DAB E.SWIM Epro Pump Quick Guide
Your essential guide to setting up and operating the DAB E.SWIM Epro pump.
Introduction
This document provides a quick guide for the installation and operation of the DAB E.SWIM Epro pump. It covers the setup wizard, manual operation, and important features.
Installation Overview
The installation process involves connecting the pump to your plumbing system and power supply. Ensure the pump is installed in a suitable environment, respecting the maximum temperature limits of 50°C (122°F) for the pump body and 40°C (104°F) for the surrounding air. The pump can handle water up to a maximum head of 4 meters (13 feet).
Step 1: Connect inlet and outlet pipes to the pump. [See diagram: Person in safety gear connecting hoses to a pump.]
Step 2: Ensure the pump is correctly integrated into the water circulation system, with water flowing through it. [See diagram: Pump installed in a plumbing system showing water flow.]
Step 3: Verify secure connections for both water inlet and outlet. [See diagram: Pump with water inlet and outlet pipes.]
Step 4: Connect the pump to a stable power source and the control unit. A warning symbol [⚠️] indicates the importance of correct electrical connections. [See diagram: Pump connected to power and control unit.]
Setup Wizard
The pump features a user-friendly setup wizard to configure its basic parameters:
- Languages: Select your preferred language from the available options (e.g., English, Español, Italiano). [See screen: Language selection interface with options.]
- Time Mode: Choose between 24-hour or 12-hour (am/pm) time format. [See screen: Time mode selection interface.]
- Time Set: Set the current time (e.g., 12:00 pm). [See screen: Time setting interface.]
- Day Set: Select the current day of the week (e.g., Sunday, Monday). [See screen: Day selection interface.]
- Head Unit: Choose the unit for displaying head pressure: meters (m) or feet (ft). [See screen: Head unit selection interface.]
- Flow Unit: Select the unit for displaying flow rate: cubic meters per hour (m³/h) or US gallons per minute (US gpm). [See screen: Flow unit selection interface.]
- Temperature Unit: Choose the unit for temperature display: Celsius (°C) or Fahrenheit (°F). [See screen: Temperature unit selection interface.]
- Control Mode: Configure the pump's operating mode, such as Speed (%) or Flow (US gpm). A graph illustrates the relationship between speed and flow. [See screen: Control mode selection interface and graph.]
- Head Limit: Set the maximum head limit (Hmax) for the pump's operation, visualized on a Head vs. Flow graph. [See graph: Head (H) vs. Flow (Q) graph with Hmax line.]
- Flow Limit: Set the maximum flow limit (Qmax) for the pump's operation, visualized on a Head vs. Flow graph. [See graph: Head (H) vs. Flow (Q) graph with Qmax line.]
- Complete: The wizard confirms that all settings have been applied. [See screen: Setup complete confirmation.]
Manual Operation
The pump can be operated manually using the control panel. You can turn the pump ON [ON] or OFF [OFF] directly. [See control panel: Manual mode buttons.]
Timers Daily Summary: Configure daily operating schedules using the timer function. [See graphic: Daily timer summary showing scheduled ON/OFF times.]
External Control: The pump supports external control signals via 4-20mA or 0-10V inputs.
Operation States: The pump can be set to ON [ON] or OFF [OFF] states, indicated on the control panel. [See indicators: Pump ON/OFF states.]
Key Features
Priming: The pump includes a priming function to ensure proper operation. Follow the steps to run priming, which involves setting speed, duration, and monitoring performance metrics like RPM and power consumption. [See diagram: Priming process steps.]
Anti-Freeze: This feature helps protect the pump from freezing by automatically activating it at low temperatures. You can enable Anti-Freeze and set the desired temperature range (e.g., 4°C to 10°C). [See settings: Anti-Freeze enable and temperature range.]
Anti-Lock: The Anti-Lock feature prevents the pump from seizing up during periods of inactivity by running it periodically. You can enable this function. [See settings: Anti-Lock enable.]
Operation Modes: The pump can operate in various modes (e.g., 1° through 7°), each with specific ON/OFF configurations. [See indicators: Different operation modes with ON/OFF status.]
Troubleshooting (FAQ)
Refer to the following common issues and their solutions:
- FAQ 1: Low Water Level: If the pump is not adequately submerged, it may not operate correctly. Ensure the water level is sufficient. [See diagram: Pump with low water level warning [⚠️].]
- FAQ 2: Wiring Issues: Incorrect electrical connections can cause operational problems. Verify that all wiring is done according to the manual and safety standards. [See diagram: Incorrect pump wiring with warning [⚠️].]
- FAQ 3: Dry Running: Operating the pump without water can damage it. Check for conditions that might cause the pump to run dry and address them. [See diagram: Pump running dry warning [⚠️].]
- FAQ 4: Pump Fault: If the pump shows a fault or warning, it may indicate an internal issue or overheating. Consult further documentation or support if problems persist. [See diagram: Pump fault warning [⚠️].]
- FAQ 5: Operational Parameters: Ensure the pump is operating within its specified Head and Flow limits. Deviations may lead to inefficient performance. [See diagrams: Graphs showing incorrect Head vs. Flow parameters with warnings [⚠️].]
Contact Information
For support and inquiries, please contact the relevant DAB PUMPS branch:
- DAB PUMPS LTD. (UK): Units 4 and 5, Stortford Hall Industrial Park, Dunmow Road, Bishop's Stortford, Herts CM23 5GZ. Email: salesuk@dwtgroup.com. Phone: +44 1279 652 776. Fax: +44 1279 657 727.
- DAB PUMPS IBERICA S.L. (Spain): Avenida de Castilla nr.1 Local 14, 28830 - San Fernando De Henares - Madrid. Email: info.spain@dwtgroup.com. Phone: +34 91 6569545. Fax: +34 91 6569676.
- DAB PUMPS B.V. (Belgium): Brusselstraat 150 B-1702 Groot-Bijgaarden. Email: info.belgium@dwtgroup.com. Phone: +32 2 4668353. Fax: +32 2 4669218.
- DAB PUMPS B.V. (Netherlands): Albert Einsteinweg, 4, 5151 DL Drunen. Email: info.nl@dwtgroup.com. Phone: +31 416 387280. Fax: +31 416 387299.
- DAB PUMPS INC. (USA): 3226 Benchmark Drive Ladson, SC 29456. Email: info.usa@dwtgroup.com. Phone: 1-843-797-5002. Fax: 1-843-797-3366.
- DWT South Africa: Podium at Menlyn, 3rd Floor, Unit 3001b, 43 Ingersol Road, C/O Lois and Atterbury, Menlyn, Pretoria, 0181. Email: info.sa@dwtgroup.com. Phone: +27 12 361 3997. Fax: +27 12 361 3137.
- OOO DAB PUMPS (Russia): Novgorodskaya str, 1, bld G, office 308 127247 Moscow. Email: info.dwtru@dwtgroup.com. Phone: +7 495 122 00 35. Fax: +7 495 122 00 36.
- DAB PUMPEN DEUTSCHLAND GmbH (Germany): Tackweg 11 D-47918 Tönisvorst. Email: info.germany@dwtgroup.com. Phone: +49 2151 82136-0. Fax: +49 2151 82136-36.
- DAB PUMPS POLAND SP. Z.O.O. (Poland): Mokotow Marynarska Ul. Postepu 15c 02-676 Warsaw. Phone: +48 223 81 6085.
- DAB UKRAINE: Representative Office Regus Horizon Park 4M. Hrinchenka St, suit 147, 03680 Kiev. Email: info.ukraine@dwtgroup.com. Phone: +380 44 3195943.
- DAB PUMPS CHINA: No.40 Kaituo Road, Qingdao Economic & Technological Development Zone Qingdao City, Shandong Province, China PC: 266500. Email: info.china@dwtgroup.com. Phone: +8653286812030-6270. Fax: +8653286812210.
- DAB PRODUCTION HUNGARY KFT.: H-8800 NAGYKANIZSA, Buda Ernó u.5 HUNGARY. Phone: +36.93501700.
- DAB PUMPS DE MÉXICO, S.A. DE C.V.: Av Gral Álvaro Obregón 270, officina 355 Hipódromo, Cuauhtémoc 06100 México, D.F. Phone: +52 55 6719 0493.
- DAB PUMPS S.p.A. (Italy - Headquarters): Via M. Polo, 14 - 35035 Mestrino (PD). Phone: +39 049 5125000. Fax: +39 049 5125950. Website: www.dabpumps.com.