SEWAGE PUMPS
16S SERIES - 1 HP
APPLICATIONS
Sewage and effluent wastewater transfer, dewatering
FEATURES
- Permanent Split Capacitor (PSC)
- Designed for continuous duty
- 3" FNPT (76.2 mm) discharge
- Handles solids up to 2" (51 mm) diameter
- 140 °F (60 °C) liquid temperature rating
- cCSAus listed
SERIES SPECIFICATIONS
Item No. | Volts | Hz | FLA | Amps | Start | Watts | GPM/LPM @ 10' | GPM/LPM @ 20' | GPM/LPM @ 30' | Shut-Off PSI |
---|---|---|---|---|---|---|---|---|---|---|
514620 | 230 | 60 | 11 | 19.2 | 1900 | 160 (606) | 100 (379) | 40 (151) | 35' (10.7 m) 15.1 | |
514625 | 200-208 | 60 | 11 | 21 | 1500 | 160 (606) | 100 (379) | 40 (151) | 35' (10.7 m) 15.1 | |
514630 | 230 | 60 | 11 | 19.2 | 2000 | 160 (606) | 100 (379) | 40 (151) | 35' (10.7 m) 15.1 | |
514720 | 230 | 60 | 6.3 | 17 | 1900 | 160 (606) | 100 (379) | 40 (151) | 35' (10.7 m) 15.1 | |
514730 | 380/460 | 50/60 | 2.3/3.0 | 9 | 850 | 160 (606) | 100 (379) | 40 (151) | 35' (10.7 m) 15.1 | |
514750 | 200-208 | 60 | 6.8 | 17.7 | 1500 | 160 (606) | 100 (379) | 40 (151) | 35' (10.7 m) 15.1 |
* 3-phase requires control panel
Item No. | Model | HP | Volts | Phase | Discharge NPT | Switch Type/Operation | Cord | Weight (lbs/Kg) |
---|---|---|---|---|---|---|---|---|
514620 | 16S-CIM | 1 | 230 | 1 | 3" | Manual | 20' (6.1 m) | 94 (42.64 Kg) |
514625 | 16S-CIM | 1 | 200-208 | 1 | 3" | Manual | 20' (6.1 m) | 88 (39.92 Kg) |
514630 | 16S-CIM | 1 | 230 | 1 | 3" | Manual | 40' (12.2 m) | 95 (43.09 Kg) |
514720 | 16S-CIM | 1 | 230 | 3 | 3" | Manual | 20' (6.1 m) | 89 (40.37 Kg) |
514730 | 16S-CIM | 1 | 380/460 | 3 | 3" | Manual | 20' (6.1 m) | 90 (40.82 Kg) |
514750 | 16S-CIM | 1 | 200-208 | 3 | 3" | Manual | 20' (6.1 m) | 88 (39.92 Kg) |
** Three-phase pumps must have a three-phase control panel for automatic or manual operation
Certifications: SSPMA CERTIFIED
Warranty: 3 YEAR WARRANTY
Testing: 100% WET TESTED
ENGINEERING DATA
Technical drawing of the submersible sewage pump showing its profile and top view with key dimensions.
- Dimension A: 16.15" (41.02 cm)
- Dimension B: 14.07" (35.74 cm)
- Dimension C: 9.89" (25.12 cm)
PERFORMANCE DATA
Performance graph illustrating the relationship between flow rate and total dynamic head.
The graph shows Total Dynamic Head in Feet (left Y-axis) and Meters (right Y-axis) versus Flow/Capacity in US Gallons Per Minute (bottom X-axis) and Liters Per Minute (top X-axis).
At zero flow, the maximum head is approximately 35 feet (10.7 m). As flow increases, the head decreases. For example, at 160 GPM (606 LPM), the head is around 15 feet (4.5 m).
CONSTRUCTION
Component | Material/Specification |
---|---|
Motor Housing | Epoxy-coated cast iron |
Impeller Material | Epoxy-coated cast iron |
Impeller Type | Two-vane, non-clog |
Volute | Epoxy-coated cast iron |
Mechanical Shaft Seal | Nitrile with carbon and ceramic faces |
Fasteners | Stainless steel |
Shaft | Stainless steel |
Bearings | Upper and lower ball bearings |
Power Cord | 16/3, STW (single-phase) 18/4, SOW (three-phase) |