DAB Pulsar Dry Submersible Pump Quick Start Guide

DAB Pulsar Dry Submersible Pump Quick Start Guide

Brand: DAB

Product Overview & Specifications

This guide provides essential information for the installation and operation of the DAB Pulsar Dry submersible pump.

Key Specifications:

  • Model Series: Pulsar, Pulsar Dry
  • Operating Temperature: Maximum 40°C (104°F), Minimum 0°C (32°F)
  • Head Range (H): 94-32 meters
  • Minimum Head (Hmin): 32 meters
  • Voltage/Current: 110V/230V, 1A/0.5A
  • Ingress Protection: IP 55
  • Insulation Class: I.CL. F
  • Origin: Made in Italy
  • Maximum particle concentration: 50 gr/m³ (0.0499 oz/ft³)
  • Maximum start cycles per hour: 20/h

Installation Instructions

Follow these steps for proper installation:

Step 1: Safety and Temperature Precautions

⚠️ Observe general safety precautions. Ensure the operating temperature is within the specified limits: max 40°C (104°F) and min 0°C (32°F).

Step 2: Pump Placement

Lower the submersible pump unit into the well or tank. Ensure the pump is positioned correctly, and attach any included float switch.

Installation Recommendation:

  • Maintain a minimum distance of 30cm (11.8 inches) from the bottom of the tank/well.
  • A slight tilt of 3° is recommended for optimal operation.

Step 3: Electrical Connections

Connect the pump according to the electrical configuration. Diagrams show options for Standard (single-phase) and Three-Phase connections, often requiring a control box. Ensure correct wiring, noting labels such as CAP4L1 N B, M4, 1ph.

Step 4: Securing Connections

Tighten electrical connections securely, adhering to the specified torque of 7 Nm. Avoid over-tightening or incorrect methods (indicated by ❌).

System Integration and Operation

The pump can be integrated into various water systems. A typical setup includes connection to an optional pressure tank and a control system for managing water pressure and flow.

Typical Application: The pump can supply water to domestic settings, such as bathrooms and kitchens, from a water source like a tank.

Operation: The pump is controlled via an ON/OFF switch. Ensure the pump is submerged in water for operation.

Maintenance and Performance

The pump is designed to handle water with a maximum particle concentration of 50 gr/m³.

Torque Specification: For certain connections, ensure torque is greater than 7 Nm if required by specific components.

Distributor Information

DAB PUMPS has a global presence. Contact information for various regional offices is provided:

  • UK: DAB PUMPS LTD., 6 Gilbert Court Newcomen Way, Severalls Business Park, Colchester Essex C04 9WN. Email: salesuk@dwtgroup.com, Tel: +44 0333 777 5010
  • Spain: DAB PUMPS IBERICA S.L., Calle Verano 18-20-22, 28850 - Torrejón de Ardoz - Madrid. Email: info.spain@dwtgroup.com, Tel: +34 91 6569545, Fax: +34 91 6569676
  • Belgium: DAB PUMPS B.V., 't Hofveld 6 C1, 1702 Groot Bijgaarden. Email: info.belgium@dwtgroup.com, Tel: +32 2 4668353
  • Netherlands: DAB PUMPS B.V., Albert Einsteinweg, 4, 5151 DL Drunen. Email: info.netherlands@dwtgroup.com, Tel: +31 416 387280, Fax +31 416 387299
  • USA: DAB PUMPS INC., 3226 Benchmark Drive, Ladson, SC 29456. Email: info.usa@dwtgroup.com, Tel: 1-843-797-5002, Fax: 1-843-797-3366
  • South Africa: DAB PUMPS SOUTH AFRICA, Twenty One Industrial Estate, 16 Purlin Street, Unit B, Warehouse 4, Olifantsfontein - 1666. Email: info.sa@dwtgroup.com, Tel: +27 12 361 3997
  • Germany: DAB PUMPS GmbH, Am Nordpark 3, 41069 Mönchengladbach. Email: info.germany@dwtgroup.com, Tel: +49 2161 47 388 0, Fax: +49 2161 47 388 36
  • Poland: DAB PUMPS POLAND SP. Z.O.O., Ul. Janka Muzykanta 60, 02-188 Warszawa. Email: polska@dabpumps.com.pl
  • China: DAB PUMPS (QINGDAO) CO. LTD., No.10 Xindong Road, Jiulong Town, Jiaozhou City, Qingdao City, Shandong Province. Email: info.china@dabpumps.com
  • Hungary: DAB PRODUCTION HUNGARY KFT., H-8800 Nagykanizsa, Buda Ernő u.5. Tel: +36 93501700
  • Mexico: DAB PUMPS DE MÉXICO, S.A. DE C.V., Av Amsterdam 101 Local 4 Col. Hipódromo Condesa, Del. Cuauhtémoc CP 06170 Ciudad de México. Tel: +52 55 6719 0493
  • Australia: DAB PUMPS OCEANIA PTY LTD, 426 South Gippsland Hwy, Dandenong South VIC 3175. Email: info.oceania@dwtgroup.com, Tel: +61 1300 373 677

Headquarters: DAB PUMPS S.p.A., Via M. Polo, 14 - 35035 Mestrino (PD) - Italy. Tel: +39 049 5125000 - Fax: +39 049 5125950. Website: www.dabpumps.com

Document Code: 60211029. Version: 11/24.

Models: PULSAR, PULSAR 5 Inch Submersible Pumps, 5 Inch Submersible Pumps, Submersible Pumps, Pumps

File Info : application/pdf, 2 Pages, 1.62MB

PDF preview unavailable. Download the PDF instead.

pulsar dab quick guide multi-60211029

References

Adobe PDF Library 17.0 Adobe InDesign 20.0 (Windows)

Related Documents

Preview DAB NOVA 4100 Submersible Pump Owner's Manual
This manual provides operating instructions, safety measures, technical data, and troubleshooting for the DAB NOVA 4100 submersible pump.
Preview Manuale di Installazione e Manutenzione DAB DIVERTRON
Guida completa per l'installazione, il funzionamento e la manutenzione delle pompe sommergibili DAB DIVERTRON, inclusi consigli tecnici e risoluzione problemi.
Preview DAB Esybox Mini 3 Quick Installation Guide
A concise guide for the quick installation of the DAB Esybox Mini 3 variable speed booster pump, covering setup, connections, and initial operation.
Preview DAB E.SWIM Epro Pump Quick Guide
A concise guide to installing and operating the DAB E.SWIM Epro pump, covering setup wizard, manual operation, key features, and troubleshooting.
Preview DAB FEKA 600 Submersible Sewage Pump - Technical Specifications and Performance
Explore the DAB FEKA 600 submersible sewage pump. This document provides comprehensive technical data, performance curves, material specifications, electrical details, and dimensions for domestic wastewater applications.
Preview Guía Rápida de Selección de Bombas DAB: Encuentre la Solución Ideal
Descubra la guía rápida de selección de bombas DAB para aplicaciones domésticas, industriales y de riego. Encuentre la bomba perfecta para sus necesidades de agua, desde suministro hasta gestión de aguas residuales.
Preview EN 60335-1: International Safety Standard for Household Appliances
The EN 60335-1 standard provides essential safety requirements for electrical household appliances, ensuring safe operation and installation across multiple languages.
Preview DAB EVOSTA Series Circulator Pumps: Installation and Maintenance Guide
Comprehensive guide for installing and maintaining DAB EVOSTA2, EVOSTA3, and EVOSTA2 SOL circulator pumps. Learn about features, technical data, safety, and operational modes for efficient heating and conditioning systems.