Berker Blind Insert Comfort

Operation and Installation Instructions

Order No. 85 22 11 ..

Manufacturer: Berker GmbH & Co. KG, Zum Gunterstal, 66440 Blieskastel/Germany

Contact: Tel.: +49 6842 945 0, Fax: +49 6842 945 4625, E-Mail: info@berker.de, www.berker.com

Document Version: 04/2021, 6LE003246B

Safety Instructions

Design of the Device

The device comprises the following main components:

[Description of Figure 1: A visual representation of the shutter insert components, showing the main unit, frame, application module, dismantling screw, cover, and terminals.]

Function

Correct Use

Product Characteristics

Operation

These instructions detail the installation of the shutter insert. The operation and function of the application modules are described in their respective instruction manuals. The extension unit functionality is only enabled when an application module is attached to the master unit.

Information for Electricians

Assembly and Electrical Circuiting

Danger! Touching live parts can result in an electric shock. An electric shock can be lethal. Disconnect the connecting cables before working on the device and cover all live parts in the area!

Circuiting and Mounting of Shutter Insert

[Description of Figure 2: An electrical circuit diagram for the shutter insert, showing connections for Line (L), Neutral (N), motor (M), and a protective MCB max. 10 A.]

Individual Control with Push-button for Shutter Extension Unit

[Description of Figure 3: An electrical circuit diagram for individual control using a push-button as an extension unit.]

Individual Control with Key Push-button for Shutter Extension Unit

[Description of Figure 4: An electrical circuit diagram for individual control using a key push-button as an extension unit.]

Control by Sensors

Sensors, such as wind or precipitation sensors, are used to protect awnings from damage. If a threshold value is exceeded on the sensors, blinds/awnings are retracted.

When using sensors, the operating mode might need to be switched to protection mode (refer to Cover instructions).

[Description of Figure X: A diagram showing how to connect a sensor (7), such as a wind/precipitation sensor, according to the connection diagram.]

Master and Group Control

Circuit master and group control according to the circuiting diagram (Figure 5).

[Description of Figure 5: A diagram illustrating common wiring configurations for master and group control of multiple blind units.]

Master Control Under Application of Various RCCBs

Circuit master control when applying various Residual Current Circuit Breakers (RCCBs) according to the circuiting diagram (Figure 6).

[Description of Figure 6: A diagram detailing the wiring for master control, specifically when the system incorporates multiple Residual Current Circuit Breakers (RCCBs).]

Appendix

Technical Data

ParameterValue
Rated voltageAC 230 V, +10% /-15%
Mains frequency50/60 Hz
MCB (Device Protection)max. 10 A
Switching current (cos φ 0.6)3 A
Change-over time to the opposite running direction0.6 sec.
Standby power consumption< 0.1 W
Relative humidity0 ... 65% (no condensation)
Ambient temperature-5°C ... +45°C
Storage/transport temperature-20°C ... +60°C
Extension unit cable lengthmax. 50 m
Load cable lengthmax. 100 m
Number of extension unitsunlimited
Connecting terminal1 x 2.5 mm² or 2 x 1.5 mm²
Mounting orientationConnecting terminals downwards
Housing installation depth22 mm
Claw guidance installation depth32 mm

Accessories

Warranty

Berker reserves the right to make technical and formal changes to the product in the interest of technical progress. Products are under guarantee within the scope of statutory provisions. For warranty claims, please contact the point of sale or ship the device postage-free with a description of the fault to the appropriate regional representative.

Models: 85221100, Blind Insert Comfort, 85221100 Blind Insert Comfort, Insert Comfort, Comfort

File Info : application/pdf, 2 Pages, 2.30MB

PDF preview unavailable. Download the PDF instead.

852211XX JALOUSIE EINSATZ KOMFORT GB FR 6LE003246B

References

Adobe PDF Library 15.0 Adobe InDesign 16.1 (Windows)

Related Documents

Preview Berker Motion Detector 1.1m / 2.2m: Operation and Installation Guide
Comprehensive guide to the Berker motion detector (1.1m and 2.2m models), covering installation, operation modes, special functions, settings, and technical specifications. Learn how to optimize lighting control with this advanced motion sensing technology.
Preview Berker KNX Room Controller & Thermostat 80660100/80440100 Quick Start Guide
Quick start guide for Berker KNX room controller (80660100) and thermostat (80440100). Covers installation, UI navigation, settings, timer programs, and holiday mode for smart home climate control.
Preview Berker RT Touch Sensor with Room Temperature Control and Display: Operating and Fitting Instructions
Comprehensive guide for the Berker RT Touch Sensor, detailing its functions, operation, installation, and troubleshooting for room temperature control and building automation systems.
Preview Berker W.1 Intermediate Switch Surface-Mounted 30773505 Technical Specifications
Comprehensive technical datasheet for the Berker W.1 intermediate switch (model 30773505). Details include electrical features, materials, dimensions, connection type (Quickconnect), safety rating (IP55), and operating conditions for surface-mounted wet-room installations.
Preview Berker K.1 Frame 4-gang Horizontal Polar White Glossy - Product Information
Technical specifications for the Berker K.1 4-gang horizontal frame in polar white glossy finish. Includes details on mounting, materials, dimensions, and compatible accessories.
Preview Berker K.5 Frame 4-gang Vertical Stainless Steel - Product Information
Detailed product information for the Berker K.5 frame, 4-gang, vertical, made of stainless steel. Includes technical specifications, features, and compatible accessories.
Preview Berker SCHUKO Socket Outlet with LED Orientation Light Installation Guide
Installation instructions for the Berker SCHUKO socket outlet with LED orientation light, including assembly steps and functional testing.
Preview Berker KNX-Funk Universal Dimmer Actuator 1gang Flush-Mounted Operation Manual
Operation instructions for the Berker KNX-Funk Universal Dimmer Actuator 1gang flush-mounted (Order No. 8547 51 00), covering installation, operation, configuration, and technical specifications.