Acaia Pearl Operation Manual
Using Your Pearl
FW 2.0.008
Identification
The instructions in this operation manual apply to the Acaia Coffee Scale. You have purchased a quality precision weighing scale that requires handling with care. Make sure to read through this operation manual prior to using the scale.
Disclaimer Notice
Calibrate your scale using calibration weight of the appropriate tolerance (class). A scale can be no more accurate than standard masses to which it has been compared. For more details, please read the Calibration Mode section in the operation manual.
CAUTION:
- Do not place any hot object directly on the weighing pan. Please use a heat resistant pad under hot objects.
- Any modification made without the consent of the manufacturer may result in damage to the scale.
Chapter 1: Scale at a Glance
Introduction
Thank you for choosing one of our scales. The Acaia Coffee Scale is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience. First of all, check the shipping carton to find the followings:
- Acaia Coffee Scale
- Heat Resistant Pad
- Micro-B USB cable
Next, follow the instructions in Preparation and Installation sections in the manual to get started. To take an advantage of its many features, carefully read through the operation manual containing step-by-step procedures, examples, and other information.
Warning: Incorrect handling of this product could possibly result in personal injury or physical damage.
Specifications
Aprox. weight | 462g | ||
Capacity | 2000g / 70.54oz | ||
Measuring Units | g, oz | ||
Weighing range 1 | Maximum capacity | 1000.0g | 35.280oz |
Minimum capacity | 1.0g | 0.035oz | |
Division | 0.1g | 0.005oz | |
Weighing range 2 | Maximum capacity | 2000.0g | 70.540oz |
Minimum capacity | 1000.0g | 35.280oz | |
Division | 0.5g | 0.020oz | |
Indication limit | 2060.0g / 72.660oz | ||
Unit dimensions | (L x W x H) 160x160x30mm | ||
Electrical Requirements | 5V/500mA | ||
Power and Battery | Lithium-ion rechargeable 3.7V 1100mA | ||
Display | LEDTop: PC, Touch sensitive | ||
Bottom | anti-slip, rubber, flat surface. | ||
Connectivity | Bluetooth 4.0 | ||
Linearity | +/- 0.2g | ||
Work time | Up to 25 hours |
Scale Overview
Scale Front: The scale features a Weighing Pan, a Power Button (⏻), an LED Display, and a Tare Button (T).
Scale Back: The back of the scale has a Micro-B USB port.
Note: For the best performance, place the weight in the center of the weighing platform.
Accessories
Micro-B USB Cable: A cable with a Micro-B connector on one end and a Type-A USB connector on the other.
Heat Resistant Pad: A pad designed to protect the scale from hot objects.
Buttons
Button | Function | Example |
---|---|---|
Power (⏻) | Turn on | Long Press to turn on the scale. |
Power (⏻) | Turn off | Double-tap the power button to turn off the scale. |
Power (⏻) | Switch mode (Default) | While the scale is turned on, press and hold for 2 seconds to switch mode. |
Power (⏻) | Start/Stop/Reset Timer | While in Timer Mode, press to start/stop/reset timer. |
Tare (T) | Back | While in Settings, press to go back to Weighing Mode from menu tree. |
Tare (T) | Tare | While in Weighing Mode, press to make tare operation. |
Tare (T) | Toggle Units | Long Press to change between Gram and Ounce in Weighing Mode. |
Tare (T) | Switch option | While in Settings, press to switch options. |
Tare (T) | Reset Mode | Double Tap to reset mode. |
Tare (T) | Confirm | While in Settings, press and hold for 2 seconds to confirm the option selected. |
Tare (T) | Enter calibration modes | While in Weighing Mode, continuously press multiple times to enter Calibration Mode. |
Please find Chapter 3: Basics for more details.
LED Indicators
Battery Charge / Charge Error: The LED indicator on the upper left lights orange when charging and turns off when fully charged. It flashes if the USB cable is not working.
Timer Reset: The LED indicator on the lower left lights orange when the timer resets.
Tare Operation: The tare indicator on the lower right lights green when the Tare button (T) is pressed.
Ounce Indication: The ounce indicator on the upper right lights green when the weighing unit is in ounce.
Battery Charge
You can charge the battery by plugging the USB cable into any power supply, such as:
- A computer
- A wall A/C via USB power adapter
- A DC via car power adapter
It takes about 1-2 hours to fully charge the battery from empty. A fully charged battery can continuously last for about 25 hours. Battery percentage can be viewed via the Acaia App.
Chapter 2: Getting Started
Preparation
- This scale is intended for indoor use.
- Select a work place that is stable, vibration-free, and, if possible, a horizontal location for the weighing platform.
- Do not locate the scale near any equipment/instrument which contains magnets.
- Avoid places where room temperatures are unstable. Room temperature above 40°C or below 15°C may result in weighing inaccuracy.
Installation
- To use an AC adapter instead of the built-in battery, plug the USB cable into the Micro-B USB port located on the back panel of the scale.
- Long press the Power button (⏻) to turn on the scale.
- It is highly recommended to calibrate the scale with calibration weight before using.
- Please make sure to use a heat resistant pad under hot objects.
Chapter 3: Basics
Basic Operations
Action | Operation |
---|---|
Turn On Scale | Long Press ⏻ |
Turn Off Scale | Double Tap ⏻ |
Switch Mode | Long Press ⏻ |
Tare Weight | Short Press T |
Reset Mode | Double Tap T |
Modes
To Enable/Disable Modes, please go to Chapter 5: Configuration on Page 16.
- Mode 0 - Weighing Mode
- Mode 1 - Espresso Mode
- Mode 2 - Timer Mode
- Mode 3 - Auto Start Mode
- Mode 4 - Beverage Mode
- Mode 5 - Auto Tare Mode
Mode 0 - Weighing Mode
This mode displays weight. The LED display shows [ 0.0 ] when the weighing unit is in gram.
Action | Operation |
---|---|
Tare Weight | Short Press T |
Toggle Units G/Oz | Long Press T |
Reset Mode | Double Tap T |
Switch Mode | Long Press ⏻ |
- There are two different weighing units in Weighing Mode: grams and ounces.
- The readability is 0.1g for grams and 0.005oz for ounces.
Mode 1 - Espresso Mode
The LED Timer is on the left, weighing result on the right.
Action | Operation |
---|---|
Start/Pause/Reset Timer | Short Press ⏻ |
Tare Weight | Short Press T |
Reset Mode | Double Tap T |
Switch Mode | Long Press ⏻ |
- The timer displays from 0 to 59 seconds in cycle and will reset when reaching 60 seconds. When it resets, the Mode Indicator flashes.
- The readability decreases when the weight is over 99.9. The LED display shows up to a maximum of [1999].
To Enable/Disable Espresso Mode, please go to Chapter 5: Configuration on Page 16.
Mode 2 - Timer Mode
Action | Operation |
---|---|
Start/Stop/Reset Timer | Short Press ⏻ |
Tare Weight | Short Press T |
Reset Mode | Double Tap T |
Switch Mode | Long Press ⏻ |
- The maximum time is 9 minutes and 59 seconds. The Weight display of the right side is from 0 to 999. When the value is over 1000, it will restart from 0 with Mode Indicator flashing.
- Mode indicator flashes to indicate 1000.
To Enable/Disable Timer Mode, please go to Chapter 5: Configuration on Page 16.
Mode 3 - Auto Start Mode
Place materials on the scale. Tap the Power button (⏻) to automatically tare. Begin pouring, and the timer will start with the pour. The timer stops when brewing equipment is removed.
Action | Operation |
---|---|
Initiate Auto Start | Short Press ⏻ |
Tare | Short Press T |
Stop Timer | While timer is running, Short Press ⏻ |
Reset Mode | Double Tap T |
Switch Mode | Long Press ⏻ |
To Enable/Disable Auto Start Mode, please go to Chapter 5: Configuration on Page 16.
Mode 4 - Beverage Mode
Follow instructions on the display to place the carafe, filter, and coffee (tap Tare in between steps). The timer will start with the pour. Lift dripper and filter off to stop the timer. The flashing number is your beverage weight with all items subtracted.
Action | Operation |
---|---|
Next Step | Short Press T |
Previous Step | Short Press ⏻ |
Stop Timer | Short Press ⏻ |
Reset Mode | Double Tap T |
Switch Mode | Long Press ⏻ |
Display Meanings:
Display | Action/Description |
---|---|
CUP | Put the carafe/cup on the scale. |
FLt | Put the filter on the cup. |
COF | Put the coffee in the filter. |
Timer Flashes | Ready to Brew |
-FLt- | Please remove filter. |
bxxxx,x | Beverage Weight |
xxx.x | Total Weight |
- As soon as weight is stabilized, the next step will show in the display.
- Timer starts when water pour is detected.
- Timer stops with a short press of ⏻ or when items (dripper) are removed.
- After the process, and the filter is removed, the display will blink/toggle the water weight and Beverage weight (marked with “b”).
To Enable/Disable Beverage Mode, please go to Chapter 5: Configuration on Page 16.
Mode 5 - Auto Tare Mode (after version 2.0.008)
Displays weight only. Place item on and off the scale, and it will automatically tare.
Action | Operation |
---|---|
Tare Weight | Short Press T |
Reset Mode | Double Tap T |
Switch Mode | Long Press ⏻ |
To Enable/Disable Auto Tare Mode, please go to Chapter 5: Configuration on Page 16.
Chapter 4: Calibration
Calibration Mode
- While the scale is in Weighing Mode and the weighing unit is in gram, press the Tare button (T) quickly multiple times until the LED display shows [CAL] and then [500].
- Place a 500g calibration weight on the scale and wait for the scale to execute the calibration procedure.
- The LED display shows [-End-] when the calibration procedure is completed. You may unload the calibration weight when completed.
Note: Calibration weight of 100g, 1000g, 1500g, or 2000g can also be used.
Chapter 5: Configuration
Enter Settings
- Press and hold the Power button (⏻) while turning ON the scale.
- Keep the Power button (⏻) pressed. When the LED display shows [ACAI A] and turns [SEt], Long Press the Tare button (T) for another 2 seconds without releasing the button.
- Release both Power (⏻) and Tare (T) buttons when the display shows [F.0000].
- Long Press the Tare button (T) to move the flashing digit to the right. Repeat this step 4 times to enter Settings. It will show the first setting [SLEEP].
Settings
Setting | Display | Options | Default |
---|---|---|---|
Auto Switch Off | SLEEP | 5, 10, 20, 30, 60, Off | 5 |
Auto Zero | O.AUto | On, Off | Off |
Zero Tracking | trAcE | 2d, 3d, Off | 2d |
Key Sound | bEEP | On, Off | On |
Zero Range | O.ranGE | 2, 100 | 100 |
Weighing Filter | Fi lt | 2, 4, 6, 8, 16, 32, 64, 128 | 16 |
Default Weighing unit | Unit | Gram, Ounce | Gram |
Weighing Resolution | rESoL | Default, High | Default |
Espresso Mode | NodE_1 | On, Off | Off |
Timer Mode | NodE_2 | On, Off | On |
Auto Start Mode | Node_3 | On, Off | Off |
Beverage Mode | NodE_4 | On, Off | Off |
Auto Tare Mode | NodE_5 | On, Off | On |
Bluetooth Password | rESEt.d | Yes, No | No |
Bluetooth On/Off | bt_SEt | On, Off | On |
Settings Operations:
Action | Operation |
---|---|
Next Setting | Short Press T |
Enter Setting | Long Press T |
Toggle Options | Short Press T |
Save Option | Long Press T |
Leave Setting | Short Press ⏻ |
Detailed Settings Explanations
Auto Sleep Settings
Auto Sleep Settings can also be configured in the Acaia App. The number indicates the amount of time before the scale enters sleeping mode. For example, when 10 is selected, the scale enters sleeping mode after 10 minutes of idling.
Auto Zero Settings
- When Auto Zero setting is off or disabled, the initial weight on the weighing pan must be less than 50% of capacity (i.e., less than 1kg for Acaia coffee scale) before the scale is turned on. Otherwise, an error [Er.303] occurs. When the error occurs, the scale would not work until the initial weight on the weighing pan is cleared.
- When Auto Zero setting is on or enabled, the scale displays the initial weight directly regardless of whether the weight is over 50% of capacity.
Zero Tracking
Zero Tracking is a function for maintaining the zero indication within certain limits automatically.
- OFF: It is not recommended to turn off Zero Tracking because the zero indication would drift easily with room temperature changes.
- 0.5d~3d: For example, since each division is 0.1g, 3d = 0.3g. When Zero Tracking is set to 3d, any initial weight between +/- 0.3g on the weighing pan would be zeroed out.
- 2d is recommended in general for Acaia coffee scale.
Key Sound Settings
Key Sound Settings can also be configured in the Acaia App. Set the Key Sound function off to turn off the beeping sound or on to turn on the beeping sound.
Zero Range Setting
Zero Range setting determines the range for which the Tare button (T) executes zero operation instead of tare operation.
- When Zero Range is set to 2, the range for zero-setting will be 2% of the capacity, i.e., +/- 40g for Acaia coffee scale. By pressing the Tare button (T), any weight within +/- 40g is zeroed out by zero operation, while any weight outside the range is tared out by tare operation.
- If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., +/- 2kg for Acaia coffee scale. Therefore, instead of tare operation, zero operation would be executed in this setting whenever the Tare button (T) is pressed.
Notice: The difference between zero operation and tare operation is that zero operation would simply ignore the weight and display as 0, while tare operation would deduct the weight from the weighing result. However, zero operation does not increase the scale capacity.
Weighing filter setting
The number shown on the LCD display indicates the current filter parameter which determines the speed for the load receptor to respond to weight and to determine the weighing value. The larger the number, the more stable but slower the weighing result will be.
Default Weighing Unit
The Default Weighing Unit is set to be gram.
Weighing resolution
- The default Weighing Resolution is set to [Default]: the division is 0.1g under weight of 1000g and 0.5g from 1000g to 2000g.
- When the Weighing Resolution is set to High, the division will be 0.1g throughout the entire time from 0g to 2000g.
Bluetooth Password
Bluetooth On/Off
Appendix
Error Code
Error Code | Description |
---|---|
100 | Code error |
101 | EEPROM error |
102 | AD read error |
Over load: the weight is over the maximum capacity. | |
Under load: the weight is under the minimum capacity. | |
303 | Unable to make zero point, for the initial weight exceeds the limit (50% of capacity). |
304 | Please do calibrate in a stable environment without wind or shake etc. |
802 | Unable to tare, for the weight exceeds the tare range. |
803 | Unable to tare, for the weight is unstable. |
900 | Password error (the default password is 0000) |
Copyright
The operation manual is protected by copyright. All rights reserved. No part of the operation manual may be reproduced, processed, duplicated or published in any form by photocopying, microfilming, reprinting or any other method, in particular electronic means, without the written agreement of Acaia.
© Acaia, Cupertino, CA, 2017.