FactoryTalk View Site Edition Installation Guide

This guide provides essential information for installing and configuring Rockwell Automation's FactoryTalk View Site Edition (SE) software. It covers the entire process from initial setup to advanced deployment and upgrade strategies.

About FactoryTalk View SE

FactoryTalk View Site Edition (SE) is a powerful human-machine interface (HMI) software package designed for developing and running HMI applications across networks. It supports multi-user and multi-server environments, offering a scalable solution for industrial automation.

Key Components and Architecture

A typical FactoryTalk View SE system comprises several key components, including:

  • FactoryTalk View Studio Enterprise: The development environment for creating and testing HMI applications.
  • FactoryTalk View SE Server (HMI Server): Stores HMI project components and provides data to clients.
  • FactoryTalk View SE Client: Allows users to interact with HMI applications at runtime.
  • FactoryTalk View SE Station: A single-computer HMI solution for enterprise-level applications.
  • FactoryTalk Services Platform: Essential services supporting the HMI system, including FactoryTalk Linx for data communication.

The system architecture facilitates distributed operations, enabling seamless communication between servers and clients over Ethernet.

Installation and Configuration

The installation process involves several critical steps, including:

  • Reviewing system and hardware requirements.
  • Performing pre-installation configurations such as disabling automatic Windows updates and configuring network interfaces.
  • Executing the installation steps for the software components.
  • Activating the FactoryTalk View software using provided activation keys.
  • Deploying applications to the network, including moving application files and setting up server properties.

Upgrading and Maintenance

This guide also details procedures for upgrading existing FactoryTalk View SE applications, whether they are non-redundant or redundant network distributed systems. It covers preparing for the upgrade, performing software component upgrades, migrating applications, and testing the updated system.

For support or further information, Rockwell Automation provides resources through their Knowledgebase and customer support channels.

PDF preview unavailable. Download the PDF instead.

viewse-in003 -en-e Rockwell Automation Adobe PDF Library 20.12.73

Related Documents

Preview FactoryTalk Historian SE Installation and Configuration Guide
Comprehensive guide for installing and configuring FactoryTalk Historian SE, a powerful data management solution from Rockwell Automation for collecting, storing, analyzing, and visualizing industrial data.
Preview Rockwell Automation Library of Process Objects: Configuration and Usage Guide
A comprehensive guide to building and utilizing library components within the Rockwell Automation Library of Process Objects. This manual details the customization of HMI templates and the implementation of HMI security, offering step-by-step instructions for plant personnel. It also covers associated productivity tools like the PlantPAx Configuration Tool for HMI alarms.
Preview Rockwell Automation TCP and UDP Port Configuration Quick Reference Guide
A comprehensive guide detailing TCP and UDP port assignments for Rockwell Automation software and hardware products, including communication protocols, product names, and port functions.
Preview FactoryTalk View Machine Edition Installation Guide
This guide provides comprehensive instructions for installing, activating, and uninstalling FactoryTalk View Machine Edition (ME) software. It covers system requirements, software packages, installation procedures, activation management, and troubleshooting.
Preview Rockwell Automation Library of Process Objects: Advanced Analog Input (P_AlnAdv) Reference Manual
This reference manual provides detailed information on the Rockwell Automation Library of Process Objects: Advanced Analog Input (P_AlnAdv) Add-On Instruction. It covers its functional description, capabilities, required files for implementation, and usage guidelines within the PlantPAx system. The document details features such as linear and square root scaling, alarm management, rate of change calculations, and graphical interface elements for monitoring and configuring analog input data.
Preview Rockwell Automation Library of Process Objects: 2-state Valve Statistics (P_ValveStats) Reference Manual
This reference manual details the Rockwell Automation Library of Process Objects 2-state Valve Statistics (P_ValveStats) Add-On Instruction, version 3.5. It covers functional descriptions, input/output parameters, configuration, usage examples, and faceplate details for industrial automation applications.
Preview PanelView Plus 7 Operator Interfaces: Enhanced Performance and Scalability
Explore the features and specifications of Rockwell Automation's PanelView Plus 7 operator interfaces, designed for enhanced performance, scalability, and ease of use in industrial automation. Learn about Standard and Performance models, their capabilities, and applications.
Preview FactoryTalk Batch View Quick Start Guide
A quick start guide for Rockwell Automation's FactoryTalk Batch View software, covering installation, system requirements, client setup, and an overview of its features for batch process control.