Amana AR9T96 / AD9T96 Two-Stage ECM Gas Furnace
Heating Input: 30,000–120,000 BTU/H
AFUE: Up to 96%
Product Overview
The Amana AR9T96 and AD9T96 series are two-stage, multi-speed ECM gas furnaces engineered for efficient, quiet, and reliable home heating. These units feature advanced technology for optimal comfort and energy savings.
Standard Features
- Energy-efficient multi-speed ECM blower motor
- Heavy-duty stainless-steel tubular heat exchanger
- Stainless-steel secondary heat exchanger
- Two-stage gas valve for quiet, economical heating
- Durable Silicon Nitride igniter
- Quiet two-speed induced draft blower
- Self-diagnostic control board with constant memory fault code history output to an LED
- Color-coded low-voltage terminals for electronic air cleaner and humidifier connections
- Low continuous fan speed options for quiet air circulation
- Compliance with California 40 ng/J Low NOx emissions standard
- Note: Cannot be installed in California's South Coast Air Quality Management District (SCAQMD) and San Joaquin Valley Air Pollution Control District (SJVAPCD).
Cabinet Features
- Designed for multi-position installation: AR9T96 models support upflow and horizontal left/right configurations; AD9T96 models support downflow and horizontal left/right configurations.
- Certified for direct vent (2-pipe) or non-direct vent (1-pipe) installations.
- Easy-to-install top venting with optional side venting available for AR9T96/upflow models.
- Convenient left or right connection points for gas and electrical service.
- Cabinet air leakage (QLeak) of 2% or less.
- Heavy-gauge steel cabinet with a durable finish.
- Fully insulated heat exchanger and blower section for enhanced efficiency.
- Airtight solid bottom or side return with easy-cut tabs for simplified installation.
Nomenclature Explained
The model number provides key information about the furnace's configuration and capabilities:
- Brand: Amana
- Configuration: R (Upflow/Horizontal), D (Downflow/Horizontal)
- Motor: 9 (Nine Speed ECM)
- Gas Valve: T (2 Stage)
- AFUE: 96 (96% AFUE)
- Heating Input (MBTU/H): e.g., 040 (40,000 BTU/h), 120 (120,000 BTU/h)
- Cabinet Width: A (14"), B (17½"), C (21"), D (24½")
- Engineering: N (Low NOx, > 40 NG/J), X (Standard NOx, < 40 NG/J)
Product Specifications Summary
The Amana AR9T96 and AD9T96 series offer a range of models with varying capacities and specifications:
AR9T96 Series Highlights:
- Heating Input: 30,000 to 120,000 BTU/h
- AFUE: 96%
- Temp. Rise Range: Typically 20-65°F, varying by model.
- Vent Diameter: 2" - 3"
- No. of Burners: 2 to 6
- Circulator Blower: Available AC @ 0.5" ESP ranges from 1.5-2 to 3-5, with horsepower from 1/2 to 1 HP.
- Electrical Data: Min. Circuit Ampacity ranges from 7.8 to 14.4 A; Max. Overcurrent Protection Device ranges from 15 to 25 A.
- Shipping Weight: Ranges from 106 to 154 lbs.
AD9T96 Series Highlights:
- Heating Input: 40,000 to 100,000 BTU/h
- AFUE: 96%
- Temp. Rise Range: Typically 25-70°F, varying by model.
- Vent Diameter: 2" - 3"
- No. of Burners: 2 to 5
- Circulator Blower: Available AC @ 0.5" ESP ranges from 1.5-3 to 3-5, with horsepower from 1/2 to 1 HP.
- Electrical Data: Min. Circuit Ampacity ranges from 7.8 to 14.4 A; Max. Overcurrent Protection Device ranges from 15 to 25 A.
- Shipping Weight: Ranges from 112 to 140 lbs.
Detailed specifications for each model, including specific outputs, blower sizes, and filter requirements, are available in the full product documentation.
Dimensions and Clearances
The furnaces are available in various cabinet widths, from 14" up to 24½" for the AR9T96 series and 17½" to 21" for the AD9T96 series. Detailed diagrams illustrate unit dimensions, connection points (gas, electrical, vent, drain), and air intake/discharge locations for different installation positions (upflow, horizontal, downflow). Minimum clearances to combustible materials are specified for sides, rear, front, bottom, flue, and top, which vary based on the installation position.
Airflow Specifications
The document includes comprehensive tables detailing airflow performance (CFM) at various external static pressures for both heating and cooling operations across different thermostat tap settings and models. These tables are crucial for proper system balancing and performance tuning.
Temperature Rise Chart
A chart is provided to illustrate the relationship between BTU output and temperature rise for different airflow rates (CFM). It includes key formulas for calculating performance: BTU/h Output = CFM x 1.08 x Rise, and Rise = BTU/h Output / (CFM x 1.08).
Wiring Diagram
A detailed wiring diagram is included, illustrating the electrical connections for the furnace. It maps out the integration of components such as the hot surface igniter, two-stage gas valve, pressure switches (high and low fire), flame sensor, limit controls, induced draft blower, circulator blower, and the integrated control module. The diagram also provides essential notes on safety precautions, recommended replacement parts, grounding requirements, and error code status displays via a seven-segment display.
Available Accessories
A range of accessories are available to enhance installation and functionality, including:
- Vent Kits (Concentric, Flush Mount)
- Drain Kits
- External Filter Racks
- Fossil Fuel (Dual Fuel) Kits
- High-Altitude Kits (Natural Gas and LP Gas)
- Horizontal Drain Tubing Kits
- Low LP Gas Pressure Switches
- LP Conversion Kits
- Downflow Sub-Bases
Warranty Information
Amana offers a comprehensive warranty package. This includes a Lifetime Heat Exchanger Limited Warranty, a Lifetime Unit Replacement Limited Warranty (both valid for as long as the original homeowner owns the home), and a 10-Year Parts Limited Warranty. Online registration within 60 days of installation is required to activate these warranties, with specific exceptions for installations in California or Québec. Warranty coverage durations may differ in Texas and Florida.