Lithonia Lighting LBR6 6" LED Downlight: Features, Specifications, and Ordering
Features & Specifications
Intended Use
Typical applications include corridors, lobbies, conference rooms, and private offices.
Construction
Retrofit, remodel, and new construction mounting types. See table for compatible ceiling openings and thickness range. Optional goof rings available for additional overlap trim coverage. 1/2"-1-1/2" ceiling thickness. 25° ambient temperature.
Optics
IC rated up to 1000lm. LEDs are binned to a 3-step Mac Adam Ellipse. 55° cutoff. New construction frame accessories approved for 8 (4 in/4 out) No. 12 AWG conductors rated for 90°C through wiring. 80CRI standard (90CRI optional). UGR is zero for fixtures aimed at nadir with a cut-off equal to or less than 60deg, per CIE 117-1996 Discomfort Glare in Interior Lighting. UGR FAQ.
Electrical
Adjustable lumen output with four module options. Fixed lumen options also available. MVOLT 120/277V 50/60Hz driver (0-10V & 120V Phase Dimming to 10% or 1% min dimming level). FCC CFR Title 47 Part 15 Class A for 277V. FCC CFR Title 47 Part 15 Class B for 120V.
Lumen Maintenance
L80 at 60,000 hours.
Listings
- Certified to US and Canadian safety standards.
- Damp location standard (Wet Location (WL) optional, requires covered ceiling).
- TAA compliant.
- UFC (3-530-01) specification compliant for power factor and THD.
- GSA P100 6.2.4 compliant for power quality at full output; compliant up to 2000lm at fully dimmed output.
- Drivers are ROHS compliant.
- Title 24 compliant (90CRI, up to 1000lm).
Warranty
5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions
Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice.
Performance Data
LBR6 AR LSS MWD (80CRI)
Lumen Output Lumens | Wattage | 30K/80CRI | 35K/80CRI | 40K/80CRI | 50K/80CRI | ||||
Delivered Lumens | LPW | Delivered Lumens | LPW | Delivered Lumens | LPW | Delivered Lumens | LPW | ||
ALO1 (500LM) | 6 | 571 | 99 | 585 | 101 | 599 | 103 | 617 | 105 |
ALO1 (750LM) | 9 | 905 | 102 | 926 | 103 | 948 | 105 | 977 | 108 |
ALO1 (1000LM) | 13 | 1270 | 98 | 1300 | 100 | 1330 | 102 | 1372 | 104 |
ALO2 (1000LM) | 13 | 1346 | 108 | 1378 | 110 | 1410 | 112 | 1454 | 115 |
ALO2 (1500LM) | 19 | 1965 | 105 | 2011 | 107 | 2059 | 109 | 2123 | 111 |
ALO2 (2000LM) | 25 | 2476 | 100 | 2533 | 101 | 2593 | 103 | 2674 | 106 |
ALO3 (2000LM) | 25 | 2547 | 103 | 2606 | 105 | 2668 | 107 | 2751 | 109 |
ALO3 (2500LM) | 32 | 3075 | 98 | 3146 | 100 | 3221 | 101 | 3321 | 104 |
ALO3 (3000LM) | 38 | 3492 | 93 | 3573 | 95 | 3658 | 96 | 3771 | 99 |
ALO4 (4000LM) | 39 | 4180 | 107 | 4265 | 109 | 4350 | 112 | 4393 | 113 |
ALO4 (4500LM) | 44 | 4613 | 105 | 4707 | 107 | 4801 | 109 | 4848 | 110 |
ALO4 (5000LM) | 49 | 5017 | 102 | 5119 | 104 | 5221 | 107 | 5273 | 108 |
LBR6 MS MWD (80CRI)
Lumen Output Lumens | Wattage | 30K/80CRI | 35K/80CRI | 40K/80CRI | 50K/80CRI | ||||
Delivered Lumens | LPW | Delivered Lumens | LPW | Delivered Lumens | LPW | Delivered Lumens | LPW | ||
ALO1 (500LM) | 6 | 480 | 99 | 584 | 101 | 597 | 102 | 616 | 105 |
ALO1 (750LM) | 9 | 760 | 102 | 924 | 103 | 946 | 105 | 975 | 108 |
ALO1 (1000LM) | 13 | 1067 | 98 | 1297 | 100 | 1328 | 102 | 1369 | 104 |
ALO2 (1000LM) | 13 | 1131 | 108 | 1375 | 110 | 1408 | 112 | 1451 | 115 |
ALO2 (1500LM) | 19 | 1651 | 105 | 2007 | 106 | 2055 | 108 | 2118 | 111 |
ALO2 (2000LM) | 25 | 2079 | 99 | 2528 | 101 | 2588 | 103 | 2668 | 105 |
ALO3 (2000LM) | 25 | 2139 | 103 | 2601 | 104 | 2663 | 106 | 2745 | 109 |
ALO3 (2500LM) | 32 | 2583 | 98 | 3140 | 99 | 3214 | 101 | 3314 | 103 |
ALO3 (3000LM) | 38 | 2933 | 93 | 3566 | 94 | 3651 | 96 | 3764 | 98 |
ALO4 (4000LM) | 39 | 3511 | 90 | 3583 | 92 | 3654 | 94 | 3690 | 95 |
ALO4 (4500LM) | 44 | 3875 | 88 | 3954 | 90 | 4033 | 92 | 4072 | 93 |
ALO4 (5000LM) | 49 | 4214 | 86 | 4300 | 88 | 4386 | 90 | 4429 | 90 |
* Tested in accordance with IESNA LM-79-08. u8226
* Tested to current IES and NEMA standards under stabilized laboratory conditions.
* CRI: 80 typical
Items marked by a shaded background qualify for the Design Select program and ship in 15 days or less. To learn more about Design Select, visit www.acuitybrands.com/designselect. *See ordering tree for details.
Module Ordering
Ordering Information
Lead times will vary depending on options selected. Consult with your sales representative.
Example: LBR6 ALO2 SWW1 AR LSS MWD MVOLT UGZ 90CRI
Series | Lumens + | Color temperature + | Distribution | Voltage | Driver | Emergency + | Control Input + | Options | Reflector Color | Reflector Flange + | Reflector Finish |
LBR6 | Adjustable Lumen Output ALO1 500/750/1000lm ALO2 1000/1500/2000lm ALO3 2000/2500/3000lm ALO4 4000/4500/5000lm | Switchable CCT SWW1 3000K-3500K-4000K-5000K Fixed CCT 27K 2700K 30K 3000K 35K 3500K 40K 4000K 50K 5000K | MWD Medium wide (1.0 s/mh) WD Wide (1.2s/mh) WW Wallwash | MVOLT 120 277 347 | UGZ Universal dimming to 10% 0-10V; line voltage dimming (120V) UGZ1 Universal dimming to 1% 0-10V; line voltage dimming (120V) DALI DALI dimming to 1% D1 Minimum dimming 1% driver for use with SSAIR | (blank) No Emergency Needed ELR Battery pack (10W constant power) Non-T20 Compliant remote test switch ETS Iota Emergency Transfer System E10WCP Battery pack (10W constant power) T20 Compliant integral test switch E10WCPR Battery pack (10W constant power) T20 Compliant remote test switch E10WRSTAR Emergency battery pack, 10W with remote test switch and Iota STAR technology | (blank) No Control Input Needed SSAIR Wireless standalone embedded control by SensorSwitch NLIGHT Embedded wired controls from nLight NLIGHTER Embedded wired controls from nLight with UL924 listed emergency operation NLTAIR2 nLight® Air enabled NLTAIREM2 nLight® AIR Dimming Pack Wireless Controls. UL924 Emergency Operation, via power interrupt detection. | 90CRI High CRI (90+) AT Airtight EC1 Extended Conduit (18") EC6 Extended Conduit (6ft) WL Wet Location (IP55) QDS Quick disconnect plugs CP Chicago Plenum | AR Clear BR Black painted MS Metallic Silver WR White painted TCPC Custom painted trim TRALTBD RAL painted trim | (blank) TRW SWW1 TRBL FCPC FRALTBD | LSS Semi-specular |
LBR6WW 6" Retrofit Wallwash |
NOTE: + indicates option value has ordering restrictions. Please reference the Option Value Ordering Restictions chart below.
Option Value Ordering Restrictions
Options | Restriction |
Adjustable Lumens/CCT Fixed Lumens/CCT WW MS, WR, BR WR BR TRALTBD, FRALTBD TCPC, FCPC TRW, TRBL LSS 347V DALI E10WCPR E10WCP E10WSTAR ELR ETS SSAIR NLIGHT NLIGHTER NLTAIR2 NLTAIREM2 WL QDS EC1, EC6 AT CP | Adjustable Lumen Output and Switchable CCT must be specified together (for Example: ALO1 SWW1) Fixed Lumen Output and Fixed CCT must be specified together (for Example: 10LM 30K) Not available with WL, EL, E10WCP. Not available with LSS reflector finish Not available with TRW Not available with TRBL RALTBD for pricing only. Replace with applicable RAL number and finish when ready to order. See the RAL BROCHURE for available color options. Not available with TCPC or FCPC. CPC options for pricing only. Custom color chip needs to be sent in to your Customer Resolution specialist before order can be processed. Click HERE for more details. Not available with TRAL or FRAL. Available with MS and AR reflectors only. Not available with BR or WR or MS Not available with CP, QDS, ELR, E10WCP, E10WCPR, NLIGHT, NLIGHTER, NLTAIR2, or NLTAIREM2 Not available with fixed lumens or CCT. Max 4500 lumens. Not available with EC1, EC6, AT, QDS, CP, 347V, NLIGHTER, NLTAIREM2, WL, ALO3 & ALO4 w/DALI, OR 2000-4500 lumens w/SSAIR. Not available with WW, EC1, EC6, AT, QDS, CP, 347V, NLIGHTER, NLTAIREM2, WL, ALO3 & ALO4 w/DALI, OR 2000-4500 lumens w/SSAIR. Not available with wet location, EC1, EC6, QDS, CP, 347V, NLIGHTER, NLTAIREM2, ALO3 & ALO4 w/DALI, OR 2000-4500 lumens w/SSAIR. Top access installation or 17.5" plenum clearance required for roomside installation. Not available with integral test switch Not available EC1, EC6, QDS, CP, 347V, NLIGHTER, NLTAIREM2, ALO3 & ALO4 w/DALI, OR 2000-4500 lumens w/SSAIR. Not available with, QDS, ELR, E10WCP, E10WCPR, 347V, SSAIR, NLIGHT, NLIGHTER, NLTAIR2, NLTAIREM2, DALI, or D1 driver Only available with D1 driver. Not available with CP, NLIGHT, NLIGHTER, NLTAIR2, NLTAIREM2, UGZ, or DALI drivers. Max 4500 lumens. Fixed lumens and CCT only. Not available with 2000-4500lm in conjunction with emergency batterypacks. Must specify UGZ1. Not available with CP, QDS, SSAIR, ETS, UGZ, DALI, or D1 drivers. Not available with 347V. Must specify UGZ1. Not available with CP, QDS, ELR, E10WCP, E10WCPR, DALI, or D1 drivers. Not available with 347V. Must specify UGZ1. Not available with CP, QDS, SSAIR, ETS, UGZ, DALI, or D1 drivers. See UL 924 Sequence of Operation table. Non-emergency luminaires with this option can be used as a normal power sensing device for nLight AIR devices and luminaires with EM emergency options. Not available with 347V. Must specify UGZ1. Not available with CP, QDS, SSAIR, ETS, ELR, E10WCP, E10WCPR, DALI, D1, OR D10 drivers. See UL 924 Sequence of Operation table. Not available with WW, All CP is wet location, except WW (Damp). IP55 rated. Not available with E10WCP Must be specified for use with LBR_PFWQDS. Not Available with CP, emergency options, or 347V. Not Available with CP,QDS, ELR, E10WCP, or E10WCPR. Standard for CP and IP55, not available with WW. Not available with E10WCP Not available with, QDS, EC1, EC6, ELR, E10WCPR, 347V, SSAIR, NLTAIR2, NLTAIREM2, D1 drivers. For new construction applications, must be specified with LBR_PFWCP. |
Accessories
Order as separate catalog number. Shipped separately.
- LBRGR78**: Goof ring 7-3/4" to 8-3/4" for LBR6 (** specify BR,WR)
- LBRCPGR78**: Chicago Plenum Goof ring 7-3/4" to 8-3/4" for LBR6 (** specify BR, WR)
- LBRO6 AR LSS TRIM: 6" clear, semi-specular reflector
- LBRO6 ** TRIM: 6" reflector (** specify MS, WR, BR)
- LBRW6 AR LSS TRIM: 6" clear, semi-specular wallwash
- LBRW6 ** TRIM: 6" wallwash (** specify MS, WR, BR)
- LBR46810HB FPAN U: Mounting plate 4"-10" unit pack
- LBR46810HB FPAN J10: Mounting plate 4"-10" 10-pack
- LBR SDT 347V 75W ASM: Field installed 347V Step-down transformer
- SCA6: Sloped Ceiling Adapter. Degree of slope must be specified (5D, 10D, 15D, 20D, 25D, 30D). Ex: SCA6 10D.
Diagram showing the 6" GOOF RING accessory with dimensions.
Module and Mounting Frame Options
Select Module and Mounting Frame Accessory to determine compatible fixture options.
Module | Mounting Frame Accessory | Compatible Fixture Options |
LBR6 | LBR6PF | QDS, EC1, EC6, Base fixture only |
LBR6PFW | ELR, E10WCPR, E10WCP, E10WRSTAR | |
LBR6PFW EM | QDS fixture only | |
LBR6PFWQDS | QDS fixture only | |
LBR6WW | LBR6PF | QDS, EC1, EC6, Base fixture only |
LBR6PFW | ELR, E10WCPR, E10WRSTAR | |
LBR6PFW EM | QDS fixture only | |
LBR6PFWQDS | QDS fixture only |
Emergency Battery Pack Options - Field Installable
Battery Model Number | Wattage | Runtime (Minutes) | Lumen Output* @ 120 Lumens/Watt | Other |
ILB CP07 2H A | 7W | 120 | 840 | Storm Shelter / 2 Hour Runtime |
ILB CP10 A | 10W | 90 | 1200 | |
ILBLP CP10 HE SD A+ | 10W | 90 | 1200 | Title 20, Self Diagnostic |
ILBLP CP15 HE SD A+ | 15W | 90 | 1800 | Title 20, Self Diagnostic |
ILB CP20 HE A | 20W | 90 | 2400 | Title 20 |
ILB CP20 HE SD A | 20W | 90 | 2400 | Title 20, Self Diagnostic |
ILBHI CP10 HE SD A+ | 10W | 90 | 1200 | 347-480V AC Input, Title 20, Self Diagnostic |
ILBHI CP15 HE SD A+ | 15W | 90 | 1800 | 347-480V AC Input, Title 20, Self Diagnostic |
All the above are UL Listed products that are certified for field install external/remote to the fixture.
*Minimum delivered lumen output to assist in product selection for increased fixture mounting height.
The CP10 delivered emergency illumination outperforms legacy 1400 lumen fluorescent emergency ballast. Please contact us at techsupport@iotaengineering.com for any Emergency Battery related questions.
Diagrams and Dimensions
Plenum Depth Table
Aperture Size/Output | Plenum Depth* | IC | Non-IC | Non-IC Marked Spacing |
LBR6 500-1000 Lumen | 3.69 | X | 24x24x9 | |
LBR6 1000-2000 Lumen | 3.69 | X | 24x24x9 | |
LBR6 2000-3000 Lumen | - | X | ||
LBR6 4000-5000 Lumen | - | X |
*Above unfinished 1/2" ceiling plane
* All dimensions are inches (millimeters) unless otherwise noted.
Ceiling Coverage Table
Series | Trim Aperture Flange OD | Min ceiling opening | Ceiling Thickness | Max ceiling opening | Max Ceiling Opening with Goof Ring | Overall Goof Ring OD |
LBR6 ROUND | 5-5/16" | 7-5/8" | 5-3/4" | 1/2" 7-1/8" | 7-1/8" | 9-1/4" |
LBR6 ROUND | 1-1/2" 7-3/8" | 7-1/2" |
Diagrams illustrate fixture dimensions, ceiling coverage, and installation clearances for various LBR6 configurations. These include top-down and side views showing aperture size, ceiling opening requirements, plenum depth, and overall fixture dimensions, with measurements provided in inches and millimeters.
Photometry
LBR6 SWW1 ALO2 AR LSS MWD MVOLT UGZ
Input Watts: 18.1, Delivered Lumens: 1970, LPW: 108.8, S/MH: 0.94, Test No: 20-518-03
Photometric distribution curve showing light intensity distribution.
Zonal Lumen Summary table detailing lumen distribution across different zones.
Cone of Light data showing beam spread and intensity at various angles.
Luminance data (cd/sq.m) at different angles.
LBR6WW SWW1 ALO2 AR LSS WW
Input Watts: 18.7, Delivered Lumens: 1981, LPW: 105.9, S/MH: 0.67, Test No: 20-518-A1
Photometric distribution curve showing light intensity distribution.
Zonal Lumen Summary table detailing lumen distribution across different zones.
Luminance data (cd/sq.m) at different angles.
Lumen Output Multipliers
CCT Multipliers
3000K | 3500K | 4000K | 5000K |
0.98 | 1.0 | 1.01 | 1.03 |
Finish Multipliers
Clear Semi-spec (AR LSS) | Metallic Silver (MS) | White Painted (WR) | Black Painted (BR) |
1.0 | 0.84 | 1.03 | 0.60 |
CRI Multipliers
80 | 90 |
1.0 | 0.874 |
How to Estimate Delivered Lumens in Emergency Mode
Use the formula below to estimate the delivered lumens in emergency mode:
Delivered Lumens = 1.25 x P x LPW
P = Output power of emergency driver. P = 10W
LPW = Lumen per watt rating of the luminaire. This information is available on the ABL luminaire spec sheet. The LPW rating is also available at Designlight Consortium.
Dimmer Compatibility
Not compatible with DALI or DMX dimmers. For specific compatible dimmers see below.
Line Voltage Dimming:
Type | Forward Phase | ALO1 (500-1000lm) | ALO2 (1000-2000lm) | ALO3 (2000-3000lm) | ALO4 (3000-5000lm) | Comment |
MLV | Sensorswitch WPD | YES | YES | YES | YES | |
MLV | Sensorswitch CMR PDT10 ADC VLP | YES | YES | YES | YES | |
MLV | Synergy ISD 600LV | YES, 2x * | YES | YES | YES | * min 2 fixtures |
INC | Synergy ISD 600 I | YES, 2x * | YES | YES | YES | * min 2 fixtures |
MLV | Lutron Glyder GLV-600 | YES | YES | YES | YES | |
INC | Leviton SureSlide 6633 | YES | YES | YES | YES | |
MLV | Lutron Diva DVLV-600P | YES | YES | YES | YES | |
MLV | Lutron Skylark SLV-600P | YES | YES | YES | YES | |
INC | Lutron RadioRA 2 10ND | YES | YES | YES | YES | |
MLV | Leviton SureSlide 6613-PLW | YES | YES | YES | YES | |
INC | Lutron Diva DVCL-153P | YES | YES | YES | YES | |
MLV | Leviton IPM06 | YES, 2x * | YES | YES | YES | * min 2 fixtures |
INC | Leviton IP106 | YES, 2x * | YES | YES | YES | * min 2 fixtures |
INC | Control4 C4-FPD 120 | YES | YES | YES | YES |
Reverse Phase Dimmer Bank
Type | ALO1 (500-1000lm) | ALO2 (1000-2000lm) | ALO3 (2000-3000lm) | ALO4 (3000-5000lm) | |
ELV | Lutron Nova T NTELV-600 | YES | YES | YES | YES |
ELV | Lutron Diva DVELV 600P | YES | YES | YES | YES |
ELV | Lutron Maestro MAELV 600 | YES | YES | YES | YES |
ELV | Leviton Vizia VPE06-1LX | YES | YES | YES | YES |
ELV | Leviton Illumatech IPE04 | YES | YES | YES | YES |
ELV | Control4 C4-APD 120 REVERSE PHASE | YES | YES | YES | YES |
Miscellaneous Dimmers
Type | ALO1 (500-1000lm) | ALO2 (1000-2000lm) | ALO3 (2000-3000lm) | ALO4 (3000-5000lm) | |
PHA | Lutron RadioRA2 RRD-6NA | YES | YES | YES | YES |
PHA | Lutron Maestro PRO LED+ RRD-PRO | YES | YES | YES | YES |
Control Systems
Type | ALO1 (500-1000lm) | ALO2 (1000-2000lm) | ALO3 (2000-3000lm) | ALO4 (3000-5000lm) | |
MLV | Lutron LP-RPM-4U | YES | YES | YES | YES |
PHA | Lutron LP-RPM-4A | YES | YES | YES | YES |
MLV | Lutron GRAPHIC EYE QSGRJ-3P | YES | YES | YES | YES |
PHA | Lutron PA Power Module PHPM-PA-120 | YES | YES | YES | YES |
ELV | Lutron nLight nSP5PCD ELV | YES | YES | YES | YES |
0-10V Dimming:
Manufacturer | System Type | Description | P/N | ALO1 (500-1000lm) | ALO2 (1000-2000lm) | ALO3 (2000-3000lm) | ALO4 (3000-5000lm) |
ACUITY | Wall Box | sensorswitch, dimming switch with multi-way option | SPODMRA | YES | YES | YES | YES |
ACUITY | Wall Box | sensorswitch, wall switch sensor, occupancy controlled dimming | WSX D WH | YES | YES | YES | YES |
ACUITY | Control System | nLight | nPP16D | YES | YES | YES | YES |
ACUITY | Control System | nLight | nPS 80 EZ | YES | YES | YES | YES |
ACUITY | Control System | nLight Air | rPP20 D | YES | YES | YES | YES |
Lutron | Other | 0-10V (sink or source) PowPak wireless dimming module | RMJ-5T-DV-B | YES | YES | YES | YES |
Wattstopper | Control System | Digital single relay room controller (0-10V) | LMRC-211 | YES | YES | YES | YES |
Crestron | Control System | DIN Rail 0-10V fluorescent dimmer, 4 feeds, 4 channels (Green Light System) | DIN-4DIMFLV4 | YES | YES | YES | YES |
Lutron | Other | Grafik Eye 0-10V adapter | GRX-TVI | YES | YES | YES | YES |
Leviton | Wall Box | Illumatech 0-10V | IP710-DLX | YES | YES | YES | YES |
Lutron | Control System | Mounted in the Homeworks QS panel - 0-10V dimmer (sink or source) | GRX-TVM2 | YES | YES | YES | YES |
Lutron | Wall Box | Nova 0-10V wallbox dimmer (use with PP-120-H line voltage relay) | NTFTV | YES | YES | YES | YES |
Lutron | Wall Box | Nova 0-10V wallbox dimmer (use with PP-120-H line voltage relay) | NTSTV-DV | YES | YES | YES | YES |
Lutron | Wall Box | Nova T | NFTV | YES | YES | YES | YES |
Leviton | Wall Box | Renior II 0-10V | AWSMG-7DW | YES | YES | YES | YES |
Lighting Controls
SensorSwitch
SensorSwitch™ offers standalone wired and wireless lighting controls solutions designed for room-based applications. Our products offer reliable performance and ease of installation. Visit Sensorswitch.com.
Diagram illustrating Wireless Embedded Controls for SensorSwitch, showing luminaire installation, pairing tool usage, and the result of successful pairing (fixtures dimming to 10% brightness).
nLight
nLight® is your networked lighting controls platform, for indoor and outdoor applications, providing wired or wireless options. Scaling from room to campus-wide applications, it is the one platform that grows with your business today and tomorrow; to seamlessly address energy cost optimization, building code compliance, improved occupant comfort, and much more. nLight also interfaces with DALI®, BACnet®, DMX and additional third-party devices. Visit nLightcontrols.com.
Diagram illustrating Wired Embedded Controls for nLight, showing luminaire installation, wired wall switch connection, and connection via CAT-5e cables.
Diagram illustrating Wireless Embedded Controls for nLight, showing luminaire installation, AIR battery-powered wall switch, and pairing via CLAIRITY+ mobile app.
UL924 Sequence of Operation
- EM devices will remain at their high-end trim and ignore wireless lighting control commands, unless a normal-power-sensed (NPS) broadcast is received at least every 8 seconds.
- Using the CLAIRITY+ mobile app, EM devices must be associated with a group that includes a normal power sensing device to receive NPS broadcasts.
- Only non-emergency rPP20, rLSXR, rSBOR, rSDGR, and nLight AIR luminaires with version 3.4 or later firmware can provide normal power sensing for EM devices. See specification sheets for control devices and luminaires for more information on options that support normal power sensing.