Introduction
This document serves as a comprehensive technical manual for the Metra Wristband Capturer, MEW edition. It details the product's features, specifications, and operational guidelines. The Metra Wristband Capturer is a retaining module designed for Metra RFID wristbands, integrating seamlessly with various Metra MEW products like Tripod Turnstiles and Turnstile Access Terminals. Its innovative ticket retain feature allows for the reuse of tickets, significantly reducing system operation costs and the potential for fraud. The device supports ISO 15693, ISO 14443A, ISO 14443B, and Mifare compatible RFID media, granting an exit signal only when a ticket is successfully erased and retained.
Key Features and Functionality
- Product Description: A retaining module for Metra RFID wristbands, integrated into Metra MEW products.
- Ticket Retain Feature: Enables reuse of tickets, patented in 1998, working with contactless RFID wristbands.
- RFID Compatibility: Reads ISO 15693, ISO 14443A, ISO 14443B, and Mifare compatible RFID media.
- Signalization: Features a BLUE LED for normal operation, short beep, and direction light. RED LED blinking and acoustic signal indicate denied access or errors.
- DIP Switch Settings: Allows for configuration of special modes like TEST mode, silicone wristband operation, debug messages, and automatic capturing.
- Mounting: Includes detailed instructions for secure installation.
Technical Specifications
- Operating Voltage: 24V DC regulated
- Operating Temperature Range: -10 °C to +50 °C
- Operating Relative Humidity Range: 20% to 80% (non-condensing)
- Audio Signal: Integrated piezoelectric beeper
- Visual Signalization: Metra logo on the front panel
- Network Type: MEW (LIN)
- Dimensions: 147/75/230 mm (w/h/l)
Regulatory Information
The Metra Wristband Capturer complies with essential EU Directives, including RoHS2 and the EMC Directive. It also adheres to FCC Rules, ensuring it does not cause harmful interference. For detailed information on compliance and disposal, please refer to the full technical manual.
Further Information
For more details on connections, control device integration, and specific operational modes, consult the relevant sections of this manual. For assistance or inquiries, please visit www.metra.si.