DAIKIN ONE+ TRANSLATION ADAPTOR INSTALLATION INSTRUCTIONS
© 2020 DAIKIN MANUFACTURING COMPANY, L.P.
19001 Kermier Rd. Waller, TX 77484
www.daikincomfort.com
P/N: IOD-7134B Date: October 2020
Important Warnings
⚠️ WARNING
Only personnel trained to install, adjust, service, or repair the equipment specified in this manual should service the unit. The manufacturer is not responsible for injury or property damage from improper service. Servicing the unit implies acceptance of responsibility for any resulting injury or damage. In jurisdictions requiring licenses, only licensed personnel should service the equipment. Improper installation, adjustment, servicing, or repair attempts without proper training may result in product damage, property damage, personal injury, or death.
PROP 65 WARNING FOR CALIFORNIA CONSUMERS
⚠️ WARNING
Cancer and Reproductive Harm - www.P65Warnings.ca.gov
⚡ HIGH VOLTAGE WARNING
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Safety Precautions
- Only qualified personnel should perform equipment installation.
- Turn off the power supply before starting wiring and do not turn it back on until work is completed. Refer to the indoor unit installation manual and wiring diagram.
- Ensure connectors are securely connected; unsecured connections can lead to improper communication or malfunction.
- Do not splice wires.
Items in the Packaging
Item | Qty. | Description |
---|---|---|
Translation Adaptor with power supply wire | 1 | A white rectangular box with a power cord attached. |
P1P2 connector (removable) | 1 | A small blue connector block with pins. |
Thermostat connector (removable) | 1 | A small blue connector block with pins. |
Front cover | 1 | A white plastic cover. |
Adaptor mounting plate | 1 | A white rectangular plate with mounting holes. |
Screws | 4 | A group of silver screws. |
Adhesive tape | 1 | A roll of white adhesive tape. |
Daikin One+ Thermostat | 1 | A white Daikin One+ thermostat unit with a screen. |
Thermostat terminal plate | 1 | A white terminal block with labeled terminals (D1, D2, C, R, etc.). |
Thermostat mounting plate | 1 | A white mounting plate. |
S21 wiring cable | 1 | A white cable with multiple colored wires and connectors. |
Welcome documents | 1 | A stack of white documents. |
Product Overview
The Daikin One+ Translation Adaptor connects the Daikin One+ thermostat to Daikin VRV, SkyAir, Single-Zone, and Multi-zone systems.
Note: The Daikin One+ Smart Thermostat is not compatible with other wireless or wired remote controllers. For retrofit projects, remove any existing remote controllers before installation.
Dimension Drawings
1. Translation Adaptor
A technical drawing showing the Daikin One+ Translation Adaptor, detailing its dimensions and the location of its S21 Terminal, P1P2 Terminal, Power Indicator, and S21/P1P2 Wiring Slot.
2. Mounting Plate
A technical drawing of the mounting plate, indicating its dimensions and screw hole placement.
Specification
Model | DTST-ONE-ADA-A |
---|---|
Description | Daikin One+ Smart Thermostat for VRV and Ductless Products |
Maximum Connections | 1 S21 Indoor Unit (cannot use with other wireless/wired remote controllers) 16 P1P2 Indoor Units (1 remote controller group) (cannot use with other wireless/wired remote controllers) |
Power Wire | 5.5 ft (included) |
Thermostat Wire | 125 ft (Field-supplied, 18AWG, 4-conductor non-shielded wire) |
Max Wiring Length: S21 Communication Wire | 5.5 ft (included) |
Max Wiring Length: P1P2 Communication Wire | 6 ft* (Field-supplied, 18AWG, 2-conductor non-shielded stranded wire). Do not use solid wire. |
Power Supply | Obtained from the Translation Adaptor |
Translation Adaptor Dimensions | 110-240 VAC |
Thermostat Dimensions | 6.8" x 3.4" x 0.8" |
Thermostat Adaptor Dimensions | 2.72" x 7.26" x 0.43" |
Thermostat Weight | 10.5 oz |
Thermostat Adaptor Weight | 18.4 oz |
Storage Temperature | 32°F to 120°F |
Operation Temperature (Thermostat) | 32°F to 120°F |
Operation Temperature (Thermostat Adaptor) | -40°F to 150°F |
Humidity | 20 to 95% RH (non-condensing) |
*P1P2 wire has a maximum wiring length of 1640 feet.
Selection of Mounting Location
The recommended mounting location varies by Daikin indoor unit type.
1. Wall-mounted unit
Applicable models: CTXS, FAQ, FTK_N, FTX_N, FTX_U, FTXG, FTXR, FTXS, FXAQ
For wall-mounted units, if refrigerant piping is on the right and the piping chase is not occupied, mounting the adaptor inside the indoor unit is recommended for concealment. Otherwise, mount it outside.
- Mounting inside the indoor unit piping chase: Utilize available space near the indoor unit mounting plate. Mount the adaptor's backplate to the wall, ensuring the high voltage power side faces the indoor unit electrical box. The front cover is optional in the piping chase. Some units may require front plate removal. If mounted inside, the adaptor cover is not needed.
Illustration shows an indoor unit mounting plate and space for a translator box.
2. Ducted and Air Handler Unit
Applicable models: CDXS, CXTQ, FBQ, FDMQ, FDXS, FTQ, FXDQ, FXMQ, FXSQ, FXTQ
Mount the adaptor to the side or top of the indoor unit using adhesive tape. It can also be mounted to a nearby sturdy surface. Ensure access to the indoor unit electrical box.
3. Ceiling Cassette Units
Applicable models: FCQ, FFQ, FXEQ, FXFQ, FXZQ
Mount the adaptor on top or the side of the indoor unit using adhesive tape. It can also be mounted above the ceiling using screws. Ensure access to the indoor unit electrical box.
4. Ceiling suspended Units
Applicable models: FHQ, FXHQ, FXUQ
Mount the adaptor on top of the indoor unit using adhesive tape (for FXUQ). It can also be mounted above the ceiling. Ensure access to the indoor unit electrical box.
5. Floor-mounted and Floor Standing Units
Applicable models: FVXS, FXLQ, FXMQ, FXNQ
Mount the translator box to the side of the indoor unit. Select a location that minimizes the visibility of the adaptor and wiring, while providing access to the indoor unit electrical box.
Illustration shows an indoor unit mounting plate and space for a translator box.
Mounting outside of the indoor unit
If refrigerant piping is left-side installed and occupies the piping chase, mount the adaptor outside the indoor unit. Select a location that provides access to the indoor unit electrical box and minimizes the visibility of the adaptor and wiring cables.
Mounting
The Translation Adaptor offers two mounting methods.
1. Mount with two screws
Use the provided screws to mount the adaptor to a suitable wall surface. Do not use screws to mount directly to the indoor unit. Mount the backplate to the selected surface using the two screws.
Illustration shows the adaptor, mounting plate, and screws for wall mounting. The front cover is shown as optional.
2. Mount with double-sided adhesive tape
Use the provided double-sided adhesive tape to mount the translator box directly onto the indoor unit. The mounting plate has a recess for the tape to minimize the gap.
To ensure durable adhesive performance:
- Clean the mounting surface thoroughly. A 50:50 isopropyl alcohol and water mixture is recommended to remove dust and oils. Improper cleaning will prevent a proper chemical bond.
- For flat surfaces, use the provided adhesive tape. Apply firm pressure for 30 seconds to improve adhesive contact and bond strength.
- For non-flat surfaces, consider using thicker adhesive tape, such as 3M Super Strength Molding Tape 03609, for better contact compliance on curved surfaces.
Illustration shows adhesive tape applied to the mounting plate, which attaches to the adaptor. The front cover is also shown.
Wiring
1. Overview
The translator box connects between the indoor unit and the Daikin One+ Thermostat, drawing power from the indoor unit or an external source.
For S21 Indoor Units
Schematic diagram illustrating connections from the Thermostat terminal plate to the Translation adaptor, and then to the S21 connector on the indoor unit/Interface Adaptor and the Indoor unit power supply terminal (110-230VAC).
For P1P2 Indoor Units
Schematic diagram illustrating connections from the Thermostat terminal plate to the Translation adaptor, and then to the Indoor unit terminal block (P1, P2, F1, F2, T1, T2) and Indoor unit power supply terminal (110-230VAC).
Wiring Requirement Table
Wire Name | Type | Connected to | Max Length |
---|---|---|---|
High-Voltage Power Line | 3-wire, included in the package | Indoor unit power terminal or external power source | 5 1/2 ft |
Thermostat Wire | Field-supplied, 18 AWG, 4-conductor non-shielded wire | Daikin One+ Thermostat | 125 ft |
S21 Communication Wire | 5-conductor wire with connectors, included in the package | S21 Terminal on the indoor unit PCB or S21 Terminal on the Interface adaptor | 5.5 ft |
P1P2 Communication Wire | Field-supplied, 18 AWG, 2-conductor non-shielded stranded wire | P1P2 Terminal on the indoor unit | 6 ft* |
*Max P1P2 wire length is 1640 ft.
Communication Terminal Usage
Only one communication terminal (S21 or P1P2) should be used per indoor unit.
Indoor Unit Model Communication Terminal
Indoor Unit Model | Communication Terminal |
---|---|
CDXS, CTXS, FDXS, FTK_N, FTX_N, FTX_U, FTXG, FTXR, FTXS, FVXS | S21 Terminal |
CXTQ, FAQ, FBQ, FDMQ, FTQ, FCQ, FHQ, FFQ, FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXNQ, FXSQ, FXTQ, FXUQ, FXZQ | P1P2 Terminal |
2. Thermostat Wiring
The Daikin One+ Smart Thermostat receives power directly from the adaptor. Wire the thermostat wire first, followed by the S21 or P1P2 communication wire. Connect the thermostat terminals (D1, D2, C, R) on the adaptor to the corresponding terminals (1, 2, C, R) on the Daikin One+ Thermostat's terminal plate using 18AWG 4-conductor non-shielded wire. Ensure correct termination combinations as shown in the diagram.
Schematic diagram showing the connection between the Thermostat Terminal Plate and the Thermostat Terminal on the Adaptor via Thermostat Wire. Labels for D1, D2, C, R are shown on both.
3. S21 Communication Wiring
The S21 Communication terminal is for S21 indoor units (Single and Multi-splits). Use the included S21 wiring cable, utilizing the anchors and S21/P1P2 wiring slot to route the cable towards the high voltage side of the Adaptor.
Schematic diagram showing the S21 Terminal on the adaptor connected via S21 wiring cable to an S21 Connector. Power and S21 LEDs are indicated.
Interface Adaptor Requirements
The S21 wiring cable connects to the S21 connector on the indoor unit PCB or the Interface Adaptor, depending on the indoor unit model. Refer to the indoor unit installation manual for S21 connector location.
Some single-zone and multi-zone indoor units lack an S21 connector on the PCB. For these, an Interface Adaptor must be ordered separately.
Indoor Unit Models Requiring Interface Adaptor
Indoor Unit Models | Required Interface Adaptor |
---|---|
FTX09NMVJU, FTX12NMVJU, FTK09NMVJU, FTK12NMVJU, FTX15NMVJU, FTX18NMVJU, FTX24NMVJU, FTK18NMVJU, FTK24NMVJU | KRP067A41E KRP980B2E |
4. P1P2 Communication Wiring
The P1P2 Communication terminal is for P1P2 indoor units only. Use 18-2-non-shielded stranded wire to connect the P1P2 terminal on the Adaptor to the P1P2 terminal of the applicable indoor unit. Do not use the S21 terminal if the P1P2 terminal is used.
Schematic diagram showing the P1P2 Terminal on the adaptor connected via P1P2 wire to a P1P2 Terminal on the indoor unit. Power and P1P2 LEDs are indicated.
5. Power Supply
The P1P2 Communication terminal is for P1P2 indoor units only. Use 18-2-non-shielded stranded wire to connect the P1P2 terminal on the Adaptor to the P1P2 terminal of the applicable indoor unit. Do not use the S21 terminal if P1P2 terminal is used.
Schematic diagram showing power supplied from the indoor unit via the Thermostat Terminal Plate, Thermostat Wire, and High-Voltage Power Line to the Translation Adaptor, which also connects to the Indoor Unit Supply Terminal (L1, L2, G).
⚡ HIGH VOLTAGE WARNING
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
6. Check Power Indicators
After wiring and installation are complete, turn on power to the indoor unit. Use the 'Power' indicator LED on the Adaptor to confirm successful wiring. The 'S21' LED will illuminate if the indoor unit uses S21 termination, and the 'P1P2' LED will illuminate if it uses P1P2 termination. Once power and communication are verified, use the rubber grommet to cover the LEDs to prevent light bleed-through when the unit and adaptor are fully installed.
Illustration showing the adaptor's connection terminals with labeled LEDs: P1P2, S21, PWR.
Illustration showing the adaptor's connection terminals with labeled LEDs: P1P2, S21, PWR.
For some wall-mounted units, the front cover may need to be removed to fit inside the piping chase. For other units, reattach the front cover by pressing it down until it snaps into place.
Customer Feedback
Daikin values customer feedback. Please share your comments via the feedback form at: https://daikincomfort.com/contact-us
Our commitment to quality products may result in specification changes without notice.