Acaia Pearl Operation Manual

Using Your Pearl

FW 2.0.008

Identification

The instructions in this operation manual apply to the Acaia Coffee Scale. You have purchased a quality precision weighing scale that requires handling with care. Make sure to read through this operation manual prior to using the scale.

Disclaimer Notice

Calibrate your scale using calibration weight of the appropriate tolerance (class). A scale can be no more accurate than standard masses to which it has been compared. For more details, please read the Calibration Mode section in the operation manual.

CAUTION:

  1. Do not place any hot object directly on the weighing pan. Please use a heat resistant pad under hot objects.
  2. Any modification made without the consent of the manufacturer may result in damage to the scale.

Chapter 1: Scale at a Glance

Introduction

Thank you for choosing one of our scales. The Acaia Coffee Scale is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience. First of all, check the shipping carton to find the followings:

Next, follow the instructions in Preparation and Installation sections in the manual to get started. To take an advantage of its many features, carefully read through the operation manual containing step-by-step procedures, examples, and other information.

Warning: Incorrect handling of this product could possibly result in personal injury or physical damage.

Specifications

Aprox. weight462g
Capacity2000g / 70.54oz
Measuring Unitsg, oz
Weighing range 1Maximum capacity1000.0g35.280oz
Minimum capacity1.0g0.035oz
Division0.1g0.005oz
Weighing range 2Maximum capacity2000.0g70.540oz
Minimum capacity1000.0g35.280oz
Division0.5g0.020oz
Indication limit2060.0g / 72.660oz
Unit dimensions(L x W x H) 160x160x30mm
Electrical Requirements5V/500mA
Power and BatteryLithium-ion rechargeable 3.7V 1100mA
DisplayLEDTop: PC, Touch sensitive
Bottomanti-slip, rubber, flat surface.
ConnectivityBluetooth 4.0
Linearity+/- 0.2g
Work timeUp to 25 hours

Scale Overview

Scale Front: The scale features a Weighing Pan, a Power Button (⏻), an LED Display, and a Tare Button (T).

Scale Back: The back of the scale has a Micro-B USB port.

Note: For the best performance, place the weight in the center of the weighing platform.

Accessories

Micro-B USB Cable: A cable with a Micro-B connector on one end and a Type-A USB connector on the other.

Heat Resistant Pad: A pad designed to protect the scale from hot objects.

Buttons

ButtonFunctionExample
Power (⏻)Turn onLong Press to turn on the scale.
Power (⏻)Turn offDouble-tap the power button to turn off the scale.
Power (⏻)Switch mode (Default)While the scale is turned on, press and hold for 2 seconds to switch mode.
Power (⏻)Start/Stop/Reset TimerWhile in Timer Mode, press to start/stop/reset timer.
Tare (T)BackWhile in Settings, press to go back to Weighing Mode from menu tree.
Tare (T)TareWhile in Weighing Mode, press to make tare operation.
Tare (T)Toggle UnitsLong Press to change between Gram and Ounce in Weighing Mode.
Tare (T)Switch optionWhile in Settings, press to switch options.
Tare (T)Reset ModeDouble Tap to reset mode.
Tare (T)ConfirmWhile in Settings, press and hold for 2 seconds to confirm the option selected.
Tare (T)Enter calibration modesWhile in Weighing Mode, continuously press multiple times to enter Calibration Mode.

Please find Chapter 3: Basics for more details.

LED Indicators

Battery Charge / Charge Error: The LED indicator on the upper left lights orange when charging and turns off when fully charged. It flashes if the USB cable is not working.

Timer Reset: The LED indicator on the lower left lights orange when the timer resets.

Tare Operation: The tare indicator on the lower right lights green when the Tare button (T) is pressed.

Ounce Indication: The ounce indicator on the upper right lights green when the weighing unit is in ounce.

Battery Charge

You can charge the battery by plugging the USB cable into any power supply, such as:

It takes about 1-2 hours to fully charge the battery from empty. A fully charged battery can continuously last for about 25 hours. Battery percentage can be viewed via the Acaia App.

Chapter 2: Getting Started

Preparation

Installation

Chapter 3: Basics

Basic Operations

ActionOperation
Turn On ScaleLong Press ⏻
Turn Off ScaleDouble Tap ⏻
Switch ModeLong Press ⏻
Tare WeightShort Press T
Reset ModeDouble Tap T

Modes

To Enable/Disable Modes, please go to Chapter 5: Configuration on Page 16.

Mode 0 - Weighing Mode

This mode displays weight. The LED display shows [ 0.0 ] when the weighing unit is in gram.

ActionOperation
Tare WeightShort Press T
Toggle Units G/OzLong Press T
Reset ModeDouble Tap T
Switch ModeLong Press ⏻

Mode 1 - Espresso Mode

The LED Timer is on the left, weighing result on the right.

ActionOperation
Start/Pause/Reset TimerShort Press ⏻
Tare WeightShort Press T
Reset ModeDouble Tap T
Switch ModeLong Press ⏻

To Enable/Disable Espresso Mode, please go to Chapter 5: Configuration on Page 16.

Mode 2 - Timer Mode

ActionOperation
Start/Stop/Reset TimerShort Press ⏻
Tare WeightShort Press T
Reset ModeDouble Tap T
Switch ModeLong Press ⏻

To Enable/Disable Timer Mode, please go to Chapter 5: Configuration on Page 16.

Mode 3 - Auto Start Mode

Place materials on the scale. Tap the Power button (⏻) to automatically tare. Begin pouring, and the timer will start with the pour. The timer stops when brewing equipment is removed.

ActionOperation
Initiate Auto StartShort Press ⏻
TareShort Press T
Stop TimerWhile timer is running, Short Press ⏻
Reset ModeDouble Tap T
Switch ModeLong Press ⏻

To Enable/Disable Auto Start Mode, please go to Chapter 5: Configuration on Page 16.

Mode 4 - Beverage Mode

Follow instructions on the display to place the carafe, filter, and coffee (tap Tare in between steps). The timer will start with the pour. Lift dripper and filter off to stop the timer. The flashing number is your beverage weight with all items subtracted.

ActionOperation
Next StepShort Press T
Previous StepShort Press ⏻
Stop TimerShort Press ⏻
Reset ModeDouble Tap T
Switch ModeLong Press ⏻

Display Meanings:

DisplayAction/Description
CUPPut the carafe/cup on the scale.
FLtPut the filter on the cup.
COFPut the coffee in the filter.
Timer FlashesReady to Brew
-FLt-Please remove filter.
bxxxx,xBeverage Weight
xxx.xTotal Weight

To Enable/Disable Beverage Mode, please go to Chapter 5: Configuration on Page 16.

Mode 5 - Auto Tare Mode (after version 2.0.008)

Displays weight only. Place item on and off the scale, and it will automatically tare.

ActionOperation
Tare WeightShort Press T
Reset ModeDouble Tap T
Switch ModeLong Press ⏻

To Enable/Disable Auto Tare Mode, please go to Chapter 5: Configuration on Page 16.

Chapter 4: Calibration

Calibration Mode

  1. While the scale is in Weighing Mode and the weighing unit is in gram, press the Tare button (T) quickly multiple times until the LED display shows [CAL] and then [500].
  2. Place a 500g calibration weight on the scale and wait for the scale to execute the calibration procedure.
  3. The LED display shows [-End-] when the calibration procedure is completed. You may unload the calibration weight when completed.

Note: Calibration weight of 100g, 1000g, 1500g, or 2000g can also be used.

Chapter 5: Configuration

Enter Settings

  1. Press and hold the Power button (⏻) while turning ON the scale.
  2. Keep the Power button (⏻) pressed. When the LED display shows [ACAI A] and turns [SEt], Long Press the Tare button (T) for another 2 seconds without releasing the button.
  3. Release both Power (⏻) and Tare (T) buttons when the display shows [F.0000].
  4. Long Press the Tare button (T) to move the flashing digit to the right. Repeat this step 4 times to enter Settings. It will show the first setting [SLEEP].

Settings

SettingDisplayOptionsDefault
Auto Switch OffSLEEP5, 10, 20, 30, 60, Off5
Auto ZeroO.AUtoOn, OffOff
Zero TrackingtrAcE2d, 3d, Off2d
Key SoundbEEPOn, OffOn
Zero RangeO.ranGE2, 100100
Weighing FilterFi lt2, 4, 6, 8, 16, 32, 64, 12816
Default Weighing unitUnitGram, OunceGram
Weighing ResolutionrESoLDefault, HighDefault
Espresso ModeNodE_1On, OffOff
Timer ModeNodE_2On, OffOn
Auto Start ModeNode_3On, OffOff
Beverage ModeNodE_4On, OffOff
Auto Tare ModeNodE_5On, OffOn
Bluetooth PasswordrESEt.dYes, NoNo
Bluetooth On/Offbt_SEtOn, OffOn

Settings Operations:

ActionOperation
Next SettingShort Press T
Enter SettingLong Press T
Toggle OptionsShort Press T
Save OptionLong Press T
Leave SettingShort Press ⏻

Detailed Settings Explanations

Auto Sleep Settings

Auto Sleep Settings can also be configured in the Acaia App. The number indicates the amount of time before the scale enters sleeping mode. For example, when 10 is selected, the scale enters sleeping mode after 10 minutes of idling.

Auto Zero Settings
  1. When Auto Zero setting is off or disabled, the initial weight on the weighing pan must be less than 50% of capacity (i.e., less than 1kg for Acaia coffee scale) before the scale is turned on. Otherwise, an error [Er.303] occurs. When the error occurs, the scale would not work until the initial weight on the weighing pan is cleared.
  2. When Auto Zero setting is on or enabled, the scale displays the initial weight directly regardless of whether the weight is over 50% of capacity.
Zero Tracking

Zero Tracking is a function for maintaining the zero indication within certain limits automatically.

Key Sound Settings

Key Sound Settings can also be configured in the Acaia App. Set the Key Sound function off to turn off the beeping sound or on to turn on the beeping sound.

Zero Range Setting

Zero Range setting determines the range for which the Tare button (T) executes zero operation instead of tare operation.

  1. When Zero Range is set to 2, the range for zero-setting will be 2% of the capacity, i.e., +/- 40g for Acaia coffee scale. By pressing the Tare button (T), any weight within +/- 40g is zeroed out by zero operation, while any weight outside the range is tared out by tare operation.
  2. If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., +/- 2kg for Acaia coffee scale. Therefore, instead of tare operation, zero operation would be executed in this setting whenever the Tare button (T) is pressed.

Notice: The difference between zero operation and tare operation is that zero operation would simply ignore the weight and display as 0, while tare operation would deduct the weight from the weighing result. However, zero operation does not increase the scale capacity.

Weighing filter setting

The number shown on the LCD display indicates the current filter parameter which determines the speed for the load receptor to respond to weight and to determine the weighing value. The larger the number, the more stable but slower the weighing result will be.

Default Weighing Unit

The Default Weighing Unit is set to be gram.

Weighing resolution
  1. The default Weighing Resolution is set to [Default]: the division is 0.1g under weight of 1000g and 0.5g from 1000g to 2000g.
  2. When the Weighing Resolution is set to High, the division will be 0.1g throughout the entire time from 0g to 2000g.
Bluetooth Password
Bluetooth On/Off

Appendix

Error Code

Error CodeDescription
100Code error
101EEPROM error
102AD read error
Over load: the weight is over the maximum capacity.
Under load: the weight is under the minimum capacity.
303Unable to make zero point, for the initial weight exceeds the limit (50% of capacity).
304Please do calibrate in a stable environment without wind or shake etc.
802Unable to tare, for the weight exceeds the tare range.
803Unable to tare, for the weight is unstable.
900Password error (the default password is 0000)

Copyright

The operation manual is protected by copyright. All rights reserved. No part of the operation manual may be reproduced, processed, duplicated or published in any form by photocopying, microfilming, reprinting or any other method, in particular electronic means, without the written agreement of Acaia.

© Acaia, Cupertino, CA, 2017.

PDF preview unavailable. Download the PDF instead.

BE00-061-0000 manuale ACAIA-pearl Mac OS X 10.12.5 Quartz PDFContext Pages

Related Documents

Preview Acaia Lunar Espresso Scale: Quick Start Guide
Learn how to set up, use, and calibrate your Acaia Lunar espresso scale. This guide covers package contents, features, modes, and care for precise coffee brewing.
Preview Acaia Pearl Model S User Manual - Setup, Features, and Operation Guide
Detailed user manual for the Acaia Pearl Model S coffee scale, covering its features, various brewing modes, settings configuration, troubleshooting, and specifications. Learn how to use your Acaia scale for precise coffee brewing.
Preview Acaia Pearl Model S User Manual: Features, Operation, and Specifications
Comprehensive user manual for the Acaia Pearl Model S coffee scale, covering setup, modes, features, care, configuration, troubleshooting, and specifications. Learn how to use its advanced functions for precise coffee brewing.
Preview Acaia Umbra Lunar Duo User Manual
Comprehensive user manual for the Acaia Umbra Lunar Duo scale, detailing setup, operation modes, app connectivity, product care, troubleshooting, and specifications.
Preview Acaia Pearl Model S Smart Coffee Scale User Manual
Comprehensive user manual for the Acaia Pearl Model S smart coffee scale, covering setup, features, modes, settings, and maintenance.
Preview Acaia Pyxis User Manual - Setup, Features, and Specifications
Comprehensive user manual for the Acaia Pyxis weighing scale, covering setup, operation modes, configuration, troubleshooting, and technical specifications. Learn how to use your Acaia Pyxis for precise weighing.
Preview Acaia Brew-by-Weight Scale for La Marzocco - User Manual
Comprehensive user manual for the Acaia Brew-by-Weight Scale designed for La Marzocco, detailing setup, operation modes, features like flow rate display, tare functions, and configuration settings.
Preview Acaia Umbra Lunar Quick Start Guide: Precision Espresso Weighing
Learn how to set up, operate, and connect your Acaia Umbra Lunar, a high-precision, display-free scale designed for the modern espresso workflow. Features include Magic Relay, app integration, and multiple weighing modes.