Aurora EN-BA1XXXMS Series Microwave Sensor LED Batten Installation Guide & Specifications

AURORA

Product Models: EN-BA1222MS, EN-BA1243MS, EN-BA1533MS, EN-BA1563MS, EN-BA1839MS & EN-BA1873MS

Installation Guide

  1. Step 1: Luminaire Overview

    Illustration shows the luminaire with clearly marked ON and OFF switches.

  2. Step 2: Mounting Bracket and Parts

    Diagram shows a mounting bracket, screws, and specific part numbers with dimensions: EN-BA1222, EN-BA1243-965mm, EN-BA1533, EN-BA1563-1265mm, EN-BA1839, EN-BA1873-1529mm. A drill is also depicted.

  3. Step 3: Luminaire Body and Component

    Illustration depicts the luminaire body and a separate rod or tube, possibly for assembly or mounting.

  4. Step 4: Initial Attachment

    Shows a hand pressing the luminaire onto a surface, indicating initial attachment or positioning.

  5. Step 5: Wiring Connections

    Diagram illustrates the wiring process, showing wires being inserted into connectors.

  6. Step 6: Securing the Luminaire

    Shows the luminaire being secured to the mounting surface with screws.

  7. Step 7: Wiring Color Codes

    Wiring diagram showing connections with color codes: Brown for Live (L), Blue for Neutral (N), and Green/Yellow for Earth.

  8. Step 8: Microwave Sensor Detail

    Close-up view of the microwave sensor component on the luminaire.

  9. Step 9: Diffuser Attachment

    Illustration shows a hand clipping the diffuser or cover onto the luminaire, with an audible '[click]' sound effect indicated.

  10. Step 10: Final Luminaire View

    Final view of the luminaire with ON/OFF switches, similar to Step 1.

Microwave Sensor Features

Detection Area

Detection area can be adjusted by selecting combinations on the DIP switches to fit precise applications. Options include 100%, 75%, 50%, and 25%.

Hold Time

This setting determines the time the lamp remains at 100% illumination after no motion is detected. Options include 5 seconds, 30 seconds, 90 seconds, 3 minutes, 20 minutes, and 30 minutes.

Daylight Sensor

The sensor can be set to allow the lamp to illuminate only below a defined ambient brightness threshold. When set to 'Disable' mode, the daylight sensor will switch on the lamp when motion is detected, regardless of ambient light level. Threshold options include 2 lux, 10 lux, 25 lux, and 50 lux (for twilight operation).

Important Installation Information

  • Installation should be carried out in accordance with the current edition of the National Wiring Regulations. Consult a qualified electrician if in doubt.
  • These luminaires are for indoor use only.
  • Maximum Input Voltage: 220-240V AC 50/60Hz.
  • Ensure that ALL electrical connections are tight with no loose strands.
  • Before commencing installation or maintenance, ensure electricity is switched off at the mains.
  • Class I, mains voltage, this luminaire must be earthed.
  • This luminaire is not dimmable.
  • Wiring: Brown - (L) Live, Blue - (N) Neutral, Green/Yellow - Earth.
  • It is not recommended to mix LED circuits with products such as extractor fans due to the sensitive nature of LEDs.
  • This product contains a light source of energy efficiency class D.

Environmental Protection (WEEE)

Waste Electrical & Electronic Equipment Regulations (WEEE) require that products with this marking must not be disposed of with other household or commercial waste. Aurora does not levy any WEEE disposal charges to customers for affected products. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate such products from other waste types and recycle them responsibly at your local facilities. Check with your Local Authority, Recycling Centre, or retailer for recycling advice. If your supplier included a WEEE disposal fee upon purchase, contact them for take-back advice.

Guarantee

This product is guaranteed for a period of 5 years from the date of purchase. The guarantee is invalid in the case of improper use, installation, tampering, removal of the Q.C. date label, installation in an improper working environment, or installation not according to the current edition of the National Wiring Regulations. Should this product fail during the guarantee period, it will be replaced free of charge, subject to correct installation and return of the faulty unit. Aurora does not accept responsibility for any installation costs associated with the replacement of this product. This warranty is in addition to the statutory rights in your country of purchase. Aurora reserves the right to alter specifications without prior notice.

Models: EN-BA1222MS, EN-BA1243MS, EN-BA1533MS, EN-BA1563MS, EN-BA1839MS, EN-BA1873MS, 73W LED Batten, EN-BA1873MS 73W LED Batten, LED Batten

PDF preview unavailable. Download the PDF instead.

EN-BA1222MS.-EN-BA1243MS.-EN-BA1533MS.-EN-BA1563MS.-EN-BA1839MS.-EN-BA1873MS-Instruction-Manual GPL Ghostscript 9.50 Adobe InDesign 14.0 (Macintosh)

Related Documents

Preview Aurora EN-DLB Series LED Downlight Installation Guide and Specifications
Comprehensive installation instructions and technical specifications for Aurora EN-DLB series LED downlights, including wiring diagrams, dimming compatibility (1-10V, DALI), IP44 rating, and Class II safety features.
Preview Aurora EN-HBD Series LED Highbay Lights Installation and Remote Control Guide
Comprehensive guide for installing Aurora EN-HBD series LED Highbay lights, including safety instructions, lens replacement, and operation of the HAISEN microwave sensor remote.
Preview Aurora Flat Panel LED Installation Guide and Product Information
Comprehensive guide for installing Aurora EdgeLite™ flat panel LED lights, covering wiring for dimmable and non-dimmable drivers, along with warranty and environmental compliance details.
Preview Aurora BatPac PRO Range LED Battens - Product Datasheet
Comprehensive datasheet for Aurora's BatPac PRO Range LED Battens. Features include push-clip release, IK08 rating, and various lumen outputs. Details specifications, dimensions, and certifications for these linear lighting solutions.
Preview Aurora EN-LN1230 & EN-LN1540 LED Luminaire Installation Guide
Comprehensive installation guide for Aurora EN-LN1230 and EN-LN1540 LED luminaires, covering surface and suspension mounting, electrical connections, safety information, and warranty details.
Preview Aurora GLS LED Lamp Declaration of Conformity
Official Declaration of Conformity for Aurora GLS LED Lamps, confirming compliance with key EU directives (LVD, EMC, RoHS, WEEE, RED) and relevant harmonized standards.
Preview Aurora EN-BH10 & EN-BH10PIR Installation Guide
Comprehensive installation guide for Aurora EN-BH10 and EN-BH10PIR LED security bulkheads, covering electrical safety, IP65 rating, and warranty information.
Preview Aurora EN-EMBH Emergency Bulkhead Light Installation, Testing, and Maintenance Guide
Comprehensive guide for installing, testing, and maintaining the Aurora EN-EMBH and EN-EMBHL emergency bulkhead lighting fixtures. Includes wiring diagrams, safety instructions, emergency testing procedures, and warranty information.