BLUETTI AC180T Portable Power Station
User Manual V2.0
Please read this manual carefully before use and keep it for future reference.
Important Safety Information
⚠️ Warning
- Charge the unit before first use.
- Do not use solar panels with open circuit voltage higher than 60V. Solar input voltage range for the unit is 12V-60VDC.
- Charge the unit immediately when the SoC drops below 5%. If the SoC drops to 0, power off the unit and charge it for at least 30 minutes before restarting.
- The unit is for off-grid use only. Do not connect its AC output to the grid.
- If not used for more than 3 months, charge the unit to 40%-60% SoC and store it with the power off. For optimum battery life, discharge and charge the unit every 3 months.
Thank You!
Thank you for making BLUETTI a part of your family. BLUETTI is committed to a sustainable future through green energy storage solutions, providing an exceptional eco-friendly experience for homes and the world. BLUETTI has a presence in over 100 countries and is trusted by millions of customers globally.
Notice
BLUETTI's products, services, and features are subject to agreed-upon terms and conditions during purchase. Some products, services, or features described in this manual may not be available under your purchase contract. BLUETTI makes no representations or warranties regarding the contents of this manual unless otherwise specified in the contract. The contents are subject to change without notice. Please refer to the latest version at: https://www.bluettipower.com/pages/user-guides. For questions or concerns, contact BLUETTI support.
1. Safety Instructions
Read this manual for proper use and safety information. The safety instructions are for illustrative purposes and actual operation must comply with all applicable safety standards. Contact BLUETTI support or dealers for any questions.
1.1 Statement
For safe operation, adhere to these conditions:
- Always operate or store the product within specified conditions.
- Avoid unauthorized disassembly, component replacement, or software modification.
BLUETTI is not liable for damages resulting from:
- Force majeure events (earthquakes, fires, storms, floods, mudslides).
- Damage from customer's transportation.
- Damage from inadequate storage conditions.
- Damage from customer negligence, improper operation, or intentional actions.
- System or hardware damage caused by third parties or improper handling/installation.
- Damage from unauthorized adjustments, changes, or removal of identification labels.
The product is not designed for high-performance UPS equipment in critical sectors (atomic energy, aviation, medical) or power-reliant equipment. BLUETTI assumes no liability for incidents involving personal safety, fire, equipment malfunction, data loss, or adverse aftermaths.
1.2 General Requirements
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Basic precautions must always be followed:
- Read all instructions before use.
- Avoid contact with liquids; do not use in the rain.
- Close supervision is necessary when the product is used near children.
- Do not insert fingers, hands, or foreign objects into any ports.
- Use of unrecommended attachments may cause fire, electric shock, or injury.
- Pull the plug, not the cord, when disconnecting.
- Do not use damaged or modified battery packs or appliances.
- Do not operate with damaged cords or plugs.
- Only authorized personnel should service the product; no end-user serviceable components. Seek qualified service for repair. Incorrect reassembly may cause fire or electric shock.
- Unplug before servicing to reduce electric shock risk.
- WARNING - RISK OF EXPLOSIVE GASES: Follow battery manufacturer instructions and cautionary markings.
- PERSONAL PRECAUTIONS: Wear eye protection and clothing. Avoid touching eyes near the battery. Never smoke or allow sparks/flames near the battery. Be cautious with metal tools near the battery to prevent sparks or short circuits. Ensure good ventilation when charging. Avoid contact with battery liquid; flush with water if contact occurs. Seek medical help for eye contact. Do not expose to fire or temperatures above 80°C (176°F) as it may cause an explosion. Use only identical replacement parts for servicing.
- Do not stack anything on the product during use or storage. Avoid moving the product while operating due to vibrations.
- Use only a dry powder fire extinguisher for fires.
- WARNING - RISK OF ELECTRIC SHOCK: Never use the product to power tools for cutting or accessing live parts or materials containing live parts.
- Only use detachable batteries with specified BLUETTI products.
1.3 Grounding Instructions
The product is designed for portable use and typically does not require earth grounding. However, if connected to the power grid, ensure proper grounding for safety. Grounding provides a path of least resistance for electric current to reduce electric shock risk in case of malfunction. The product is equipped with an AC power cord with an equipment-grounding conductor and a grounding plug. Plug into a properly installed and grounded outlet according to local codes.
WARNING: Improper connection of the grounding conductor can cause electric shock. Consult a qualified electrician if unsure. Do not modify the plug; have a proper outlet installed if it doesn't fit.
1.4 Handling Requirements
During transportation or storage, avoid dropping, impacting, or tilting the product to prevent internal damage. Use mechanical assistance (carts, workbenches) for safe handling.
Recommended number of people based on weight:
Weight | Number of people |
---|---|
<18kg (39.7lbs) | 1 |
18kg~32kg (39.7lbs~70.5lbs) | 2 |
32kg~55kg (70.5lbs~121.3lbs) | 3 |
>55kg (121.3lbs) | 4 or a cart |
1.5 Storage Instructions
- When SoC drops to 5%, charge the product immediately.
- Before storing, charge to 40%-60% SoC, power off, and disconnect all electrical connections.
- Store in a cool, dry place, away from flammable materials and gases.
- Safe storage temperature: -20°C to 40°C (-4°F to 104°F). For storage over one month, maintain around 30°C (86°F).
- Fully cycle the product every 3 months for battery health. Avoid prolonged storage as it may affect performance and lifespan.
If SoC drops to 0 (during storage or startup):
- Shut down immediately.
- Charge within 48 hours.
- Keep at ambient temperature of 5°C to 35°C (41°F to 95°F) for 6 hours before charging. Use AC source for charging; if using solar, ensure output is over 100W.
The symbol [Read Manual] reminds you to read the accompanying literature before operation and maintenance.
- Connect to a grounded socket-outlet using the provided power cord.
- Ensure the socket-outlet is near the product and easily accessible.
- Never dispose of batteries in fire, hot ovens, or by crushing/cutting, as this may cause explosion.
- Avoid high-temperature environments for batteries to prevent explosion or leakage.
- Low air pressure may cause battery explosion or leakage.
- Pay attention to environmental aspects of battery disposal.
- Refer to the exterior bottom enclosure for electrical and safety information before installation or operation.
SAVE THESE INSTRUCTIONS
BLUETTI is not liable for equipment damage caused by violating these instructions.
2. Packing List
Standard Accessories
Item | Picture Description | Qty. |
---|---|---|
AC180T Portable Power Station | Illustration of the BLUETTI AC180T Portable Power Station | 1 |
AC Charging Cable | Illustration of an AC charging cable | 1 |
Car Charging Cable | Illustration of a car charging cable | 1 |
Solar Charging Cable | Illustration of a solar charging cable | 1 |
Grounding Screws | Illustration of grounding screws | 1 |
User Manual | Illustration of the User Manual cover | 1 |
Warranty Card | Illustration of the Warranty Card | 1 |
Optional Accessories
(Available on the official BLUETTI website: https://www.bluettipower.com)
Item | Picture Description |
---|---|
USB-C to USB-C Cable (output) | Illustration of a USB-C to USB-C cable |
12V DC Power Cable | Illustration of a 12V DC power cable (for 12V devices with DC5521 port) |
3. Product Introduction
Meet the BLUETTI AC180T portable power station, a cutting-edge energy solution designed to enhance your mobile power experience. It features a robust 1,800W inverter and two 716.8Wh LiFePO4 batteries, providing ample power for your journeys.
The AC180T delivers up to 1,800W of AC output and a maximum combined AC+DC output of 1,900W. If total power demand exceeds 1,900W but AC loads stay below 1,800W, the unit intelligently turns off DC output while maintaining AC output. With Power Lifting Mode enabled, it can manage heating devices up to 2,700W, including hairdryers and heaters (refer to the "Settings" section for details).
A single battery can reach 80% charge in approximately 48 minutes; with two batteries, it takes about 60 minutes. It can also utilize sunlight for faster charging when away from an outlet.
Danger: Do not connect the AC output of AC180T to the grid.
4. Overview
Illustration showing the BLUETTI AC180T portable power station with numbered ports and controls.
Unit Overview
- 1. Cigarette Lighter Port
- 2. DC/PV Input
- 3. LCD Display
- 4. POWER Button
- 5. AC Outlet
- 6. AC Power Button
- 7. Breaker
- 8. AC Input
- 9. Grounding Pole
- 10. USB-A Port
- 11. USB-C Port
- 12. DC Power Button
4.1 Detachable Battery Overview
Illustration showing the detachable battery with numbered components:
- 1. Latch
- 2. Handle
- 3. Bleed Valve
- 4. Charging Port
- 5. Battery Indicator (1 light for 20% charge)
- 6. Power Button
5. Power ON / OFF
Attention: Place the unit firmly and stably.
Illustration of a hand pressing the POWER button on the AC180T unit, with the LCD display showing status.
- Power ON: Press the POWER Button.
- Power OFF: Press and hold the POWER Button for about 2 seconds.
- AC ON / OFF: When the AC180T is on, press the AC Power Button.
- DC ON / OFF: When the AC180T is on, press the DC Power Button.
- Restart: Power off the AC180T first, then press the POWER Button.
Note: When the AC180T is on, the LCD display can be activated by interacting with any button. The AC180T will automatically turn off if AC and DC are off for more than 1 minute.
6. LCD Display
The AC180T features an informative LCD display providing essential status and performance information. The display lights up when the unit is powered on and turns off when powered off.
Illustration of the AC180T LCD display with numbered indicators.
LCD Indicators:
- 1. Battery Connection
- 2. Silent Charging
- 3. DC Input
- 4. Bluetooth Connection
- 5. Fan Status
- 6. Turbo Charging
- 7. AC Input Power
- 8. AC Output Power
- 9. AC Output Voltage
- 10. AC Output Frequency
- 11. Grid Connection
- 12. DC Output
- 13. AC Output
- 14. Power Lifting Mode
- 15. Charge / Discharge Remaining Time
- 16. Charge / Discharge Status
- 17. Low Temperature Alert
- 18. High Temperature Alert
- 19. Overcurrent Alert
- 20. Overload Alert
- 21. Fault Alert
- 22. DC Output Power
- 23. Low Battery Alert
- 24. Battery Capacity (SoC)
- 25. DC Input Power
- 26. ECO Mode
- 27. Charge / Discharge Progress
LCD Instructions Summary:
Status | LCD Indication |
---|---|
Startup | LCD lights up |
Shutdown | LCD lights off |
Battery Icons | Each icon represents a battery; up to 2 can be displayed. |
Silent Charging Mode | [Silent Charging Icon] |
Charging from DC Source (Solar, etc.) | [DC Source Charging Icon] |
Bluetooth Connected | [Bluetooth Icon] |
Fan Activated | [Fan Icon] (Solid: working; Flashing: potential issue) |
Turbo Charging Mode | [Turbo Charging Icon] |
AC Charging Power | Real-time AC charging power (e.g., 8888W) |
Total AC Output | Real-time total AC output (e.g., 8888W) |
AC Output Voltage | Real-time AC output voltage (e.g., 888.8VAC) |
AC Output Frequency | Real-time AC output frequency (e.g., 60Hz) |
Charging from Home Grid | [GRID Icon] |
DC Output On | [DC Icon] |
AC Output On | [AC Icon] |
Power Lifting Mode | [Power Lifting Icon] |
Remaining Time | Charge or discharge remaining time (e.g., 88.8H) |
Charging Status | [Charging Icon] |
Discharging Status | [Discharging Icon] |
Temperature Too Low | [Low Temp Icon] |
Temperature Too High | [High Temp Icon] |
Overcurrent Draw | [Overcurrent Icon] |
Overload | [Overload Icon] |
Fault/Error | [Fault Icon] |
Real-time DC Output | Real-time DC output (e.g., 8888W) |
SoC Below 5% | [Low Battery Icon] |
Battery Capacity | Remaining battery capacity (%) |
Battery Level Mismatch | [Mismatch Icon] (Flashing) |
Real-time DC Input | Real-time DC input power (e.g., 8888W) |
ECO Mode Activated | [ECO Icon] |
Charge/Discharge Bar | Bar increases during charging, decreases during discharging. |
7. Charging
The AC180T supports four charging methods: AC, solar, car, and generator.
Attention:
- Ensure all cables are firmly plugged in.
- Avoid getting plugs and sockets wet to prevent damage.
7.1 AC Charging
Plug the AC180T into a standard wall outlet. It automatically stops charging when fully charged to prevent overcharging. For faster charging, enable Turbo Charging via the BLUETTI App for 80% capacity in approximately 48 minutes at 25°C (77°F).
Illustration showing AC charging via a wall outlet.
7.2 Solar Charging
Connect solar panels (in series or parallel) using the solar charging cable. With a continuous input of 500W, charging stops automatically after 2 hours (1 battery) or 4 hours (2 batteries). Charging time may vary based on weather, sunlight intensity, panel orientation, etc.
Note: Solar panel requirements: Voc 12V-60V, Current 10A Max., Power 500W Max.
Illustration showing solar charging with solar panels connected to the AC180T.
7.3 Car Charging
Connect the AC180T to a vehicle's 12V or 24V cigarette lighter port using the car charging cable. It charges at a maximum rate of 96W (12V port) or 192W (24V port). Charging stops automatically when full.
Note: Vehicle requirements: must be capable of supplying power, and the engine must be running during charging.
Illustration showing car charging via a vehicle's cigarette lighter port.
7.4 Generator Charging
Connect the AC180T to a generator via the AC charging cable. Charging stops automatically when fully charged.
Note: Ensure the generator's AC output voltage and frequency meet the AC180T's specifications. If connected devices' total power demand exceeds the generator's capacity, enable Grid Self-adaption Mode for seamless charging.
Illustration showing generator charging via an AC charging cable.
8. Discharging
8.1 AC Discharging
Port | Picture Description | Specifications | Description |
---|---|---|---|
AC Outlet x 4 | Illustrations of four AC outlets | 120V, 50Hz/60Hz | Appliances up to 1,800W power. |
8.2 DC Discharging
Port | Picture Description | Specifications | Description |
---|---|---|---|
Cigarette Lighter Port x 1 | Illustration of a 12V DC cigarette lighter port | 12V / 10A | 12V DC appliances up to 120W power (e.g., car refrigerator, air conditioner). |
USB-A x 2 | Illustrations of two USB-A ports | 5V / 3A | Mobile phones and other small loads. |
USB-C x 2 | Illustrations of two USB-C ports | 5/9/12/15/20V, 3A; 20V / 5A | Mobile phones, laptops, etc. |
Note: To ensure optimal performance, avoid short-circuiting ports and keep them dry. Do not block or cover ports to ensure proper ventilation.
9. Settings
The AC180T allows settings adjustment via physical buttons or the BLUETTI App. Control settings like ECO Mode, output frequency, and charging modes directly on the device or use the user-friendly app interface.
9.1 Setting Mode
When the AC180T is powered on, press and hold the AC and DC Power Buttons for over 1 second until the output frequency flashes to enter Setting Mode.
9.2 ECO Mode
The AC180T offers two ECO modes to save power and extend battery life:
- AC-ECO Mode: If AC power output falls below a certain level for a set period, AC power automatically turns off.
- DC-ECO Mode: If DC power output falls below a certain level for a set period, DC power automatically turns off.
Attention:
- AC-ECO and DC-ECO modes are enabled by default. It's recommended to keep them enabled.
- Use the BLUETTI App to enable/disable AC-ECO and DC-ECO modes separately. Using the LCD display turns them on/off simultaneously.
- To avoid charging interruptions for small devices, disable ECO Mode when their power consumption is below the set limit.
In Setting Mode, use the DC Power Button to navigate settings. When the [ECO Icon] flashes, press the AC Power Button to enable or disable ECO Mode.
9.3 Frequency Switching
The output frequency (50Hz / 60Hz) is displayed in the lower right corner. Ensure AC output is off before accessing Setting Mode and pressing the AC Power Button to switch frequency.
9.4 Power Lifting Mode
Designed for resistive loads up to 2,700W (e.g., electric blankets, kettles, hairdryers). Access Setting Mode, use the DC Power Button to find the [Power Lifting Icon] flashing, then press the AC Power Button to enable/disable.
Note: Power Lifting Mode is not enabled by default and is suitable for resistive loads between 1,800W-2,700W. The AC180T's actual operating power remains at 1,800W.
9.5 AC Charging Mode
The AC180T supports Standard, Turbo, and Silent AC charging modes. In Setting Mode, use the DC Power Button to navigate until the [Standard Icon] or [Silent Icon] flashes, then press the AC Power Button to select the mode.
Icon | Mode | Recharging Power (w/1 pack) | Recharging Power (w/2 packs) | Recharging Time | Note |
---|---|---|---|---|---|
None | Standard | 450W | 900W | 2 hours | Reduces battery wear and tear for long battery life. |
[Turbo Icon] | Turbo | 850W | 1440W | 1.5 hours (0-80% in 48 mins) | Handy when recharging time is a priority. |
[Silent Icon] | Silent | 360W Max. | 720W Max. | 4 hours | Offers quiet, low-power operation. |
9.6 Bluetooth On / Off
To connect to the BLUETTI App, turn on Bluetooth first. In Setting Mode, use the DC Power Button to navigate. When the [Bluetooth Icon] flashes, press the AC Power Button to toggle Bluetooth.
9.7 Grid Self-adaption Mode
If charging with a generator or unstable grid voltage, and connected devices' power demand exceeds the AC180T's input power, enable Grid Self-adaption Mode via the BLUETTI App for stable and safe charging.
9.8 Exit Setting Mode
To save settings and exit Setting Mode, press and hold both AC and DC Power Buttons simultaneously. If no operation is performed for 1 minute, the unit will exit Setting Mode automatically without saving changes.
10. BLUETTI App
Scan the QR code below or search "BLUETTI" in the App Store or Google Play to download the BLUETTI App. For more details, refer to the BLUETTI APP INSTRUCTIONS.
QR Code placeholder: [QR Code for BLUETTI App Download]
11. Specifications
Specifications for the AC180T across different regions (JP, US, CN, EU, AU):
Model (Country / Region) | AC180T (JP) | AC180T (US) | AC180T (CN) | AC180T (EU) | AC180T (AU) |
---|---|---|---|---|---|
Battery Capacity | (716.8Wh / 28Ah)×2pcs | ||||
Cell Type | Lithium Iron Phosphate (LiFePO4, LFP) | ||||
AC + DC Input | 1,940W Max. | ||||
Weight | AC180T: 26.5kg / 58.4lbs (w/ 2 batteries) Battery: 8.5kg / 18.7lbs |
||||
Dimensions (L × W × H) | AC180T: 390mm × 280mm × 395mm / 15.4in × 11.0in × 15.6in Battery: 134mm × 160mm × 350mm / 5.3in × 6.3in × 13.8in |
||||
Charging Temperature | 0°C to 40°C / 32°F to 104°F | ||||
Discharging Temperature | -20°C to 40°C / -4°F to 104°F | ||||
Storage Temperature | -20°C to 40°C / -4°F to 104°F | ||||
Working Humidity | 10% to 90% | ||||
AC Output | |||||
Power | 1,800W (with 2 batteries or with Grid) / 1,200W (with 1 battery and without Grid) | ||||
Surge Power | 3600W@1s | ||||
Overload Power | 1890W~2160W@120s / 2160W~2700W@10s / 2700W~3600W@1s | ||||
Voltage | 100V | 120V | 220V | 230V | |
Current | 18A | 15A | 8.2A | 7.8A | |
Frequency | 50Hz/60Hz | ||||
DC Output | |||||
Cigarette Lighter Port x 1 | 12V / 10A | ||||
USB-A x 2 | 5V / 3A | ||||
USB-C x 2 | 5/9/12/15/20V, 3A; 20V / 5A | ||||
DC Output Power | 365W Max. | ||||
AC Input | |||||
Voltage | 100V | 120V | 220V | 230V | |
Charging Current | 14.4A Max. | 12A Max. | 6.6A Max. | 6.3A Max. | |
Input Current | 15A Max. | 15A Max. | 9.3A Max. | 9A Max. | |
Frequency | 50Hz/60Hz | ||||
UPS | Switching time ≤20ms | ||||
Charging Power | 1,440W Max. (w/ 2 batteries) / 850W Max. (w/1 battery) |
DC Input
Parameter | Specification |
---|---|
Interface | XT60PM-M |
Power | 500W Max. |
Current | 10A Max. |
Voltage | 12V to 60V |
Other Parameters
Parameter | Specification |
---|---|
AC + DC/PV Charging Power | 1,940W Max. (w/ 2 batteries) / 1080W Max. (w/1 battery) |
AC + DC Output Power (without GRID) | 1,900W Max. (w/ 2 batteries) / 1200W Max. (w/1 battery) |
12. Button Operation Instructions
Operation | Function | Description |
---|---|---|
Press the AC Power Button | Turn on/off the AC output | / |
Press the DC power button | Turn on/off the DC output | / |
Press the AC and DC Power Buttons simultaneously and hold for more than 1 second till the output frequency flashes | Enter / exit the Setting Mode | In Setting Mode, enabled function icons remain lit, except for the flashing output frequency icon. If no operation occurs for 1 minute, the unit exits Setting Mode automatically without saving changes. |
Press the DC Power Button in the Setting Mode | Navigate through the setting items | The flashing setting item is editable. Codes displayed: P01: Output Frequency, P03: Charging Mode, P04: Power Lifting Mode, P05: ECO Mode, P06: Bluetooth. |
Press the AC Power Button when the setting item is flashing | Enable or disable the selected function | / |
Press and hold the DC Power Button in the Setting Mode | Switch the status page | View relevant information: [Serial Number Icon], [Error Code Icon], [Historical Faults Icon], [Version Icon]. |
13. Troubleshooting
In Setting Mode, press and hold the DC Power Button for over 2 seconds to display error codes. Refer to the table below for guidance.
Error Code | Alarm Icon Description | Troubleshooting |
---|---|---|
E001 | [Inverter Overload Icon] Inverter overload | Check if device power consumption is too high. Reduce load if necessary. |
E002 | [Inverter Overtemp Icon] Inverter overtemperature protection, AC output off | Wait about 10 minutes for the unit to cool down, then turn on AC output again. |
E003 | [Inverter Short Circuit Icon] Inverter short circuit | 1. Check if device power consumption is too high. 2. Check if any electrical devices are causing a short circuit. |
E033 | [PV Overvoltage Icon] PV overvoltage | Ensure PV input voltage is within 12V to 60VDC range. |
E039 | [PV Overtemp Icon] PV overtemperature | Wait about 10 minutes for the unit to cool down, then re-enable PV input. |
E065 | [DC Output Short Circuit Icon] DC output short circuit | 1. Check if device power consumption is too high. 2. Check if any electrical devices are causing a short circuit. |
E067 | [DC Output Overcurrent Icon] DC output overcurrent | Check if device power consumption is too high. Reduce load if necessary. |
E068 | [DC Output Overtemp Icon] DC output overtemperature | Wait about 10 minutes for the unit to cool down, then restart your devices. |
E085 | [Charging Temp High Icon] Charging temperature too high | Wait for the unit to cool down before charging. |
E086 | [Charging Temp Low Icon] Charging temperature too low | Ensure the unit is placed in an ambient temperature of 0°C to 40°C (32°F to 104°F). |
E087 | [Discharging Temp High Icon] Discharging temperature too high | Wait for the unit to cool down before discharging. |
E088 | [Discharging Temp Low Icon] Discharging temperature too low | Ensure the unit is placed in an ambient temperature of -20°C to 40°C (-4°F to 104°F). |
E113 | [Grid Overvoltage Icon] Grid overvoltage | Check if grid voltage is too high. Change input source if necessary. |
E114 | [Grid Undervoltage Icon] Grid undervoltage | Check if grid voltage is too low. Change input source if necessary. |
E115 | [Grid Overfrequency Icon] Grid overfrequency | Check if grid frequency is too high. Contact your local power provider if necessary. |
E116 | [Grid Underfrequency Icon] Grid underfrequency | Check if grid frequency is too low. Contact your local power provider if necessary. |
Others | / | Please contact BLUETTI support for assistance. |
Appx. 1 Estimating Operation Time
To estimate operation time, consider the load:
- For high-power loads (above 300W):
Operation time = Battery Capacity (Wh) × DoD × η ÷ Load Power - For small-power loads (below 300W):
Operation time = Battery Capacity (Wh) × DoD × η ÷ (Load Power + AC180T Self-consumption)
Note: DoD (Depth of Discharge) is typically 90% for AC180T for longer battery life. η (eta) is the inverter conversion efficiency, usually over 90%. AC180T self-consumption is approximately 15W.
Example: For a 65W refrigerator, operation time is approximately 14 hours.
Operation time = (716.8 × 2) Wh × 90% × 90% ÷ (65W + 15W) ≈ 14 hours.
Estimated operation time is for reference and may vary based on actual usage conditions. Factors like low temperature and excessive loads can affect battery capacity.
Appx. 2 FAQ
- Q1: How do I know whether my devices will work well with this product?
A: Evaluate the total constant load of your devices. If it does not exceed the Max. output power (1,800W with 2 batteries or 1,200W with 1 battery), it should work. Note: Devices with built-in motors or compressors may have higher start-up power (2-4 times rated power), potentially overloading the AC180T. - Q2: Can I use third-party solar panels to charge this product?
A: Yes, provided they have an open circuit voltage of 12V-60V and MC4 connectors. Do not mix different types of solar panels. - Q3: Can it charge and discharge at the same time?
A: Yes, it supports pass-through charging. The AC180T's LiFePO4 battery and BMS ensure simultaneous charging and discharging. - Q4: Why is the charging power often too low?
A: The AC180T has an intelligent BMS that adjusts charging power based on battery temperature and SoC to protect the battery and extend its service life.
Appx. 3 Abbreviation
- MPPT: Maximum Power Point Tracking
- SoC: State of Charge
- UPS: Uninterruptible Power Supply
- AC: Alternating Current
- DC: Direct Current
- PV: Photovoltaic
- DoD: Depth of Discharge
Appx. 4 FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with Class B digital device limits per FCC Rules, designed for reasonable protection against harmful interference in residential installations. It generates, uses, and radiates radio frequency energy. If not installed/used per instructions, it may cause radio communication interference. Interference is not guaranteed to not occur in a particular installation. If interference occurs (determined by turning off/on), try correcting it by:
- Reorienting or relocating the receiving antenna.
- Increasing separation between equipment and receiver.
- Connecting to a different circuit than the receiver.
- Consulting a dealer or experienced radio/TV technician.
FCC Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
IMPORTANT NOTE: FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits for an uncontrolled environment. Install and operate with a minimum distance of 20cm between the radiator and your body.
Appx. 5 IC Caution
This device contains licence-exempt transmitter(s)/receiver(s) complying with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation.
RF exposure statement: The equipment complies with IC Radiation exposure limits for uncontrolled environments. Install and operate with a minimum distance of 20cm between the radiator and your body.
CAN ICES-3 (B)/NMB-3(B) (Canada)
This Class B digital apparatus complies with Canadian ICES-003.
Appx. 6 Consignes de sécurité [Safety Instructions in French]
This section contains safety instructions in French. For detailed safety information, please refer to the English sections above.
Contact Information
For more information, please visit:
Web: https://www.bluettipower.com
Social Media:
- @bluetti_inc
- @bluetti.inc
- @bluetti_official
Customer Service:
- Tel: 800-200-2980 (Monday to Sunday 9:00-17:00)
- Email (Pre-sales): sale@bluettipower.com
- Email (After-sales): service@bluettipower.com
Manufacturer: SHENZHEN POWEROAK NEWENER CO., LTD.
Add: F19, BLD No.1, Kaidaer, Tongsha Rd No.168, Xili Street, Nanshan, Shenzhen, China
USA Agent:
Company: BLUETTI POWEROAK INC
Add: 6185 S VALLEY VIEW BLVD STE D LAS VEGAS NEVADA 89118 United States
FRN: 0033559824
Part Number: P/N:17.0303.0649-01A1
Certificate
Inspector: ____________________
QC: ____________________