CHEMICAL TRANSFER PUMPS
TE-4-MD-SC SERIES - 1/10 HP
[Image: Little Giant logo]
[Graphic: One Year Warranty seal]
APPLICATIONS
The Little Giant MD-SC series features leakproof, seal-less magnetic drives and are designed for in-line, non-submersible use. Volute, magnet housing and impeller are glass-filled polypropylene for excellent chemical resistance. Ceramic shaft and thrust washers are 99.5% pure alumina for excellent wear and trouble-free service. Pumping heads are easily rotated, cleaned or serviced with no special tools required. Spindle shaft is supported at both ends to prevent impeller damage during start-up and stop of pump.
FEATURES
- Thermally protected, totally enclosed, permanent split capacitor motor
- Sleeve bearings
- 6-foot power cord with 3-prong plug (no plug on 230V)
- Specific gravity to 1.1
- Fluid temperature to 150 °F
- Ambient air temperature to 77 °F
NOTE: Consult your local distributor or the factory for applications with higher ambient temperatures, specific gravities and viscosities.
SERIES SPECIFICATIONS
Item No. | Model | Discharge | Intake | Listing(s) | HP | Volts | Hz | Amps | Watts | Gallons per minute (Liter per minute) @ Height | Shut-Off PSI | Cord | Weight lbs (Kg) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
582504 | TE-4-MD-SC | 1/2" MNPT | 1" FNPT | UR/C-CSA | 1/10 | 115 | 50/60 | 1.7 | 185 | 14.2 (53.8) @ 1' | 13.5 (51.1) @ 3' | 12.8 (48.5) @ 6' | 11.8 (44.7) @ 9' | 9.2 (34.8) @ 15' | 24.3' (7.4 m) | 6' (1.8 m) | 9.75 (4.42 Kg) |
582514 | TE-4-MD-SC | 1/2" MNPT | 1" FNPT | UR/C-CSA | 1/10 | 230 | 50/60 | 0.7 | 150 | 14.2 (53.8) @ 1' | 13.5 (51.1) @ 3' | 12.8 (48.5) @ 6' | 11.8 (44.7) @ 9' | 9.2 (34.8) @ 15' | 24.3' (7.4 m) | 6' (1.8 m) | 9.75 (4.42 Kg) |
REPLACEMENT PARTS
Item | Part No. | Description |
---|---|---|
A | 182010 | Volute |
B | 924007 | O-Ring |
C | 921077 | Thrust Washer |
D | 183132 | Impeller |
E | 180057 | Shaft |
F | 182005 | Housing |
1 | 920003 | Wing nut |
2 | 911403 | Stud, collared |
3 | 182602 | Drive Magnet |
4 | 180037 | Mounting Bracket |
NOTE: Parts A-F contact fluid
ENGINEERING DATA
Diagram Description: The engineering data includes two diagrams illustrating the pump's dimensions. The first diagram shows a side view with an overall length of approximately 9.92 inches, an inlet/outlet diameter of approximately 1.67 inches, and mounting points of approximately 0.28 inches. The second diagram shows a front/top view with an overall height of approximately 5.13 inches, a width of approximately 2.63 inches, and mounting points of approximately 0.41 inches. Other dimensions provided include body lengths of approximately 5.06 inches and 2.21 inches, and an inlet/outlet diameter of approximately 0.96 inches.
NOTE: Designs and dimensions may vary for various reasons (i.e. type of motor). This information should be used as general guide rather than an unqualified guarantee. Specifications are subject to change without prior notice.
PERFORMANCE DATA
The performance data is presented as a graph showing the relationship between Head (in Feet and Meters) and Flow/Capacity (in US Gallons Per Minute and Liters Per Minute). The graph indicates that as the flow rate increases, the head decreases. At zero flow, the head is approximately 25 feet (7.6 meters). The head drops to zero at a flow rate of approximately 16 US gallons per minute (60 liters per minute).