---|---|---|---|---|---|
Socket type | TYPE-US | TYPE-GFCI | TYPE-UN | TYPE-EU | TYPE-CN | TYPE-UK | TYPE-AU | TYPE-UN |
Country | USA | USA | UNIVERSAL | EUROPE | CHINA | U.K. | AUSTRALIA | UNIVERSAL |
Certificate | CB FC [DEKRA] | CB FC [DEKRA] | None | CB [E13] [EAC] [CE] | CB [E13] [EAC] [CE] | CB [E13] [EAC] [CE] | CB [E13] [EAC] [CE] | CB [E13] [EAC] [CE] |
Derating Curve
The derating curve illustrates the relationship between ambient temperature and the maximum load percentage the inverter can handle. For DC input voltage, specific derating is shown for 10Vdc, 20Vdc, and 40Vdc inputs across their respective operating ranges.
Ambient Temperature Derating: The inverter can operate at 100% load up to approximately 40°C. Load capacity decreases linearly from 40°C to 70°C, reaching about 50% load at 70°C.
DC Input Voltage Derating: Specific derating curves are provided for 12Vdc, 24Vdc, and 48Vdc input voltages, showing load capacity relative to input voltage levels.
Remote Control and Communication
Remote Controller (Accessory)
Optional remote controllers (IRC1, IRC2, IRC3) serve as monitoring and control units. They decode RS-232 signals from the inverter and display information on digital meters. LED indicators on the controllers show:
- Green LED: ON
- Orange LED: OFF
- Red LED: Abnormal Status
- Orange Flash LED: Power Saving Mode
For more details, refer to: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1
RS-232 Communication
The inverter's internal data can be accessed via RS-232 communication. The required communication cable (RJ11-RS232) has order number DS-RJ11-RS232 and must be ordered separately.
For more details, refer to: http://www.meanwell.com/manual.html
Remote ON-OFF Control (Built-in)
The inverter features a built-in remote ON-OFF control via the remote port. A dry contact connection is used:
- Open connection: Power inverter ON (Normal work)
- Short connection: Power inverter OFF (Remote off)
DIP Switch Settings
The inverter's AC output voltage, frequency, and power saving mode can be adjusted using DIP switches (SW1-SW4) located on the panel. Factory settings are typically 110Vac/60Hz.
SW1 | SW2 | SW3 | SW4 | Setting |
---|---|---|---|---|
OFF | OFF | OFF | OFF | 100Vac or 200Vac, 60Hz, Non-Saving mode |
OFF | ON | OFF | ON | 110Vac or 220Vac, 60Hz, Saving mode |
ON | OFF | ON | OFF | 115Vac or 230Vac, 50Hz, Non-Saving mode |
ON | ON | ON | ON | 120Vac or 240Vac, 50Hz, Saving mode |
LED Status Indicators
The front panel includes LEDs to indicate the operational status:
Normal Work Status:
- Status LED: Green (Inverter OK)
- Remote LED: Orange (Remote off)
- Saving Mode LED: Orange (Saving mode)
DC Input Status:
- Green LED: Indicates normal voltage range (e.g., 12.5~15.5Vdc for 12V input).
- Orange LED: Indicates a warning voltage range (e.g., 11~12.5Vdc for 12V input).
- Red LED: Indicates a critical voltage condition (e.g., <11Vdc or >15.5Vdc for 12V input).
Load Status:
- Green LED: <40% load
- Orange LED: 40~80% load
- Red LED: >80% load
Abnormal Status Indications:
LED Indicator (Status / DC Input / Load) | Abnormal Indication |
---|---|
Status LED | Output overload or AC output short circuit |
DC Input LED | Abnormal DC voltage |
Load LED | Over temperature or Fan lock |
Status LED | Inverter fail |
LED States: Light (On), Light off, Flash.
Accessory List
Optional accessories are available for the NTS-1700 series:
Communication Cable:
- Order No.: DS-RJ11-RS232
Carry Handle Accessory:
- Order No.: DS-Carry Handle
- Includes: Handle (1 pc), Foot pad (4 pcs), Screw (2 pcs)
Typical Applications
The NTS-1700 series is versatile and suitable for various applications:
- Residential/Office: Illustrates a setup with a Battery Bank, the NTS series Off-Grid DC/AC Inverter, and AC Outlets powering household appliances.
- Marine: Depicts a yacht system including Utility Input (Shore power), an AC/DC Battery Charger, a Battery Bank, the NTS series Off-Grid AC/DC Power Inverter, and AC Outlets.
- Recreational Vehicle (RV): Shows an RV setup with an AC/DC Battery Charger, a Battery Bank, the NTS series Off-Grid DC/AC Inverter, and AC Outlets.
For installation manuals and further details, please refer to: https://www.meanwell.com/manual.html