CF4680 2D Imager Module

For Customer-Facing Designs

Quick Start Guide

Document Revision: CF4680-EN-QS Rev A, Date: 5/21

What is the CF4680 2D Imager Module?

The CF4680 is a 2D imager module designed to be integrated into fixed mount enclosures, such as a self-service kiosk. It includes:

Required Accessories

Additional Documentation

The following documents are available for the CF4680:

These documents are available from your local Honeywell OEM representative.

CF4680 Front View

Diagram showing the front of the CF4680 module. Key features labeled are the 'Exit window' and 'Mounting holes (x4)'.

CF4680 Back View

Diagram showing the back of the CF4680 module. Components labeled include: 'Movement detector', 'Ribbon cable sensor to PCB', 'Scan engine', 'Ribbon cable engine to PCB', 'USB-B connector', 'User feedback pins', and 'Distance selection switch'.

PCB View

Top view of the main PCB. Labeled components include: 'Flex connector to movement detector', 'USB-B connector', 'User feedback pins', and 'Distance selection switch'.
Bottom view of the PCB, showing component placement. Labeled component: 'Flex connector to scan engine'.

Connecting the CF4680 to a Host

By default, the CF4680 is in USB PC Keyboard interface.

  1. Connect a standard USB cable (standard USB-A to USB-B) to the CF4680 and to the USB port on the host.
  2. Power-up the host.
  3. Verify that the CF4680 is on by presenting a bar code in front of the scan window. The white LED should turn on and read the bar code.

Note: The CF4680 does not beep to indicate a good read unless this has been setup by the user with the user feedback pins. See the CF4680 Installation Guide for more details (available from your local Honeywell OEM representative).

Distance Selection Switch

Use this switch to select the range to be used to detect an object and trigger the scan engine. The distance is measured from the outside of the exit window.

Diagram showing the PCB with the distance selection switch labeled 'Position'.

Configuration

You can configure your scanner two ways:

Configuration Bar Codes

Scan configuration bar codes to set up your scanner. All available configuration bar codes are available in the N4680/CF4680 User Guide. Contact your local Honeywell OEM representative for more information.

EZConfig for Scanning Tool

Use the EZConfig for Scanning tool to configure your scanner Online:

  1. Go to the Honeywell website: https://hsmftp.honeywell.com.
  2. Register (if you haven't already), then login.
  3. Browse to Software > Barcode Scanners > Software > Tools and Utilities > EZConfig for Scanning > Current and download the tool.
  4. Open EZConfig to configure your scanner.

Basic Setup

Here are some basic menu bar codes that may be useful for testing. For more setup options see the N4680/CF4680 User Guide (available from your local Honeywell OEM representative).

Note: The * symbol indicates the default value.

Interface

For USB serial interface, you must install the USB driver before connecting your scanner. Contact your local Honeywell OEM representative to get the latest USB driver.

USB Serial Interface

[Barcode: TERMID130]

USB PC Keyboard *

[Barcode: TERMID124]

Keyboard Country Layout

The default keyboard is United States.

French

[Barcode: KBDCTY3]

German

[Barcode: KBDCTY4]

Italian

[Barcode: KBDCTY5]

All Symbologies

All Symbologies On

[Barcode: ALLENA1]

All Symbologies Off

[Barcode: ALLENAD]

LED Illumination

Use this setting to change the LED illumination brightness.

Reset Factory Defaults

The following bar code resets factory defaults.

[Barcode: DEFALT]

Mechanical Dimensions

Side view diagram showing mechanical dimensions. Key dimensions indicated are: 90.59 (92.0 MAX), 75.07±0.2, 3±0.15, and 1.5±0.2.
Top view diagram showing mechanical dimensions and mounting hole details. Key dimensions indicated are: 105±0.2, 73±0.25, 14±0.2, 45±0.2, 73±0.2, 8±0.15, 5.3±0.15, 61±0.25, and 88.9±0.2. A section view (A-A) details the 'Mounting hole recess' with a dimension of 1±0.1.

User Feedback Pins

User feedback pins give you access to the trigger, beeper and good read lines on the scan engine. See the CF4680 Installation Guide for details on these pins (available from your local Honeywell OEM representative).

Exit Window

The exit window is made of chemically strengthened glass and is scratch resistant. To clean the window, use one of the following:

Note: For best scanner and movement detector performance, do not cover the existing exit window with another window or use a different exit window.

Customer Support and Technical Assistance

For customer support, contact your local Honeywell Sales Representative or fill out the support form at sps.honeywell.com/us/en/contact-us.

Limited Warranty

For warranty information, go to sps.honeywell.com/us/en/support/productivity/warranties.

Patents

For patent information, see sps.honeywell.com/us/en/support/patents.

Disclaimer

Honeywell International Inc. and its affiliates, subsidiaries, and other entities forming part of Honeywell group (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.

Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship during the applicable warranty period. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items that Honeywell, in its sole discretion, finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While Honeywell may provide application assistance personally, through our literature and the Honeywell web site, it is buyer's sole responsibility to determine the suitability of the product in the application. Specifications may change

without notice. The information we supply is believed to be accurate and reliable as of this writing. However, Honeywell assumes no responsibility for its use.

This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII.

Copyright © 2021 Honeywell International Inc. All rights reserved.

Web Address: sps.honeywell.com/us/en/products/sensing-and-iot

Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners.

Models: CF4680, 2D Imager Module, CF4680 2D Imager Module

File Info : application/pdf, 16 Pages, 500.41KB

PDF preview unavailable. Download the PDF instead.

sps-ast-cf4680-imager-module-quick-start-guide-en ?download=false

References

Acrobat Distiller 21.0 (Windows)

Related Documents

Preview Honeywell CM4680 2D Imager Module: Quick Start Guide
Get started quickly with the Honeywell CM4680 2D Imager Module. This guide covers essential setup, connection steps, configuration options, technical specifications, and mounting details for the CM4680 imager.
Preview Honeywell CM4680 2D Imager Module Quick Start Guide
A quick start guide for the Honeywell CM4680 2D Imager Module, covering its features, required accessories, setup, configuration, and technical specifications.
Preview Honeywell CM4680 2D Imager Module Quick Start Guide
A quick start guide for the Honeywell CM4680 2D Imager Module, covering setup, configuration, and technical specifications.
Preview Honeywell Xenon XP 1950h Healthcare 2D Barcode Scanner Quick Start Guide
Get started quickly with the Honeywell Xenon XP 1950h healthcare barcode scanner. This guide covers essential setup, connection methods (USB, Keyboard Wedge, RS232), reading tips, and configuration options for seamless integration.
Preview Honeywell HH490 Handheld 2D Area-Imaging Scanner Datasheet
Detailed specifications and features for the Honeywell HH490 handheld 2D area-imaging scanner. Learn about its performance, environmental specs, and decode capabilities for commercial applications.
Preview Honeywell Voyager XP 1470g Series Corded Area-Imaging Scanner Quick Start Guide
A quick start guide for the Honeywell Voyager XP 1470g Series Corded Area-Imaging Scanner, covering setup, connection, reading techniques, and configuration.
Preview Honeywell N360X Series: Compact 2D Barcode Scan Engine Datasheet
Detailed specifications and features of the Honeywell N360X Series compact, undecoded 2D barcode scan engine, designed for mobile devices. Includes information on performance, dimensions, electrical and environmental characteristics, and supported symbologies.
Preview Honeywell Voyager XP 1470g Series Quick Start Guide - Barcode Scanner Setup
Concise guide to setting up and connecting the Honeywell Voyager XP 1470g Series corded area-imaging barcode scanner, including connection types, reading techniques, and basic configuration.