Amana AM9C96 Two-Stage, Multi-Speed ECM Gas Furnace
Model: AM9C96
Heating Input: 30,000–120,000 BTU/H
Efficiency: Up to 96% AFUE
Description: A high-efficiency, two-stage, multi-speed ECM gas furnace designed for quiet and economical heating.
Standard Features
- Energy-efficient multi-speed ECM blower motor
- Heavy-duty stainless-steel tubular heat exchanger
- Stainless-steel secondary heat exchanger
- Two-stage gas valve provides quiet, economical heating
- Durable Silicon Nitride igniter
- Quiet two-speed induced draft blower
- Self-diagnostic control board with constant memory fault code history output to a LED
- Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier
- Low continuous fan speed options offer quiet air circulation
- All models comply with California 40 ng/J Low NOx emissions standard
- Note: Installation is restricted in California's South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
Cabinet Features
- Designed for multi-position installation: upflow, horizontal left or right
- Certified for direct vent (2-pipe) or non-direct vent (1-pipe)
- Easy-to-install top venting with optional side venting
- Convenient left or right connection for gas and electrical service
- Cabinet air leakage (QLeak) ≤ 2%
- Heavy-gauge steel cabinet with durable finish
- Fully insulated heat exchanger and blower section
- Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications
Nomenclature: Model Number Breakdown
The Amana AM9C96 model number follows a specific structure:
Position | Description |
---|---|
1 | Brand: A - Amana® Brand |
2 | Configuration: M - Upflow/Horizontal, C - Downflow/Horizontal |
3 | Motor: 9 - Nine Speed ECM |
4 | Gas Valve: C - 2 Stage |
5,6 | AFUE: 96 - 96% AFUE |
7,8,9 | MBTU/h (Heating Capacity): e.g., 030 (30,000 BTU/h), 060 (60,000 BTU/h), 120 (120,000 BTU/h) |
10 | Maximum CFM: 3 - 1200 CFM, 4 - 1600 CFM, 5 - 2000 CFM |
11 | Cabinet Width: A - 14", B - 17½", C - 21", D - 24½" |
12 | Engineering (NOx): N = > 40 NG/J NOx, X = < 40 NG/J NOx |
13,14 | Major/Minor Revisions: A - Initial Release, B - 1st Revision |
Product Specifications
Summary of key product specifications across different models.
Category | Specification | AM9C96 0303ANA | AM9C96 0403ANA | AM9C96 0603ANA | AM9C96 0603BNA | AM9C96 0803BNA | AM9C96 0804CNA | AM9C96 1004CNA | AM9C96 1005CNA | AM9C96 1205DNA |
---|---|---|---|---|---|---|---|---|---|---|
Heating Data | High Fire Input¹ (BTU/h) | 30,000 | 40,000 | 60,000 | 60,000 | 80,000 | 80,000 | 100,000 | 100,000 | 120,000 |
High Fire Output¹ (BTU/h) | 28,800 | 38,400 | 57,600 | 57,600 | 76,800 | 76,800 | 96,000 | 96,000 | 115,200 | |
Low-Fire Input¹ (BTU/h) | 21,000 | 28,000 | 42,000 | 42,000 | 56,000 | 56,000 | 70,000 | 70,000 | 84,000 | |
Low-Fire Output¹ (BTU/h) | 20,160 | 26,880 | 40,320 | 40,320 | 53,760 | 53,760 | 67,200 | 67,200 | 80,640 | |
AFUE² | 96 | 96 | 96 | 96 | 96 | 96 | 96 | 96 | 96 | |
Temp. Rise Range (°F) | 20-50 | 20-50 | 30-60 | 35-65 | 35-65 | 25-55 | 35-65 | 35-65 | 35-65 | |
Vent Diameter³ | 2"-3" | 2"-3" | 2"-3" | 2"-3" | 2"-3" | 2"-3" | 2"-3" | 2"-3" | 2"-3" | |
No. of Burners | 2 | 2 | 3 | 3 | 4 | 4 | 5 | 5 | 6 | |
Circulator Blower | Available AC @ 0.5" ESP | 1.5-2 | 1.5-3 | 1.5-3 | 1.5-3 | 1.5-3 | 2.5-4 | 1.5-4 | 3-5 | 3-5 |
Size (D x W) | 11" x 6" | 11" x 6" | 11" x 6" | 11" x 8" | 11" x 8" | 11" x 10" | 11" x 10" | 11" x 10" | 11" x 11" | |
Horsepower @ 1075 RPM | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | 1 | 1 | 1 | |
Speed | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 9 | |
Filter Size (in²) (Qty) | (1) 16 x 25 (side) or (1) 14 x 25 (bottom) | (1) 16 x 25 (side) or (1) 14 x 25 (bottom) | (1) 16 x 25 (side) or (1) 14 x 25 (bottom) | (1) 16 x 25 (side or bottom) | (1) 16 x 25 (side or bottom) | (1) 16 x 25 (side or bottom) | (1) 16 x 25 (side or bottom) | (1) 20 x 25 (bottom) or (2) 16 x 25 (side) | (1) 20 x 25 (bottom) or (2) 16 x 25 (side) | |
Electrical Data | Min. Circuit Ampacity⁴ | 8.6 | 8.6 | 8.6 | 8 | 8 | 11.6 | 13.3 | 13.3 | 13.3 |
Max. Overcurrent (amps)⁵ | 15 | 15 | 15 | 15 | 15 | 15 | 20 | 20 | 20 | |
Shipping Weight (LBS) | 106 | 106 | 110 | 115 | 118 | 123 | 140 | 140 | 154 |
¹ Natural Gas BTU/h
² DOE AFUE based upon Isolated Combustion System (ICS)
³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/ code requirements and must be 2" or 3" diameter PVC.
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes: All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas Service Connection ½" FPT. Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
Dimensions
Diagram Description: The diagrams show the Left Side View, Front View, and Right Side View of the furnace, illustrating key dimensions and connection points. Key features include Air Discharge, Air Intake, Gas Supply, Electrical Outlets, and Condensate Drain connections. Dimensions are provided in inches.
Model | A (Air Discharge) | B (Air Discharge) | C (Air Discharge) | D (Air Return) | E (Air Return) |
---|---|---|---|---|---|
AM9C960303ANA | 14" | 12½" | 10½" | 8⅝" | 10⅛" |
AM9C960403ANA | 14" | 12½" | 10½" | 8⅝" | 10⅛" |
AM9C960603ANA | 14" | 12½" | 10½" | 8⅝" | 10⅛" |
AM9C960603BNA | 17½" | 16" | 13%" | 12%" | 13%" |
AM9C960803BNA | 17½" | 16" | 13%" | 12%" | 13%" |
AM9C960804CNA | 21" | 19%" | 17%" | 16" | 17½" |
AM9C961004CNA | 21" | 19½" | 17%" | 16" | 17½" |
AM9C961005CNA | 21" | 19½" | 17%" | 16" | 17½" |
AM9C961205DNA | 24½" | 23" | 20%" | 19%" | 20%" |
Minimum Clearances to Combustible Materials
Position | Sides | Rear | Front | Bottom | Flue | Top |
---|---|---|---|---|---|---|
Upflow | 0" | 0" | 3" | C | 0" | 1" |
Horizontal | 6" | 0" | 3" | C | 0" | 6" |
C = If placed on combustible floor, the floor MUST be wood ONLY.
Airflow Specifications
The following tables provide airflow data for Low Stage Cooling, High Stage Cooling, and Heating, detailing CFM values at various external static pressures and thermostat calls.
Low Stage Cooling Airflow Data
Model | Thermostat Call | Tap # | External Static Pressure (Inches Water Column) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
0.1 CFM | 0.2 CFM | 0.3 CFM | 0.4 CFM | 0.5 CFM | 0.6 CFM | 0.7 CFM | 0.8 CFM | |||
*M9C96 0303AN | Y/Y1 | F01 | 753 | 708 | 663 | 616 | 568 | 513 | 470 | 423 |
*M9C96 0303AN | Y/Y1 | F02 | 915 | 883 | 845 | 809 | 773 | 730 | 690 | 650 |
*M9C96 0303AN | Y/Y1 | F03 | 529 | 518 | 461 | 394 | 343 | 288 | 223 | N/A |
*M9C96 0303AN | Y/Y1 | F04^ | 880 | 843 | 807 | 768 | 723 | 683 | 643 | 590 |
*M9C96 0303AN | Y/Y1 | F05 | 1055 | 1022 | 990 | 959 | 930 | 891 | 858 | 825 |
*M9C96 0303AN | Y/Y1 | F06 | 1101 | 1072 | 1040 | 1010 | 980 | 949 | 918 | 881 |
*M9C96 0303AN | Y/Y1 | F07 | 1190 | 1162 | 1134 | 1104 | 1077 | 1042 | 1013 | 982 |
*M9C96 0303AN | Y/Y1 | F08 | 1183 | 1157 | 1130 | 1103 | 1077 | 1047 | 1018 | 988 |
*M9C96 0303AN | Y/Y1 | F09 | 1229 | 1206 | 1178 | 1153 | 1128 | 1100 | 1070 | 1042 |
*M9C96 0403AN | Y/Y1 | F01 | 733 | 691 | 650 | 602 | 553 | 498 | 448 | 402 |
*M9C96 0403AN | Y/Y1 | F02 | 1051 | 1024 | 996 | 966 | 935 | 907 | 868 | 836 |
*M9C96 0403AN | Y/Y1 | F03 | 665 | 620 | 570 | 517 | 462 | 407 | 359 | 309 |
*M9C96 0403AN | Y/Y1 | F04^ | 915 | 881 | 846 | 814 | 780 | 737 | 695 | 652 |
*M9C96 0403AN | Y/Y1 | F05 | 1138 | 1114 | 1092 | 1064 | 1035 | 1006 | 977 | 947 |
*M9C96 0403AN | Y/Y1 | F06 | 887 | 855 | 823 | 790 | 751 | 705 | 666 | 608 |
*M9C96 0403AN | Y/Y1 | F07 | 1189 | 1163 | 1138 | 1111 | 1085 | 1059 | 1032 | 1001 |
*M9C96 0403AN | Y/Y1 | F08 | 1266 | 1243 | 1218 | 1197 | 1172 | 1148 | 1123 | 1099 |
*M9C96 0403AN | Y/Y1 | F09 | 1342 | 1324 | 1305 | 1280 | 1263 | 1239 | 1216 | 1193 |
*M9C96 0603AN | Y/Y1 | F01 | 900 | 867 | 830 | 798 | 758 | 718 | 682 | 645 |
*M9C96 0603AN | Y/Y1 | F02 | 1292 | 1272 | 1248 | 1227 | 1206 | 1184 | 1162 | 1137 |
*M9C96 0603AN | Y/Y1 | F03 | 688 | 649 | 603 | 551 | 499 | 447 | 405 | 359 |
*M9C96 0603AN | Y/Y1 | F04^ | 866 | 830 | 797 | 759 | 717 | 675 | 634 | 591 |
*M9C96 0603AN | Y/Y1 | F05 | 1223 | 1195 | 1176 | 1149 | 1124 | 1101 | 1074 | 1047 |
*M9C96 0603AN | Y/Y1 | F06 | 1037 | 1004 | 975 | 950 | 921 | 886 | 853 | 823 |
*M9C96 0603AN | Y/Y1 | F07 | 1079 | 1053 | 1025 | 1000 | 970 | 941 | 911 | 873 |
*M9C96 0603AN | Y/Y1 | F08 | 1128 | 1099 | 1075 | 1050 | 1022 | 993 | 965 | 937 |
*M9C96 0603AN | Y/Y1 | F09 | 1171 | 1148 | 1124 | 1096 | 1070 | 1045 | 1017 | 988 |
*M9C96 0603BN | Y/Y1 | F01 | 914 | 864 | 815 | 762 | 704 | 654 | 604 | 560 |
*M9C96 0603BN | Y/Y1 | F02 | 1121 | 1083 | 1041 | 996 | 953 | 906 | 861 | 818 |
*M9C96 0603BN | Y/Y1 | F03 | 758 | 696 | 636 | 572 | 512 | 460 | 412 | N/A |
*M9C96 0603BN | Y/Y1 | F04^ | 960 | 917 | 864 | 812 | 764 | 708 | 661 | 614 |
*M9C96 0603BN | Y/Y1 | F05 | 1164 | 1123 | 1084 | 1042 | 1003 | 960 | 920 | 871 |
*M9C96 0603BN | Y/Y1 | F06 | 1219 | 1180 | 1141 | 1102 | 1062 | 1020 | 978 | 940 |
*M9C96 0603BN | Y/Y1 | F07 | 1273 | 1240 | 1207 | 1171 | 1128 | 1089 | 1051 | 1012 |
*M9C96 0603BN | Y/Y1 | F08 | 1307 | 1270 | 1235 | 1198 | 1160 | 1122 | 1083 | 1043 |
*M9C96 0603BN | Y/Y1 | F09 | 1427 | 1390 | 1362 | 1327 | 1297 | 1260 | 1224 | 1193 |
*M9C96 0803BN | Y/Y1 | F01 | 1205 | 1169 | 1131 | 1091 | 1053 | 1014 | 974 | 934 |
*M9C96 0803BN | Y/Y1 | F02 | 1415 | 1385 | 1355 | 1322 | 1291 | 1255 | 1219 | 1186 |
*M9C96 0803BN | Y/Y1 | F03 | 696 | 635 | 568 | 500 | 442 | 390 | 336 | 255 |
*M9C96 0803BN | Y/Y1 | F04^ | 1152 | 1112 | 1076 | 1035 | 996 | 954 | 916 | 868 |
*M9C96 0803BN | Y/Y1 | F05 | 1321 | 1287 | 1251 | 1217 | 1181 | 1146 | 1112 | 1072 |
*M9C96 0803BN | Y/Y1 | F06 | 901 | 851 | 801 | 746 | 690 | 638 | 587 | 543 |
*M9C96 0803BN | Y/Y1 | F07 | 1112 | 1076 | 1032 | 992 | 949 | 905 | 858 | 819 |
*M9C96 0803BN | Y/Y1 | F08 | 1290 | 1252 | 1215 | 1182 | 1143 | 1107 | 1071 | 1032 |
*M9C96 0803BN | Y/Y1 | F09 | 1471 | 1440 | 1409 | 1377 | 1347 | 1314 | 1283 | 1247 |
High Stage Cooling Airflow Data
Model | Thermostat Call | Tap # | External Static Pressure (Inches Water Column) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
0.1 CFM | 0.2 CFM | 0.3 CFM | 0.4 CFM | 0.5 CFM | 0.6 CFM | 0.7 CFM | 0.8 CFM | |||
*M9C96 0303AN | Y2 | F01 | 753 | 708 | 663 | 616 | 568 | 513 | 470 | 423 |
*M9C96 0303AN | Y2 | F02 | 915 | 883 | 845 | 809 | 773 | 730 | 690 | 650 |
*M9C96 0303AN | Y2 | F03 | 529 | 518 | 461 | 394 | 343 | 288 | 223 | N/A |
*M9C96 0303AN | Y2 | F04 | 880 | 843 | 807 | 768 | 723 | 683 | 643 | 590 |
*M9C96 0303AN | Y2 | F05^ | 1055 | 1022 | 990 | 959 | 930 | 891 | 858 | 825 |
*M9C96 0303AN | Y2 | F06 | 1101 | 1072 | 1040 | 1010 | 980 | 949 | 918 | 881 |
*M9C96 0303AN | Y2 | F07 | 1190 | 1162 | 1134 | 1104 | 1077 | 1042 | 1013 | 982 |
*M9C96 0303AN | Y2 | F08 | 1183 | 1157 | 1130 | 1103 | 1077 | 1047 | 1018 | 988 |
*M9C96 0303AN | Y2 | F09 | 1229 | 1206 | 1178 | 1153 | 1128 | 1100 | 1070 | 1042 |
*M9C96 0403AN | Y2 | F01 | 733 | 691 | 650 | 602 | 553 | 498 | 448 | 402 |
*M9C96 0403AN | Y2 | F02 | 1051 | 1024 | 996 | 966 | 935 | 907 | 868 | 836 |
*M9C96 0403AN | Y2 | F03 | 665 | 620 | 570 | 517 | 462 | 407 | 359 | 309 |
*M9C96 0403AN | Y2 | F04 | 915 | 881 | 846 | 814 | 780 | 737 | 695 | 652 |
*M9C96 0403AN | Y2 | F05^ | 1138 | 1114 | 1092 | 1064 | 1035 | 1006 | 977 | 947 |
*M9C96 0403AN | Y2 | F06 | 887 | 855 | 823 | 790 | 751 | 705 | 666 | 608 |
*M9C96 0403AN | Y2 | F07 | 1189 | 1163 | 1138 | 1111 | 1085 | 1059 | 1032 | 1001 |
*M9C96 0403AN | Y2 | F08 | 1266 | 1243 | 1218 | 1197 | 1172 | 1148 | 1123 | 1099 |
*M9C96 0403AN | Y2 | F09 | 1342 | 1324 | 1305 | 1280 | 1263 | 1239 | 1216 | 1193 |
*M9C96 0603AN | Y2 | F01 | 900 | 867 | 830 | 798 | 758 | 718 | 682 | 645 |
*M9C96 0603AN | Y2 | F02 | 1292 | 1272 | 1248 | 1227 | 1206 | 1184 | 1162 | 1137 |
*M9C96 0603AN | Y2 | F03 | 688 | 649 | 603 | 551 | 499 | 447 | 405 | 359 |
*M9C96 0603AN | Y2 | F04 | 866 | 830 | 797 | 759 | 717 | 675 | 634 | 591 |
*M9C96 0603AN | Y2 | F05^ | 1223 | 1195 | 1176 | 1149 | 1124 | 1101 | 1074 | 1047 |
*M9C96 0603AN | Y2 | F06 | 1037 | 1004 | 975 | 950 | 921 | 886 | 853 | 823 |
*M9C96 0603AN | Y2 | F07 | 1079 | 1053 | 1025 | 1000 | 970 | 941 | 911 | 873 |
*M9C96 0603AN | Y2 | F08 | 1128 | 1099 | 1075 | 1050 | 1022 | 993 | 965 | 937 |
*M9C96 0603AN | Y2 | F09 | 1171 | 1148 | 1124 | 1096 | 1070 | 1045 | 1017 | 988 |
*M9C96 0603BN | Y2 | F01 | 914 | 864 | 815 | 762 | 704 | 654 | 604 | 560 |
*M9C96 0603BN | Y2 | F02 | 1121 | 1083 | 1041 | 996 | 953 | 906 | 861 | 818 |
*M9C96 0603BN | Y2 | F03 | 758 | 696 | 636 | 572 | 512 | 460 | 412 | N/A |
*M9C96 0603BN | Y2 | F04 | 960 | 917 | 864 | 812 | 764 | 708 | 661 | 614 |
*M9C96 0603BN | Y2 | F05^ | 1164 | 1123 | 1084 | 1042 | 1003 | 960 | 920 | 871 |
*M9C96 0603BN | Y2 | F06 | 1219 | 1180 | 1141 | 1102 | 1062 | 1020 | 978 | 940 |
*M9C96 0603BN | Y2 | F07 | 1273 | 1240 | 1207 | 1171 | 1128 | 1089 | 1051 | 1012 |
*M9C96 0603BN | Y2 | F08 | 1307 | 1270 | 1235 | 1198 | 1160 | 1122 | 1083 | 1043 |
*M9C96 0603BN | Y2 | F09 | 1427 | 1390 | 1362 | 1327 | 1297 | 1260 | 1224 | 1193 |
*M9C96 0803BN | Y2 | F01 | 1205 | 1169 | 1131 | 1091 | 1053 | 1014 | 974 | 934 |
*M9C96 0803BN | Y2 | F02 | 1415 | 1385 | 1355 | 1322 | 1291 | 1255 | 1219 | 1186 |
*M9C96 0803BN | Y2 | F03 | 696 | 635 | 568 | 500 | 442 | 390 | 336 | 255 |
*M9C96 0803BN | Y2 | F04 | 1152 | 1112 | 1076 | 1035 | 996 | 954 | 916 | 868 |
*M9C96 0803BN | Y2 | F05^ | 1321 | 1287 | 1251 | 1217 | 1181 | 1146 | 1112 | 1072 |
*M9C96 0803BN | Y2 | F06 | 901 | 851 | 801 | 746 | 690 | 638 | 587 | 543 |
*M9C96 0803BN | Y2 | F07 | 1112 | 1076 | 1032 | 992 | 949 | 905 | 858 | 819 |
*M9C96 0803BN | Y2 | F08 | 1290 | 1252 | 1215 | 1182 | 1143 | 1107 | 1071 | 1032 |
*M9C96 0803BN | Y2 | F09 | 1471 | 1440 | 1409 | 1377 | 1347 | 1314 | 1283 | 1247 |
Heating Airflow Data
Model | Thermostat Call | Tap # | External Static Pressure (Inches Water Column) | Temp Range Low | Temp Range High | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
0.1 CFM RISE | 0.2 CFM RISE | 0.3 CFM RISE | 0.4 CFM RISE | 0.5 CFM RISE | 0.6 CFM RISE | 0.7 CFM RISE | 0.8 CFM RISE | |||||
*M9C96 0303AN | W/W1 | F01^ | 753 25 | 708 26 | 663 28 | 616 30 | 568 33 | 513 | 470 | 423 | 20-50 | 20-50 |
*M9C96 0303AN | W/W1 | F03^^ | 529 N/A | 518 N/A | 461 N/A | 394 N/A | 343 N/A | 288 | 223 | N/A | 20-50 | 20-50 |
*M9C96 0303AN | W2 | F04 | 880 21 | 843 22 | 807 23 | 768 24 | 723 26 | 683 | 643 | 590 | 20-50 | 20-50 |
*M9C96 0303AN | W2 | F02^ | 915 29 | 883 30 | 845 32 | 809 33 | 773 34 | 730 | 690 | 650 | 20-50 | 20-50 |
*M9C96 0303AN | W2 | F04 | 880 30 | 843 32 | 807 33 | 768 35 | 723 37 | 683 | 643 | 590 | 20-50 | 20-50 |
*M9C96 0303AN | W2 | F05 | 1055 25 | 1022 26 | 990 27 | 959 28 | 930 29 | 891 | 858 | 825 | 20-50 | 20-50 |
*M9C96 0403AN | W/W1 | F01^ | 733 34 | 691 36 | 650 38 | 602 41 | 553 45 | 498 | 448 | 402 | 20-50 | 20-50 |
*M9C96 0403AN | W/W1 | F03^^ | 665 N/A | 620 N/A | 570 N/A | 517 N/A | 462 N/A | 407 | 359 | 309 | 20-50 | 20-50 |
*M9C96 0403AN | W2 | F04 | 915 27 | 881 28 | 846 29 | 814 31 | 780 32 | 737 | 695 | 652 | 20-50 | 20-50 |
*M9C96 0403AN | W2 | F02^ | 1051 34 | 1024 35 | 996 36 | 966 37 | 935 38 | 907 | 868 | 836 | 20-50 | 20-50 |
*M9C96 0403AN | W2 | F04 | 915 39 | 881 40 | 846 42 | 814 44 | 780 46 | 737 | 695 | 652 | 20-50 | 20-50 |
*M9C96 0403AN | W2 | F05 | 1138 31 | 1114 32 | 1092 33 | 1064 33 | 1035 34 | 1006 | 977 | 947 | 20-50 | 20-50 |
*M9C96 0603AN | W/W1 | F01^ | 900 40 | 867 42 | 830 44 | 798 46 | 758 48 | 718 | 682 | 645 | 20-50 | 30-60 |
*M9C96 0603AN | W/W1 | F03^^ | 688 N/A | 649 N/A | 603 N/A | 551 N/A | 499 N/A | 447 | 405 | 359 | 20-50 | 30-60 |
*M9C96 0603AN | W2 | F04 | 866 42 | 830 44 | 797 46 | 759 48 | 717 50 | 675 | 634 | 591 | 20-50 | 30-60 |
*M9C96 0603AN | W2 | F02^ | 1292 41 | 1272 42 | 1248 43 | 1227 43 | 1206 44 | 1184 | 1162 | 1137 | 20-50 | 30-60 |
*M9C96 0603AN | W2 | F04^^ | 866 N/A | 830 N/A | 797 N/A | 759 N/A | 717 N/A | 675 | 634 | 591 | 20-50 | 30-60 |
*M9C96 0603AN | W2 | F05 | 1223 44 | 1195 45 | 1176 45 | 1149 46 | 1124 47 | 1101 | 1074 | 1047 | 20-50 | 30-60 |
*M9C96 0603BN | W/W1 | F01^ | 914 41 | 864 43 | 815 46 | 762 49 | 704 53 | 654 | 604 | 560 | 25-55 | 35-65 |
*M9C96 0603BN | W/W1 | F03^^ | 758 N/A | 696 N/A | 636 N/A | 572 N/A | 512 N/A | 460 | 412 | N/A | 25-55 | 35-65 |
*M9C96 0603BN | W2 | F04 | 960 39 | 917 41 | 864 43 | 812 46 | 764 49 | 708 | 661 | 614 | 25-55 | 35-65 |
*M9C96 0603BN | W2 | F02^ | 1121 48 | 1083 49 | 1041 51 | 996 54 | 953 56 | 906 | 861 | 818 | 25-55 | 35-65 |
*M9C96 0603BN | W2 | F04^^ | 960 N/A | 917 N/A | 864 N/A | 812 N/A | 764 N/A | 708 | 661 | 614 | 25-55 | 35-65 |
*M9C96 0603BN | W2 | F05 | 1164 46 | 1123 47 | 1084 49 | 1042 51 | 1003 53 | 960 | 920 | 871 | 25-55 | 35-65 |
*M9C96 0803BN | W/W1 | F01^ | 1205 41 | 1169 43 | 1131 44 | 1091 46 | 1053 47 | 1014 | 974 | 934 | 35-65 | 35-65 |
*M9C96 0803BN | W/W1 | F03^^ | 696 N/A | 635 N/A | 568 N/A | 500 N/A | 442 N/A | 390 | 336 | 255 | 35-65 | 35-65 |
*M9C96 0803BN | W2 | F04 | 1152 43 | 1112 45 | 1076 46 | 1035 48 | 996 50 | 954 | 916 | 868 | 35-65 | 35-65 |
*M9C96 0803BN | W2 | F02^ | 1415 50 | 1385 51 | 1355 52 | 1322 54 | 1291 55 | 1255 | 1219 | 1186 | 35-65 | 35-65 |
*M9C96 0803BN | W2 | F04^^ | 1152 N/A | 1112 N/A | 1076 N/A | 1035 N/A | 996 N/A | 954 | 916 | 868 | 35-65 | 35-65 |
*M9C96 0803BN | W2 | F05 | 1321 54 | 1287 55 | 1251 57 | 1217 58 | 1181 60 | 1146 | 1112 | 1072 | 35-65 | 35-65 |
*M9C96 0804CN | W/W1 | F01^ | 1289 39 | 1234 40 | 1180 42 | 1122 44 | 1058 47 | 991 | 917 | 840 | 25-55 | 25-55 |
*M9C96 0804CN | W/W1 | F03 | 1297 38 | 1246 40 | 1199 42 | 1142 44 | 1083 46 | 1020 | 949 | 872 | 25-55 | 25-55 |
*M9C96 0804CN | W2 | F04 | 1194 42 | 1137 44 | 1079 46 | 1014 49 | 948 52 | 873 | 792 | 712 | 25-55 | 25-55 |
*M9C96 0804CN | W2 | F02^ | 1836 39 | 1784 40 | 1741 41 | 1703 42 | 1664 43 | 1628 | 1585 | 1537 | 25-55 | 25-55 |
*M9C96 0804CN | W2 | F04^^ | 1194 N/A | 1137 N/A | 1079 N/A | 1014 N/A | 948 N/A | 873 | 792 | 712 | 25-55 | 25-55 |
*M9C96 0804CN | W2 | F05 | 1748 41 | 1696 42 | 1650 43 | 1612 44 | 1574 45 | 1526 | 1478 | 1428 | 25-55 | 25-55 |
BTU Output vs. Temperature Rise Chart
Chart Description: This chart illustrates the relationship between BTU Output (in thousands) on the X-axis and Temperature Rise on the Y-axis. Multiple lines represent different airflow capacities (CFM) from 600 to 2400 CFM. It is used to determine furnace performance based on airflow and temperature differential.
Formulas:
- BTU/h Output = CFM x 1.08 x Rise
- Rise = BTU/H Output / (CFM x 1.08)
Wiring Diagram
Diagram Description: The wiring diagram illustrates the electrical connections for the Amana AM9C96 furnace. It shows the integration of the Integrated Control Module with components such as the Hot Surface Igniter, Pressure Switches (Low Fire, High Fire, Rollout Limit), Gas Valve, Induced Draft Blower, Circulator Blower, Transformer, and Door Switch. The diagram also includes wire color codes and status indicators for the control module. Warnings regarding high voltage and potential changes to wiring are prominently displayed.
Integrated Control Module Status Codes
Status | Seg# | Seg# | Seg# |
---|---|---|---|
Internal Faults or IRQ Loss | E | E | E |
Lockout Due to Excessive Retries Recycle | E | E | 0 |
Low Stage Pressure Switch Stuck Closed | E | 1 | |
Low Stage pressure Switch Open | E | 2 | |
Open High Limit Switch | E | E | 3 |
Flame Detected When no Flame Should be | E | 4 | |
Open Fuse | E | E | 5 |
Low Flame Signal | E | E | 6 |
Ignitor Relay Fault | E | E | L |
High Stage Pressure Switch Stuck Closed | E | E | 8 |
High Stage Pressure Switch Open | E | E | 9 |
Reversed Line Polarity or Grounding Error | E | E | A |
Internal Gas Valve Error | E | E | b |
External Gas Valve Error | E | E | C |
Open Rollout Switch | E | 1 | 1 |
Ignitor Open | E | E | N |
Inducer Relay Error | E | E | j |
TWIN Error | E | E | H |
GROUNDING ERROR | E | 1 | 0 |
Wire Color Codes
PK | PINK | EQUIPMENT GND |
BR | BROWN | FIELD GND |
WH | WHITE | FIELD SPLICE |
BL | BLUE | SWITCH (TEMP.) |
GY | GRAY | IGNITER |
RD | RED | SWITCH (PRESS.) |
YL | YELLOW | OVERCURRENT |
OR | ORANGE | PROT. DEVICE |
PU | PURPLE | JUNCTION TERMINAL |
GN | GREEN | INTERNAL TO |
BK | BLACK | INTEGRATED CONTROL |
PLUG CONNECTION | ||
LOW VOLTAGE (24V) | ||
LOW VOLTAGE FIELD | ||
HI VOLTAGE (115V) | ||
HI VOLTAGE FIELD |
Warnings: High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
Accessories
Model | Description | AM9C96 0303ANA | AM9C96 0403ANA | AM9C96 0603ANA | AM9C96 0603BNA | AM9C96 0803BNA | AM9C96 0804CNA | AM9C96 1004CNA | AM9C96 1005CNA | AM9C96 1205DNA |
---|---|---|---|---|---|---|---|---|---|---|
72950 | Concentric Vent Kit (2") | V | V | V | V | V | V | V | V | V |
72951 | Concentric Vent Kit (3") | V | V | V | V | V | V | V | V | V |
RF000142 | Drain Kit-Horizontal Left Vertical Flue | V | V | V | V | V | V | V | V | V |
EFR02 | External Filter Rack with 16"x25" Permanent Filter | V | V | V | V | V | V | V | V | V |
0170K00000S | Flush Mount Vent Kit- 3" or 2" | V | V | V | V | V | V | V | V | V |
0170K00001S | Flush Mount Vent Kit- 2" | V | V | V | V | V | V | V | V | V |
AFE18-60A | Fossil Fuel (Dual Fuel) Kit | V | V | V | V | V | V | V | V | V |
HASFK | High-Altitude Natural Gas Kit | N/A | TBD | TBD | HASFK-1 | HASFK-2 | HASFK-2 | HASFK-2 | HASFK-3 | HASFK-3 |
HASFK | High-Altitude LP Gas Kit | N/A | TBD | TBD | HASFK-1 | HASFK-2 | HASFK-2 | HASFK-2 | HASFK-2 | HASFK-2 |
0270F05404 | Horizontal Drain Tubing Kit | V | V | V | V | V | V | V | V | V |
LPLP03 | Low LP Gas Pressure Switch | V | V | V | V | V | V | V | V | V |
LPM-08 | LP Conversion Kits | V | V | V | V | V | V | V | V | V |
LPM-30 | LP Conversion Kit | V |
Notes
Amana® is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2022 Goodman Company, L.P. • Houston, Texas