Mitsubishi Electric MSZ-HX09NL & MUZ-HX09NL
9,000 BTU/H Wall-Mounted Indoor Unit & 9,000 BTU/H Inverter Heat Pump Outdoor Unit
Job Name: [Not Specified]
System Reference: [Not Specified]
Date: [Not Specified]
Indoor Unit Model: MSZ-HX09NL
Outdoor Unit Model: MUZ-HX09NL
Indoor Unit Features
- 12-hour timer
- Auto restart
- Dual Barrier Coating: The patented Dual Barrier Coating reduces the collection of contaminants like dust, fibers, smoke, and oil on the inner surface of the heat pump, resulting in optimal airflow and easier maintenance. (HX Fan Only)
- Econo Cool: Econo Cool temporarily and automatically adjusts the airflow based on heat exchanger temperature. The set temperature is increased slightly, which saves energy, while maintaining comfort.
- Electrostatic Enzyme Filter: Charged with static electricity, the Electrostatic filter is designed to attract and filter charged particles which can include airborne non-living particulates.
- Four fan speed options: Low, Medium, High, Super-high
- Multiple control options including: Hand-held Remote Controller (provided with unit), comfort app, third-party interfaces and both wired and wireless controllers
- Smart Dry Mode: Improves humidity control with minimal over-cooling of the space
Outdoor Unit Features
- Blue Fin Coating: An anti-corrosion treatment applied to the aluminum fins of the heat exchanger of the outdoor unit to protect against corrosion caused by salt, sulfur, and other airborne contaminants, especially in coastal and industrial areas.
- INVERTER-driven compressor: An inverter-driven compressor generates the precise capacity needed to maintain a temperature set point.
- Powered by Outdoor Unit: The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns.
Specifications
Cooling Performance
Parameter | Unit | Value |
---|---|---|
Maximum Capacity | Btu/h | 11,000 |
Rated Capacity | Btu/h | 9,000 |
Minimum Capacity | Btu/h | 3,600 |
Maximum Power Input (at 95°F) | W | 1,100 |
Rated Power Input (at 95°F) | W | 720 |
Moisture Removal | Pints/h | 1.6 |
Sensible Heat Factor | - | 0.8 |
Power Factor [208V/230V] | % | 89/89 |
Heating Performance
Parameter | Unit | Value |
---|---|---|
Heating at 47°F: Maximum Capacity | Btu/h | 13,000 |
Heating at 47°F: Rated Capacity | Btu/h | 10,900 |
Heating at 47°F: Minimum Capacity | Btu/h | 4,000 |
Heating at 47°F: Maximum Power Input | W | 1,400 |
Heating at 47°F: Rated Power Input | W | 900 |
Heating at 47°F: Power Factor [208V/230V] | % | 91/91 |
Heating at 17°F: Maximum Capacity | Btu/h | 7,200 |
Heating at 17°F: Rated Capacity | Btu/h | 6,800 |
Heating at 17°F: Maximum Power Input | W | 1,230 |
Heating at 17°F: Rated Power Input | W | 820 |
Heating at 5°F: Maximum Capacity | Btu/h | 7,700 |
Heating at 5°F: Maximum Power Input | W | 1,250 |
Heating at -5°F: Maximum Capacity | Btu/h | 6,420 |
Efficiency
Parameter | Unit | Value |
---|---|---|
SEER2 | - | 20 |
EER2 | - | 12.5 |
HSPF2 [IV] | - | 10 |
COP at 47°F | - | 3.55 |
COP at 17°F (at Maximum Capacity) | - | 1.7 |
COP at 5°F (at Maximum Capacity) | - | 1.8 |
COP at -5°F (at Maximum Capacity) | - | 1.48 |
ENERGY STAR® Certified | - | Yes |
Electrical
Parameter | Unit | Value |
---|---|---|
Voltage, Phase, Frequency | VAC/VAC, Ø, Hz | 208/230, 1, 60 |
Guaranteed Voltage Range | VAC | 187-253 |
Voltage: Indoor - Outdoor, S1-S2 | VAC | 230 |
Voltage: Indoor - Outdoor, S2-S3 | V DC | 24 |
Short-circuit Current Rating [SCCR] | kA | 5 |
Recommended Fuse/Breaker Size (Outdoor) | A | 15 |
Recommended Wire Size [Indoor - Outdoor] | AWG | 14 |
MCA | A | 1 |
Indoor Unit Specifications
Parameter | Unit | Value |
---|---|---|
Fan Motor Output | W | 30 |
Airflow Rate at Cooling, Dry | CFM | 144, 211, 296, 379 |
Airflow Rate at Cooling, Wet | CFM | 129, 190, 267, 342 |
Airflow Rate at Heating, Dry | CFM | 144, 221, 317, 390 |
Sound Pressure Level [Cooling] | dB (A) | 22, 30, 37, 43 |
Sound Pressure Level [Heating] | dB (A) | 22, 30, 37, 43 |
Drain Pipe Size O.D. | inch [mm] | 5/8 [15.88] |
Dual Barrier Coating on Heat Exchanger | - | No |
External Finish Color | - | Munsell 0.7PB 9.2/0.4 |
Unit Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 33 x 9-1/4 x 11-1/32 [838 x 235 x 280] |
Package Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 36 x 13-1/4 x 11-1/2 [920 x 340 x 300] |
Unit Weight | lbs [kg] | 20 [9] |
Package Weight | lbs [kg] | 24 [10.50] |
Fan Motor Type | - | DC Motor |
IDU Operating Temp. Range (Cooling Intake Air Temp [Max/Min]) | °FDB, °FWB / °FDB, °FWB | 90, 73 / 67, 57 |
IDU Operating Temp. Range (Heating Intake Air Temp [Max/Min]) | °FDB | 80 / 70 |
Outdoor Unit Specifications
Parameter | Unit | Value |
---|---|---|
MCA | A | 10 |
MOCP | A | 17 |
Fan Motor Full Load Amperage | A | 0.71 |
Fan Motor Output | W | 55 |
Airflow Rate Cooling | CFM | 1,141 |
Airflow Rate Heating | CFM | 1,196 |
Defrost Method | - | Reverse Cycle |
Coating on Heat Exchanger (Bluefin, Sea Coast) | - | Yes, Yes |
Sound Pressure Level, Cooling | dB (A) | 46 |
Sound Pressure Level, Heating | dB (A) | 50 |
Compressor Type | - | Single Rotary |
Compressor Model | - | KRB073FATMC |
Compressor Oil [Type // Charge] | Type // oz | RM68EH // 9.13 |
External Finish Color | - | Munsell 3Y 7.8/1.1 |
Base Pan Heater | - | Optional |
Unit Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 31-1/2 x 11-1/4 x 21-5/8 [800 x 285 x 550] |
Package Dimensions (W x D x H) | inch x inch x inch [mm x mm x mm] | 37-1/16 x 14-31/32 x 24-13/16 [940 x 380 x 630] |
Unit Weight | lbs [kg] | 65 [29.5] |
Package Weight | lbs [kg] | 77 [32.4] |
ODU Operating Temp. Range (Cooling Intake Air Temp [Max/Min]) | °FDB | 115 / 14 |
ODU Operating Temp. Range (Cooling Thermal Lock-out / Re-start Temperatures) | °FDB | -1 / 3 |
ODU Operating Temp. Range (Heating Intake Air Temp [Max/Min]) | °FDB, °FWB / °FDB, °FWB | 75, 65 / -5, -6 |
ODU Operating Temp. Range (Heating Thermal Lock-out / Re-start Temperatures) | °FDB | -14 / -4 |
Refrigerant Type | - | R454B |
Pre-Charged Refrigerant Amount | lbs, oz | 1, 6 |
Maximum Pre-Charged Piping Length | ft [m] | 25 [7.50] |
Additional Refrigerant Charge Per Additional Piping Length | oz/ft | 0.22 |
Liquid Pipe Size O.D. [Flared] | inch [mm] | 1/4 [6.35] |
Maximum Piping Length | ft [m] | 65 [20] |
Maximum Height Difference | ft [m] | 40 [12] |
Maximum Number of Bends | - | 10 |
Indoor Unit Accessories
- Wired Remote Controllers: Deluxe Wired MA Remote Controller (PAR-42MAAUB), Simple Direct Wired Remote Controller (PAC-SDW01RC-1), Wired Remote Controller (PAC-YT53CRAU-J), Simple MA Remote Controller (PAR-CT01MAU-SB), Touch MA Wired Remote Controller (PAR-CT01MAU-SB)
- Condensate Pumps: Blue Diamond Advanced Mini Condensate Pump (X87-721), Blue Diamond MaxiBlue Advanced Mini Condensate Pump (X87-711), Blue Diamond MegaBlue Advanced Condensate Pump (X87-835), Blue Diamond MicroBlue Mini Condensate Pump (X86-003), Refco Condensate Pump (COMBI, GOBI-II, X86-011), Sauermann Condensate Pump (S130-230)
- Lineset Insulation: 15 ft (MLS143812T-15), 30 ft (MLS143812T-30), 50 ft (MLS143812T-50), 65 ft (MLS143812T-65)
- Filters: Electro Static Anti-allergy Enzyme Filter (MAC-2320FT-E), Microparticle Filter (MAC-EMF515FT-E)
- Power Supplies and Auxiliary Components: Backup Heat Relay Kit Adapter (CN24RELAY-KIT-CM3)
- Control Interface: Airzone Wired Blueface Controller (AZZBSBLUEZEROCN/CB), Airzone Wireless Lite Controller (AZZBSLITERN/B), Airzone Wireless Think Controller (AZZBSTHINKRN/B), IT Extender for kumo station (PAC-WHS01IE-E), kumo station for Comfort app (PAC-WHS01HC-E), M-Net I/O Control Interface (MAC-334IF-E), Procon BACnet/Modbus Interface (PAC-UKPRC001-CN-1), Thermostat Interface (PAC-US445CN-1), Wireless Interface Adapter (PAC-USWHS002-WF-2)
- Wireless Remote Controller: Lockdown Bracket (RCMKP1CB), RedLINK Wireless Remote Controller (MHK2)
- Drain Hose: Flexible Mini-Split Drain Hose (DRX-16)
- Disconnect Switch: 30A600VUL fits 2 X 4 utility box - Black (TAZ-MS303), 30A600VUL fits 2 X 4 utility box - White (TAZ-MS303W)
- Remote Sensor: Remote Temperature Sensor (M21EAA307), Wireless temperature and humidity sensor (PAC-USWHS003-TH-1)
Notes:
- 2Allows IDU Connection to MA Controller: Requires MAC-334IF-E Interface for Deluxe MA, Simple MA, and Touch MA Controllers.
Outdoor Unit Accessories
- Mini-Split Wire: 14 Gauge 4 wire Armored MiniSplit Cable (SW144-250 for 250 ft, SW144-50 for 50 ft), 14 Gauge 4 wire MiniSplit Cable (S144-250 for 250 ft, S144-50 for 50 ft)
- Snow/Rain Diverter: SRD-1
- Air Outlet Guide: MAC-881SG-E
- Drain Socket: MAC-871DS
- Control/Service Tool: M- & P-Series Maintenance Tool Cable Set (M21EC0397), Maintenance Tool Interface (PAC-USCMS-MN-1)
- Stand: 18 Single Fan Stand (QSMS1801M), 24 Single Fan Stand (QSMS2401M)
- Mounting Pad: Condenser Wall Bracket - Stainless Steel Finish (QSWBSS), Condenser Wall Bracket (QSWB2000M-1), Outdoor Unit 3-14 inch Mounting Base Pair - Plastic (DSD-400P), Outdoor Unit Stand 12 High (QSMS1201M), Condensing Unit Mounting Pad 16 x 36 x 3 (ULTRILITE 1)
- Optional Defrost Heater: Base Heater (MAC-650BH-U), Base Heater (MAC-640BH-U)
- Hail Guards: HG-B4
Dimensions and Clearances
Indoor Unit Dimensions (MSZ-HX09NL-U1 / MSZ-HX12NL-U1)
Unit Dimensions: 33 inches (Width) x 9-1/4 inches (Depth) x 11-1/32 inches (Height) [838 mm x 235 mm x 280 mm].
Installation Plate: Features 7/16 x 25/32 inch and 7/16 x 1-1/32 inch oblong holes for mounting.
Piping Connections:
- Liquid Line: Ø1/4 inch (flared connection), with insulation Ø1-5/32 inch.
- Gas Line: Ø3/8 inch (flared connection), with insulation Ø1-5/32 inch.
- Drain Hose: Connected part Ø5/8 inch O.D.
Clearances: Specific clearances are indicated in diagrams for piping and installation, including minimums for left, left rear, or left under piping using a spacer (e.g., MIN 4-29/32 inches).
Outdoor Unit Dimensions (MUZ-HX09NL-U1 / MUZ-HX12NL-U1)
Unit Dimensions: 31-1/2 inches (Width) x 11-1/4 inches (Depth) x 21-5/8 inches (Height) [800 mm x 285 mm x 550 mm].
Required Space:
- 4 inches (100 mm) or more when front and sides of the unit are clear.
- 14 inches (350 mm) or more when the front is clear.
- 8 inches (200 mm) or more when any 2 sides (left, right, rear) of the unit are clear.
Piping Connections:
- Liquid refrigerant pipe joint: Ø1/4 inch (flared).
- Gas refrigerant pipe joint: Ø3/8 inch (flared).
Service Panel: Accessible for maintenance.
Contact and Certifications
Manufacturer: Mitsubishi Electric Trane HVAC US LLC
Address: 1340 Satellite Boulevard Suwanee, GA 30024
Contact: Toll Free: 800-433-4822
Website: https://mitsubishicomfort.com
Certifications:
- AHRI CERTIFIED® (Unitary Small HP, AHRI Standard 210/240)
- ETL LISTED (Intertek)