Loctite CL10 Single LED Controller

EQUIPMENT Operation Manual

Item No. 1514636

2 Overview

The Loctite CL10 Single LED Controller is a UV light source designed to emit a spot of light at wavelengths of 365nm or 405nm. It is utilized in adhesive Light Cure bonding applications.

Advantages:

  • Over 20,000 working hours.
  • No IR emission, resulting in low-temperature curing and preventing damage to parts from heat emission.
  • Up to 90% energy savings compared to mercury arc lamps.
  • Compact LED head suitable for handheld or fixed fixture applications.
  • Operates via foot switch actuation or PLC remote control.
  • Supports timed mode or manual cycling.
  • Low maintenance cost.

3 Technical Data

Type LOCTITE® CL10 Single LED Controller
Timer Mode Intensity: 0~100%, Timer: 0.1~999.9s
Manual Mode Intensity (0~100%), Timer: Manual Control
Power Supply AC 100~240V 50/60Hz
Power Consumption 15W
Cooling Method Natural Cooling
Temperature Range Operating: +5~40°C, Storage: -15~+65°C
Weight 0.6Kg
Wavelength 365nm, 405nm

4 Installation

Please check the unit for any mechanical defects. If shipping damage is present, do not install or use the equipment and immediately contact the shipping company and supplier.

4.1 Capacity

Diagram showing minimum space required for the equipment: a box representing the controller with 50mm clearance on the sides and 30mm clearance above and below.

4.2 Dimension

Diagram showing the dimensions of the Loctite CL10 Single LED Controller. The main unit is approximately 62.0mm (2.44 inches) wide and 150.0mm (5.91 inches) high. A side view shows a depth of 64.0mm (2.52 inches). The front panel features a display showing 'Intensity % 100' and 'Time S 20.0', with SET and arrow buttons below. It also indicates the item number 1514636.

4.3 Caution

  • To prevent heat damage, position the unit horizontally on a level surface. Improper positioning may cause damage.
  • Avoid placing the unit next to high voltage equipment or heat sources.
  • Ensure no objects are placed on the power cable.

4.4 Installation Flow

  1. Place the controller horizontally on a level surface.
  2. Connect the power cable to the controller using the supplied power cable. The power connector is labeled 'XS-1' and indicates AC 100-240V 50/60Hz with a fuse rating of 2AMP 250VAC.
  3. Connect the LED head to the connector labeled '' located under the power button.
  4. Caution: Press the power switch to turn on the LED head; press again to turn off. When using a PLC or extension cable, a '0V' indication means the LED head is working.
  5. Connect the foot switch or PLC (optional) to the connector labeled ''.

5 Controller Button and Operating

5.1 Component Name and Function

Diagram of the controller front and rear panels with numbered components:

  • 1. Power Switch: Turns the unit On/Off.
  • 2. LED Head Connector: Port for connecting the LED head.
  • 3. Intensity Display: Shows intensity setting data, easy to read and edit.
  • 4. Time Display: Shows time setting data, easy to read and edit.
  • 5. Up Arrow Button: Used for adjusting settings.
  • 6. SET Button: Confirms selections or enters menus.
  • 7. Down Arrow Button: Used for adjusting settings.
  • 8. Power Cable Connector: Port for the AC power cable.
  • 9. Control Port (XS-1): Input for LED head control signals (e.g., from foot switch or PLC).

The rear panel shows the 'XS-1' control port and the 'AC 100-240V 50/60Hz FUSE:2AMP 250VAC' power connector.

5.2 Button and Display Instruction

5.2.1 Button Instruction

  • Power Switch: Power On/Off.
  • Arrow Buttons (Up/Down): Edit settings.
  • SET Button: Confirm or enter menu.

5.2.2 Display Instruction

  • Intensity %: Displays intensity data information.
  • Time S: Displays time data information.

5.3 Operating

5.3.1 Startup

Warning:
  • Place the equipment in a stable space.
  • Avoid placing near high voltage machinery.
  • Do not block ventilation holes.
  • Do not expose to flammable gas.
  • Avoid high temperatures or extreme cold.
  • To prevent electric shock, disconnect equipment from the electrical supply before servicing.
Caution:
  • To prevent button damage, do not press buttons with excessive force.
  • Prevent metallic foreign matter from entering the LED head connector, as it may cause shorts, damage, and fire.
  • Do not connect any non-LED head cable to the connector; this may cause errors and damage.

5.3.2 Starting Controller

After installation, plug in the power cable and press the Power button. The red LED indicator light inside the power button will illuminate when the unit is powered.

5.3.3 Working Mode

Once the LED head is plugged in, the controller automatically enters Working Mode.

Caution: All settings should be adjusted while in working mode.

5.4 Parameter Setting

5.4.1 Intensity Setting

  1. Enter working mode.
  2. Press and hold the Up arrow button [▲] to set intensity. The intensity data will flash when the button is pressed and stop flashing when released.
  3. Use the Up arrow [▲] or Down arrow [▼] button to adjust the intensity.
  4. Press the SET button twice to confirm and save the setting.

5.4.2 Time Setting

  1. Enter working mode.
  2. Press and hold the Down arrow button [▼] to edit the time. The time data will flash.
  3. Use the Up arrow [▲] or Down arrow [▼] button to change the time value.
  4. Press the SET button to confirm and move to the next setting unit.
  5. Press the SET button twice to confirm and save when finished with the last setting.

5.5 Working Mode Setting

In Working Mode, you can switch between Manual and Timer modes by holding the SET button. In Timed Mode, the set time is displayed. In Manual mode, 'oFF' is displayed under 'Time S'.

5.6 Working Temperature

Press the SET button once while in working mode to display the temperature of the LED head.

Caution:
  • When both Intensity and Time data are flashing, pressing either arrow button allows adjustment of either intensity or time, depending on which arrow is pressed.
  • The foot switch functions only in working mode.
  • The controller automatically enters working mode if left idle in setting mode for 60 seconds.

5.7 LED Head Unit and Foot Switch

Warning:
  • Properly measure and define the working distance before using the LED head.
  • Do not touch the LED tip during use, as high temperatures can cause injury.

Diagram showing a foot switch connected to the controller. Pressing the foot switch activates the LED head according to the set parameters.

6 Shutdown

Step 1: Press the Power button to turn off the controller. The red indicator light will turn off simultaneously.

Step 2: Disconnect the power cable.

Diagrams illustrate the Power button on the front panel and the rear panel connectors (XS-1 and power input) for shutdown procedures.

7 Troubleshooting

Error Cause/Demonstration Action
Display not on when turning on power button Please check if power cable is plugged in properly. Plug in power cable properly.
Cannot set parameter Please check the fuse. LED head is not in working status. LED head is not plugged in properly. Fuse type: 2AMP, 250VAC. Exit working status, enter settings. Plug in LED properly.
LED head working abnormally. Please check if equipment is working in your required mode. Go to parameters and set mode as you want.
No UV output when clicking foot switch. Controller is not in working mode. Make sure controller is in working mode.
LED head cannot connect with channel's connector. Please check alignment of the groove on the main unit and red point on the LED head. Please check item 3, chapter 4.4.
Time shown on LCD has timed out, but the LED head is still working. Please check if controller is in manual mode. Set to Time mode.
LED head cannot reach setting intensity when working. Please check the working distance. Set the working distance properly.

8 Replacement Parts

Name Loctite® Item No.
Controller CL10 Single LED Controller 1514636
CL10 LED Head, 365nm, 6mm, w/2.7m cable 1538499
CL10 LED Head, 405nm, 6mm, w/2.7m cable 1746633
Spare Parts
Lens: CL10 Lens for 365nm, 6mm LED Head 1538496
Lens: CL10 Lens for 405nm, 6mm LED Head 1750074
Foot Switch: Foot Switch Assembly 97201
Optional Accessories
EQ PM20 UV VIS Radiometer (item # 2436352) 1265282
EQ PM20 UV AB Radiometer (item # 2436353) 1390323
Tip Locator for CL10 LED Spot Cure Heads 1403402

9 WARRANTY

Henkel expressly warrants that all products referred to in this Instruction Manual for Loctite® CL10 Single LED Controller (hereafter called “Products”) shall be free from defects in materials and workmanship. Liability for Henkel shall be limited, as its option, to replacing those Products which are shown to be defective in either materials or workmanship or to credit the purchaser the amount of the purchase price thereof (plus freight and insurance charges paid therefore by the user). The purchaser’s sole and exclusive remedy for breach of warranty shall be such replacement or credit.

A claim of defect in materials or workmanship in any Products shall be allowed only when it is submitted in writing within one month after discovery of the defect or after the time the defect should reasonably have been discovered and in any event, within (12) months after the delivery of the Products to the purchaser. This warranty does not apply to perishable items, such as (indicate items: fuses, filters, lights, etc.). No such claim shall be allowed in respect of products which have been neglected or improperly stored, transported, handled, installed, connected, operated, used or maintained. In the event of unauthorized modification of the Products including, where products, parts or attachments for use in connection with the Products are available from Henkel, the use of products, parts or attachments which are not manufactured by Henkel, no claim shall be allowed.

No Products shall be returned to Henkel for any reason without prior written approval from Henkel. Products shall be returned freight prepaid, in accordance with instructions from Henkel.

NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED, MISUSED, NEGLECTED, OR DAMAGED BY ACCIDENT.

EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION, HENKEL MAKES NO WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCTS.

ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND OTHER WARRANTIES OF WHATEVER KIND (INCLUDING AGAINST PATENT OR TRADEMARK INFRINGEMENT) ARE HEREBY DISCLAIMED BY HENKEL AND WAIVED BY THE PURCHASER.

THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS.

WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS, HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF, OR OTHERWISE IN CONNECTION WITH, THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS AND SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER CAUSED BY NEGLIGENCE FROM HENKEL OR OTHERWISE.

Models: 1514636, CL10, Single LED Controller, CL10 Single LED Controller, 1514636 Single LED Controller, 1514636 CL10 Single LED Controller

File Info : application/pdf, 16 Pages, 652.60KB

PDF preview unavailable. Download the PDF instead.

loctite cl10 single led controller manual

References

Microsoft Word for Microsoft 365

Related Documents

Preview Loctite Cure Jet & 7700-HD Robot Mounting Bracket Kit (1034030)
This document provides details for the Loctite 1034030 mounting bracket kit, designed for the Cure Jet and 7700-HD LED light sources used with Loctite 3-axis robots. It includes product description, installation instructions, and a list of required and optional accessories for robotic dispensing systems.
Preview LOCTITE SI 5300 Technical Data Sheet
Technical data sheet for LOCTITE SI 5300, a silicone sealant and adhesive offering high temperature resistance, used in industrial bonding and sealing applications.
Preview Loctite Do It Right Users' Guide: Comprehensive Maintenance Product Instructions
Discover the Loctite 'Do It Right' Users' Guide, offering detailed instructions and selection advice for Loctite maintenance products, including threadlockers, sealants, and adhesives, to enhance industrial repair and equipment longevity.
Preview LOCTITE LB 8034 High Performance Synthetic Grease Technical Data Sheet
Technical data sheet for LOCTITE LB 8034 High Performance Synthetic Grease, detailing its properties, applications, compatibility, and usage instructions. This NLGI Grade 2 grease is a multi-purpose lubricant suitable for industrial processes and food processing equipment.
Preview LOCTITE TITE FOAM Multi-Purpose Insulating Foam Sealant Technical Data Sheet
Technical data sheet for LOCTITE TITE FOAM Multi-Purpose Insulating Foam Sealant, detailing its properties, application, safety, and storage.
Preview LOCTITE 480 Sicherheitsdatenblatt: Gefahren, Handhabung und Lagerung
Umfassendes Sicherheitsdatenblatt für LOCTITE 480 Cyanacrylat-Klebstoff von Henkel, einschließlich Gefahrenhinweise, Erste-Hilfe-Maßnahmen, Expositionsparameter und Entsorgungsinformationen.
Preview Scheda di Dati di Sicurezza per LOCTITE 3090
Informazioni complete sulla sicurezza, manipolazione e smaltimento del prodotto adesivo LOCTITE 3090, in conformità con il Regolamento (CE) Nr 1907/2006.
Preview Loctite SF 7840 #693-797, 693-804 (NZ) - Safety Data Sheet
Safety Data Sheet for Loctite SF 7840 #693-797, 693-804 (NZ), a cleaner. Provides comprehensive information on identification, hazards, composition, first aid, firefighting, handling, storage, exposure controls, physical properties, stability, toxicology, ecological information, disposal, transport, and regulatory status.