SMART HOME VIEW WIRELESS 30810.x - 02973 Connected dial thermostat

Three Operating Modes

The thermostat supports three alternative operating modes:

  • Stand alone: Requires the View Wireless App for management via smartphone/tablet.
  • Bluetooth®: Requires the View Wireless App for management via smartphone/tablet.
  • Zigbee: Requires a Zigbee Hub (e.g., Samsung SmartThings Hub) and voice assistants like Amazon Alexa, Google Assistant, Siri (Homekit) for voice operation.

Configuration typically involves downloading the View Wireless App, creating an installer account on MyVimar, and following app-specific setup procedures.

Configuration Procedures

Stand Alone Configuration

  1. Wire all thermostats.
  2. Start the View Wireless App and log in with created credentials.
  3. Create the system and environments.
  4. Associate thermostats with environments: Select "Add" (+), choose environment, name it, activate Bluetooth on tablet/smartphone, approach thermostat, press for 5 seconds until the ring flashes blue.
  5. Set functions and parameters for each thermostat.
  6. In the "Temperature control" menu, set time schedules, operating mode setpoints, and current time.

Bluetooth® Configuration

  1. Wire all devices (switches, relays, thermostats, gateway).
  2. Start the View Wireless App and log in.
  3. Create the system and environments.
  4. Associate all devices except the gateway. To associate the thermostat: Select "Add" (+), choose environment, name it, activate Bluetooth, approach thermostat, press for 5 seconds until the ring flashes blue.
  5. Set function, parameters, and accessories for each device.
  6. Transfer device configuration to the gateway and connect it to Wi-Fi.
  7. Transfer the system to the Administrator user.
  8. Refer to the View Wireless App manual on www.vimar.com for full details.

Zigbee Configuration

  1. Follow steps 1-2 from Bluetooth configuration.
  2. Associate the device directly to a Zigbee Hub (e.g., Amazon Echo Plus, SmartThings Hub).
  3. Download Zigbee software using the View Wireless App. Press the device key until "bt" is displayed and the ring blinks blue.
  4. After conversion or software update, the device enters pairing mode for 5 minutes (ring blinks white). If not in pairing mode, power cycle the device.
  5. Associate the device according to the Zigbee Hub's procedure.
  6. Associate the module according to the Zigbee Hub's manufacturer documentation.
  7. Set thermostat parameters. Within 10 minutes of power-up or restart, press the relevant key to change parameters.
  8. Set Winter/Summer Calibration: Press key for 5 seconds to start "heating offset temperature" configuration (2-minute timeout). Ring flashes amber, "H" appears. Adjust offset with the dial. Press key for 5 seconds to confirm. Ring flashes cyan, "C" appears, and a 2-minute timer starts for "cooling offset temperature" adjustment. Adjust offset with the dial. Press key for 5 seconds to confirm cooling offset. Three cyan flashes confirm saving. Timeout expires if no selection is made.
  9. Set Ring Color: Press key for 5 seconds to start ring color configuration (2-minute timeout). "LeD" appears. Press "Display Brightness" button to cycle through colors. Press key for 5 seconds to confirm. Three flashes confirm saving. Timeout expires if no selection is made.

Thermostat Controls and Indicators

The thermostat features front buttons, a display, a dial, and a lighting ring for operation and status indication.

Key Controls:

  • Dial: Used to set new setpoints. In Bluetooth automatic mode, turning the dial switches to manual operation for a user-defined period. In manual or reduction modes, it maintains the setpoint.
  • Buttons:
    • Short press: Selects degrees Celsius/Fahrenheit.
    • Long press (5 s): Enters configuration phase (displays "bt").
    • Prolonged press (30 s within first 5 min of power-on): Resets the device (displays "rst").
  • Display Brightness/RGB LED:
    • 1st press: Shows current brightness.
    • Subsequent presses: Cycles through brightness levels L-3 (high), L-2 (medium), L-1 (low), L-0 (off).

Display Indicators:

  • bt: Device in Bluetooth configuration mode.
  • off: Thermostat is off.
  • on: Thermostat is on.
  • °C / °F: Displays temperature in Celsius or Fahrenheit.
  • L-0 to L-3: Standby brightness levels.
  • H: Heating mode.
  • C: Air conditioning mode.
  • opn: Open window detected (requires magnetic contact art. 03980).

Lightable Ring Signalling:

  • All flashing blue: Thermostat in configuration mode.
  • All lit amber*: Thermostat in heating mode and relay active.
  • All lit blue**: Thermostat in air conditioning mode and relay active.
  • Lit amber*: Thermostat in heating mode and relay not active.
  • Lit blue**: Thermostat in air conditioning mode and relay not active.
  • Flashing red: Thermostat lost hourly value in automatic mode and switched to manual mode. Returns to automatic when hourly value is received.
  • * Amber with automatic color or selected color.
  • ** Blue with automatic color or selected color.

Zigbee Technology Mode Signalling Summary:

Colour of the ringDisplayMeaning
Flashing white (max 5 min.)Measured TemperatureActive pending Hub association
Flashing blue (max 2 min.)btPending receipt of a firmware update
Blue permanentbtDevice associated via Bluetooth with the smartphone
Flashing amber (max 2 min.)HHeating temperature calibration
Flashing cyan (max 2 min.)CCooling temperature calibration
Flashing cyan (three times)Save Calibration
Fixed current color (max 2 min.)LeDRing color setting
Flashing (three times)Save ring color
Flashing green (quickly 3 times)Device correctly associated with the Smart Hub

Thermostat Reset and Date/Time Setting

Resetting the Thermostat

To restore factory settings, within the first 5 minutes of powering, press the key for 30 seconds. The ring flashes blue, then emits two white flashes to confirm the operation.

Thermostat Date/Time Setting

In Stand alone mode with "ON Mode"-"Automatic" set, date and time can be set directly on the device if there's a mains voltage outage. Alternatively, to change time without an outage, press for 5 seconds and follow the steps:

  1. Press to enter "Time entry" phase. Keys [up], [down], [left], [right] are not operational.
  2. Turn the dial to display the desired day of the week (1=Monday to 7=Sunday).
  3. Press to confirm the day and proceed to set the time.
  4. Turn the dial to display the hours (00-23).
  5. Press to confirm the hours and proceed to set the minutes.
  6. Turn the dial to display the minutes (00-59).
  7. Press to confirm the minutes. The thermostat returns to its previous state, and the display/ring stops flashing.

Note: If no selection is made within 2 minutes during these phases, the thermostat exits the procedure. The display and part 2 of the ring flash, and a key flashes red during selection.

Installation Rules

  • Installation and configuration must be performed by qualified personnel according to local electrical regulations.
  • The C-NO relay contact must be protected against overloads with a device (fuse or switch) rated at a maximum of 10 A.
  • Do not connect a SELV circuit to the C-NO terminals due to lack of double insulation on L-N terminals.
  • Install the device in a flush or surface mounting box at a height of 1.5 meters. Position it for accurate room temperature detection, avoiding recesses, behind doors/curtains, heat sources, forced ventilation, or atmospheric factors. Avoid perimeter walls or proximity to heat-generating devices (e.g., dimmers, lamps).

Characteristics

  • Rated Supply Voltage: 100-240 V~, 50/60 Hz
  • Dissipated Power: 0.55 W
  • RF Transmission Power: < 100mW (20dBm)
  • Frequency Range: 2400-2483.5 MHz
  • Terminals:
    • 2 terminals (L and N) for line and neutral.
    • 2 terminals for external temperature probe (art. 02965.1, 20432-19432-14432). Max cable length: 10 m (use twisted cable, min 0.5 mm²). Functions: replacement of internal sensor, average with internal, screed temperature limitation.
    • 2 C-NO relay terminals.
  • Relay Output: Voltage-free contact: 5(2) A 240 V~
  • Current Settable Setpoint: 4°C - 40°C
  • Temperature Measurement Precision (integrated probe): 0.5°C (+15°C to +30°C), 0.8°C at extremes.
  • Use: Heating/Air Conditioning (winter/summer).
  • Operating Modes: Automatic, Manual, Reduction, Absence, Protection, Off, Timed Manual.
  • Temperature Control Algorithms: ON/OFF or configurable PID.
  • Front Buttons: 4 for control, configuration, and reset.
  • RGB LED: For configuration status (flashing blue) and output status (configurable color).
  • Operating Temperature: 0 °C to +40 °C (indoor use).
  • Protection Degree: IP30
  • ErP Classification (EU Reg. 811/2013): ON/OFF: Class I (1% contribution). PID: Class IV (2% contribution).
  • Device Class: Class II.
  • Number of Manual Cycles: 3,000
  • Number of Automatic Cycles: 100,000
  • Type of Contact Opening: Micro-disconnection.
  • Action Type: 1BU.
  • Tracking Index: PTI175.
  • State of Pollution: 2.
  • Rated Pulse Voltage: 4000 V.
  • Software Class: A.
  • Reading Resolution: 0.1 °C.
  • Settings Resolution: 0.1 °C.
  • Temperature Display Update: Every 10 s.
  • Room Temperature Display: 0 °C to +40 °C.
  • Hysteresis Adjustable via App: 0.1 °C to 1 °C.
  • Hourly Temperature Setting: Via App.
  • Room Temperature During Transportation: -25 °C to +60 °C.
  • Clock Error: ≤ 1 s per day.
  • App Integration: View Wireless App for installer configuration; View Wireless App and View App for administrator program modification. Controllable via View App, Alexa, Google, Siri, and Homekit voice assistants.

Operation in Bluetooth Technology Mode (Parameters configurable via View Wireless App):

  • Lighting in standby: high, medium, low, off (default: medium).
  • Circular ring indication selection: automatic or monochrome (default: automatic).
  • RGB colour selection: configurable for monochrome mode.
  • Temperature calibration (heating/cooling): -5°C to +5°C (default: 0°C).
  • External probe use: deactivated, average with internal, replace internal (default: deactivated).
  • Relay output status: normally open, normally closed (default: normally open).
  • Control type: On/Off, PID (default: On/Off).
  • Hysteresis (On/Off control): 0.1°C to 1°C (default: 0.2°C).
  • Proportional band (PID control): 0.5°C to 5°C (default: 3°C).
  • Integrative time (PID control): 5 min to 120 min (default: 20 min).
  • Derivative time (PID control): 0 to 255 s, disabled (default: 0).
  • Cycle time (PID control): 10 min to 30 min (default: 10 min).
  • Open Window Detection (with art. 03980 contact): Reaction time (0 min to 30 min, default: 0 min), Reactivation time (0 to 12 hours, default: 1 hour).
  • View App Settings: Time schedules (T1, T2, T3), setpoints for all modes, manual operation time (1 min to 23 hours, default: 60 min), screed/external/average functions.

Operation in Zigbee Technology Mode (Parameters configurable via Zigbee Gateway):

  • Standby lighting: high, medium, low, off (default: medium).
  • Ring indication selection: automatic or monochrome (default: automatic).
  • RGB colour selection: configurable for monochromatic mode.
  • Temperature calibration (heating/cooling): -5°C to +5°C (default: 0°C).

Regulatory Compliance

  • RED Directive, RoHS directive, ErP directive.
  • Standards: EN 60730-2-7, EN 60730-2-9, EN 301 489-17, EN 300 328, EN 62479, EN 63000.
  • Vimar SpA declares compliance with Directive 2014/53/EU. Full EU declaration of conformity available at www.vimar.com.
  • Temperature control device regulation (EU) no. 811/2013.
  • REACH (EU) Regulation no. 1907/2006 - Art.33: Product may contain traces of lead.
  • WEEE Information: The crossed bin symbol indicates separate collection at end-of-life. Users must hand over equipment to appropriate municipal centers for differentiated collection.

Trademarks mentioned: Apple, iPhone, iPad, App Store (Apple Inc.), Google (Google LLC), Amazon, Alexa (Amazon.com, Inc.).

Connections

The thermostat can be connected to circulation pumps, burners, solenoid valves, and temperature probes.

The connection diagram illustrates the wiring for the thermostat. It shows terminals for Line (L) and Neutral (N) power input (100-240V AC, 50/60Hz). It also indicates terminals for a C-NO relay output rated at 5(2)A 240V AC, suitable for controlling circulation pumps, burners, or solenoid valves. Connections for an external temperature probe (art. 02965.1, 20432-19432-14432) are also shown, with a maximum cable length of 10m recommended. A wireless symbol indicates the device's connectivity.

Use

The front buttons, display, dial, and lighting ring are used to set and display operating modes. The dial adjusts setpoints. In Bluetooth automatic mode, turning the dial switches to manual operation for a set duration. In manual or reduction modes, the thermostat maintains the dial's setpoint.

Models: 30810.x-02973, 30810.x-02973 Smart Home View Wireless Connected Dial Thermostat, Smart Home View Wireless Connected Dial Thermostat, View Wireless Connected Dial Thermostat, Wireless Connected Dial Thermostat, Dial Thermostat, Thermostat

File Info : application/pdf, 3 Pages, 691.83KB

PDF preview unavailable. Download the PDF instead.

ZIS 30810.106598.x-02973EN FI

References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Windows)

Related Documents

Preview Vimar 30810.x - 02973 Smart Home View Wireless Connected Dial Thermostat Manual
This manual provides detailed instructions for the Vimar 30810.x - 02973 Smart Home View Wireless Connected Dial Thermostat. It covers installation, configuration for Stand Alone, Bluetooth, and Zigbee modes, device operation, technical specifications, and regulatory compliance.
Preview VIMAR SMART HOME VIEW WIRELESS 30810.x - 02973 Connected Dial Thermostat Manual
Comprehensive guide to the VIMAR SMART HOME VIEW WIRELESS 30810.x - 02973 connected dial thermostat, covering setup, operation in Stand Alone, Bluetooth, and Zigbee modes, features, and technical specifications.
Preview Vimar View Wireless Smart Home Connected Dial Thermostat 30811.x - 02974 User Manual
Comprehensive guide for the Vimar View Wireless Smart Home Connected Dial Thermostat (Model 30811.x - 02974). Covers setup, configuration, and operation in Stand Alone, Bluetooth®, and Zigbee modes. Details features like temperature control, fan coil management, and integration with smart home systems.
Preview VIMAR SMART HOME VIEW WIRELESS 30811.x - 02974 Connected Rotary Thermostat User Manual
User manual for the VIMAR SMART HOME VIEW WIRELESS 30811.x - 02974 connected rotary thermostat. Covers setup, configuration, and operation in Stand Alone, Bluetooth, and Zigbee modes. Includes technical specifications, installation guidelines, and usage examples for various climate control applications.
Preview Vimar Smart Home View Wireless Thermostat: Modes and Configuration
Comprehensive guide to the Vimar Smart Home View Wireless Thermostat, covering autonomous, Bluetooth, and Zigbee modes, configuration steps, features, and usage examples for smart home climate control.
Preview VIMAR SMART CLIMA Thermostat 30440.x - User Guide and Specifications
Detailed specifications, operation, installation, and regulatory information for the VIMAR SMART CLIMA rotary dial thermostat (model 30440.x), designed for heating and air conditioning control.
Preview Vimar By-me Plus XT Thermostat 32041.x - Smart Home Automation
Detailed information on the Vimar By-me Plus XT Thermostat (model 32041.x) for smart home automation, featuring room temperature control, system integration, and advanced features like Boost and proximity sensing. Includes technical specifications, configuration, and installation guidelines.
Preview Vimar View Wireless Smart Home System Catalog
Explore the Vimar View Wireless system for smart home automation, covering lighting, climate control, security, energy management, and more. This catalog details the system's features, components, and installation options for both new and existing systems, emphasizing ease of use, flexibility, and seamless integration.