DAB

WATER TECHNOLOGY

NOVA 4100

OWNER'S MANUAL

Declaration of Conformity

DAB Pumps S.p.A. declares that the products to which this declaration refers are in conformity with the following directives:

And with the following standards:

Mestrino (PD), 01/01/2013

FRANCESCO SINICO
TECHNICAL DIRECTOR

1. Safety Measures

Warning: Before starting the pump, read this instruction booklet carefully.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

Important: A 10mA or 30mA Residual Current Device (GFI) MUST be fitted to the mains supply of the pump only.

The power cord must never be used to carry or move the pump. Always use the pump's handle.

Note: Before taking any action on the pump, always remove the plug from the power socket. Never remove the plug by pulling on the power cord. If the power supply cord has been damaged, it must be replaced by the manufacturer or his authorized customer support service in order to avoid all risks.

Overload Protection

The pump has a thermal overload safety device. In the event of any overheating of the motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically comes on again. If the overload cutout is tripped, it is essential to identify and deal with the cause of the overheating. See Troubleshooting.

2. Use

Multi-purpose submersible pumps with a high degree of reliability and safety designed to circulate water in garden ponds, create water falls and play water features.

Designed to work in both horizontal and vertical installations.

NOVA 4100 models are suitable to pump clean water, without fibres and with particles with maximum diameter of 0.393" (10 mm).

The temperature of the fluid being pumped must never exceed 95°F (35°C).

Warning: The pump must not be used to pump salty water, sewage, flammable, corrosive or explosive liquids (e.g. petrol, fuel, diluents), greases, oils or foodstuffs.

Important: Before starting the pump, make sure that:

Note: Given the different provisions applicable to the safety of electric systems in different countries, make sure that the pump system, as concerns its intended use, is in accordance with current local or state legislation.

3. Starting the Pump

Insert the plug on the power cord in a suitable power socket.

Start the pump. 20 times per hour Max.

4. Recommendations

To ensure the proper operation of the pump, it is important to comply with the following recommendations:

To clean the water intake chamber:

  1. Unscrew the four screws from the bottom plate (pos. 1) from the main body (pos. 2).
  2. Thoroughly flush the inner cavity and impeller with clean water.
  3. Refit the base taking care not to damage the o-ring.

5. Technical Data

MODEL POWER INPUT 60 Hz P1 Max P2 In Max Submersion
HP W HP W A
NOVA 4100 1 x 115~ 0.9 670 0.5 380 7.1 22 ft
NOVA 4100 1 x 230~ 0.9 670 0.5 380 3.2 22 ft
MODEL A B H DNM GAS PACKING DIMENSIONS L B H CABLE LENGHT WEIGHT lbs
NOVA 4100 16' 5.512 6.102 12.795 1" 1/4 7.598 7.598 14.764 16 ft 14.8
NOVA 4100 100' 5.512 6.102 12.795 1" 1/4 7.598 7.598 14.764 100 ft 15.9

6. Guarantee

Any material or manufacturing defects will be corrected during the guarantee period established by current law in the country where the product is purchased. It is up to the manufacturer to decide whether to repair or replace any faulty parts.

The manufacturer's guarantee covers all substantial defects attributable to manufacturing or material defects, providing the product has been used correctly and in compliance with the instructions.

The guarantee becomes null and void in the event of the following:

The guarantee does not cover parts liable to rapid wear and tear.

For any action under guarantee, contact an authorized customer support service, presenting your receipt for the purchase of the product.

DAB PUMPS INC
3226 Benchmark Drive,
Ladson South Carolina 29456 – U.S.A.
Ph. 1-843-797-5002
Fax 1-843-797-3366
www.dabpumps.us

7. Troubleshooting

Overload Protection: The pump has a thermal overload safety device. In the event of any overheating of the motor, this device automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically comes on again. If the overload cutout is tripped, it is essential to identify and deal with the cause of the overheating. See Troubleshooting.

Fault Possible Causes Solutions
The pump does not run. Power cord unplugged.
Impeller jammed.
Water level under the suction minimum.
Plug cord securely into the socket and check if there is voltage on the line.
Disconnect the power cord, disassemble hydraulic part and check if impeller is free to run.
Stop the pump. Reposition pump to ensure pump is always fully submerged.
Suction filter clogged. Air bubble in the pump, produced during the plunge.
Suction filter clogged.
Discharge tube clogged or obstructed.
Get the air out by plunging again the pump while in a tilted position and shake it with the discharge tube open.
Disconnect the power cord, clean the hydraulic part.
Disconnect the power cord: take off the tube and clean it.
Suction filter clogged. The thermal overload protection in the pump has activated.
Water Temperature exceeds 95°F.
The pump ran dry.
Clean water intake area. Allow pump to cool for approximately 30 minutes.
Maximum water temperature must not exceed 95°F.
Reposition pump to ensure pump is always fully submerged.

DAB PUMPS Selector

On-line selection tool

DAB PUMPS LTD.
Unit 4 and 5, Stortford Hall Industrial Park, Dunmow Road, Bishops Stortford, Herts CM23 5GZ - UK
salesuk@dwtgroup.com
Tel. +44 1279 652 776
Fax +44 1279 657 727

DAB PUMPS IBERICA S.L.
Avenida de Castilla nr.1 Local 14 28830 - San Fernando De Henares - Madrid Spain
info.spain@dwtgroup.com
Tel. +34 91 6569545
Fax: +34 91 6569676

DAB PUMPS B.V.
Brusselstraat 150 B-1702 Groot-Bijgaarden - Belgium
info.belgium@dwtgroup.com
Tel. +32 2 4668353
Fax +32 2 4669218

DAB PUMPS INC.
3226 Benchmark Drive Ladson, SC 29456 - USA
info.usa@dwtgroup.com
Tel. 1-843-797-5002
Fax 1-843-797-3366

DAB PRODUCTION HUNGARY KFT.
H-8800 Nagykanizsa, Buda Ernó u.5 Hungary
Tel. +36 93501700

DAB PUMPS POLAND Sp. z 0.0.
Mokotow Marynarska ul. Postępu 15C 02-676 Warszawa - Poland
Tel. +48 223 81 6085

DWT SOUTH AFRICA
Podium at Menlyn, 3rd Floor, Unit 3001b, 43 Ingersol Road, C/O Lois and Atterbury street, Menlyn, Pretoria, 0181 - South-Africa
info.sa@dwtgroup.com
Tel. +27 12 361 3997
Fax +27 12 361 3137

DAB PUMPS B.V.
Albert Einsteinweg, 4 5151 DL Drunen - Nederland
info.netherlands@dwtgroup.com
Tel. +31 416 387280
Fax +31 416 387299

DAB UKRAINE Representative Office
Regus Horizon Park 4 M. Hrinchenka St, suit 147 03680 Kiev - Ukraine
Tel. +38 044 391 59 43

DAB PUMPS CHINA
No.40 Kaituo Road, Qingdao Economic & Technological Development Zone Qingdao City, Shandong Province - China PC: 266500
info.china@dwtgroup.com
Tel. +8653286812030-6270
Fax +8653286812210

DAB PUMPEN DEUTSCHLAND GmbH
Tackweg 11 D - 47918 Tönisvorst - Germany
info.germany@dwtgroup.com
Tel. +49 2151 82136-0
Fax +49 2151 82136-36

000 DAB PUMPS
Novgorodskaya str. 1, block G office 308, 127247, Moscow - Russia
info.russia@dwtgroup.com
Tel. +7 495 122 0035
Fax +7 495 122 0036

DAB PUMPS DE MÉXICO, S.A. DE C.V.
Av Gral Álvaro Obregón 270, oficina 355 Hipódromo, Cuauhtémoc 06100 México, D.F.
Tel. +52 55 6719 0493

PDF preview unavailable. Download the PDF instead.

NOVA 4100 Instruction Manual Adobe PDF Library 15.0 Adobe InDesign CC 2015 (Windows)

Related Documents

Preview DAB Pulsar Dry Submersible Pump Quick Start Guide
Concise guide for installing and operating the DAB Pulsar Dry submersible pump, including technical specifications, safety precautions, and connection details.
Preview DAB FEKA 600 Submersible Sewage Pump - Technical Specifications and Performance
Explore the DAB FEKA 600 submersible sewage pump. This document provides comprehensive technical data, performance curves, material specifications, electrical details, and dimensions for domestic wastewater applications.
Preview DAB Esybox Mini 3 Quick Installation Guide
A concise guide for the quick installation of the DAB Esybox Mini 3 variable speed booster pump, covering setup, connections, and initial operation.
Preview DAB Esytank Pro: Water Storage and Booster Set Solutions
Discover the DAB Esytank Pro, a range of modular water storage tanks and variable speed booster sets offering efficiency, connectivity, and reliability for residential and commercial applications. Features include WRAS approval, remote monitoring via D.Connect, and quiet water-cooled pumps.
Preview EN 60335-1: International Safety Standard for Household Appliances
The EN 60335-1 standard provides essential safety requirements for electrical household appliances, ensuring safe operation and installation across multiple languages.
Preview DAB E.SWIM Epro Pump Quick Guide
A concise guide to installing and operating the DAB E.SWIM Epro pump, covering setup wizard, manual operation, key features, and troubleshooting.
Preview Guía Rápida de Selección de Bombas DAB: Encuentre la Solución Ideal
Descubra la guía rápida de selección de bombas DAB para aplicaciones domésticas, industriales y de riego. Encuentre la bomba perfecta para sus necesidades de agua, desde suministro hasta gestión de aguas residuales.
Preview DAB Evosta Circulators: Smart Technology for Efficient Heating and Cooling
Discover the DAB Evosta 2 and Evosta 3 electronic circulators, featuring advanced DAB 4.0 technology, IPX5 water protection, and energy-efficient operation for domestic and commercial heating and cooling systems. Includes technical specifications and magnetic filter solutions.