Mitsubishi MSZ-JX12WL & MUZ-JX12WL System

Mitsubishi MSZ-JX12WL & MUZ-JX12WL: 12,000 BTU/H Ductless Mini Split Heat Pump System

This document provides detailed features, specifications, and accessory information for the Mitsubishi Electric MSZ-JX12WL indoor unit and MUZ-JX12WL outdoor unit, a 12,000 BTU/H ductless mini-split heat pump system.

Indoor Unit Features (MSZ-JX12WL)

  • 115V power supply
  • 12-hour timer
  • Dual Barrier Coating: Reduces contaminant buildup on the heat pump's inner surface for optimal airflow and easier maintenance.
  • Econo Cool: Automatically adjusts airflow based on heat exchanger temperature, slightly increasing the set temperature to save energy while maintaining comfort.
  • Four fan speed options: Low, Medium, High, Super-high.
  • Multiple control options: Includes a back-lit screen hand-held Remote Controller, comfort app, third-party interfaces, and both wired and wireless controllers.
  • Smart Dry Mode: Enhances humidity control by minimizing over-cooling.

Outdoor Unit Features (MUZ-JX12WL)

  • Blue Fin Coating: Anti-corrosion treatment on heat exchanger fins to protect against salt, sulfur, and other airborne contaminants, especially in coastal and industrial areas.
  • INVERTER-driven compressor: Provides precise capacity control to maintain the set temperature.

Specifications

Indoor Unit Specifications

Indoor Unit Performance and Dimensions
Parameter Unit Value
Maximum CapacityBtu/h13,400
Rated CapacityBtu/h12,000
Minimum CapacityBtu/h3,600
Maximum Power Input (Cooling at 95°F)W1,430
Rated Power Input (Cooling at 95°F)W960
Moisture RemovalPints/h2
Sensible Heat Factor-0.82
Power Factor [208V/230V] (Cooling at 95°F)%98/98
Maximum Capacity (Heating at 47°F)Btu/h15,500
Rated Capacity (Heating at 47°F)Btu/h12,200
Minimum Capacity (Heating at 47°F)Btu/h4,500
Maximum Power Input (Heating at 47°F)W2,140
Rated Power Input (Heating at 47°F)W990
Power Factor [208V/230V] (Heating at 47°F)%100/100
Maximum Capacity (Heating at 17°F)Btu/h9,000
Rated Capacity (Heating at 17°F)Btu/h7,800
Maximum Power Input (Heating at 17°F)W1,670
Rated Power Input (Heating at 17°F)W900
Maximum Capacity (Heating at 5°F)Btu/h8,600
Maximum Power Input (Heating at 5°F)W1,400
Maximum Capacity (Heating at -5°F)Btu/h8,300
SEER2-20
EER2-12.5
HSPF2 [IV]-10
COP at 47°F-3.61
COP at 17°F at Maximum Capacity-1.56
COP at 5°F at Maximum Capacity-1.8
COP at -5°F at Maximum Capacity-1.76
ENERGY STAR® Certified-Yes
Voltage, Phase, FrequencyV AC / V AC, Ø, Hz115 / 115, 1, 60
Guaranteed Voltage RangeV AC103-127
Voltage: Indoor - Outdoor, S1-S2V AC115
Voltage: Indoor - Outdoor, S2-S3V DC24
Short-circuit Current Rating [SCCR]kA5
Recommended Fuse/Breaker Size (Outdoor)A20
Recommended Wire Size [Indoor - Outdoor]AWG14
MCAA1.4
Fan Motor OutputW30
Airflow Rate at Cooling, DryCFM168, 243, 333, 468
Airflow Rate at Cooling, WetCFM151, 219, 300, 422
Airflow Rate at Heating, DryCFM173, 239, 343, 395
Sound Pressure Level [Cooling]dB (A)22, 30, 38, 47
Sound Pressure Level [Heating]dB (A)23, 30, 38, 43
Drain Pipe Size O.D.inch [mm]5/8 [15.88]
External Finish Color-Munsell 0.7PB 9.2/0.4
Unit Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]33 x 9-1/4 x 11-1/32 [838 x 235 x 280]
Package Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]36 x 13-1/4 x 11-1/2 [920 x 340 x 300]
Unit Weightlbs [kg]20 [9]
Package Weightlbs [kg]24 [10.50]
Fan Motor Type-DC Motor
IDU Operating Temp. Range (Cooling Intake Air Temp [Max/Min])°FDB, °FWB / °FDB, °FWB90, 73 / 67, 57
IDU Operating Temp. Range (Heating Intake Air Temp [Max/Min])°FDB80 / 70

Outdoor Unit Specifications

Outdoor Unit Performance and Dimensions
Parameter Unit Value
MCAA17
MOCPA29
Fan Motor Full Load AmperageA0.5
Fan Motor OutputW55
Airflow Rate CoolingCFM1,344
Airflow Rate HeatingCFM1,152
Defrost Method-Reverse Cycle
Coating on Heat Exchanger (Bluefin, Sea Coast)-Yes, Yes
Sound Pressure Level, CoolingdB (A)49
Sound Pressure Level, HeatingdB (A)51
Compressor Type-Twin Rotary
Compressor Model-SRB140FQHMC
Compressor Oil [Type // Charge]Type // ozRM68EH // 11.8
External Finish Color-Munsell 3Y 7.8/1.1
Base Pan Heater-Optional
Unit Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]31-1/2 x 11-1/4 x 21/5/8 [800 x 285 x 550]
Package Dimensions (W x D x H)inch x inch x inch [mm x mm x mm]36 x 13-1/4 x 11-1/2 [920 x 340 x 300]
Unit Weightlbs [kg]20 [9]
Package Weightlbs [kg]24 [10.50]
ODU Operating Temp. Range (Cooling Intake Air Temp [Max/Min])°FDB115 / 14
ODU Operating Temp. Range (Cooling Thermal Lock-out / Re-start Temperatures)°FDB-1 / 3
ODU Operating Temp. Range (Heating Intake Air Temp [Max/Min])°FDB, °FWB / °FDB, °FWB75, 65 / -5, -6
ODU Operating Temp. Range (Heating Thermal Lock-out / Re-start Temperatures)°FDB-14 / -4
Refrigerant Type-R454B
Pre-Charged Refrigerant Amountlbs, oz2, 2
Maximum Pre-Charged Piping Lengthft [m]25 [7.50]
Additional Refrigerant Charge Per Additional Piping Lengthoz/ft0.22
Gas Pipe Size O.D. [Flared]inch [mm]3/8 [9.52]
Liquid Pipe Size O.D. [Flared]inch [mm]1/4 [6.35]
Maximum Piping Lengthft [m]65 [20]
Maximum Height Differenceft [m]40 [12]
Maximum Number of Bends-10

Indoor Unit Accessories

Indoor Unit Accessories List
Category Accessory Name Model Number
Wired Remote ControllerDeluxe Wired MA Remote ControllerPAR-42MAAUB
Wired Remote ControllerSimple Direct Wired Remote ControllerPAC-SDW01RC-1
Wired Remote ControllerSimple MA Remote ControllerPAC-YT53CRAU-J
Wired Remote ControllerTouch MA Wired Remote ControllerPAR-CT01MAU-SB
Lineset15 x 1/4 x 15 3/8 Lineset Twin-Tube InsulationMLS143812T-15
Lineset30 x 1/4 x 30 3/8 Lineset Twin-Tube InsulationMLS143812T-30
Lineset50 x 1/4 x 50 3/8 Lineset Twin-Tube InsulationMLS143812T-50
Lineset65 x 1/4 x 65 3/8 Lineset Twin-Tube InsulationMLS143812T-65
CondensateBlue Diamond Advanced Mini Condensate Pump w Reservoir Sensor (208230V recommended)X87-721
CondensateBlue Diamond MaxiBlue Advanced Mini Condensate Pump w Reservoir Sensor (110V up to 48000 BTUH recommended)X87-711
CondensateBlue Diamond MegaBlue Advanced Condensate Pump w Reservoir SensorX87-835
CondensateBlue Diamond MicroBlue Mini Condensate Pump (110/208/230V up to 18000 BTUH)X86-003
CondensateBlue Diamond Sensor Extension Cable 15 FtC13-103
CondensateDrain Pan Level SensorControlSS610E
CondensateRefco Condensate Pump 100-240 VAC up to 120000 BTUHCOMBI
CondensateRefco Condensate Pump 100-240 VACGOBI-II
CondensateREFCO PUMP 100-240 VAC 50/60 HZX86-011
CondensateSauermann Condensate PumpS130-230
Control InterfaceAirzone Wired Blueface Controller BlackAZZBSBLUEZEROCN
Control InterfaceAirzone Wired Blueface Controller WhiteAZZBSBLUEZEROCB
Control InterfaceAirzone Wireless Lite Controller BlackAZZBSLITERN
Control InterfaceAirzone Wireless Lite Controller WhiteAZZBSLITERB
Control InterfaceAirzone Wireless Think Controller BlackAZZBSTHINKRN
Control InterfaceAirzone Wireless Think Controller WhiteAZZBSTHINKRB
Control InterfaceIT Extender for kumo stationPAC-WHS01IE-E
Control Interfacekumo station for the Comfort appPAC-WHS01HC-E
Control InterfaceM-Net I/O Control Interface for M-SeriesMAC-334IF-E
Control InterfaceProcon BACnet and Modbus InterfacePAC-UKPRC001-CN-1
Control InterfaceThermostat Interface for 3rd Party ThermostatsPAC-US445CN-1
Control InterfaceWireless Interface Adapter for the Comfort appPAC-USWHS002-WF-2
FilterElectro Static Anti-allergy Enzyme FilterMAC-2320FT-E
FilterMicroparticle FilterMAC-EMF515FT-E
Disconnect Switch30A600VUL fits 2 X 4 utility box - BlackTAZ-MS303
Disconnect Switch30A600VUL fits 2 X 4 utility box - WhiteTAZ-MS303W
Power Supplies and Auxiliary ComponentsBackup Heat Relay Kit Adapter for CN24 or CN152 ConnectorCN24RELAY-KIT-CM3
Power Supplies and Auxiliary ComponentsLockdown Bracket for Wireless Handheld Remote ControllersRCMKP1CB
Wireless Remote ControllerRedLINK Wireless Remote ControllerMHK2
Remote SensorRemote Temperature Sensor for MFZ MLZ and MSZ modelsM21EAA307
Remote SensorWireless temperature and humidity sensor for the Comfort appPAC-USWHS003-TH-1
Drain HoseFlexible Mini-Split Drain HoseDRX-16

NOTES:
¹Requires MAC-334IF-E Interface to connect MA controller.
²Allows IDU Connection to MA Controller.

Outdoor Unit Accessories

Outdoor Unit Accessories List
Category Accessory Name Model Number
Stand18 Single Fan StandQSMS1801M
Stand24 Single Fan StandQSMS2401M
StandCondenser Wall Bracket - Stainless Steel FinishQSWBSS
StandCondenser Wall BracketQSWB2000M-1
StandOutdoor Unit 3-14 inch Mounting Base Pair - PlasticDSD-400P
StandOutdoor Unit Stand 12 HighQSMS1201M
Mini-Split Wire14 Gauge 4 wire Armored MiniSplit Cable 250 ft rollSW144-250
Mini-Split Wire14 Gauge 4 wire Armored MiniSplit Cable 50 ft rollSW144-50
Mini-Split Wire14 Gauge 4 wire MiniSplit Cable 250 ft rollS144-250
Mini-Split Wire14 Gauge 4 wire MiniSplit Cable 50 ft rollS144-50
Mini-Split WireAir Outlet GuideMAC-881SG-E
Control/Service ToolM- & P-Series Maintenance Tool Cable SetM21EC0397
Control/Service ToolMaintenance Tool InterfacePAC-USCMS-MN-1
Drain SocketDrain SocketMAC-871DS
Hail GuardsHail GuardHG-B4
Mounting PadCondensing Unit Mounting Pad 16 x 36 x 3ULTRILITE1
Snow/Rain DiverterSnowRain DiverterSRD-1

Dimensions

Indoor Unit Dimensions (MSZ-JX12WL)

The indoor unit dimensions are detailed in a diagram. Key dimensions include:

  • Width: 33 inches (838 mm)
  • Depth: 9-1/4 inches (235 mm)
  • Height: 11-1/32 inches (280 mm)
  • Installation plate dimensions and hole sizes are provided.
  • Air inlet and outlet locations are indicated.
  • Piping and drain hose connection points are shown with specific sizes.

(Refer to the original document for a visual representation of these dimensions and clearances.)

Outdoor Unit Dimensions (MUZ-JX12WL)

The outdoor unit dimensions are detailed in diagrams. Key dimensions include:

  • Width: 31-1/2 inches (800 mm)
  • Depth: 11-1/4 inches (285 mm)
  • Height: 21-5/8 inches (550 mm)
  • Required installation clearances are specified: 4 inches (100 mm) or more on front and sides, 8 inches (200 mm) or more on two sides if front/rear are clear, and 14 inches (350 mm) or more on the rear.
  • Drain hole locations are indicated for different models.
  • Refrigerant pipe joint sizes are specified: Liquid refrigerant pipe (flared) ø1/4 inch, Gas refrigerant pipe (flared) ø3/8 inch.

(Refer to the original document for a visual representation of these dimensions and clearances.)

Important Notes

General Notes:

  • Specifications are subject to change without notice.
  • All content is copyright © 2025 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Specific Notes from Specifications:

  • Cooling and Heating performance ratings are based on specific indoor and outdoor temperature and humidity conditions (e.g., Cooling at 95°F, Heating at 47°F, 17°F, 5°F, -5°F).
  • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions.
  • Outdoor unit operating temperature ranges for cooling thermal lock-out/re-start and heating thermal lock-out/re-start are provided.
  • System cuts out in heating mode and automatically restarts at specified temperatures.

PDF preview unavailable. Download the PDF instead.

05c228100539c4cef333d421b0414237 Adobe PDF Library 17.0 Adobe InDesign 19.5 (Windows)

Related Documents

Preview Mitsubishi Electric MSZ-WX18NL & MUZ-WX18NL Inverter Heat Pump System: Features and Specifications
Comprehensive details on the Mitsubishi Electric MSZ-WX18NL wall-mounted indoor unit and MUZ-WX18NL inverter heat pump outdoor unit, including features, technical specifications, dimensions, and accessories.
Preview Mitsubishi MSZ-FX12NL & MUZ-FX12NLHZ: 12,000 BTU Hyper-Heating Inverter Specs
Detailed specifications for the Mitsubishi Electric MSZ-FX12NL indoor unit and MUZ-FX12NLHZ outdoor unit, featuring 12,000 BTU capacity, Hyper-Heating Inverter technology, and advanced features for efficient climate control.
Preview Mitsubishi Electric MSZ-HX12NL & MUZ-HX12NL 12,000 BTU/H Inverter Heat Pump System Specifications
Detailed specifications, features, and dimensions for the Mitsubishi Electric MSZ-HX12NL indoor unit and MUZ-HX12NL outdoor unit, a 12,000 BTU/H inverter heat pump system.
Preview Mitsubishi Electric MSZ-FS15NA & MUZ-FS15NAH 15,000 BTU/H Deluxe Wall-Mounted Indoor Unit & Hyper-Heating Outdoor Unit with Base Pan Heater Specifications
Detailed specifications for the Mitsubishi Electric MSZ-FS15NA indoor unit and MUZ-FS15NAH outdoor unit, a 15,000 BTU/H ductless mini-split heat pump system with Hyper-Heating and a base pan heater. Includes features, efficiency ratings, electrical specifications, and dimensions.
Preview Mitsubishi Electric MSZ-HX09NL & MUZ-HX09NL Air Conditioner Specifications and Features
Detailed specifications, features, and accessories for the Mitsubishi Electric MSZ-HX09NL Wall-Mounted Indoor Unit and MUZ-HX09NL Inverter Heat Pump Outdoor Unit, including performance data, dimensions, and electrical requirements.
Preview Mitsubishi Electric PKA-AK24NL & PUZ-AK24NLHZ: 24,000 BTU/H Hyper Heat Pump System Specifications and Features
Detailed specifications, features, and accessories for the Mitsubishi Electric PKA-AK24NL indoor unit and PUZ-AK24NLHZ outdoor unit, a 24,000 BTU/H Hyper Heat Pump system. Includes performance data, electrical requirements, and installation dimensions.
Preview Mitsubishi Electric M-Series MSZ-GL12NA-U1 & MUZ-GL12NA-U1 Submittal Data Sheet
Comprehensive submittal data for the Mitsubishi Electric M-Series 12,000 BTU/H wall-mounted heat pump system, including specifications, performance data, dimensions, and installation clearances for the MSZ-GL12NA-U1 indoor unit and MUZ-GL12NA-U1 outdoor unit.
Preview Mitsubishi Electric PKA-AK24NL & PUZ-AH24NL HVAC System Specifications and Features
Detailed specifications, features, and dimensions for the Mitsubishi Electric PKA-AK24NL wall-mounted indoor unit and PUZ-AH24NL outdoor heat pump unit. Includes performance data, efficiency ratings, and accessory information.