Features
- Certified to IEC 62368-1 & CB 60950-1
- Meets USA EISA 2007 requirements
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile design
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- Includes PFC (Power Factor Correction) Circuit
Safety Standard Approvals
The adapter is approved by various safety and regulatory bodies, including:
[CULUS Listed for I.T.E. Power Supply E190414], [TÜVRheinland Certified], [CE Mark], [FCC Tested to Comply With FCC Standards], [CCC Mark for Home or Office Use]
Description
This product is a 150-watt AC to DC adapter designed for use in IPC systems, embedded systems, printers, monitors, POS systems, and PoE applications requiring high wattage. It operates with an input voltage range of 90 to 264 VAC. The unit meets CISPR32, EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, making it suitable for Information Technology Equipment (ITE) applications.
Input Specifications
Parameter | Value |
---|---|
Input Voltage | 90-264 VAC |
Input Frequency | 47-63 Hz |
Input Current | ≤ 1.2A at 100Vac, 240Vac / full load |
No Load Power Consumption | ≤ 0.5W at 115Vac, 230Vac |
Touch Current | ≤ 0.25mA at 264Vac / 50Hz |
Output Specifications
Parameter | Value |
---|---|
Output Voltage/Current | See rating chart |
Total Output Power | 150W |
Protection Features
Over Voltage Protection: The adapter will shut down if the output terminal experiences over-voltage due to an internal fault. The output trip voltage will not exceed 29 volts. Normal operation resumes after AC reset.
Short Circuit & Over Current Protection: In case of an internal fault or an external fault causing overload or short circuit at the output, the power supply will shut down and enter an auto-recovery mode.
Over Temperature Protection: The power supply will shut down if abnormal thermal rise occurs. Normal operation resumes after AC reset.
Brown-out Protection: Set to trigger at 60Vac~70Vac.
Environment Specifications
Parameter | Value |
---|---|
Working Temperature | 0~70°C (derating required above 40°C) |
Storage Temperature | -20~+80°C |
Working Humidity | 20~80% RH non-condensing |
Storage Humidity | 10~90% RH non-condensing |
Performance Characteristics
Parameter | Value |
---|---|
Power Factor | ≥ 0.9 at 115Vac, 230Vac / full load |
Efficiency | See rating chart |
Harmonic Reduction | Provisions for harmonic reduction per EN 61000-3-2 must be present. |
Power Turn-on Time | Output voltage shall remain regulation <3 Sec. at 100Vac / full load. |
Hold-up Time | Output voltage shall remain regulation ≥10ms at 100Vac or 240Vac / full load. |
Inrush Current | Shall be less than the rating of adapter critical components (rectifiers, fuse surge, current limiting device) at 100Vac, 240Vac / full load. |
Operating Altitude | 5000 meters above sea level. |
Withstand Voltage | 4242V DC between AC input and secondary applied DC for 1 minute. Cut-off current shall be less than 10mA. |
MTBF | ≥ 300,000 hours at 100Vac, 240Vac / full load, 25°C, standard SR332. |
EMC Performance |
|
Power De-rating | Applies to 100Vac or 240Vac input. At 0°C to 40°C: 100% load. At 50°C: 85% load. At 60°C: 70% load. At 70°C: 55% load. (Load percentage shall be less than the rating of adapter critical components, following FSP specification). |
Derating Curves
Input Voltage Derating Curve: This curve illustrates that the output power percentage remains at 100% for input voltages from 90 VAC up to approximately 240 VAC. Beyond 240 VAC, the output power percentage begins to decrease.
Output Power Derating Curve: This curve shows that the maximum load percentage is 100% up to an ambient temperature of 40°C. As the temperature increases from 40°C to 70°C, the maximum load percentage is progressively derated.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5 Tier 2) | Over Voltage Protection |
---|---|---|---|---|---|---|
FSP150-AJBU3 | 19.5V | 7.70A | C6 | ≥88% | ≥88% | 29 Volts |
FSP180-AJBU3 | 19.5V | 9.23A | C6 | ≥89% | ≥89% |
Mechanical & AC Connector Specifications
The adapter has the following approximate dimensions:
- Length: 150 ± 50 mm
- Width: 64.5 ± 0.5 mm
- Height: 23.0 ± 0.5 mm
The AC input connector is a C6 type. The DC output connector features a central pin with a diameter of 2.5+0.1mm, surrounded by an outer contact with a diameter of 5.5±0.05mm. The overall connector housing dimensions are approximately 12.5±0.3mm.