Frico Elztrip EZ200 Radiant Heater

Original Instructions

General Instructions

Read these instructions carefully prior to installation and use. Keep this manual for future reference. The product may only be used as set out in the assembly and operating instructions. The guarantee is only valid should the product be used in the manner intended and in accordance with the instructions.

Application

The EZ200 is a double panel radiant heater with a clean and simple design that blends well with electrical fittings. It is intended for total and supplementary heating, as well as protection against cold draughts from windows in environments such as department stores, assembly halls, and industrial premises. The recommended installation heights for the heater are shown on the introduction pages. Protection class: IP44.

Operation

The panels have an operating temperature of up to 320 °C and the heat is radiated to cold surfaces. Maximum surrounding temperature is +30 °C.

Mounting

The Elztrip is installed horizontally on ceilings, in armature rails, on cables, or suspended. Standard fittings for mounting are included and are found inside the connection box. If the heater is suspended by wires, use the four mounting points on the heater. The distance between panels should not be greater than the height between the panel and the floor (a < H). For minimum distances, refer to diagrams on introductory pages.

Fig. 1 Mounting: Describes the process of mounting the heater. It involves bending bracket legs approximately 90°, mounting brackets to the ceiling or wire according to dimensional drawings, and then attaching the panel. Clips are used to prevent sliding when mounting on a wire.

Dimensions Table

Item L [mm] A [mm] B [mm] C [mm]
EZ208 683 400 90 193
EZ212 923 600 110 213
EZ217 1221 900 109 212
EZ222 1520 1200 108 212

Positioning and Minimum Distances

Fig. 2 Positioning: Illustrates heater placement, showing that the distance 'a' should be less than height 'H', with an optimal distance of 1.5 - 2 meters. It also indicates a recommended coverage area of 3-10 meters.

Fig. 3 Minimum distances: Shows minimum clearance requirements for installation, particularly concerning flammable materials. The table provides specific distances (A, B, C, D, E) for the EZ200 model.

Minimum Distances Table

EZ200 A [mm] B [mm] C [mm] D [mm] E [mm]
80 150 150 600 1800

Note on Minimum Distances: Text in multiple languages (SE, NO, FR, DE, NL, ES, PL, IT, RU, FI, DK) describes minimum clearances, especially regarding flammable materials.

Electrical Installation

Elztrip is intended for permanent installation and approved for serial connection. Installation must be preceded by an isolator switch with a contact separation of at least 3 mm and performed by a competent electrician in accordance with the latest IEE wiring regulations. Electrical installation is via cable glands in the junction box (2 x Ø20.5 mm). Cable glands must meet protection class requirements. The largest cable diameter for the terminal block is 16 mm². For serial connection, the maximum fuse size is 35A.

Controls

When used as a local space heater according to Ecodesign Regulation (EU) 2015/1188, the product must be supplemented with approved controls. A relaybox RB3 is required for 400V~ products.

Approved Controls

Alternative control methods, such as Building Management Systems (BMS), are possible, but the installer is responsible for ensuring compliance with Ecodesign Regulation (EU) 2015/1188.

Controls for installations not covered by Ecodesign Regulation (EU) 2015/1188

Item number Type HxWxD [mm]
5999 KRT1900 165x57x60
10214 KRTV19 165x57x60

Available Controls (General)

Item number Type HxWxD [mm]
92790 TAP16R 87x87x53
205540 TEP44 87x87x55
93012 RB3 155x87x43
93044 RTX54 82x88x25
205550 SKG30 115x85x40
211780 PDK65 102x70x50

Technical Specifications

Item number Type Heat output [W] Voltage [V] Amperage [A] Max. surface temperature [°C] Dimensions LxHxW [mm] Weight [kg]
11066 EZ208 800 230V~ 3.5 320 683x64x282 4.9
11067 EZ212 1200 230V~ 5.2 320 923x64x282 6.8
11068 EZ217 1700 230V~ 7.4 320 1221x64x282 8.8
11069 EZ222 2200 230V~ 9.6 320 1520x64x282 10.7
11724 EZ20831 800 400V2~ 2.0 320 683x64x282 4.9
11725 EZ21231 1200 400V2~ 3.0 320 923x64x282 6.8
11726 EZ21731 1700 400V2~ 4.3 320 1221x64x282 8.8
11727 EZ22231 2200 400V2~ 5.5 320 1520x64x282 10.7

Glossary of Terms: The document provides translations for technical terms like 'Heat output', 'Voltage', 'Amperage', 'Max. surface temperature', and 'Weight' in multiple languages (EN, SE, NO, FR, DE, NL, ES, PL, IT, RU, FI, DK).

Wiring Diagrams

The document includes various wiring diagrams illustrating different control configurations for the Elztrip EZ200. These include:

Ecodesign Regulation (EU) 2015/1188

The Ecodesign Regulation (EU) 2015/1188 concerning local space heaters applies when an installation is intended to provide thermal comfort for people. It does not apply to heating installations of a more technical nature (e.g., engineering/utility rooms, production processes, frost protection) or installations in vehicles, offshore, or outdoors. Frico products can serve as both local space heaters and for technical heating purposes. The installer is responsible for assessing the applicability of the Ecodesign Regulation. Control solutions for non-compliant installations are listed separately.

Start-up

During first-time use or after a long period of non-use, smoke or odor may occur due to dust or dirt on the element. This is normal and will disappear shortly. A rattling noise may occur the first time panels are used as the surface coating settles. Small clicks can occur in all electrical heating appliances due to material expansion and contraction with temperature changes.

Maintenance

Disconnect the power supply before any service, repair, or maintenance. Ensure the unit is cold. The unit has minimal maintenance requirements as it has no moving parts, but must be kept clean and free from dust and dirt. Handle the product with clean gloves and ensure it is clean before switching on. Presence of aerosols, lacquer, solvents, or dust may cause discoloration. A slight change in color over time is normal; incorrect installation or high ambient temperatures can increase discoloration, but output is unaffected.

Residual Current Circuit Breaker

If an installation is protected by a residual current circuit breaker that trips upon connection, it may be due to moisture in the heating element, especially after periods of non-use or storage in damp environments. This can be rectified by connecting the appliance to the main supply via a socket without a safety cut-out to allow the moisture to evaporate. This drying process can take several hours to days. Periodically running the unit for a short time when not in use can prevent this.

Handling of product at end of working life

This product may contain substances potentially dangerous to the environment. It should not be disposed of with general household waste but delivered to a designated collection point for environmental recycling. Contact local authorities for details.

Safety

CAUTION: Some parts of this product can become very hot and cause burns. Extra attention is needed where children and vulnerable people are present.

Packaging

Packaging materials are chosen with consideration for the environment and are therefore recyclable.

Models: Elztrip EZ200, Elztrip EZ200 Infrared Panel Heaters, Infrared Panel Heaters, Panel Heaters, Heaters

File Info : application/pdf, 16 Pages, 665.55KB

PDF preview unavailable. Download the PDF instead.

MA FRICO EZ200 GB 180919 20190426 193930428 (1)

References

FPDF 1.82

Related Documents

Preview Frico Elztrip EZ200: Installation and Operation Manual
Comprehensive guide to the Frico Elztrip EZ200 local space heater, covering installation, operation, technical specifications, and safety guidelines.
Preview Frico Elztrip EZ200 Installation and User Manual
Comprehensive guide for installing, operating, and maintaining the Frico Elztrip EZ200 radiant heating cassette, including technical specifications, wiring diagrams, and safety information.
Preview Frico Elztrip EZ100 Radiant Heater: Installation, Operation, and Safety Guide
Comprehensive guide for the Frico Elztrip EZ100 radiant heater, covering its features, installation procedures, operational guidelines, safety precautions, and technical specifications. Includes information on Ecodesign regulation compliance.
Preview Frico Elztrip EZ300 Radiant Heater: Installation and Operating Instructions
Comprehensive guide for the Frico Elztrip EZ300 radiant heater, covering installation, operation, safety, technical specifications, and control options. Includes details on Ecodesign regulations and mounting procedures.
Preview Frico IH Infrared Heater: Installation, Operation, and Safety Guide
Comprehensive guide for Frico IH series infrared heaters (IHW and IHF models), covering dimensions, mounting, installation, technical specifications, wiring diagrams, maintenance, and safety instructions. Features detailed descriptions of diagrams and multilingual content translated into English.
Preview Frico Infrasmart IHS20W/B/S24 Infrared Heater User Manual
User and safety instructions for the Frico Infrasmart IHS20W/B/S24 infrared heater, detailing installation, operation, safety precautions, and technical specifications.
Preview Frico Thermozone AD 200 A/E/W Air Curtains - Technical Specifications and Installation Guide
Detailed information on Frico Thermozone AD 200 A/E/W air curtains, including technical specifications, installation instructions, control options, and performance data for ambient, electric, and water-heated models.
Preview FRICO Heating Products Price List - Air Curtains, Heaters, Controls
Official price list from FRICO (Systemair) for heating products as of September 17, 2025. Features air curtains, heaters, fan heaters, convectors, radiators, and control systems with item numbers and descriptions.