AstralPool E Series Saltwater Chlorinator

Installation Manual

WARNING

FOR YOUR SAFETY - This product must be installed and serviced by a trained Swimming Pool Technician in accordance with the latest applicable version of AS/NZS 3000, along with any other applicable local and national installation codes/standards, and any other local applicable regulations. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty.

Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death.

Equipment Information Record

Record your equipment details here for quick reference:

DATE OF INSTALLATION: ________________________________

INSTALLER INFORMATION: ________________________________

INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER): ________________________________

PUMP MODEL: ________________________________

HORSEPOWER: ________________________________

FILTER MODEL: ________________________________

CONTROL PANEL MODEL: ________________________________

SERIAL NUMBER: ________________________________

NOTES: ________________________________

Section 1. Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS

All electrical work must be performed by a qualified installer and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:

▲ WARNING

The E Series Saltwater Chlorinator power supply has an IP23 rating, meaning it is suitable for installation outdoors. For safe operation the power supply must be installed in the correct orientation, with the cables leaving from the bottom of the device. If installing the power supply near the pool or spa water, you must ensure that the rules of AS3136 are followed at all times. AstralPool® strongly recommends that installation be performed by a registered pool builder, electrician or other suitably qualified person.

▲ WARNING

Risk of electric shock - Install the controller at least 3.5 metres from the inside wall of the pool and/or hot tub using non-metallic plumbing.

▲ WARNING

If the supply cord is damaged, it must only be replaced by AstralPool, its service agent or a similarly qualified person, in order to avoid a hazard.

The transformer is not intended for series/parallel connection.

Never connect more than one light to a single power supply outlet. Each outlet on the power supply must go to one and one only - underwater light.

SAVE THESE INSTRUCTIONS

Section 2. System Overview

2.1 Contents

Before starting, check that you have the correct parts as indicated in Table 1. If any parts are missing or incorrect, please call your local distributor or technical support at 1300 186 875 for assistance.

2.2 Salt Chlorinator System

The E25/E35 Saltwater Chlorinator system includes:

Diagram Description (Figure 1): The controller unit is shown from the front and side, with dimensions indicated: 32.3 cm height, 22.54 cm width, 13.15 cm depth.

Diagram Description (Figure 2): The electrolytic cell unit is shown with dimensions indicated: 32 cm length, 21.5 cm width, 11 cm height, 15.5 cm depth, 11.5 cm width, 21.5 cm width.

2.3 Specifications

2.3.1 Salt Chlorinator System

E 25 E 35
Nominal chlorine production 25 g/h 35 g/h
Nominal output amps 4.4 A 5.8 A
Required salt level 6000ppm
Power supply voltage 230 - 240 VAC
Protection index IP23
Flow through the cell Min. 80 Lpm
Operating water temperature 10°C - 40°C

2.4 Dimensions

2.4.1 Controller

Diagram Description: Shows front and side views of the controller with dimensions: 32.3 cm (height), 22.54 cm (width), 13.15 cm (depth).

2.4.2 Cell

Diagram Description: Shows the electrolytic cell with dimensions: 32 cm (length), 21.5 cm (width), 11 cm (height), 15.5 cm (depth), 11.5 cm (width), 21.5 cm (width).

2.5 Materials and Tools

2.5.1 Controller

Tools Needed for Installation:

2.5.2 Cell

Tools Needed for Installation:

Section 3. Plumbing

Diagram Description (Figure 3): Illustrates a typical pool plumbing setup showing the Controller, Heater, Filter, Pump, Pool/Spa 3 Way Valve, Check Valve, Cell, Pool Return, and Spa Return. Arrows indicate the direction of flow.

The cell must be plumbed in a position that is accessible for maintenance and within 1.5 meters of the controller. The cell should be the last piece of equipment in the circulation system. The cell must be installed horizontally, level and with correct flow orientation.

  1. If you intend to plumb the cell on a bypass, the bypass must be equipped with Isolation valves.
  2. Plumb the cell inlet and outlet on vertical lengths of 50 mm PVC pipe (if using 40mm pipe, use the provided 40mm reducers). The cell inlet and outlet ports are 11.5 cm apart. The inlet of the cell is on the side closest to the electrical lead.
  3. Put the lock nuts onto the inlet and outlet pipes in the correct orientation.
  4. Glue the unions directly onto the pipes.
  5. Ensure the o-rings are seated properly on the unions.
  6. Secure the cell to the plumbing by tightening the unions hand tight. DO NOT OVERTIGHTEN.
  7. Double check cell orientation. The cell inlet is closest to the cell electrical lead.

WARNING

Diagram Description (Figure 4): Shows the Cell Plumbing Assembly, including the Cell, Adapter O-ring, Unions, and Lock Nuts, illustrating how they connect.

Section 4. Install Controller

The controller should be located at or near the equipment pad, at least 3.5 metres or more away from the inside wall of the pool/spa, 1.5 metres off the ground, and within 1.5 meters of the cell. All national, state, and local codes are applicable.

4.1 Mount the Bracket

  1. Determine the controller location.
  2. Use the enclosed bracket to mark the mounting surface through the screw holes.
  3. Drill surface with 7 mm bit.
  4. Install the included wall anchors.
  5. Hang bracket using the included screws.
  6. Hang the controller on the wall bracket and slide down to secure in place.

Diagram Description (Figure 5): Illustrates the process of mounting the controller bracket to a wall and then hanging the controller onto the bracket.

4.2 Electrical Connections

WARNING

FOR YOUR SAFETY: This product must be serviced by a professional pool/spa service technician as described on the front cover of this manual. The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death. Improper installation and/or operation will void the warranty.

The controller must be permanently powered by connection to a 30 mA residential circuit breaker. A non-replaceable backup power source is incorporated to maintain time-setting memory in the event of a short, infrequent power interruption.

4.2.1 Controller and Chlorinator Cell Wiring

  1. Connect the Chlorinator Cell Cable to the appropriate ports on the cell.
  2. Connect the E25/E35 Controller to the power source.

Diagram Description (Figure 6): Shows the Chlorinator Cell Cable Connections, illustrating how the Power Cord and Chlorinator Cell Cable connect to the controller and the cell, with an arrow indicating connection "To Power Source".

Section 5. Prepare and Balance the Pool

5.1 Water Chemistry Table

Test and maintain correct water balance throughout the season, according to the table.

Free Chlorine pH Total Alkalinity (ppm) Calcium Hardness (ppm) Cyanuric Acid (ppm) Salt Level (ppm) Metal
Australian Standard 1 - 3 7.2 - 7.8 60 - 200 100 - 400 up to 50 4000 - 7000 x
Ideal range 1 - 3 7.4 80 - 140 90 - 300 up to 50 4000 at 27°C < 0.10 ppm
To Increase Add chlorine or increase equipment output Add buffer or soda ash (sodium carbonate) Add sodium bicarbonate Add calcium chloride Add cyanuric acid Add salt or minerals ** x
To Decrease Add muriatic acid Add muriatic acid or dry acid Partially drain and refill pool* Partially drain and refill pool* Partially drain and refill pool* Use 'Metal Remover'
In Season Testing Frequency Weekly Weekly Weekly Weekly Weekly Monthly Monthly

NOTE: Test all equipment sensors quarterly.

* Fill pool with water from the mains water supply. Do not use rain water or well water.

** Do not add salt directly into the skimmer. Do not initiate electrolysis until salt has fully dissolved.

*** Reading is True Calcium Hardness, not Total Hardness.

Section 6. Operation

6.1 User Interface Overview

Diagram Description (Figure 7): Shows the controller interface with buttons labeled ENTER, MENU, AUTO, UP, DOWN. Labels indicate functions: "User Menu", "Enter the highlighted selection", "Browse current menu; Increase or decrease a setting", and "Auto - Running/Stopped, Manual - Running, Manual - Stopped".

6.2 Initial Start-Up

CAUTION

To avoid risk of serious damage to the equipment, ensure that all salt added to the pool has completely dissolved before activating the chlorination function of your system.

The following settings must be configured at the initial start-up of the device. Settings can be changed or updated at a later time using the general menu, details can be found in Section 7.

Output can be set between levels 1 to 8 (P1 to P8), this is controlled in increments from the "main screen" by pressing UP or DOWN. The set value is valid until the next modification.

6.2.1 System Power

Press AUTO to cycle between:

Auto - Running indicates that the chlorinator is running within a timer period.

Auto – Stopped indicates that the chlorinator is outside of a timer period.

6.2.2 Set Clock

  1. Press MENU and screen should display CLK. Press ENTER.
  2. Press ENTER and the hour digit will flash. Use UP or DOWN to adjust.
  3. Press ENTER to change to minutes and set. Use UP or DOWN to adjust.
  4. Press ENTER and select AM or PM. Use UP or DOWN to adjust.
  5. Press MENU to save.

Section 7. Installing Equipment

7.1 Programming/Timers

The controller has an internal operating timer that is used to define the length of time for the filter pump to operate during two separate time periods each day. In order to complete the timer program, it is necessary to enter and validate both ON and OFF times. If no timer is set, the filtration and / or chlorination will run continuously.

The filtration operating times must be sufficient to correctly treat the water.

Example - single speed pump:

Example - variable speed pump (when running at lower speeds):

Filter Pump Programming

  1. Press MENU.
  2. Press the MENU again and screen should display TMR. Press ENTER.
  3. Use UP or DOWN to adjust start time for TIMER1. Press ENTER.
  4. Use UP or DOWN to adjust the stop time for TIMER 1. Press ENTER.
  5. Repeat for TIMER 2.

7.1.1 User Operation Modes

The user mode buttons enable you to select and to automatically or manually control the chlorinator/pump. Functions are as follows:

Maximum efficiency will be achieved from your chlorinator at the following levels:

Section 8. Inspecting and Cleaning the Electrode

In areas that experience calcium hardness the cell electrode will benefit from cleaning.

  1. Switch off the filter pump and chlorine generator, close necessary valves and unplug the cell terminal cap.
  2. Unscrew the retaining ring and remove the electrode. If calcium buildup is present, immerse the electrode in cell cleaning solution without immersing the terminals.
  3. We recommend using Purex Salt Cell Cleaner to clean the electrode. However, you can mix your own by carefully adding one (1) part of Hydrochloric (Muriatic) acid to ten (10) parts water. Stronger solutions will shorten terminal life.
  4. Allow the cleaning solution to dissolve the calcium deposits for about 10 minutes.

NOTE: Dispose of the cleaning solution at an approved Council Depot and never into storm water or sewage drains.

  1. Rinse the electrode in clean water and re-fit the electrode in the cell housing.
  2. Replace the cell head and plug assembly.
  3. Reset valves and switches.
  4. Turn pump and controller on.
  5. Confirm chlorine output and settings on the power pack. Timer programs will be automatically retained.

Diagram Description (Figure 8): Shows the cell components being disassembled, illustrating how to open the cell for inspection and cleaning.

Section 9. Winterizing

The chlorinator has a protective system which will limit sanitizer production during unfavorable operating conditions, such as cold water or lack of salt. Active winterizing leaves the filter pump and chlorinator running during the winter. This is safe for temperatures above 10°C. If temperatures drop below 10°C, the chlorination cell needs to be deactivated.

Passive winterization calls for the pool to be shut down. Water levels will need to be lowered and the piping will need to be drained. The cell electrode can be left in place with isolation valves open.

9.1 Reopening the Pool

Required actions:

  1. Adjust the water level (too much or too little)
  2. Check the water parameters: TAC/TH/pH/Salinity/Chlorine/Stabilizing Agent/ Copper/Metals.
  3. Adjust the parameters to obtain a balanced, healthy pool, see Section 5.
  4. Check the condition of the equipment (pump, filter, chlorinator, electrolytic cell).
  5. Where necessary, check the sensors, clean if needed and re-calibrate.
  6. Once the salt level has reached the required level of 6000ppm and has dissolved in the water, restart the salt chlorinator.

Section 10. General Maintenance

If the supply cord is damaged, it must be replaced by AstralPool, its service agent or a similarly qualified person in order to avoid a hazard.

WARNING

Operating the chlorinator with less than 3000 ppm of dissolved salt in the water may cause damage to the cell and will void the warranty. Never start the chlorinator, until the correct quantity of salt has been added and dissolved in your pool water.

10.1 Cell Maintenance

Your E25/E35 Saltwater Chlorinator has an automatic cleaning feature, that under normal conditions, will keep the cell plates clear of deposits of salt and calcium. The cell has a negative charge sensor that monitors the flow and salt levels of the water. This sensor is designed to be fail safe. As it is negative charge deposits of calcium or other debris that may be deposited on it, causing an indication of low salt or no flow condition.

Should a low salt condition be indicated, have your salt level checked at your local pool shop. If the low salt condition persists, or a no flow condition is indicated when the supply pump is operating, you may need to manually clean your E25/E35 Saltwater Chlorinator Cell. See Section 9 for cleaning instructions.

10.2 Maintenance Schedule

The E25/E35 Saltwater Chlorinator has high velocity water with chemicals in it. Some of these parts will wear in the normal course of use and require regular checks and maintenance. Performing these checks and maintenance will identify parts that have worn and require repair/ replacement before further serious damage is sustained. A small amount of regular care and attention to your pool equipment will help ensure long life and trouble free performance.

To protect against extremes of temperature, your unit is vented to allow the electronics to cool. Ants and some insects are often attracted to the warmer, dry environment inside the enclosure. We recommend that, with power turned off, you spray a surface insecticide on the surfaces surrounding the control to prevent ant and insect ingress. Repeat every three months or as necessary.

Note: Regular maintenance is important to ensure long life and trouble free performance of your pool equipment. If unable to perform the maintenance yourself, contact your local pool professional to request assistance with the maintenance.

Timing Maintenance Check Service Action If Required
Weekly or sooner Check Cell for calcium buildup
Check water chemistry
Soak electrode in mixture of 10 parts water to 1 part acid. Use a soft brush only if required.
Balance pH in pool and adjust output of unit to ensure satisfactory production of chlorine.
Every Three Months Check cable connections to Cell
Check Cell connections for leaks
Ensure no water contact is occurring with pins.
Isolate Pump, turn power off, clean and grease O rings or replace if necessary
Every Six Months Check for insects/ants
Check chlorine levels and pump operating hours
Prevent insect ingress to controller
Spray a surface insecticide on the surfaces around the unit to prevent ant and insect ingress
Adjust timer and output depending on demand for current season.
Turn controller off, use an insect spray and spray onto walls around controller. Do not spray directly into unit.

Section 11. Troubleshooting

When there is an error condition, “ERROR" flashes on the display along with the error code.

Fault Indication Possible Cause Solution
NO FLOW (NO F) Pump turned off/disconnected or valves closed
Blue wire disconnected from cell
Ensure valves/pump ON
Connect BLUE sense wire to cell
LOW SALT (LO S) Salt level in pool has dropped too low
Pool water temperature is low
Take sample of water to retailer and check salt level - add salt as recommended.
Add salt and turn chlorinator output down until the water is warmer.
Display Blank Cell has calcified
Cell has failed
Clean the cell.
Call for service
Low/No Chlorine in pool No power to controller
Fuse blown
Cables not connected to cell
Timer period too short
Chlorine output level too low
Filter needs backwashing
pH too high
Pool stabiliser (cyanuric acid) too low
Salt level too low
Plug in controller and ensure main power available
Have a service technician replace fuse (2A slow blow)
Connect cables
Increase timer period (particularly during summer)
Increase chlorine output
Backwash filter
Balance pH level to 7.4 - 7.6
Increase stabiliser between 30 - 60 ppm.
Increase salt to above 6000 ppm
Clock loses time when main power is removed Clock power backup failed Call a technician
Timer is set to OFF in the TMR menu The timer has been turned off Use AUTO to turn the timer back on. Adjust timer start and stop times to suit.

NOTES

Models: E Series, E25, E35, Saltwater Chlorinator

File Info : application/pdf, 16 Pages, 3.16MB

PDF preview unavailable. Download the PDF instead.

References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Windows)

Related Documents

Preview AstralPool E25 & E35 Salt Chlorinator Installation and Operating Instructions
Comprehensive guide for installing and operating the AstralPool E25 & E35 Salt Chlorinator, covering setup, programming, maintenance, and troubleshooting.
Preview Astralpool Rousillon Automatic Pool Cover Installation and Maintenance Manual
A comprehensive guide for the installation and maintenance of the Astralpool Rousillon automatic pool cover, detailing components, civil engineering requirements, assembly steps, electrical installation, and safety features.
Preview AstralPool Viron EQ Salt Chlorinator: Installation and Operating Instructions
Comprehensive guide for installing, operating, and maintaining the AstralPool Viron EQ Salt Chlorinator with Bluetooth. Covers setup, pool chemistry, Ai Mode, and troubleshooting for optimal pool sanitization.
Preview Astralpool Adjustable Bottom Nozzle Installation and Maintenance Manual
Comprehensive guide for installing and maintaining the Astralpool Adjustable Bottom Nozzle, covering product features, step-by-step installation, assembly, start-up, and technical specifications for optimal swimming pool cleaning.
Preview AstralPool Classic Plus Multiport Valve: Installation, Maintenance, and Troubleshooting Guide
Detailed guide for the AstralPool Classic Plus multiport valve (model 73950-1000). Covers valve operations, step-by-step installation, essential maintenance procedures, a complete parts list, and common troubleshooting solutions for swimming pool filter systems.
Preview AstralPool UV Disinfection System Installation Manual
Comprehensive installation manual for AstralPool UV Disinfection Systems (models 11404 and 11405), detailing safety, product information, installation, maintenance, troubleshooting, and warranty procedures.
Preview Astralpool Polyester Pool Installation and Maintenance Manual
This manual provides detailed instructions for the installation and maintenance of Astralpool polyester pools. It covers various models and includes diagrams and specifications for proper setup and upkeep.
Preview Astralpool Algicide Extra: Pool Algae Prevention and Water Treatment
Astralpool Algicide Extra is a concentrated microbicide for effective algae prevention and water clearing in swimming pools. Learn about its properties, characteristics, usage instructions, and dosage for optimal pool maintenance.