Flash Series DJ LED PAR 64 18x12 RGBWA+UV FLAT

User Manual

INTRODUCTION

THANK YOU FOR PURCHASING LED PAR 64. FOR SAFETY REASONS AND TO ENSURE THE TROUBLE-FREE OPERATION, CAREFULLY READ THE INSTRUCTIONS.

SAFETY INFORMATION

Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.

Unpack and check carefully there is no transportation damage before using the fixture.

Before operating, ensure that the voltage and frequency of power supply match the power requirements of the fixture.

It's important to ground the yellow/green conductor to earth in order to avoid electric shock.

Disconnect main power before servicing and maintenance.

Use safety chain when fixes this fixture. Don't handle the fixture by taking its head only, but always by taking its base.

Maximum ambient temperature is: 40°C. Don't operate it where the temperature is higher than this.

In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself.

Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.

Do not connect the device to any dimmer pack.

Do not touch any wire during operation and there might be a hazard of electric shock.

To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain or moisture.

The housing must be replaced if they are visibly damaged.

Do not look directly at the light spot while the fixture is on.

WARNING! Use clamp to rig the fixture.

WARNING! When clamping the fixture to a truss or other structure at any other angle than with the yoke hanging vertically downwards, use two clamps of half-coupler type. Do not use any type of clamp that does not completely encircle the structure when fastened.

WARNING! Position or shade the bar so that the front lens will not be exposed to sunlight or any other strong light source from any angle - even for a few seconds. The LED PAR lens can focus the sun's rays, creating a potential fire hazard and causing damage. [See Figure 1]

IMPORTANT! Do not point strong light output from other fixtures at the LED PAR, as intense illumination can damage the display.

Figure 1 illustrates how sunlight focused by the LED PAR lens can cause a fire hazard.

PRODUCT INFORMATION

Light Source: 18×12W RGBWA+UV LED's
Power consumption: 120W
Power supply voltage: 100-240 V, 50 / 60 Hz AC
LED macro colors
Operating modes: DMX512, Manual, Auto, Sound-controlled, Master/Slave, Sound active, DMX channel mode
DMX Channels: 6 / 10 A / 10 B
IP Rating: IP20
Housing made: Aluminium
Cooling: Active
AC IN/OUT: PowerCon
DMX Input/Output: 3-Pin XLR
Net Weight: 2.2 kg
Gross weight: 2.6 kg
Net Dimensions: H(20) × W(20) × D(8) cm
Pack Size: H(23) × W(26) × D(26) cm

INSTALLATION

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit's weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.

The fixture may be installed in any orientation, but if installed horizontally with a downward beam-angle, water can potentially pool in the fan wells. Under normal operation the moisture will evaporate. However, in locations with high rainfall, you may wish to fabricate a rain shield above the fixture, or modify the position and orientation of the fixture to minimize pooling.

Two quarter-turn brackets are supplied with the fixture if it is to be flown above the ground. Rig the fixture to a support truss or structure using the supplied brackets and suitable clamps. Fasten a safety cable between the support structure and the attachment point on the fixture. The safety cable must be able to bear at least 10 times the weight of the fixture.

The package includes:

CONNECTION

The device is equipped with the following interfaces:

  1. DMX (in/out): XLR 3(5)-pin socket
  2. Power (in/out): powerCON socket

The connection is performed using cable with XLR-female -> XLR-Male plugs.

CAUTION! At the last fixture, the DMX signal has to be terminated with a terminator. Solder a 120Ω resistor between signal (-) and signal (+) into a XLR plug and plug it in the DMX output of the last fixture.

IMPORTANT! The maximum number of devices connected in series via power cable is 10 pcs.

The connection is performed using power cable with powerCON connector (included). The device must be operated by qualified personnel.

CAUTION! In the case of cable damage do not attempt to repair. Replacement or repair can be made only on the manufacturer or by a person with appropriate permissions.

Using lamp, the change rate of power voltage should be within ±10%, if the voltage is too high, it will shorten the light's life; if it's not enough, the lamp will be dark. Please restart it after turning off light for 20 minutes until full-cooling. Frequent switching will reduce the life span of lamps and bulbs; intermittent using will improve the life of bulbs and lamps.

Input Voltage Amperage Frequency Total Power
100-240 V AC 0,78 A 50 / 60 Hz 120 W

Control Menu

The fixture features a 4-digit display for menu navigation and control.

Manual Menu

Mode Description
D 001 DMX Address setting
CH 001-512 DMX Channel Mode (6 CH / 10 A CH / 10 B CH)
AU Auto Programs (01-99 Speed)
FA Fast Changing Programs (01-99 Speed)
PU Pulse Programs (01-99 Speed)
SO Sound Sensitivity (01-99 Sensitivity)
Red Red Channel (001-255)
Green Green Channel (001-255)
Blue Blue Channel (001-255)
White White Channel (001-255)
Amber Amber Channel (001-255)
UV UV Channel (001-255)
ST (Strobo) Strobe Effect (01 - 99 Slow > Fast)
Reno Reserved

DMX CHART

CH No 6 CH 10 A CH 10 B CH
1 Red Dimmer Dimmer
2 Green Red Strobo
3 Blue Green Macrocolor
000-050 Empty
051-100 Jump changing programm
101-150 Gradual changing prog.
151-200 Pulsive changing prog.
201-255 Sound activated on
4 White Blue Speed macro color
Speed from slow>fast, music activated, sensitivity from slow >fast
5 Amber White Red
6 UV Amber Green
7 UV Blue
8 Strobo White
9 Macrocolor Amber
000-050 Empty
051-100 Jump changing programm
101-150 Gradual changing prog.
151-200 Pulsive changing prog.
201-255 Sound activated on
10 UV

FLASH-BUTRYM Sp.j.

Skarbimierzyce 18 $\cdot$ 72-002 Dołuje $\cdot$ POLAND

WWW.FLASH-BUTRYM.PL

Models: RGBWA UV FLAT LED Par Light, RGBWA UV, FLAT LED Par Light, Light

File Info : application/pdf, 12 Pages, 1.21MB

PDF preview unavailable. Download the PDF instead.

F7100345-LED-PAR-64-18x12-RGBWA-UV-FLAT-EN

References

Adobe PDF Library 17.0 Adobe InDesign 18.3 (Windows)

Related Documents

Preview FLASH LED PAR 64 18x12 RGBWA+UV FLAT User Manual
User manual for the FLASH LED PAR 64 18x12 RGBWA+UV FLAT lighting fixture, providing detailed information on safety, product specifications, installation, connection, and DMX control.
Preview Flash LED PAR 64 18x15W 6in1 RGBWA+UV Zoom IP65 User Manual
User manual for the Flash LED PAR 64 18x15W 6in1 RGBWA+UV Zoom IP65 lighting fixture. Provides detailed information on safety precautions, product specifications, installation guidelines, connection methods, and DMX channel configurations.
Preview FLASH LED PAR 18x15W RGBWA+UV IP65 User Manual
User manual for the FLASH LED PAR 18x15W RGBWA+UV IP65 lighting fixture, covering introduction, safety information, product details, installation, connections, voltage specifications, and DMX channels.
Preview Flash Moving Head 12R User Manual
Comprehensive user manual for the Flash Moving Head 12R, detailing product information, safety guidelines, installation, connection, and DMX charts. Includes technical specifications and operational instructions for professional lighting applications.
Preview Flash LED PAR 36 12W RGB User Manual
User manual for the Flash LED PAR 36 12W RGB lighting fixture, detailing its features, safety precautions, installation, connection methods, and DMX channel configurations.
Preview FLASH parACCU 320 WDMX SET8 User Manual
User manual for the FLASH parACCU 320 WDMX SET8 DJ lighting fixture. Provides detailed information on product specifications, safety guidelines, menu operation, DMX control, and remote control functions.
Preview Flash Moving Head LED 150W Spot User Manual
User manual for the Flash Moving Head LED 150W Spot, covering introduction, safety information, product details, installation, connection, and DMX channel functions.
Preview Flash X2-Series LED Light Bar: Specifications, Features & Performance
Detailed specifications and features for the Flash X2-Series LED Light Bar. This high-performance light bar features OSRAM 5W LEDs, IP67 rating, a durable aluminum body, and an advanced hooded reflector system for optimal beam performance and long-range illumination up to 800 yards.