Technical Data

Compressor

Brand: SECOP

Model Information

Designation: FRK5G

Sales Code: 106G5463

Configurations: 220-240V/50Hz 1~, 208-230V/60Hz 1~

Compressor Design

Oil Type: Polyolester

Oil Viscosity: 19,2 cSt

Oil Quantity: 240 cm³ / 8,1 fl.oz

Refrigerant Charge - Technical Limit: 700g / 24,7oz

Free Gas Volume (Compressed): 1560 cm³ / 52,7 fl.oz

Weight: 8,9 kg / 19,6 lbs

Motor Protection: external

Winding Resistance (Main): 13,1 Ω (at 25°C)

Winding Resistance (Auxiliary): 25,3 Ω (at 25°C)

Maximum Winding Temperature: 125°C / 257°F

Maximum Discharge Temperature: 130°C / 266°F

Additional Notes: Very good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake. Special design for high refrigerant charge.

Refrigerant(s): R134a, R513A

Displacement: 4 cm³ / 0,24 cu.in

Compressors on Pallet: 100

Image of the SECOP FRK-Series compressor. It is a black, cylindrical unit with a silver label.

General Configurations with FRK5G

Feature Conf. 1 Conf. 2
Motor Configuration CSIR CSIR
Power Supply (Nominal) 220-240V/50Hz 208-230V/60Hz
Number of Phases 1 1
Voltage Range 187-254V 198-253V
Approvals VDE, CB, UL VDE, CB, UL
Starting Torque HST HST
Note Electrical equipment is included and pre-assembled to compressor.

Applications with FRK5G

Feature Conf. 1 Conf. 2
Refrigerant R134a R134a
Application LBP+MBP+HBP LBP+MBP
System Cooling static static
Hot Gas Defrost OK OK
Long Interval Pull Down OK OK

Electrical Data - Configurations with FRK5G

Feature Conf. 1 Conf. 2
Starting Device Type relay relay
Run Capacitor -/- -/-
Start Capacitor 80 µF 80 µF
LRA (Locked Rotor Amps / 4s/ U(N)) 10,5 A -/- A
RLA (Rated Load Amps / 1s/ U(N)) 1 A -/- A
Cut In Current (U(N)) 10,2 A -/- A

Compressor Dimensions

Housing Dimensions

A Height: 182 mm / 7,17 in

B Height: 175 mm / 6,89 in

C Length Shell: 198 mm / 7,8 in

D Length w. Cover: 238 mm / 9,37 in

E Width: 160 mm / 6,3 in

Connectors

Feature Suction (X) Discharge (Y) Process (Z)
Diameter (inside, outside) [mm] øi 6,16-6,24 øi 5,1-5,2 øi 6,11-6,29
Diameter (inside, outside) [in] øi 0,24-0,25 øi 0,2-0,2 øi 0,24-0,25
Material copper copper copper
Horizontal Angle +2° 35°
Vertical Angle +2° 30° 145°
Position l/h/w [mm] 119/73/59 117/107/66 -88/101/71
Position l/h/w [in] 4,7/2,9/2,3 4,6/4,2/2,6 -3,5/4/2,8
Straight Tube Length [mm] 14 14 14
Straight Tube Length [in] 0,5 0,5 0,5
Diagram showing compressor external view with dimensions and connection port labels (A, B, C, D, E, Z, Y, X, h, vertical angle, horizontal angle, l, w).

Compressor Fixation

Diagram illustrating compressor fixation methods: bolt joint and snap-on, with associated dimensions. The bolt joint shows compressor base, bolts, washers, and rubber grommets. The snap-on shows clips and a steel pin.

Baseplate Dimensions

Label [mm] [inch]
BI 204 8.03
Bw 132 5.2
ØE Ø 9.7 Ø 0.38

Large Holes

Label [mm] [inch]
LI 165 6.5
Lw 101.6 4
ØL Ø 19 Ø 0.75

Small Holes

Label [mm] [inch]
SI 170 6.7
Sw 70 2.76
ØS Ø 16 Ø 0.63

Mounting Accessories

Application Notes: Provision for PE Grounding is located at the PE Stamp on the compressor. Suction gas connector and Process connector can be switched (minor loss of cooling capacity).

Configuration Details (Conf. 1: 220-240V/50Hz)

Motor Configuration: CSIR

Power Supply (Nominal): 220-240V/50Hz 1~

Refrigerant: R134a

Application: LBP+MBP+HBP

Voltage Range: 187-254V

Starting Torque: HST

Approvals: VDE, CB, UL

Electrical accessories and wiring diagram for the compressor, showing components like current relay, start capacitor, and cover/clamp assembly.

Ambient/Machine Room Temperatures (Min/Max)

Ambient Temperature Range: 10 - 43°C / 50 - 110°F

Machine Room Temperature Range: 10 - 48°C / 50 - 119°F

Compressor Cooling: static

Operation Pressure Range

Graph showing the operation pressure range for condensing pressure vs. evaporating pressure, indicating continuous and transitory operation limits. The graph plots pressure in bar against temperature in °C and °F.

Components (Included and Pre-assembled)

Alternative Components

Optimization + Standard Conditions (Conf. 1: 220-240V/50Hz)

Conditions: R134a, 220V/50Hz, CSIR, static, VDE, CB, UL

Conditions Evaporating Pressure (Saturation Temperature) Condensing Pressure (Saturation Temperature) Power Consumption Ref. Mass Flow [kg/h]
pe [°C] pe [°F] RGT [°C] Tliq [°C] pc [°C] pc [°F] Cooling Capacity [W] [Btu/h] [kcal/h] COP [W/W] EER [Btu/Wh] [kcal/Wh] P1 [W] I [A]
ASHRAE LBP -23 -10 32 32 54 130 98,4 336 84,7 1,11 3,79 0,96 88,6 0,91 1,91
ASHRAE MBP -7 20 35 46 54 130 215,0 734 185,1 1,72 5,86 1,48 125,3 1,00 4,69
ASHRAE HBP 7,2 45 35 46 54 130 386,4 1320 332,5 2,50 8,54 2,15 154,5 1,07 8,57
EN12900 LBP -35 -31 20 40 40 104 44,6 152 38,4 0,68 2,34 0,59 65,1 0,86 0,98
EN12900 MBP -10 14 20 45 45 113 185,6 634 159,7 1,69 5,77 1,45 109,8 0,96 4,34
EN12900 HBP 5 41 20 50 50 122 329,2 1124 283,3 2,29 7,82 1,97 143,8 1,04 8,30

Performance Tables (Conf. 1: 220-240V/50Hz)

Conditions: R134a, 220V/50Hz, CSIR, static, VDE, CB, UL

Conditions pe Cooling Capacity COP EER Power Consumption Ref. Mass Flow [kg/h]
[°C] [°F] [W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [Btu/Wh] [kcal/Wh] P1 [W] I [A]
cond. pressure pc= 45/113
return gas temp. RGT= 32/90
liquid temp Tliq= 45/113
-35 -31 42,1 144 36,2 0,65 2,22 0,56 - - 64,8 0,86 0,91
-25 -13 84,2 287 72,4 1,02 3,47 0,87 - - 82,8 0,90 1,82
-15 5 149,6 511 128,8 1,48 5,07 1,28 - - 100,8 0,94 3,26
-10 14 192,5 657 165,7 1,75 5,99 1,51 - - 109,8 0,96 4,21
0 32 301,6 1030 259,6 2,36 8,06 2,03 - - 127,8 1,00 6,67
5 41 369,0 1260 317,5 2,70 9,21 2,32 - - 136,8 1,02 8,21
15 59 532,1 1817 457,9 3,44 11,74 2,96 - - 154,9 1,08 12,05
cond. pressure pc= 55/131
return gas temp. RGT= 32/90
liquid temp Tliq= 55/131
-35 -31 34,3 117 29,6 0,56 1,91 0,48 - - 61,4 0,86 0,82
-25 -13 71,6 244 61,6 0,84 2,88 0,73 - - 84,8 0,91 1,71
-15 5 128,5 439 110,6 1,20 4,08 1,03 - - 107,5 0,95 3,09
-10 14 165,7 566 142,6 1,40 4,77 1,20 - - 118,5 0,98 4,01
0 32 260,7 890 224,3 1,86 6,35 1,60 - - 140,1 1,03 6,38
5 41 319,6 1091 275,0 2,12 7,24 1,83 - - 150,6 1,06 7,87
15 59 463,0 1581 398,4 2,70 9,23 2,33 - - 171,3 1,13 11,63

Configuration Details (Conf. 2: 208-230V/60Hz)

Motor Configuration: CSIR

Power Supply (Nominal): 208-230V/60Hz 1~

Refrigerant: R134a

Application: LBP+MBP

Voltage Range: 198-253V

Starting Torque: HST

Approvals: VDE, CB, UL

Electrical accessories and wiring diagram for the compressor, showing components like current relay, start capacitor, and cover/clamp assembly.

Ambient/Machine Room Temperatures (Min/Max)

Ambient Temperature Range: 10 - 43°C / 50 - 110°F

Machine Room Temperature Range: 10 - 48°C / 50 - 119°F

Compressor Cooling: static

Operation Pressure Range

Graph showing the operation pressure range for condensing pressure vs. evaporating pressure, indicating continuous and transitory operation limits. The graph plots pressure in bar against temperature in °C and °F.

Components (Included and Pre-assembled)

Alternative Components

Optimization + Standard Conditions (Conf. 2: 208-230V/60Hz)

Conditions: R134a, 230V/60Hz, CSIR, static, VDE, CB, UL

Conditions Evaporating Pressure (Saturation Temperature) Condensing Pressure (Saturation Temperature) Power Consumption Ref. Mass Flow [kg/h]
pe [°C] pe [°F] RGT [°C] Tliq [°C] pc [°C] pc [°F] Cooling Capacity [W] [Btu/h] [kcal/h] COP [W/W] EER [Btu/Wh] [kcal/Wh] P1 [W] I [A]
ASHRAE LBP -23 -10 32 32 54 130 119,2 407 102,6 1,17 3,98 1,00 102,2 1,10 2,32
ASHRAE MBP -7 20 35 46 54 130 253,7 866 218,3 1,77 6,03 1,52 143,7 1,19 5,53
ASHRAE HBP 7,2 45 35 46 54 130 451,2 1541 388,3 2,50 8,54 2,15 180,3 1,28 10,01
EN12900 LBP -35 -31 20 40 40 104 53,4 182 45,9 0,71 2,41 0,61 75,6 1,06 1,17
EN12900 MBP -10 14 20 45 45 113 217,7 744 187,4 1,71 5,85 1,47 127,2 1,15 5,10
EN12900 HBP 5 41 20 50 50 122 383,8 1311 330,3 2,27 7,74 1,95 169,4 1,25 9,67

Performance Tables (Conf. 2: 208-230V/60Hz)

Conditions: R134a, 230V/60Hz, CSIR, static, VDE, CB, UL

Conditions pe Cooling Capacity COP EER Power Consumption Ref. Mass Flow [kg/h]
[°C] [°F] [W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [Btu/Wh] [kcal/Wh] P1 [W] I [A]
cond. pressure pc= 45/113
return gas temp. RGT= 32/90
liquid temp Tliq= 45/113
-35 -31 49,3 168 42,5 0,66 2,27 0,57 - - 74,4 1,06 1,06
-25 -13 101,4 346 87,3 1,07 3,65 0,92 - - 94,9 1,09 2,20
-15 5 176,9 604 152,3 1,52 5,20 1,31 - - 116,2 1,13 3,86
-10 14 225,9 771 194,4 1,78 6,06 1,53 - - 127,2 1,15 4,94
0 32 351,1 1199 302,1 2,33 7,97 2,01 - - 150,4 1,20 7,76
5 41 429,3 1466 369,4 2,64 9,01 2,27 - - 162,6 1,23 9,56
15 59 621,6 2123 534,9 3,29 11,25 2,83 - - 188,7 1,30 14,08
cond. pressure pc= 55/131
return gas temp. RGT= 32/90
liquid temp Tliq= 55/131
-35 -31 37,7 129 32,5 0,51 1,74 0,44 - - 74,0 1,06 0,90
-25 -13 86,8 296 74,7 0,88 3,01 0,76 - - 98,5 1,10 2,07
-15 5 153,9 526 132,4 1,25 4,27 1,08 - - 123,2 1,14 3,70
-10 14 196,7 672 169,2 1,45 4,95 1,25 - - 135,7 1,17 4,76
0 32 305,4 1043 262,9 1,89 6,46 1,63 - - 161,5 1,23 7,47
5 41 373,4 1275 321,3 2,14 7,29 1,84 - - 174,9 1,26 9,20
15 59 541,3 1849 465,8 2,67 9,12 2,30 - - 202,8 1,35 13,60

PDF preview unavailable. Download the PDF instead.

frk5g 106g5463 r134a 220v 208v 50hz 60hz 08-2025 ds Microsoft Excel für Microsoft 365

Related Documents

Preview SECOP FRK5G Compressor Technical Data Sheet
Comprehensive technical data for the SECOP FRK5G compressor, including specifications, performance tables, and application notes for R134a refrigerant.
Preview Secop KLE4.0GFTX Compressor Technical Data Sheet
Comprehensive technical data, specifications, and performance tables for the Secop KLE4.0GFTX compressor, including details on configurations, dimensions, electrical data, and operating pressure ranges for R134a refrigerant.
Preview SECOP KLE8.6GFTX Compressor Technical Data Sheet
Detailed technical specifications, configurations, performance data, and dimensions for the SECOP KLE8.6GFTX compressor, supporting R134a and R513A refrigerants for various voltage and frequency combinations.
Preview SECOP KLE4.8GFTX Compressor Technical Data and Specifications
Comprehensive technical data sheet for the SECOP KLE4.8GFTX compressor. Details include compressor design specifications, general configurations (Conf. 1 & 2), application suitability (LBP, MBP, HBP), electrical data, dimensions, mounting accessories, ambient temperature limits, operation pressure ranges, and detailed performance data under various standard conditions (ASHRAE, EN12900) for both 220-240V/50Hz and 208-230V/60Hz operation. Features R134a and R513A refrigerants.
Preview SECOP KLE4.8GFTX Compressor Technical Data Sheet
Detailed technical specifications, dimensions, electrical data, and performance tables for the SECOP KLE4.8GFTX compressor, designed for R134a refrigerant, covering configurations for 220-240V/50Hz and 208-230V/60Hz.
Preview Secop SC12GH Compressor Technical Data and Specifications
Comprehensive technical data for the Secop SC12GH compressor, including electrical specifications, performance tables, dimensions, and application notes for various configurations and refrigerants.
Preview SECOP KLE4.0GFTX Compressor Technical Data
Detailed technical specifications, dimensions, electrical data, and performance tables for the SECOP KLE4.0GFTX compressor, designed for R134a refrigerant and operating on 220-240V/50Hz and 208-230V/60Hz power supplies.
Preview Secop NL6.1MF Compressor Technical Data and Specifications
Detailed technical specifications, configurations, electrical data, and performance tables for the Secop NL6.1MF compressor, including operating limits and wiring diagrams.