Snooker Ice Maker
Product Model Number
SK-219S / SK-219H / SK-219U
Electrical Requirements
[electrical symbol] A 115 Volt, 60 Hz., AC only, 15- or 20-amp electrical supply, properly grounded in accordance with the National Electrical Code and local codes and ordinances, is required. It is recommended that a separate circuit, serving only your ice maker, be provided. Use a receptacle which cannot be turned off by a switch or pull by chain.
Water Supply
[water drop symbol] A cold water supply with water pressure between 0.13 Mpa [19 psi] and 0.55 Mpa [80 psi] is required to operate the ice maker. If you have questions about your water pressure, call a licensed, qualified plumber.
Location Requirements
To ensure proper ventilation for your ice maker, the front side must be completely unobstructed. The ice maker may be closed-in on the top and two sides, but the installation should allow the ice maker to be pulled forward for servicing if necessary.
Installation of the ice maker requires a cold water supply inlet of 3/8" (6.35 mm) OD soft copper tubing with a shutoff valve or drain pump, only to carry the water to an existing drain.
Choose a well-ventilated area with temperatures above 55°F (13°C) and below 110°F (43°C). Best results are obtained between 70°F and 90°F (21°C and 32°C).
Unit Dimensions
The following dimensions are for planning purposes only.
Front View: Width: 26 inches
Side View: Depth: 27 inches
Overall Height: 36.5 inches
Cube Sizes:
- Full cube size: 7/8"x7/8"x7/8"
- Half cube size: 7/8" x7/8" x5/8"
Refrigerant: R290
Drain Connection
Gravity Drain System
Connect the ice maker drain to your drain in accordance with all state and local codes and ordinances. If the ice maker is provided with a gravity drain system, follow these guidelines when installing drain lines. This will help keep water from flowing back into the ice maker storage bin and potentially flowing onto the floor, causing water damage.
- Drain lines must have a minimum of 5/8" (15.88 mm) inside diameter.
- Drain lines must have a 1" drop per 48" (2.54 cm drop per 122 cm) of run or 1/4" drop per 12" (6.35 mm per 30.48 cm) of run and must not have low points where water can settle.
- The floor drains must be large enough to accommodate drainage from all drains.
- The ideal installation has a standpipe with a 1 1/2" (3.81 cm) to 2" (5.08 cm) PVC drain reducer installed directly below the outlet of the drain tube. You must maintain a 1" (2.54 cm) air gap between the drain hose and the standpipe.
Important Notes
IMPORTANT: A drain pump is necessary when a floor drain is not available.
IMPORTANT: Follow Plumbing Code and any local codes and ordinances.
The drain pump discharge line must terminate at an open sited drain.
- Maximum rise: 10 ft (3.1 m)
- Maximum run: 100 ft (30.5 m)
Notes
- If the drain hose becomes twisted and water cannot drain, your ice maker will not work.
This product is certified by ETL Sanitation Listed and ENERGY STAR.
At Snooker's, our policy includes a continuous commitment to improve our products; we reserve the right to change materials and specifications without notice.