8 giorni fa — LOCATION. To ensure proper ventilation for your ice maker, the front side must be completely unobstructed. The ice maker may be.
1000-lb Flip-up Door Freestanding/Built-In For Commercial Use Cubed Ice Maker (Stainless Steel) 0850003682006
MODULAR ICEMAKER PRODUCT MODEL NUMBER SK-1000P Full cube size 7/8"x7/8"x7/8" Refrigerant R404A ELECTRICAL A 220 Volt, 60 Hz., AC only, electrical supply, properly grounded in accordance with the National Electrical Code and local codes and ordinances, is required. Use a separate circuit, serving only your ice maker. WATER A cold water supply with water pressure between 0.13 Mpa [19 PSI] and 0.55 Mpa [80 PSI] is required to operate ice maker. If you have questions about your water pressure, call a licensed, qualified plumber. LOCATION To ensure proper ventilation for your ice maker, the front side must be completely unobstructed. The ice maker may be closed-in on the top and two sides with proper spacing left for ventilation. The installation should allow the ice maker to be pulled forward for servicing if necessary. Installation of the ice maker requires a cold water supply inlet of 3/8" (6.35 mm) OD soft copper tubing with a shutoff valve or drain pump, only to carry the water to an existing drain. Choose a well ventilated area with temperatures above 55°F (13°C) and below 110°F (43°C). Best results are obtained between 70°F and 90°F (21°C and 32°C). ICE MAKER UNIT DIMENSIONS 23 30 E W 23 D 46 32 22 Dimensions (WDH) Output C Ice Shape 30x33x66 1000lb /317kg Full Dice Bin size 350 lb Voltage Watts O Condenser unit 220(V) 2300(W) Air Refrigerant R404A Net weight of head 145lb Net weight of bin Gross weight of head Gross weight of bin 100lb 155lb 110lb Carton dimensions of head 34x28x25 Carton dimensions of Bin 36x34x42 Check that the power supply cord is not damaged, or pinched or kinked between the ice maker and the cabinet. Check that the water supply line is not damaged, or pinched or kinked between the ice maker and the cabinet. Check that the drain line is not damaged, or pinched or kinked between the ice maker and the cabinet. Choose a location where the floor is even. It is important for the ice maker to be level in order to work properly. If needed, you can adjust the height of the ice maker by changing the height of the leveling legs. DRAIN CONNECTION GRAVITY DRAIN SYSTEM Connect the ice maker drain to your drain in accordance with all state and local codes and ordinances. If the ice maker is provided with a gravity drain system, follow these guidelines when installing drain lines. This will help keep water from flowing back into the ice maker storage bin and potentially flowing onto the floor, causing water damage. Drain lines must have a minimum of 5/8" (15.88 mm) inside diameter. Drain lines must have a 1" drop per 48" (2.54 cm drop per 122 cm) of run or 1/4" drop per 12" (6.35 mm per 30.48 cm) of run and must not have low points where water can settle. The floor drains must be large enough to accommodate drainage from all drains. The ideal installation has a standpipe with a 11/2" (3.81 cm) to 2" (5.08 cm) PVC drain reducer installed directly below the outlet of the drain tube as shown. You must maintain a 1" (2.54 cm) air gap between the drain hose and the standpipe. IMPORTANT A drain pump is necessary when a floor drain is not available. Plumbing Code and any local codes and ordinances. The drain pump discharge line must terminate at an open sited drain. Maximum rise 10 ft (3.1 m) Maximum run 100 ft (30.5 m) NOTES If the drain hose becomes twisted and water cannot drain, your ice maker will not work. It may be desirable to insulate the drain line thoroughly up to the drain inlet. At Snooker's our policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.Microsoft Word 2016