E16BP Smart Toilet Installation Manual
Safety Instructions
Important Safeguards
When using electrical products, especially when children are present, basic safety precautions should always be followed:
- The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
DANGER: Risk of Electrocution
To reduce the risk of electrocution:
- Do not use while bathing.
- Do not place or store the product where it can fall or be pulled into a tub or sink.
- Do not place in or drop into water or other liquid.
- Do not reach for a product that has fallen into water; unplug immediately.
- Do not wash the main unit or electrical plug with water or detergent.
- Do not handle the electrical plug with wet hands.
- Never block the outlet of the air dryer.
- Never disassemble, repair, or modify this product.
- During installation, disassembly, repair, and maintenance, the power plug must be switched off and the water supply shut off.
WARNING: Risk of Burns, Electrocution, Fire, or Injury
To reduce the risk of burns, electrocution, fire, or injury to persons:
- Close supervision is necessary when this product is used by, on, or near children or individuals with disabilities.
- Use this product only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
- Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water; return the product to a service center for examination and repair.
- Keep the cord away from heated surfaces.
- Never use while sleeping or drowsy.
- Never drop or insert any object into any opening or hose.
- Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered.
- Connect this product to a properly grounded outlet only. See Grounding Instructions.
- Do not throw cigarettes and other burning materials into the toilet, as this might cause a fire.
- This product is an electric appliance and must be placed far from water and other liquids.
- Do not lay the product on its side or upside down during operation.
- Using other electric appliances in the same socket is prohibited.
- Using power extensions or unstable loose outlets is forbidden.
- Do not reuse existing water supply hoses, as they might cause leakage, fire, or electrical shock. Installation must include specified components and a new water supply hose.
CAUTION: Injury or Property Damage
Indicates that failure to follow the instructions may cause body injury or property damage.
- Do not install or use the product in wet places such as steam rooms.
- It is recommended to use a waterproof electrical outlet installed in a location not easily exposed to moisture.
- This product must be used with 110V-120V, 60Hz electrical current only, with a load current of at least 15A. The power plug must be equipped with a ground fault circuit interrupter or a similar high-sensitivity, rapid-acting leakage switch (rated sensitive current under 6mA).
- During thunderstorms, it is strongly recommended to unplug the power cord.
- Do not stand on the ceramic toilet.
- Ceramic toilets must be installed with floor fixing bolts.
- Do not stand on the product unit, seat, or lid.
- Do not lean against the seat lid when using the product to avoid damage.
- The product is equipped with a soft-closing seat lid; do not force it closed, as damage may occur.
- Do not use caustic chemicals or scrubbing brushes to clean this product.
- Exposure to direct sunlight is prohibited.
- Use only tap water or potable water; otherwise, it may cause surface damage.
- Do not connect the water supply to the heater outlet. Ensure the inlet water temperature is between 3°C-35°C (37.4°F-95°F).
- When the room temperature is below freezing (0°C), drain the water tank to prevent freezing.
- Increase room temperature to prevent damage from freezing.
- When moving the product from a cold or wet environment to normal room temperature, wait for 2 hours for condensation water to fully evaporate to prevent electrical short-circuits.
- If the product is not used for over three (3) days, drain the water and unplug the electrical cord.
- Stop using the product and shut off the power if it malfunctions; call for professional service.
Grounding Instructions
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord and grounding plug, which must be connected to a properly installed and grounded outlet.
DANGER: Improper use of the grounding plug can result in a risk of electric shock. If the cord or plug requires repair or replacement, do not connect the grounding wire to any flat blade terminal. The grounding wire is identified by its green insulation, with or without yellow stripes. The product comes with a specific cord and plug for connection to a suitable electric circuit. Ensure the product is connected to an outlet with the same configuration as the plug; do not use adapters. Do not modify the provided plug; if it does not fit the outlet, have a qualified electrician install the proper outlet. Reconnection for use on a different type of electric circuit should only be performed by qualified service personnel.
Technical Specifications
Feature | Specification |
---|---|
Main Unit | |
Rated voltage | 110V-120V, 60Hz |
Rated power | 865W |
Water proof | IPX4 |
Power cord length | About 1.8m |
Flush volume | 1.6/1.1Gpf, 6.0L (full flush) / 4.1L (half flush) |
Flushing mode | Siphonic jet |
Rough-in | 305mm |
Outlet outside diameter | 100mm |
Drainage method | S-trap |
Water pressure range | 0.07MPa-0.8MPa (static water pressure) |
Cleaning Device | |
Heating mode | Instant |
Heating power | 1400W |
Water temperature | 6-level adjustment |
Water volume | 3-level adjustment |
Cleaning mode | Rear washing / Oscillating washing, Front washing / Oscillating washing |
Nozzle position | 5-level adjustment |
Water pressure protector | Pressure maintaining device, Automatic pressure relief device |
Anti-fouling device | Automatic nozzle cleaning, Anti-syphon device, Anti-backflow device, Filter device |
Safety device | Thermal fuse, Water temperature sensor, Thermostat, Over temperature protection, Ground protection, Leakage protection plug |
Drying Device | |
Warm air volume | Over 0.2m³/min |
Warm air temperature | 6-level adjustment |
Heating power | 250W |
Safety device | Thermal fuse, Leakage protection plug, Thermostat |
Deodorization | |
Deodorization method | Diatom Deodorization |
Heated Seat | |
Surface temperature | 6-level adjustment |
Heating power | 50W |
Open and close device | Quiet soft-close |
Burn protection | After 10 minutes of use, the seat temperature will automatically drop slowly to a low level. |
Safety device | Seat sensor, Temperature sensor, Thermal fuse, Thermostat, Leakage protection plug |
Night light assembly | |
Functionality | Intelligent, Always off |
User ID setting | |
To avoid interference when used by multiple users | |
Automatic flushing | |
Toilet will automatically flush as user walks away from bowl | |
Caring device | |
Toilet will be washed manually after power failure (Please install the battery before use when it is available.) | |
Power off flush | |
Foot sensor flushing | |
Foot sensor flushing function | |
Touch the sensing area with foot to activate a half flush | |
Antibacterial site | |
Seat, nozzle | |
Rated power condition: Under ambient temperature 23°C/73°F, water static pressure 0.18MPa±0.02MPa, water temperature 15°C/59°F, power toilet on, set water pressure, seat temperature, water temperature to the highest level in turn and perform one rear washing cycle. |
List of Materials
- Main Unit
- Sealing Flange
- Installation Manual
- NPT 1/2 Angle Valve
- Battery Box (battery not supplied)
- Remote Control Components
- Installation Cardboard
- Braided Hose (Installed)
- Mounting Kit
Technical Drawing
This section displays a technical drawing of the EPLO E16BP Smart Toilet, showing overall dimensions including height (970mm), width (410mm), and depth (690mm). It also indicates the toilet's footprint and bowl shape. A note states that the drawing is for reference only and the manufacturer reserves the right to modify product appearance.
Parts Identification
This section identifies key components of the EPLO E16BP Smart Toilet. On the left side, components include the Lid, Indicator light, and Button. On the right side, features like Rear washing, Front washing, Washing baffle, and Drying baffle are indicated. The Spray nozzle, Bumper, Seat, Ceramic toilet, and Remote control sensor are also highlighted. The sensor area for foot-activated half flush is noted.
Toilet Installation
- Installation of Angle Valve: Draw a drain outlet centerline on the floor. Install the angle valve at the proper position on the wall according to the toilet's dimensions. Use the supplied angle valve, which includes a filter, to prevent blockages. If replacing an existing angle valve, contact a professional.
- Installation of Battery Box: Before activating the power-off flushing function, install a 9V alkaline battery (not supplied) into the battery box. Connect the battery connection cable from the rear side of the seat cover to the female end of the battery box. Remove the sticker on the velcro at the bottom of the battery box and place it in the proper position on the ceramic back for easy removal. It is recommended to use a high-quality 9V dry battery (e.g., 6LR61 or 6F22) and replace it every two years to prevent leakage. Professional installation is recommended.
- Cardboard Installation: Align the cardboard with the centerline of the drain outlet. Draw the contour line according to the cardboard.
- Hose Connection: Connect the water inlet of the toilet to the angle valve using the matching flexible hose and tighten it. Use the supplied water supply hose for optimal flushing performance.
- Mounting Bracket Installation: Assemble the mounting bracket with bolts and install them to the pre-installed flange plate on the ground, locking them tight with nuts.
- Ceramic Toilet Installation: Install a sealing flange into the drain outlet. Install the ceramic toilet onto the corresponding position, ensuring the toilet outlet sits perfectly on the drain outlet. Two people are required to carry the toilet. Clean the drain outlet before installation.
- Screw Installation: Insert the screw through the fixing sleeve, then through the holes on both sides of the toilet ceramic, and into the mounting bracket on the ground. Lock tight. Install the decorative cap onto the fixing sleeve.
Preparation
- Turn on the Angle Valve: Check the threaded connection for leaks to ensure complete sealing. Turn the angle valve counterclockwise to the full open position. Note that the angle valve may require significant torque for the first opening.
- Power Connection: Insert the leakage protection plug into a power socket. Press the reset switch; the plug indicator light should illuminate, indicating power is on. It is recommended to press the TEST button prior to usage to confirm the leakage protection function is normal. Press the TEST button (then the RESET button) monthly to assure proper operation.
- Self-inspection: Upon initial power-up, the main unit buzzer will sound "beep". The indicator light sequence will be: first blue light on, then blue light off, then red light up, indicating the start of self-inspection. The buzzer will beep again upon completion. The product is then ready for use.
Maintenance
Main Unit Care and Maintenance
- Shut off the power supply before performing any maintenance.
- Use only a soft, damp cloth for cleaning. Avoid using harsh chemicals.
- Once cleaning is completed and all surfaces are dry, reconnect the power plug.
Spray Nozzle Maintenance and Care
- When no one is seated, short press the "REAR/MOVE" button on the main unit to automatically extend the nozzle for cleaning access.
- When the nozzle moves forward, it can be removed for separate cleaning.
- Use only a soft cloth or soft brush to clean the nozzle. Do not pull or push the wand to avoid damage.
- After cleaning, place the nozzle back and short press the "Stop" button to retract the spray wand to its normal position.
Filter Maintenance
If poor spray performance occurs under normal conditions:
- Turn off the power and the angle valve.
- Unscrew the angle valve nut.
- Remove the filter net.
- Clean the filter net under running water using a toothbrush.
- Reinstall the filter and angle valve nut.
- Turn on the angle valve and connect the power.
Emergency Troubleshooting
No water from nozzle / Poor water spraying / Low water temperature
- Cause: Water supply hose is kinked. Solution: Straighten the hose.
- Cause: Angle valve is off. Solution: Turn on the angle valve.
- Cause: Water supply failure occurred. Solution: Restore the water supply.
- Cause: Angle valve is not fully turned on. Solution: Turn on the angle valve fully.
- Cause: Filter is clogged. Solution: Clean the filter.
- Cause: Water temperature is not set properly. Solution: Adjust the water temperature.
- Cause: Low seat temperature. Solution: Adjust the seat temperature.
- Cause: In standby mode or energy saving mode. Solution: Switch to functional mode and wait for 3+ minutes.
- Cause: Low dryer temperature. Solution: Adjust the dryer temperature.
Dryer not blowing
- Cause: In standby mode. Solution: Switch to functional mode to use the dry function.
Spray wand cannot retract / Spray wand cannot stretch out
- Cause: Power off. Solution: Turn on the power. Push back the spray wand gently.
- Cause: Get stuck by impurities. Solution: Remove the impurities.
- Cause: User is not within the sensing area of the seat. Solution: Adjust position on seat to activate the sensor.
Remote control cannot display / Malfunction of deodorization
- Cause: The positive and negative direction of the batteries is incorrect. Solution: Reload the batteries correctly.
- Cause: Low battery. Solution: Replace with new batteries.
- Cause: User is not within the sensing area of the seat. Solution: Adjust position on seat to activate the sensor.
- Note: It is normal for the deodorizing function to continue operating after the user leaves, for complete odor removal.
Manual flushing cannot work during power failure
- Cause: No or low battery. Solution: Replace new batteries for power failure flushing.
If the problem cannot be resolved as per above solutions, please disconnect the power and contact service providers.
Caution: If the power leakage protection switch always trips, it means that the product is leaking. Please disconnect the power and contact service providers.
Description of Indicator Light
The indicator lights display various states:
- When the unit starts up, it displays water temperature information by default: Temperature display light, water temperature indicator, and separator are all on. Seat temperature indicator and ECO indicator are 50% on.
- If water temperature is not neutral and seat temperature is adjusted, after 5 seconds, it switches to water temperature display: water temperature indicator, separator, and temperature display light are all on. ECO indicator and seat temperature indicator are 50% on.
- If water temperature is neutral, it switches to seat temperature adjustment display: seat temperature indicator, separator, and temperature display light are all on. ECO indicator and water temperature indicator are 50% on.
- If both water temperature and seat temperature are neutral, water temperature indicator, seat temperature indicator, and ECO indicator are 50% on. The separator is 100% on, and no temperature is displayed.
- Under ECO mode: When the user leaves the seat, the ECO indicator and separator are 100% on; water temperature indicator and seat temperature indicator are 50% on, with no temperature displayed. When the user is seated, the ECO indicator is 50% on, the separator is 100% on, and indicators and temperature display as adjusted.
Troubleshooting Guide
Problem | Cause | Solution |
---|---|---|
No water from nozzle | Water supply hose is kinked | Straighten the hose to remove the kink |
Angle valve is off | Turn on the angle valve | |
A water failure occurred | Restore the water supply | |
Poor water spraying | Water supply hose is kinked | Straighten the hose to remove the kink |
Angle valve is not fully turned on | Turn on the angle valve fully | |
Filter is clogged | Clean the filter | |
Low water temperature | The water temperature is not set properly | Adjust the water temperature |
Low seat temperature | The seat temperature is not set properly | Adjust the seat temperature |
In standby mode or energy saving mode | Switch to functional mode and wait for 3+ minutes | |
Low dryer temperature | The dryer temperature is not set properly | Adjust the dryer temperature |
Dryer not blowing | In standby mode | Switch to functional mode to use dry function |
Spray wand cannot retract | Power off | Turn on the power. Push back the spray wand gently. |
Spray wand cannot stretch out | Get stuck by impurities | Remove the impurities |
User is not within the sensing area of the seat | Adjust position on seat to activate the sensor | |
Remote control cannot display | The positive and negative direction of the batteries is incorrect | Reload the batteries correctly |
Low battery | Replace with new batteries | |
Malfunction of deodorization | User is not within the sensing area of the seat | Adjust position on seat to activate the sensor |
Deodorization function continues after user leaves. | It is normal for the deodorizing function to continue operating after user leaves, for complete odor removal. | |
Manual flushing cannot work during power failure | No or low battery | Replace new batteries for power failure flushing |
If the problem cannot be resolved as per above solutions, please disconnect the power and contact service providers.
Caution: If the power leakage protection switch always trips, it means that the product is leaking. Please disconnect the power and contact service providers.
Notes
The picture of the product may not be entirely consistent with the actual appearance and color due to product improvements. Please refer to the actual product.