Acaia Pearl Model S User Manual

Model: PS003 / PS004

Firmware Version: FW 1.0.005

In the Box

Thank you for choosing one of our scales. The Acaia Pearl Model S is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience. First, check the shipping carton to find the following:

  • Acaia Pearl Model S Coffee Scale
  • Heat Resistant Coaster
  • USB Type-C Charging Cable

Next, follow the instructions in the “Getting Started” chapter in this manual to start using your scale. To take full advantage of the many features of the Pearl Model S, carefully read through this user manual for step-by-step procedures, examples, and other information.

Warning: Incorrect handling of this product could result in personal injury or physical damage.

Scale Overview

Diagram shows a square scale with a weighing pan on top. Below the pan are indicators for charging/low battery on the left and an LED display on the right. A power button is shown on the left side, and a tare button is shown on the right side.

Weighing Pan

Charging / Low Battery Indicator

LED Display

[Power Button]

[Tare Button]

*Note: For the best performance, place the weight in the center of the weighing pan.

Getting Started

Placement

Diagram shows a scale placed on a flat, stable surface.

Select a work surface that is stable, vibration-free and level to place the scale.

Power On / Off

Diagram shows a finger tapping the power button.

Tap the [Power Button] to turn on the scale. Double tap the [Power Button] to turn off the scale.

Tare Weight

Diagram shows a finger tapping the tare button.

Tap the [Tare Button] to tare / zero the weight.

Switch between Grams / Ounces

Diagram shows a finger pressing and holding the tare button.

Press and hold the [Tare Button] to switch between grams / ounces.

Switch Modes

Diagram shows a finger pressing and holding the power button.

Press and hold the [Power Button] to switch modes. Please see the “Mode Introduction” section for more details.

Product Care Information

Battery Charge

  • You can charge the battery by plugging the USB cable into any of the power supplies listed below:
    • A computer
    • A USB wall-charger with an output of 5 volts and 1 amp
    • A DC car-charger with an output of 5 volts and 1 amp
    • A USB-C PD charger supporting 5 volts
  • It takes about 3-4 hours to fully charge the battery from empty. Try not to let the battery completely run out before charging. Charge the battery as needed.
  • A fully charged battery can provide up to 16 hours of working time in normal brightness and up to 40 hours in low brightness mode.
  • To check remaining battery level, see “Battery Level Indicator” section.

Diagram shows a USB-C cable connecting a scale to a power source.

* Note: The Acaia Pearl Model S is equipped with charging protection to prevent the battery from charging under high temperatures. It is normal if the scale does not charge when the surface is hot from brewing coffee. Battery charging function will be enabled once the scale has cooled.

Battery Level Indicator

When the Pearl Model S is powered off, press and hold the [Power Button]. The LED will display [acaia], [Settings], and then the battery percentage.

You can also check the battery level by connecting the Pearl Model S to Acaia Apps.

Calibration

Sequence of four diagrams showing scale display changes during calibration:

  1. Scale display shows "occio". User is instructed to turn on scale and set unit to grams.
  2. User taps Tare button until "CaL" is shown.
  3. User places a standard weight (e.g., 100g) on the scale.
  4. Scale display shows "_End_", indicating calibration is complete.

Using the Acaia Brewguide

Using Brewguide for the First Time

Brewguide is a step-by-step interactive guide to brewing coffee. Simply scan the Acaia Brewguide QR code on the coffee bean bag, and use the Acaia Brewguide app to download the recipe to your Pearl Model S. In the Brewguide app, you can also discover guides created by roasters around the world.

Diagrams illustrate the steps:

  • Download: Download the Brewguide app.
  • Connect: Activate Bluetooth on your phone and connect with the Pearl Model S.
  • Start personalization: Follow the instructions on the Brewguide app.

Using Brewguide on Pearl Model S

Numbered steps with icons:

  1. Search or scan the QR Code to find the Brewguide you need.
  2. Select a brewguide.
  3. Choose “Upload to Pearl S” in the app to send it to the Pearl Model S.
  4. Wait until the Brewguide is sent to the Pearl Model S; this may take up to one minute.
  5. Follow the guide and get brewing!

Available on the App Store

GET IT ON Google Play

Sound Notification

Personalize Sound Notification

The Pearl Model S comes with sound notification to enhance your brewing experience. Hear the weight and time notified at fixed intervals to help you focus on your brewing workflow. You can further personalize Sound Notifications with the choices of voice, sound effect, or turn it off in Advanced Settings:

Timer Notification Sound

Enter Settings Menu and look for [ Timer Notification Sound ] setting. Available options for this setting:

OptionDescription
SoundThe scale notifies with sound effect as a reminder every 10 seconds and 60 seconds once the timer is started.
VoiceThe scale reads out the time every 10 seconds once the timer is started.
Off (default)Sound Notification for timer disabled.

Timer Notification Sound is supported in Dual Display Mode, Espresso Mode, Pour-Over Auto-Start Timer Mode, and Flowrate Mode.

Weight Notification Sound

Enter Settings Menu and look for [ Weight Notification Sound ] setting. Available options for this setting:

OptionDescription
SoundWhen a flow detected, the scale beeps as a reminder every 20 grams or the equivalent at every 0.7 ounces.
VoiceWhen a stable weight is detected, the scale reads out the weight. When a flow is detected, the scale reads out weight increment every 20 grams or the equivalent at every 0.7 ounces.
Off (default)Sound Notification for weight disabled.

Weight Notification Sound is supported in Weighing Only Mode, Dual Display Mode, Espresso Mode, Pour-Over Auto-Start Timer Mode, and Flowrate Mode. Please note that the “Sound” option is not supported in Weighing Only Mode.

Sound Notification Priorities

  1. When the Timer and Weight are both set to Voice, if there is an overlap in notification, the Pearl Model S will prioritize and announce the Weight first, then the Time.
  2. When the Timer and Weight are both set to Sound, if there is an overlap in notification, the Pearl Model S will prioritize the Time and omit the Weight notification.
  3. When the Timer is set to Sound, and Weight is set to Voice, if there is an overlap in notification, the Pearl Model S will prioritize the Time, and omit the Weight notification.

Mode Introduction

Mode 1 - Weighing Only Mode

In the Weighing Only Mode, the scale will only display weight, in either grams or ounces.

Scale display shows "0.0 T".

  • There are two different weighing units in Weighing Only Mode: grams and ounces. A green dot will appear in the upper right of the LED display and the scale will read 0.000 when weighing in ounces.
  • The LED display shows [ 0.0 ] when the scale is measuring in grams.
  • The LED display shows [ 0.000 ] when the scale is measuring in ounces.
  • The readability is 0.1 g for grams and 0.005 oz for ounces.
ActionOperation
Tare WeightTap [Tare Button]
Switch between Grams / OuncesPress and hold [Tare Button]
Reset ModeDouble tap [Tare Button]
Switch ModePress and hold [Power Button]

Mode 2 - Dual Display Mode

In the Dual Display Mode, the scale displays [ 0:00 0.0 ] with a timer (left) and weight (right).

Scale display shows "0:00 0.0 T".

  • There are two different weighing units in Dual Display Mode: grams and ounces.
  • The LED display shows [ 0:00 0.0 ] when the scale is measuring in grams.
  • The LED display shows [ 0:00 0.000 ] when the scale is measuring in ounces.
  • When the weight exceeds 999 grams, the LED display only shows the integer part (the decimal point will not be displayed). The LED display shows up to a maximum of 3000 grams. If the weight exceeds 3000 grams, the scale will display [ Maximum ].
ActionOperation
Start / Stop / Reset TimerTap [Power Button]
Tare WeightTap [Tare Button]
Reset ModeDouble tap [Tare Button]
Switch between Grams / OuncesPress and hold [Tare Button]
Switch ModePress and hold [Power Button]

Mode 3 - Pour-Over Auto-Start Timer Mode

The Pour-Over Auto-Start Timer Mode is designed to aid pour-over coffee brewing. The scale will detect the start of the flow from kettle into the vessel and automatically start the timer function; the timer stops when the brewing equipment has been removed from the scale. When the vessel is removed from the scale, the display flashes the final beverage weight.

Display

  • The LED display flashes [ 0.0 ] and [ 0:00 0.0 ] when measuring in grams and the timer is idle.
  • The LED display flashes [ 0.000 ] and [ 0:00 0.000 ] when measuring in ounces and the timer is idle.
  • Once the timer has started, the LED display shows [ 0:00 0.0 ], with the time elapsed on the left and the weight on the right in grams.
  • Once the timer has started, the LED display shows [ 0:00 0.000 ], with the time elapsed on the left and the weight on the right in ounces.
  • When the weight exceeds 999 grams, the LED display only shows the integer part (the decimal point will not be displayed). The LED display shows up to a maximum of 3000 grams. If the weight exceeds 3000 grams, the scale will display [ Maximum ].

Mode Description

  • If the timer has not started yet, the display will flash 0:00 and a [water droplet] symbol.
  • The timer will start automatically when the first flow of water is detected.
  • The timer stops when the brewing equipment is removed. The scale will flash between the beverage weight and the tare weight of the items on the scale.
ActionOperation
Start / Stop / Reset TimerTap [Power Button]
Tare WeightTap [Tare Button]
Reset ModeDouble tap [Tare Button]
Switch between Grams / OuncesPress and hold [Tare Button]
Switch ModePress and hold [Power Button]

Mode 4 - Portafilter Mode

The Portafilter Mode is designed to speed up the workflow of accurately weighing coffee grounds in a portafilter. The scale automatically tares the portafilter and allows for the adjustment of the ground coffee. The mode will reset 15 seconds after removing the portafilter to enable weighing for the next shot.

Display

  • When measuring in grams, the display shows [ 0.0 ] before a portafilter is placed on the scale.
  • When measuring in ounces, the display shows [ 0.000 ] before a portafilter is placed on the scale.
  • The display shows [ 0.0 ] / [ 0.000 ] after a portafilter has been registered.

Mode Description

  • Place an empty portafilter on the scale, and the scale will register the weight of the portafilter.
  • Remove the portafilter after [■] disappears.
ActionOperation
Tare WeightTare function begins automatically when a stable weight is placed on the scale
Reset ModeDouble tap [Tare Button]
Switch between Grams / OuncesPress and hold [Tare Button]
Switch ModePress and hold [Power Button]

Note:

  1. If the scale is left idle for 15 seconds or you double tap the [Tare Button], the Pearl Model S will automatically reset the mode to default for the next auto-tare operation.
  2. To change the timer reset length in Portafilter Mode, see the “Configuration” section (p.14-15).

Mode 5 - Espresso Mode

This mode is designed to aid espresso extraction. The scale automatically tares the weight of the vessel. It will then detect the start of the flow of espresso into the vessel and automatically start the timer function; the timer stops when the flow of espresso into the vessel stops.

Display

  • The LED display flashes [ 0.0 ] and [ 0:00 0.0 ] when measuring in grams and the timer is idle.
  • The LED display flashes [ 0.000 ] and [ 0:00 0.000 ] when measuring in ounces and the timer is idle.
  • When the weight exceeds 999 grams, the LED display only shows the integer part (the decimal point will not be displayed). The LED display shows up to a maximum of 3000 grams. If the weight exceeds 3000 grams, the scale will display [ Maximum ].

Mode Description

  • When an object (such as a cup) weighing two grams or more is placed on the scale and the weight reading is stable, the scale will perform auto tare.
  • After the scale detects the flow of espresso, the timer will start. The timer will stop when the espresso flow stops.
  • When the espresso is ready and the cup is removed, the display will flash between the beverage weight and the vessel weight.
ActionOperation
Start / Stop / Reset TimerTap [Power Button]
Tare WeightTap [Tare Button]
Reset ModeDouble tap [Tare Button]
Switch between Grams / OuncesPress and hold [Tare Button]
Switch ModePress and hold [Power Button]

Note:

  1. In Espresso Mode, the timer will stop when the espresso flow stops.
  2. The auto-tare function is performed only when the weight exceeds two grams.
  3. If you leave the scale idle for ten seconds, it will reset the timer and perform tare operation.
  4. In Espresso Mode, the timer will also stop when a negative weight (i.e., removal of a cup) is detected.

Mode 6 - Flowrate Mode

Designed for pour-over coffee brewing. The display includes timer, weight, and flowrate.

Timer Weight Flowrate

  • The LED display shows [ 0:00 0.0 0.0 ] when the scale is measuring in grams.
  • The LED display shows [ 0:00 0.000 0.00 ] when the scale is measuring in ounces.
  • When the weight exceeds 999 grams, the LED display only shows the integer part (the decimal point will not be displayed). The LED display shows up to a maximum of 3000 grams. If the weight exceeds 3000 grams, the scale will display [ Maximum ].
  • The flowrate is measured in grams per second (g/s) on the right hand side of the display.
ActionOperation
Start / Stop / Reset TimerTap [Power Button]
Tare WeightTap [Tare Button]
Reset ModeDouble tap [Tare Button]
Switch between Grams / OuncesPress and hold [Tare Button]
Switch ModePress and hold [Power Button]

Mode 7 - Brewguide Mode

A step-by-step interactive guide to brewing coffee. Simply use the Acaia Brewguide app to download the recipe to your Pearl Model S. In the Brewguide app, you can also discover guides created by roasters around the world.

Note: Brewguide mode only supports display in grams.

ActionOperation
Go to the Next StepPress and hold [Tare Button]
Display Current Instruction Text AgainTap [Power Button]
TarePress [Tare Button]
Switch ModePress and hold [Power Button]

Mode 8 - Countdown Mode

The Countdown Mode is a customizable timer. Personalize your timer with 3 adjustable presets and over 30 melodious tones. Note that only one timer can be active at the same time.

You can further customize the countdown timer by enabling / disabling periodic reminders and choose if you would like the timer to continue counting with negative value after the time is up.

Mode Description

  • Press and hold [Tare Button] until the minutes start blinking to adjust the timer. Tap [Tare Button] to increase the current value. Press and hold [Tare Button] to scroll faster. Tap [Power Button] to confirm. Minimum time setting for the countdown timer is 00:10.
  • Tap [Power Button] to switch between the three timer presets.
  • Refer to the [Ringtone], [Continue Timer Countdown], and [Periodic] section in Advanced Settings Menu to further personalize your timer.
ActionOperation
Start / Stop / Reset TimerPress [Tare Button]
Timer AdjustmentPress and hold [Tare Button]
Switch PresetTap [Power Button]
Switch ModePress and hold [Power Button]

Configuration

Enter Settings

  1. With the scale powered off, press and hold the [Power Button]. When the LED display shows [acaia] and then changes to [Settings], release the [Power Button].
  2. Tap the [Tare Button] to enter Settings. The first setting is [Brightness].
  3. Please refer to the following table for key operations.
ActionOperation
Next SettingTap [Tare Button]
Previous SettingTap [Power Button]
Enter SettingPress and hold [Tare Button]
Toggle OptionsTap [Tare Button]
Save OptionPress and hold [Tare Button]
Back to Menu without SavingTap [Power Button]
Exit Settings and Return to ModesDouble tap [Power Button]

Settings Menu

The following table details the available settings:

SettingDisplayOptionsDefault
Brightness SettingBrightnessLow, Medium, High, BrightMedium
Timer Notification Sound SettingTimer Notification SoundSound, Voice, OffOff
Weight Notification Sound SettingWeight Notification SoundSound, Voice, OffOff
Volume SettingVolume1, 2, 3, 4, 5, Off3
Default Weighing Unit SettingUnitGrams, OuncesGrams
Weighing Only Mode SettingWeighing ModeOn, OffOn
Dual Display Mode SettingDual Display ModeOn, OffOn
Pour-Over Auto-Start Timer Mode SettingPour Over Auto Start Timer ModeOn, OffOff
Portafilter Mode SettingPortafilter ModeOn, OffOff
Espresso Mode SettingEspresso ModeOn, OffOff
Flowrate Mode SettingFlowrate ModeOn, OffOff
Brewguide Mode SettingBrewguide ModeOn, OffOn
Countdown Mode SettingCountdown ModeOn, OffOff
Ringtone SettingRingtoneGlow, Kalimba, Goldberg, Bells, and more.Glow
Hello Message SettingHello MessageOn, OffOff
Weight Stable Indicator SettingWeight Stable IndicatorOn, OffOff
Bluetooth SettingBluetooth SettingOn, OffOn
Sleep Timer SettingSleep Timer5 Min, 10 Min, 20 Min, 30 Min, 60 Min, Off10 Min
Battery Saving SettingBattery Saving30 Sec, 90 Sec, 180 Sec, Off90 Sec
Weighing Filter SettingFilterNormal, High, SensitiveNormal
Zero Tracking SettingZero Tracking0.5D, 1D, 2D, 3D, Off1D
Weighing Resolution SettingResolutionDefault, Low, HighDefault
Timer Auto Stop on Cup Removal SettingTimer Auto Stop on Cup Removal10 Sec, 30 Sec, 60 Sec, Off10 Sec
Timer Auto Reset SettingTimer Auto Reset20 sec, 60 sec, Off20 sec
Portafilter Auto Reset SettingPortafilter Auto Reset15 Sec, 30 Sec, 60 Sec15 Sec
Continue Timer Countdown SettingContinue Timer CountdownOn, OffOn
Periodic SettingPeriodic30 sec, 60 sec, Off30 sec
Reset to DefaultReset to DefaultNo, YesNo

Brightness Setting [Brightness]

By default, the Brightness is set to Medium. You can adjust the brightness of the LED display. Set to Bright when operating under strong light.

Timer Notification Sound Setting [Timer Notification Sound]

By default, the Timer Notification Sound is set to Off. Supported in Dual Display Mode, Espresso Mode, Pour-Over Auto-Start Timer Mode, and Flowrate Mode.

  • Voice: The scale will read out the time every 10 seconds once the timer is started.
  • Sound: The Pearl Model S will notify timer event of every 10 seconds and 60 seconds once the timer is started.
  • Off: Timer Notification Sound is disabled.

Weight Notification Sound Setting [Weight Notification Sound]

By default, the Weight Notification Sound is set to Off. Supported in Weighing Only Mode, Dual Display Mode, Espresso Mode, Pour-Over Auto-Start Timer Mode, and Flowrate Mode.

  • Voice: The scale reads out the weight value when stable weight is detected, and every 20 grams of weight increment during a brewing session.
  • Sound: The scale will notify 20 grams of weight increment with sound effect.
  • Off: Weight Notification Sound is disabled.

Volume Setting [Volume]

By default, the Volume is set to 3. Adjust the volume of the Pearl Model S ranging from 1-5 or select “Off” to mute.

Default Weighing Unit Setting [Unit]

By default, the Weighing Unit is set to Grams. Press and hold [Tare Button] to switch the weighing unit between grams and ounces.

Weighing Only Mode Setting [Weighing Mode]

By default, the Weighing Only Mode is set to On.

  • On: The Weighing Only Mode is enabled.
  • Off: The Weighing Only Mode is disabled.

Dual Display Mode Setting [Dual Display Mode]

By default, the Dual Display Mode is set to On.

  • On: The Dual Display Mode is enabled.
  • Off: The Dual Display Mode is disabled.

Pour-Over Auto-Start Timer Mode Setting [Pour Over Auto Start Timer Mode]

By default, the Pour-Over Auto-Start Timer Mode is set to Off.

  • On: The Pour-Over Auto-Start Timer Mode is enabled.
  • Off: The Pour-Over Auto-Start Timer Mode is disabled.

Portafilter Mode Setting [Portafilter Mode]

By default, the Portafilter Mode is set to Off.

  • On: The Portafilter Mode is enabled.
  • Off: The Portafilter Mode is disabled.

Espresso Mode Setting [Espresso Mode]

By default, the Espresso Mode is set to Off.

  • On: The Espresso Mode is enabled.
  • Off: The Espresso Mode is disabled.

Flowrate Mode Setting [Flowrate Mode]

By default, the Flowrate Mode is set to Off.

  • On: The Flowrate Mode is enabled.
  • Off: The Flowrate Mode is disabled.

Brewguide Mode Setting [Brewguide Mode]

By default, the Brewguide Mode is set to On.

  • On: The Brewguide Mode is enabled.
  • Off: The Brewguide Mode is disabled.

Countdown Mode Setting [Countdown Mode]

By default, the Countdown Mode is set to Off.

  • On: The Countdown Mode is enabled.
  • Off: The Countdown Mode is disabled.

Ringtone Setting [Ringtone]

By default, the Ringtone is set to Glow. The ringtone selected will be played in Countdown Mode when the time is up.

Hello Message Setting [Hello Message]

By default, the Hello Message is set to Off.

  • On: The Hello Message will show when the scale is turned on.
  • Off: The Hello Message will not show when the scale is turned on.

Weight Stable Indicator Setting [Weight Stable Indicator]

By default, the Weight Stable Indicator is set to Off.

  • On: Weight Stable Indicator enabled. The Weight Stable Indicator on the bottom right of the display lights up when the weight is stable.
  • Off: Weight Stable Indicator is disabled.

Bluetooth Setting [Bluetooth Setting]

By default, Bluetooth is set to On.

  • On: Bluetooth is enabled, allowing the scale to connect to Acaia apps.
  • Off: Bluetooth is disabled. The scale does not allow any Bluetooth connection.

Sleep Timer Setting [Sleep Timer]

By default, the Sleep Timer is set to 10 minutes. The scale will automatically power off after 10 minutes if not in use.

Battery Saving Setting [Battery Saving]

By default, the Battery Saving is set to 90 seconds. The LED display will dim to save power after the selected number of seconds when not in use.

Weighing Filter Setting [Filter]

By default, the Filter is set to Normal. The weighing filter setting determines the speed with which the load receptor responds to and determines the weight. [ High ] indicates a more stable but slower weighing result; [ Sensitive ] indicates higher sensitivity and a faster weighing result.

Zero Tracking Setting [Zero Tracking]

By default, the Zero Tracking is set to 1D. Zero Tracking is a function to help compensate the weight readout fluctuations at zero point to improve the usability of the scale. Acaia Pearl Model S is allowed to compensate the fluctuation by up to 2D according to industrial weighing guidelines.

  • Off: It is not recommended to turn off zero tracking as the zero indication can drift easily with changing room temperatures.
  • 0.5D~3D: For example, since each division is 0.1 g, 3D = 0.3 g. When zero tracking is set to be 3D, any initial weight between +/- 0.3 g on the weighing pan will be zeroed out.
  • 1D is recommended for Acaia Pearl Model S.

Weighing Resolution Setting [Resolution]

The default Weighing Resolution is set to [ Default ], the division is 0.1 g for weights under 1500 grams and 0.5 g for weights between 1500 and 3000 grams.

  • When the weighing resolution is set to [ High ], the division will be 0.1 g throughout the entire time from 0 to 3000 grams.
  • When the weighing resolution is set to [ Low ], the division will be 1 g throughout the entire time from 0 to 3000 grams.

Timer Auto Stop on Cup Removal Setting [Timer Auto Stop on Cup Removal]

By default, the Timer Auto Stop on Cup Removal is set to 10 seconds. This setting is for Dual Display Mode only and will not override the timer for auto-start mode.

  • When a cup is removed from the scale, the timer will automatically stop after selected number of seconds.
  • The default setting is 10 seconds, meaning in Dual Display Mode, the timer will stop automatically when the container or brewing equipment has been removed for 10 seconds.

Timer Auto Reset Setting [Timer Auto Reset]

By default, the Timer Auto Reset is set to 20 seconds. In Pour Over Auto Start Mode, after the container or brewing equipment is removed, the timer and weight will reset after selected number of seconds.

  • Off: The timer will not reset automatically until being reset manually (double tap [Tare Button] to reset).

Portafilter Auto Reset Setting [Portafilter Auto Reset]

By default, the Portafilter Auto Reset is set to 15 seconds. In Portafilter Mode, after a portafilter is removed, the weight will automatically reset. This setting gives you options on how long to wait before resetting.

Continue Timer Countdown Setting [Continue Timer Countdown]

By default, the Continue Timer Countdown is set to On. The timer will continue counting in negative value after time is up.

  • Off: Disable Continue Timer Countdown.

Periodic Setting [Periodic]

By default, the Periodic is set to 30 seconds. The Pearl Model S notifies with sound effect every 30 seconds in Countdown Mode when the countdown timer is running.

  • 60 sec: Notify with sound effect every 60 seconds.
  • Off: Periodic reminder is disabled.

Reset to Default [Reset to Default]

By default, the Reset to Default is set to No. To reset the scale to its factory default settings, go to [Reset to Default], then choose [Yes]. The scale will clear the Hello Message and reset all settings including Brewguide data to factory default.

Appendix

Buttons

Diagram shows a scale with labels pointing to the Power Button and Tare Button.

ButtonFunctionExample
Power ButtonTurn onTap to turn on the scale.
Turn offDouble tap to turn off the scale.
Switch ModeWhile the scale is turned on, press and hold for one second to switch modes.
Advanced SettingsWhen the scale is turned off, press and hold to enter Settings.
Start / Stop / Reset TimerTap to start / stop / reset timer.
BackWhile in Settings Menu, double tap to go back to Modes.
Tare ButtonTareTap to perform tare operation.
Switch between Grams / OuncesPress and hold to switch weighing unit between grams and ounces.
Switch optionsWhile in Settings, tap to advance through settings options. While in settings, tap to switch options in sub menus.
ResetDouble tap to reset a mode. This zeroes the weight and sets the timer to 0:00.
ConfirmWhile in Settings, press and hold for two seconds to confirm the option selected in a sub menu.
Enter Calibration ModeWhile in Weighing Mode, set the unit to grams and rapidly tap to enter Calibration Mode.

LED Indicators

Diagram shows a scale with labels pointing to the locations of LED indicators: Battery Charge / Low Battery Indicator, Bluetooth Connection Indicator / Button Pressed, Weighing in Ounces, and Weight Stable Indicator.

Battery Charge / Low Battery Indicator

This indicator turns on when the battery is charging and turns off once the battery is fully charged. The indicator starts flashing when the battery power is low as a reminder to charge the scale.

* Note: The Acaia Pearl Model S is equipped with charging protection to prevent the battery from charging under high temperatures. It is normal if the scale does not charge when the surface is hot from brewing coffee. Battery charging function will be enabled once the scale has cooled.

Bluetooth Connection Indicator / Button Pressed

The orange indicator on the lower left turns on when the [Tare Button] is pressed.

Weighing in Ounces

The green indicator on the upper right turns on when the weight is measured in ounces.

Weight Stable Indicator

If Weight Stable Indicator setting is on, the green indicator on the lower right turns on when the weight is stable.

Error Codes

Error CodeDescription
Error 100Access Code Error, unrecognized access code.
Error 101EEPROM error, unable to access memory. Please contact Acaia support.
Error 102AD error, unable to access weighing signal. Please contact Acaia support.
Error 303Unable to find acceptable starting Zero point, most likely because the loadcell has been damaged by excessive force or drop. Please contact Acaia support.
MaximumOverload: the weight is over the maximum capacity.
UnderloadUnderload: the weight is under the minimum capacity.
Error 304Calibration error. Calibration cannot proceed when environmental noises are too strong. Please calibrate in a stable environment free of wind, vibration, etc.
Error 802Unable to tare because the weight exceeds the acceptable tare range.
Error 803Unable to tare because the weight is unstable.

Other

Display CodeDescription
UPDATEThe scale is in update mode. During the update process, the green LED on the lower right will blink until the process is complete.

Note: If you want to leave update mode, please connect the scale's USB to a power source.

Specifications

ModelPS003 / PS004
Product Weight620 g ± 5 g
Product DimensionsW: 160 mm L: 160 mm H: 32 mm
Maximum Capacity3000 g / 105.82 oz
Minimum Weight0.1 g
Measuring UnitsGrams, Ounces
Readability0.1 g
Repeatability0.1 g
Linearity1 d (d = 0.1 g / 0.5 g)
Indication Limit3090 g / 108.99 oz
Power Supply5 V / 500 mA
BatteryLithium-ion rechargeable 3.7 V 2200 mAh
Battery LifeUp to 16~40 hours
DisplayDot matrix LED
MaterialPC
ConnectivityBluetooth 5.0
Warranty1 Year
Inside the PackageAcaia Pearl Model S Coffee Scale (White / Black) x 1
Heat Resistant Coaster (Round) x 1
USB Type-C Charger Cable x 1

Copyright

This user manual is protected by copyright. All rights reserved. No part of this manual may be reproduced, processed, duplicated or published in any form by photocopying, microfilming, reprinting or any other method, in particular electronic means, without the written consent of Acaia.

© Acaia, California, 2023.

Models: PS003 Pearl Model S Coffee Scale, PS003, Pearl Model S Coffee Scale, Model S Coffee Scale, S Coffee Scale, Coffee Scale

File Info : application/pdf, 24 Pages, 1.47MB

PDF preview unavailable. Download the PDF instead.

PearlS MAN AE10F05001 EN Adobe PDF Library 17.0 Adobe InDesign 18.1 (Macintosh)

Related Documents

Preview Acaia Pearl Model S Smart Coffee Scale User Manual
Comprehensive user manual for the Acaia Pearl Model S smart coffee scale, covering setup, features, modes, settings, and maintenance.
Preview Acaia Pearl Model S User Manual: Features, Operation, and Specifications
Comprehensive user manual for the Acaia Pearl Model S coffee scale, covering setup, modes, features, care, configuration, troubleshooting, and specifications. Learn how to use its advanced functions for precise coffee brewing.
Preview Acaia Pyxis User Manual - Setup, Features, and Specifications
Comprehensive user manual for the Acaia Pyxis weighing scale, covering setup, operation modes, configuration, troubleshooting, and technical specifications. Learn how to use your Acaia Pyxis for precise weighing.
Preview Acaia Umbra Lunar Duo User Manual
Comprehensive user manual for the Acaia Umbra Lunar Duo scale, detailing setup, operation modes, app connectivity, product care, troubleshooting, and specifications.
Preview Acaia Pearl Operation Manual: Precision Coffee Scale Guide
Comprehensive operation manual for the Acaia Pearl precision coffee scale (FW 2.0.008). Learn about setup, basic operations, various modes, calibration, configuration settings, and troubleshooting.
Preview Acaia Umbra Lunar Quick Start Guide: Setup, Features, and Operation
This Quick Start Guide provides essential information for setting up and using the Acaia Umbra Lunar, a precision weighing scale for espresso workflows. It covers product overview, package contents, modes of operation, connectivity with Acaia devices and the Brewmaster App, battery charging, calibration, warranty, and support.
Preview Acaia Umbra Lunar Quick Start Guide: Precision Espresso Weighing
Learn how to set up, operate, and connect your Acaia Umbra Lunar, a high-precision, display-free scale designed for the modern espresso workflow. Features include Magic Relay, app integration, and multiple weighing modes.
Preview Acaia Lunar Espresso Scale: Quick Start Guide
Learn how to set up, use, and calibrate your Acaia Lunar espresso scale. This guide covers package contents, features, modes, and care for precise coffee brewing.