inSPORTline Puhalta HT-737 Electric SUP Pump User Manual
HU
This document is the user manual for the inSPORTline Puhalta (HT-737) Electric SUP Pump.
SevenSport s.r.o. reserves the right to make changes and improvements to its products without prior notice. Visit our website: www.insportline.cz for the latest version of the manual.
Safety Instructions
- Read the manual before use and keep it for future reference.
- Do not cover the pump outlets.
- Protect from dirt, heat sources, moisture, and direct sunlight.
- Do not use if the product is worn or damaged.
- Do not pull the air hose.
- Do not use continuously for more than 20 minutes. After 20 minutes of continuous operation, let the pump cool down for at least 30 minutes.
- Never point the air hose at other people or animals.
- Do not leave unattended near children or animals.
- Do not leave unattended while operating.
- Keep away from water, rain, fire, or direct sunlight.
- Before maintenance or moving, ensure the pump is switched off.
- Check the set pressure before inflating.
- Do not use near explosive or flammable materials/gases.
- Do not use at ambient temperatures above 40°C.
- Do not repair or modify the product yourself.
- Power supply: 12 V DC car cigarette lighter.
Product Description
The pump features the following components:
- 1. Inflation Port: Where the air hose connects for inflating.
- 2. Deflation Port: Where the air hose connects for deflating.
- 3. Cigarette Lighter Power Supply: The 12V DC connector.
- 4. LED Display: Shows pressure readings and status.
- 5. BAR Button: Selects BAR as the pressure unit.
- 6. PSI Button: Selects PSI as the pressure unit.
- 7. On/Off Button: Powers the pump on and off.
- 8. Inflation: Button/function for inflating.
- 9. Deflation: Button/function for deflating.
- 10. Adapter: Various nozzle adapters for different valves.
- 11. Air Hose: The flexible tube for air transfer.
- 12. Valves: Different types of valve connectors included.
Diagram Description: The diagram shows the main unit of the electric pump with numbered ports, buttons, and a display. The air hose with an adapter and various valves are also depicted.
Usage - Inflation
Follow these steps to inflate items:
- Connect the air hose to the inflation port (1) and tighten it. (See Diagram 1)
- Attach the appropriate air valve to the other end of the hose and screw it into the item to be inflated. (See Diagram 2)
- Connect the pump to the power source (12V DC car cigarette lighter).
- Select the desired pressure unit using the BAR or PSI buttons. Use the '+' and '-' buttons to set the target pressure between 0 and 20 PSI.
- Once the target pressure is set, start inflation by pressing the On/Off button (7). During operation, you can adjust the pressure using the '+' and '-' buttons.
- To stop inflation, press the On/Off button again. The pump will automatically shut off when the set pressure is reached.
Diagram Descriptions:
Diagram 1: Illustrates the air hose being securely connected to the pump's inflation port.
Diagram 2: Shows a valve adapter being fitted onto the air hose and then screwed into an inflatable object.
Usage - Deflation
Follow these steps to deflate items:
- Connect the air hose to the deflation port (2). Tighten the hose properly. (See Diagram 3)
- Use the appropriate valve to secure it to the item you wish to deflate.
- Press the On/Off button to begin deflation.
- Press the On/Off button again to stop deflation.
- Disconnect the device from the power source.
Diagram Description:
Diagram 3: Depicts the air hose connected to the deflation port for the purpose of removing air from an object.
Specifications
Specification | Value |
---|---|
Max. Pressure | 20 PSI |
Airflow | 250(A) L/min, 70(B) L/min |
Input Voltage | DC 12V - 14.4V |
Power | 110 W |
Noise | ≤85 dB |
Package Contents
The package typically includes:
- The electric SUP pump unit.
- Air hose.
- Various valve adapters for different types of valves.
- User manual.
Visual Description: The visual shows the pump, the hose with adapters, and the manual, indicating the items included in the box.
Storage and Maintenance
Before maintenance or storage, unplug the device from the power source. Allow it to cool down before storing.
Store in a dry, shaded, and well-ventilated area.
Troubleshooting
Problem | Possible Cause | Solution |
---|---|---|
Cannot Start | Incorrect connection | Ensure it is properly connected to the 12V DC power supply. |
Blown fuse | Replace the fuse. | |
Low Pressure | Overheating or overload | Let the pump cool down. |
Blocked connections (ports or hose) | Check that the connections are not blocked. | |
E3 | Blocked air hose or valve | Check the connections. |
Air leak | Check for air leaks. | |
U-L | Low voltage (below 10.5 V) | Ensure proper connection. |
U-H | High voltage (above 17 V) | Ensure proper connection. |
Overheating | Overheating protection | Let the pump cool down. |
LO/HI E6 | Overload protection | Check for debris in the vents. |
Set pressure does not reset to default. | Reset value | Press and hold the PSI button for 3 seconds. |
Environmental Protection
After the product's lifespan, or if repair is uneconomical, dispose of it in an environmentally friendly manner according to local laws at the nearest collection point.
This helps protect the environment and natural resources, and contributes to the protection of human health. If you are unsure about the correct disposal of waste, seek information from local authorities to avoid violating laws or facing penalties.
Do not dispose of batteries with household waste; take them to a recycling facility.