Amana AR9S96 / AD9S96 Single-Stage, Multi-Speed ECM Gas Furnace
HEATING INPUT: 40,000–120,000 BTU/H
AFUE: UP TO 96% AFUE The Amana AR9S96 and AD9S96 series furnaces offer a range of models with varying heating inputs and outputs, designed for efficient and reliable performance. Detailed dimensional drawings and minimum clearance requirements are provided for both AR9S96 and AD9S96 models. C = If placed on combustible floor, the floor MUST be wood ONLY. C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. The document includes detailed tables for Heating Airflow Data and Cooling & Circulation Airflow for both AR9S96 and AD9S96 models, correlating CFM and Temperature Rise with External Static Pressure. This section provides data on CFM and Temperature Rise for various models across different external static pressures (0.1 to 0.8 inches water column). This section provides data on CFM and Watts for various models across different external static pressures (0.1 to 0.8 inches water column) for cooling and circulation. This section provides data on CFM and Temperature Rise for various AD9S96 models across different external static pressures (0.1 to 0.8 inches water column). This section provides data on CFM and Watts for various AD9S96 models across different external static pressures (0.1 to 0.8 inches water column) for cooling and circulation. A comprehensive wiring diagram is provided, illustrating the electrical connections for the furnace components. It includes a legend for wire colors and designations, as well as error code status indicators. Important Notes on Wiring: WARNING: DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. A variety of accessories are available for the AR9S96 and AD9S96 furnaces, including vent kits, drain kits, filter racks, flush mount vent kits, fossil fuel kits, high-altitude kits, and LP conversion kits. Specific accessory availability varies by model. A chart is provided to visually determine the temperature rise based on BTU Output and Airflow (CFM).Standard Features
Cabinet Features
Product Specifications
AR9S96 Product Specifications
Model High Fire Input (BTU/h) High Fire Output (BTU/h) AFUE (%) Temp. Rise Range (°F) Vent Diameter (in) No. of Burners Circulator Blower (AC @ 0.5" ESP) Blower Size (D x W) Blower HP @ RPM Filter Size (in²) (QTY) Min. Circuit Ampacity Max. Overcurrent Device (amps) Shipping Weight (lbs) AR9S96 0403AN 40,000 38,440 96 25-55 2" - 3" 2 1.5-3 11" x 6" 1/2 @ 9 (1) 16x25 (side/bottom) 9.7 15 108 AR9S96 0603BN 60,000 57,660 96 35-65 2" - 3" 3 1.5-3 11" x 8" 1/2 @ 9 (1) 16x25 (side/bottom) 10.1 15 118 AR9S96 0803BN 80,000 76,880 96 35-65 2" - 3" 4 1.5-3 11" x 8" 3/4 @ 9 (1) 16x25 (side/bottom) 10.1 15 118 AR9S96 0804CN 80,000 76,880 96 25-55 2" - 3" 4 1.5-4 11" x 10" 3/4 @ 9 (1) 16x25 (side/bottom) 13.7 20 141 AR9S96 0805CN 80,000 76,880 96 25-55 2" - 3" 4 1.5-4 11" x 10" 3/4 @ 9 (1) 16x25 (side/bottom) 16.7 25 142 AR9S96 1005CN 100,000 96,100 96 30-60 2" - 3" 5 3-5 11" x 10" 1 @ 9 (1) 20x25 (bottom) or (2) 16x25 (side) 16.7 25 144 AR9S96 1205DN 120,000 115,320 96 35-65 3" 6 3-5 11" x 11" 1 @ 9 (1) 20x25 (bottom) or (2) 16x25 (side) 16.7 25 156 AD9S96 Product Specifications
Model High Fire Input (BTU/h) High Fire Output (BTU/h) AFUE (%) Temp. Rise Range (°F) Vent Diameter (in) No. of Burners Circulator Blower (AC @ 0.5" ESP) Blower Size (D x W) Blower HP @ RPM Filter Size (in²) (QTY) Min. Circuit Ampacity Max. Overcurrent Device (amps) Shipping Weight (lbs) AD9S96 0403BN 40,000 38,440 96 25-55 2" - 3" 2 1.5-3 11" x 8" 1/2 @ 9 (2) 10x20 (top return) or (1) 14x20 (bottom) 10.1 15 113 AD9S96 0603BN 60,000 57,660 96 35-65 2" - 3" 3 1.5-3 11" x 8" 1/2 @ 9 (2) 10x20 (top return) or (1) 14x20 (bottom) 10.1 15 116 AD9S96 0804CN 80,000 76,880 96 40-70 2" - 3" 4 2.5-4 11" x 10" 3/4 @ 9 (2) 10x20 (top return) or (1) 16x25 (top return) 13.7 20 141 AD9S96 1005CN 100,000 95,000 95 40-70 2" - 3" 5 3-5 11" x 10" 1 @ 9 (1) 16x25 (top return) or (1) 20x25 (top return) 16.7 25 144 AD9S96 1205DN 120,000 114,000 95 45-75 3" 6 3-5 11" x 11" 1 @ 9 (1) 16x25 (top return) or (1) 20x25 (top return) 16.7 25 156 Dimensions
AR9S96 Dimensions
Model A (in) B (in) C (in) D (in) E (in) AR9S960403AN 14" 12½" 10%" 85%" 10%" AR9S960603BN 17½" 16" 13%" 12%" 13%" AR9S960803BN 17½" 16" 13%" 12%" 13%" AR9S960804CN 21" 19½" 17%" 16" 17½" AR9S960805CN 21" 19½" 17%" 16" 17½" AR9S961005CN 21" 19½" 17%" 16" 17½" AR9S961205DN 24½" 23" 20%" 19%" 20%" Minimum Clearances to Combustible Materials (AR9S96)
Position Sides Rear Front Bottom Flue Top Upflow 0" 0" 1" C 0" 1" Horizontal 6" 0" ALCOVE C 0" 4" AD9S96 Dimensions
Model A (in) B (in) C (in) D (in) E (in) F (in) AD9S960403BN 17½" 16" 13%" 12%" 13%" 13%" AD9S960603BNA 17½" 16" 13%" 12%" 13%" 13%" AD9S960804CN 21" 19½" 17%" 16" 17½" 17½" AD9S961005CN 21" 19½" 17%" 16" 17½" 17½" AD9S961205DN 24½" 23" 20%" 19%" 20%" 20%" Minimum Clearances to Combustible Materials (AD9S96)
Position Sides Rear Front Bottom Flue Top Downflow 0" 0" 1" NC 0" 1" Horizontal 6" 0" ALCOVE C 0" 4" Airflow Data
AR9S96 Heating Airflow Data
AR9S96 Cooling & Circulation Airflow
AD9S96 Heating Airflow Data
AD9S96 Cooling & Circulation Airflow
Wiring Diagram
Accessories
Available Accessories for AR9S96 Models
Model Description AR9S96 0403ANA AR9S96 0603BNA AR9S96 0803BNA AR9S96 0804CNA AR9S96 0805CNA AR9S96 1005CNA AR9S96 1205DNA 72950 Concentric Vent Kit (2") ✓ ✓ ✓ ✓ ✓ ✓ ✓ 72951 Concentric Vent Kit (3") ✓ ✓ ✓ ✓ ✓ ✓ ✓ RF000142 Drain Kit Horizontal Left Vertical Flue ✓ ✓ ✓ ✓ ✓ ✓ ✓ EFRO2 External Filter Rack with 16"x25" Permanent Filter ✓ ✓ ✓ ✓ ✓ ✓ ✓ 0170K00000S Flush Mount Vent Kit - 3" or 2" ✓ ✓ ✓ ✓ ✓ ✓ ✓ 0170K00001S Flush Mount Vent Kit - 2" ✓ ✓ ✓ ✓ ✓ ✓ ✓ AFE18-60A Fossil Fuel (Dual Fuel) Kit ✓ ✓ ✓ ✓ ✓ ✓ ✓ HASFK High-Altitude Natural Gas Kit TBD HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK High-Altitude LP Gas Kit TBD HASFK-6 HASFK-6 HASFK-6 HASFK-5 HASFK-5 HASFK-5 0270F05404 Horizontal Drain Tubing Kit ✓ ✓ ✓ ✓ ✓ ✓ ✓ LPM-33 LP Conversion Kits ✓ ✓ ✓ ✓ ✓ ✓ ✓ Available Accessories for AD9S96 Models
Model Description AD9S96 0403BNA AD9S96 0603BNA AD9S96 0804CNA AD9S96 1005CNA AD9S96 1205DNA 72950 Concentric Vent Kit (2") ✓ ✓ ✓ ✓ ✓ 72951 Concentric Vent Kit (3") ✓ ✓ ✓ ✓ ✓ CFSB17 Downflow Sub-Base 17.5" ✓ ✓ CFSB21 Downflow Sub-Base 21" ✓ ✓ ✓ CFSB24 Downflow Sub-Base 24" ✓ RF000142 Drain Kit Horizontal Left Vertical Flue ✓ ✓ ✓ ✓ ✓ EFRO2 External Filter Rack with 16"x25" Permanent Filter ✓ ✓ ✓ 0170K00000S Flush Mount Vent Kit - 3" or 2" ✓ ✓ ✓ ✓ ✓ 0170K00001S Flush Mount Vent Kit - 2" ✓ ✓ ✓ ✓ ✓ AFE18-60A Fossil Fuel (Dual Fuel) Kit ✓ ✓ ✓ ✓ ✓ HASFK High-Altitude Natural Gas Kit HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK-4 HASFK High-Altitude LP Gas Kit HASFK-5 HASFK-5 HASFK-5 HASFK-5 HASFK-5 0270F05405 Horizontal Drain Tubing Kit ✓ ✓ ✓ ✓ ✓ LPM-33 LP Conversion Kits ✓ ✓ ✓ ✓ ✓ Temperature Rise Range Chart