Applications
The EC-1U-DV model is a slim undermount unit that installs easily and neatly underneath equipment. It is designed to automatically remove condensate water that drips from wall mount ductless air conditioners.
The EC-1U-DV model accommodates multiple electrical requirements within one pump. The DV suffix indicates that the pump is capable of operating from a wide range of supply voltage to maintain consistent pump performance.
Features
Pump - Controller
- Dual Voltage: 110 - 240 V 50/60 Hz
- Flow Rate: 2.5 gallons per hour @ 1 foot (9.5 liters per hour)
- Maximum Head: 33 feet (10 meters) shut-off
- Alarm Relay: Normally-closed, rated at 8 A resistive – 250 V alarm
- Sound Level: 21 dB(A)
- Discharge Outlet: 1/4 inch inner diameter pump discharge outlet
- Vibration Isolation: Elastomeric passive vibration isolator used to dampen pump vibration
- Thermal Protection: 176 °F
- Power Cable: 60 inch power cable
- Ambient Temperature Range: 32 °F - 140 °F
- Maximum Water Temperature: 140 °F
Reservoir
- Clear reservoir for instant visual inspection of water level, float, and filter.
- Hall effect on/off level sensors with high-water sensor feature.
- Extra-large filter screen for longer intervals between cleaning.
- Hinged reservoir platform and simple to open reservoir for easy maintenance.
- Large inlet filter.
Performance Data
Performance Data for 110-240 V, 50/60 HZ
The performance chart illustrates the relationship between flow rate and head pressure. The chart displays flow in liters per hour (LPH) on the y-axis against head in meters on the x-axis, and also shows flow in gallons per hour (GPH) on a secondary y-axis against head in feet on the x-axis. The curve indicates that as the head increases, the flow rate decreases. Based on the provided specifications, at 0 feet (0.0 meters) of head, the flow is 2.7 GPH (10.2 LPH). At 1 foot (0.3 meters) of head, the flow is 2.5 GPH (9.5 LPH). At 10 feet (3 meters) of head, the flow is 1.5 GPH (5.7 LPH), and at 20 feet (6.1 meters) of head, the flow is 1.2 GPH (4.5 LPH).
Note: Do not operate above 33 feet (10 meters) total head.
*Tested under conditions assumed consistent with competitors' published sound ratings.
Series Specifications
Item No. | Model | Input Voltage | HZ | Amps | Watts | Discharge Size | Performance (GPH / LPH) @ Head | Shut-Off Ft. | Suction Lift | PSI | Cord | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|
553527 | EC-1U-DV | 110-240 | 50/60 | 0.18 | 18 | 1/4" | 0 ft/0.0 m: 2.7/10.2 1 ft/0.3 m: 2.5/9.5 5 ft/1.5 m: 1.8/6.8 10 ft/3 m: 1.5/5.7 20 ft/6.1 m: 1.2/4.5 |
33 (10m) | 3' (.91m) | 26 | 4.9(1.5) | 1.2 lbs |
Engineering Data
The unit dimensions are provided:
- Dimension A: 11.12 inches (282.44 mm)
- Dimension B: 2.31 inches (58.67 mm)
- Dimension C: 2.19 inches (55.62 mm)
[Diagram showing the physical layout and dimensions of the EC-1U-DV unit. Dimension A is the length, Dimension B is the height, and Dimension C is the depth/width.]