SJE VERTICALMASTER 3 PLUS Float Switch Installation Instructions
Electrical Warnings
Electrical Shock Hazard
Disconnect power before installing or servicing this product. A qualified service person must install and service this product according to applicable electrical and plumbing codes.
Explosion or Fire Hazard
Do not use with flammable liquids. Install in accordance with ANSI/NFPA 70.
Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch or cable becomes damaged or cracked. Keep these instructions with warranty after installation. This product must be installed in accordance with National Electric Code, ANSI/NFPA 70 so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.
Product Overview
The SJE VERTICALMASTER 3 PLUS Float Switch is a mechanically activated pump switch designed for direct control of pumps in non-potable water applications. It is well suited for applications with limited space, such as small sump chambers, effluent applications, and laundry trays, as well as in large tanks. It is available for pump down applications only.
A Pump Switch is designed for Horsepower (HP) rated loads and is not suitable for control (pilot duty) applications. It will fail prematurely when switching loads less than 1 Amp at 120 VAC. For control applications, select a float switch from the Control Switch offering.
This product is covered by U.S. Patents D837745-S, 10141141-BS, D818441-S, D817455-S, 20170250041-A1, Canadian Patent CA3011555, and Canadian Design 174,615; 179,579; 174,614. Foreign Patents are Pending.
Installation Instructions
Step 1: Determine Location
Determine the location for the float switch.
Diagram Description: Shows a sump pit with a pump, discharge pipe, and the float switch assembly. The float switch has a lift rod, float, and float stop. Connections are shown for the switch plug and pump plug.
Step 2: Secure to Discharge Pipe
Secure the float switch to the discharge pipe by inserting the hose clamp through the mounting bracket slots and tightening the hose clamp.
Diagram Description: Shows a close-up of the float switch mounting bracket attached to a discharge pipe with a hose clamp.
Step 3: Adjust Pumping Range
Adjust the pumping range by setting the float's activation level and the float stop.
Diagram Description: Illustrates the float switch at different water levels, indicating the 'Activation Level' and 'Pumping Range'.
Step 4: Wiring Connections
For units without plugs, connect wires as shown.
Diagram Description: Wiring diagram shows connections for Power Source (G, L1, L2) to Load (G, L1, N) via the switch cable (G, WHITE, BLACK). Connections are made in a dry junction box.
WARNING: In 230 VAC installations, one side of the line going to the load is always HOT, whether the switch is on or off. Install a double pole disconnect on all 230 VAC circuits. Ensure cable connections are performed in a dry junction box or other watertight seal that seals both conductors and cable jacket. Failure to do so could result in electrical shock hazard and/or water traveling down the cable and entering the switch. Failure to guard against this may affect switch performance.
Step 5: Test Unit
Test the unit after installation to ensure proper operation.
Preventative Maintenance
- Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the product. Replace the product immediately if any damage is found or suspected.
- Periodically check to see that the float and rod are free to move and operate the switch.
- Use only SJE Rhombus® replacement parts.
Product Returns Notice
Products returned must be cleaned, sanitized, or decontaminated as necessary prior to shipment to ensure that employees will not be exposed to health hazards in handling said material. All applicable laws and regulations shall apply.
Warranty Information
SJE Rhombus offers a Five-Year Limited Warranty. For complete terms and conditions, please visit www.sjerhombus.com.
Technical Support
For technical support, contact SJE Rhombus:
Phone: +1 800-746-6287