The following table has been created to show the communication ports used by individual products. This table does not include any ports necessary for the proper functioning of third party products used in conjunction with Rockwell Automation® products, Microsoft® products, etc.
When using any piece of FactoryTalk® software, it is important to note the reliance of the individual software piece upon the FactoryTalk Services Platform. Thus, when determining which ports to open, include both of the following:
- Redundant modules follow the same TCP / UDP ports as the standard modules.
- Product specific ports
- FactoryTalk Services Platform ports
Port | Type | Protocol | Products | Comments |
---|---|---|---|---|
23 | TCP | Telnet | Trusted, AADvance™™ before release 1.3 | Diagnostic command line interface (see also 55555) |
25 | TCP | SMTP | 1769-L35E, 1769-L32E,1756-ENBT, 1756-EN2T,1756-EWEB,1768-ENBT, 1768-EWEB,1788-ENBT, 1763-L16x, 1766-L32x, FactoryTalk AssetCentre, FactoryTalk Transaction Manager, RSBizWare, RSView Messenger | Outbound email only |
67-68 | UDP | DHCP/ BOOTP | 1756-ΕΝΕΤ, 1756-ENBT,1756-EWEB, 1756-EN2T,1794-AENT,1734-AENT, 1769-L35E, 1769-L32E, 1788-ENBT, 1761-NET-ENI, 1785-LXXE, 1785-ENET, 1747-L55x,1791ES,1763-L16x,1766-L32x, 5820-El, PowerFlex Drives, PowerMonitor 3000, PanelView | Client only |
69 | UDP | TFTP | 5820-ΕΙ | For binary download, used in conjunction with BootP |
80 | TCP | HTTP | 1756-ΕΝΕΤ,1756-ENBT,1756-EWEB, 1794-ΑΕΝΤ,1734-AENT, 1769-L35E, 1769-L32E,1788-ENBT,1761-NET-ENI, 1785-LXXE, 1785-ENET,1747-L55x, 1763-L16x,1766-L32x, PowerFlex Drives, PowerMonitor 3000, PanelView, RSBizWare, RSView32,FactoryTalk View SE, RSViewSE, FactoryTalk VantagePoint, FactoryTalk ViewPoint | FactoryTalk Viewpoint and VantagePoint EMI server can use any other custom assigned port |
123 | UDP | NTP | PowerMonitor 3000, AADvance | Network time protocol |
135 | TCP | RPC/ Endpoint Mapper | FactoryTalk, RSMACC | DCOM endpoint mapper |
161 | UDP | SNMP | 1756-ΕΝΕΤ,1756-ENBT,1794-AENT, 1734-ΑΕΝΤ,1769-L35E, 1769-L32E, 1788-ENBT,1761-NET-ENI, 1785-LXXE, 1785-ΕΝΕΤ,1747-L55x,1766-L32x, 5820-El, PowerFlex Drives, PowerMonitor 3000, PanelView | Master/Slave configuration |
300-400 | UDP | Proprietary | PowerMonitor 3000 | Master/Slave configuration |
400-402 | TCP | RPC | FactoryTalk Transaction Manager, RSSQL, Compression Server, Configuration Server | Transaction Manager, Compression Server, and Configuration Server |
443 | TCP | HTTPS | FactoryTalk ViewPoint | When using web server with secure Certificate |
502 | TCP | ModbusTCP | AADvance, Trusted | Master or slave |
Dynamic (1024-65535+) | TCP | DCOM | FactoryTalk | DCOM dynamic ports |
1089 | TCP/UDP | ff-annunc | Foundation Fieldbus | Foundation Fieldbus |
1090 | TCP/UDP | ff-fms | FF Fieldbus Message Specification | FF Fieldbus Message Specification |
1091 | TCP/UDP | ff-sm | FF System Management | FF System Management |
1132 | TCP | SNCP | AADvance | Safety Network Control Protocol, used by OPC, workbench debugger and binding networks |
1330 | TCP | rnaprpc | FactoryTalk | Object RPC |
1331 | TCP | rnaserv | FactoryTalk | Service control |
1332 | TCP | rnaserverping | FactoryTalk | Server health |
1433 | TCP | FactoryTalk AssetCentre (server), FactoryTalk VantagePoint RSMACC | SQL Server communication (default port) | |
1434 | UDP | FactoryTalk AssetCentre (server), FactoryTalk VantagePoint | Recommended static destination port for MSSQL to minimize the number of ports open on a firewall. See MS Knowledgebase article 287932. | |
1947 | TCP/UDP | SafeNet Sentinel Local License Manager | Windows Service installed by Sentinel USB HASP driver. This service is not required for USB dongle to function. For more information and to disable this service see AID-570831 | |
2000 | TCP | Modbus RTU | AADvance (Slave only), Trusted (Master or slave, used for OPC and SOE) | RTU packaged in serial stream. Other ports may be assigned. |
2010, 2011 | UDP | Discover tool | AADvance | Used to configure systems. The tool sends broadcast to 2010 and systems reply to port 2011 |
2222 | UDP | EtherNET/IP | 1756-ENBT, 1794-AENT,1734-AENT, 1769-L35E, 1769-L32E,1788-ENBT | I/O communications used only by products that support I/O over EtherNet/IP. |
3060 | TCP | rnadirft | FactoryTalk | Directory Server file transfer |
3622 | TCP/UDP | ff-Ir-port | FF LAN Redundancy Port | FF LAN Redundancy Port |
4000 | UDP | Peer to Peer | Trusted | Original simplex protocol |
4120 | TCP | RSBizWare | Production Server | |
4121 | TCP | RPC | RSBizWare | Server Manager |
4122 | TCP | RPC | RSBizWare | PlantMetrics Server |
4123 | TCP | RPC | RSBizWare | Task Manager |
4124 | TCP | RPC | RSBizWare | Scheduler Server |
4125 | TCP | RPC | RSBizWare | Scheduler CTP Server |
5000 | UDP | Peer to Peer | Trusted, AADvance | Enhanced (new) protocol |
5450 | TCP | FactoryTalk Historian Site Edition | PI Network Manager | |
5454 | TCP | FactoryTalk Historian Site Edition | Analysis Framework v1.x | |
5455 | TCP | FactoryTalk Historian Site Edition | Analysis Framework v1.x | |
5456 | TCP | FactoryTalk Historian Site Edition | ACE 2 scheduler | |
5457 | TCP | FactoryTalk Historian Site Edition | Asset Framework Server | |
5458 | TCP | FactoryTalk Historian Site Edition | PI Notifications | |
5459 | TCP | FactoryTalk Historian Site Edition | Asset Framework to OLEDB Enterprise | |
6000 | TCP | Workbench | Trusted | Online debugger |
6543 | TCP | rnaalarming | FactoryTalk | Alarming Server |
7002-7004 | TCP | FactoryTalk AssetCentre (default) | FactoryTalk AssetCentre services | |
7600 | TCP | FactoryTalk | Event Multiplexor | |
7700 | TCP | FactoryTalk | Event Server | |
7710 | TCP | FactoryTalk | Directory Server | |
7720 | TCP | RSView SE | HMI Server | |
7721 | TCP | FactoryTalk View SE, RSView SE | Server Framework | |
7722 | TCP | RSView SE, FactoryTalk View SE | HMI Activation | |
7723 | TCP | RSView SE, FactoryTalk View SE | Historical Data Log Reader | |
8080 | TCP | HTTP | RSBizWare | Production Server, reports Server Manager |
8081 | TCP | HTTP | RSBizWare | Server Manager |
8083 | TCP | HTTP | CTP Server | CTP Server |
10001 - 10006 | TCP | Serial data | AADvance | Transparent Communication Interface, where an Ethernet host can talk through AADvance to a serial port. |
27000 - 27009 | TCP/IP | FactoryTalk Activation Server; FactoryTalk Activation Manager | See AID-35717 and AID-184922 for more Applications required to run FLEXSVR.EXE and LMGRD.EXE | |
44818 | TCP/UDP | EtherNET/IP | 1756-ΕΝΕΤ,1756-ENBT,1756-EWEB, 1794-ΑΕΝΤ,1734-AENT,1769-L35E, 1769-L32E,1788-ENBT,1761-NET-ENI, 1785-LXXE, 1785-ENET,1747-L55x, 1763-L16x,1766-L32x, PowerMonitor 3000, PanelView, RSLinx Classic, RSLinx Enterprise, INTERCHANGE (rsicd) | Messaging, data transfer, upload/download, peer messaging, etc. Used largely by RSLinx. |
49281 | TCP | TCP/IP | FactoryTalk Live Data, FactoryTalk View SE HMI Tag server | HMI Tag Server |
55555 | TCP | Telnet | AADvance from release 1.3 | Diagnostic command line interface |
60093 | TCP | TCP/IP | FactoryTalk Diagnostics | FactoryTalk Diagnostics |
65207 | TCP | TCP/IP | FactoryTalk VantagePoint | Incuity Server Advertiser |