Secop Compressor Technical Data
Model: KLE4.0GFTX
General Information
Designation: KLE4.0GFTX
Sales Code: 106G5418
Configurations: 220-240V/50Hz 1~ and 208-230V/60Hz 1~
Compressor Design
Oil Type: Polyolester
Oil Viscosity: 19,2 cSt
Oil Quantity: 240 cm³ / 8,1 fl.oz
Refrigerant Charge (Tech. Limit): 250g / 8,8oz
Free Gas Volume (Comp.): 1560 cm³ / 52,7 fl.oz
Weight: 8,9kg / 19,6lbs
Motor Protection: External
Winding Resistance (Main): 13,1 Ω (at 25°C)
Winding Resistance (Aux): 25,3 Ω (at 25°C)
Max. Winding Temp.: 125°C / 257°F
Max. Discharge Temp.: 130°C / 266°F
Additional Note: Good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake.
A SECOP KL-Series compressor unit is depicted.
General Configurations
Feature | Conf. 1 (220-240V/50Hz) | Conf. 2 (208-230V/60Hz) |
---|---|---|
Motor Configuration | CSIR | CSIR |
Power Supply (Nominal) | 220-240V/50Hz | 208-230V/60Hz |
Number of Phases | 1 | 1 |
Voltage Range | 187-254V | 198-253V |
Approvals | VDE, CB, UL | VDE, CB, UL |
Starting Torque | HST | HST |
Note | Electrical equipment is included and pre-assembled to compressor. |
Applications
Feature | Conf. 1 | Conf. 2 |
---|---|---|
Refrigerant | R134a | R134a |
Application | LBP+MBP+HBP | LBP+MBP |
System Cooling | Static | Static |
Hot Gas Defrost | OK | OK |
Long Interval Pull Down | OK | OK |
Electrical Data
Feature | Conf. 1 | Conf. 2 |
---|---|---|
Starting Device Type | Relay | Relay |
Run Capacitor | -/- | -/- |
Start Capacitor | 80µF | 80µF |
LRA (Locked Rotor Amps / 4s/ U(N)) | 10,5A | 10,5A |
RLA (Rated Load Amps / 1s/ U(N)) | 1A | 1A |
Cut In Current (U(N)) | 10,2A | 10,2A |
Compressor Dimensions
Housing Dimensions:
- A Height: 174mm / 6,85in
- B Height: 167mm / 6,57in
- C Length Shell: 194mm / 7,64in
- D Length w. Cover: 235,1mm / 9,26in
- E Width: 151mm / 5,94in
Diagram shows compressor dimensions labeled A through E.
Connectors
Feature | Connector Type | ||
---|---|---|---|
Suction (X) | Discharge (Y) | Process (Z) | |
Diameter [mm] (i:inside, o:outside) | øi 8,11-8,29 | øi 6,11-6,29 | øi 6,11-6,29 |
Diameter [in] (i:inside, o:outside) | øi 0,32-0,33 | øi 0,24-0,25 | øi 0,24-0,25 |
Material | Copper | Copper | Copper |
Horizontal Angle | +2° | 35° | 0° |
Vertical Angle | +2° | 30° | 40° |
Position [mm] (l/h/w) | 119/73/59 | 114/107/63 | -87/101/71 |
Position [in] (l/h/w) | 4,7/2,9/2,3 | 4,5/4,2/2,5 | -3,4/4/2,8 |
Straight Tube Length [mm] | 14 | 14 | 14 |
Straight Tube Length [in] | 0,5 | 0,5 | 0,5 |
Diagram illustrates connector positions (X, Y, Z) and angles relative to the compressor body (A, B, C, D, E, W).
Compressor Fixation and Mounting Accessories
Compressor Fixation:
The compressor can be fixed using bolt joints or snap-on mechanisms.
- Bolt Joint: M6 | Ø16mm (Part No. 118-1917)
- Bolt Joint: Ø1/4" | Ø16mm (Part No. 118-1946)
- Snap-on: Ø7,3 | Ø16mm (Part No. 118-1947)
Mounting Accessories (Multi Pack):
- Part No. 118-1918
- Part No. 118-1919
Baseplate Dimensions:
- Bl: 204mm / 8.03in
- Bw: 100mm / 3.94in
- Small holes (Sl): 170mm / 6.7in
- Small holes (Sw): 70mm / 2.76in
- ØS: 178mm / 7in
- ØS: Ø 16mm / Ø 0.63in
Diagrams show bolt joint fixation with washer and rubber grommet, and snap-on fixation with clip and steel pin.
Application Notes
- Housing with dip-tray fixture (omega bracket).
- Compressor with low height version.
- Provision for PE Grounding is located at the PE Stamp on the compressor.
Ambient and Machine Room Temperatures
Ambient Temperature Range: 10 - 43°C / 50 - 110°F
Machine Room Temperature Range: 10 - 48°C / 50 - 119°F
Compressor Cooling: Static
Operation Pressure Range
Graph displays the operation pressure range for the compressor. The Y-axis shows condensing pressure (in bara and saturated temperature °C/°F), and the X-axis shows evaporation pressure (in bara and saturated temperature °C/°F). Two curves represent continuous and transitory operation.
Electrical Accessories / Wiring Diagram
Diagram shows electrical accessories and wiring for the compressor. Key components include:
- a5: Current relay (T1189/L6-S3) - Part No. 117U7073
- c: Start capacitor (80µF, 6.3mm) - Part No. 117U5001
- b, d: Cover + clamp + screws (5VA-compl.) - Part No. 103N0600
- b, d: 100x cover + clamp + screws (5VA) - Part No. 103N2060
- b, d: Cover + clamp + screws (5VA) in bag - Part No. 103N1060
Optimization and Standard Conditions
Performance data is provided for R134a refrigerant under various conditions (evaporating and condensing pressures, return gas temperature, liquid temperature) for both 220-240V/50Hz and 208-230V/60Hz configurations.
Configuration 1: 220-240V/50Hz
Optimization + Standard Conditions
Conditions | Cooling Capacity | COP | Power Consumption | Current [A] | Ref. Mass Flow [kg/h] | Application Standard | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | P1 | |||||
Evaporating [°C/°F] Condensing [°C/°F] RGT [°C/°F] Tliq [°C/°F] |
-23 / -10 54 / 130 32 / 90 32 / 90 |
101,4 | 346 | 87,3 | 1,14 | 3,90 | 0,98 | 88,8 | 1,15 | 1,97 | ASHRAE LBP | |
-7 / 20 54 / 130 35 / 95 46 / 115 |
221,7 | 757 | 190,8 | 1,77 | 6,03 | 1,52 | 125,5 | 1,23 | 4,84 | ASHRAE MBP | ||
7,2 / 45 54 / 130 35 / 95 46 / 115 |
398,3 | 1360 | 342,8 | 2,58 | 8,81 | 2,22 | 154,4 | 1,31 | 8,84 | ASHRAE HBP | ||
-35 / -31 40 / 104 20 / 68 40 / 104 |
46,0 | 157 | 39,6 | 0,72 | 2,47 | 0,62 | 63,5 | 1,10 | 1,01 | EN12900 LBP | ||
-10 / 14 45 / 113 20 / 68 45 / 113 |
191,3 | 653 | 164,6 | 1,74 | 5,93 | 1,49 | 110,1 | 1,20 | 4,48 | EN12900 MBP | ||
5 / 41 50 / 122 20 / 68 50 / 122 |
339,4 | 1159 | 292,1 | 2,36 | 8,07 | 2,03 | 143,6 | 1,28 | 8,55 | EN12900 HBP |
Performance Tables
Conditions | Cooling Capacity | COP | Power Consumption | Current [A] | Ref. Mass Flow [kg/h] | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | P1 | ||||
Cond. Pressure [°C/°F] pc= 45/113 Return Gas Temp. [°C/°F] RGT= 32/90 Liquid Temp. [°C/°F] Tliq= 45/113 |
-35 / -31 -25 / -13 -15 / 5 -10 / 14 0 / 32 5 / 41 15 / 59 |
43,4 86,8 154,2 198,5 310,9 380,4 548,6 |
148 296 527 678 1062 1299 1874 |
37,4 74,7 132,7 170,8 267,6 327,4 472,1 |
0,69 1,05 1,52 1,80 2,43 2,78 3,54 |
2,34 3,57 5,20 6,15 8,31 9,51 12,09 |
0,59 0,90 1,31 1,55 2,09 2,40 3,05 |
63,3 82,9 101,2 110,1 127,7 136,6 154,9 |
1,10 1,14 1,18 1,20 1,24 1,26 1,31 |
0,94 1,88 3,36 4,34 6,88 8,47 12,43 |
|
Cond. Pressure [°C/°F] pc= 55/131 Return Gas Temp. [°C/°F] RGT= 32/90 Liquid Temp. [°C/°F] Tliq= 55/131 |
-35 / -31 -25 / -13 -15 / 5 -10 / 14 0 / 32 5 / 41 15 / 59 |
35,4 73,8 132,4 170,8 268,7 329,4 477,3 |
121 252 452 583 918 1125 1630 |
30,5 63,5 114,0 147,0 231,3 283,5 410,8 |
0,59 0,87 1,23 1,44 1,92 2,19 2,78 |
2,01 2,97 4,19 4,91 6,55 7,48 9,50 |
0,51 0,75 1,06 1,24 1,65 1,88 2,40 |
60,0 84,9 107,8 118,8 140,0 150,5 171,5 |
1,10 1,15 1,19 1,22 1,27 1,30 1,36 |
0,84 1,76 3,19 4,13 6,57 8,12 11,99 |
Configuration 2: 208-230V/60Hz
Optimization + Standard Conditions
Conditions | Cooling Capacity | COP | Power Consumption | Current [A] | Ref. Mass Flow [kg/h] | Application Standard | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | P1 | |||||
Evaporating [°C/°F] Condensing [°C/°F] RGT [°C/°F] Tliq [°C/°F] |
-23 / -10 54 / 130 32 / 90 32 / 90 |
122,9 | 420 | 105,8 | 1,20 | 4,10 | 1,03 | 102,4 | 1,10 | 2,39 | ASHRAE LBP | |
-7 / 20 54 / 130 35 / 95 46 / 115 |
261,5 | 893 | 225,1 | 1,81 | 6,20 | 1,56 | 144,1 | 1,19 | 5,71 | ASHRAE MBP | ||
7,2 / 45 54 / 130 35 / 95 46 / 115 |
465,1 | 1589 | 400,3 | 2,58 | 8,82 | 2,22 | 180,1 | 1,28 | 10,32 | ASHRAE HBP | ||
-35 / -31 40 / 104 20 / 68 40 / 104 |
55,1 | 188 | 47,4 | 0,76 | 2,59 | 0,65 | 72,7 | 1,06 | 1,21 | EN12900 LBP | ||
-10 / 14 45 / 113 20 / 68 45 / 113 |
224,4 | 767 | 193,2 | 1,76 | 6,00 | 1,51 | 127,8 | 1,15 | 5,25 | EN12900 MBP | ||
5 / 41 50 / 122 20 / 68 50 / 122 |
395,7 | 1351 | 340,6 | 2,34 | 7,98 | 2,01 | 169,3 | 1,25 | 9,97 | EN12900 HBP |
Performance Tables
Conditions | Cooling Capacity | COP | Power Consumption | Current [A] | Ref. Mass Flow [kg/h] | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [W/W] | [Btu/Wh] | [kcal/Wh] | [W] | P1 | ||||
Cond. Pressure [°C/°F] pc= 45/113 Return Gas Temp. [°C/°F] RGT= 32/90 Liquid Temp. [°C/°F] Tliq= 45/113 |
-35 / -31 -25 / -13 -15 / 5 -10 / 14 0 / 32 5 / 41 15 / 59 |
50,9 104,5 182,4 232,9 361,9 442,5 640,8 |
174 357 623 795 1236 1511 2188 |
43,8 90,0 157,0 200,4 311,5 380,8 551,5 |
0,71 1,10 1,56 1,82 2,40 2,72 3,40 |
2,42 3,77 5,33 6,22 8,21 9,29 11,60 |
0,61 0,95 1,34 1,57 2,07 2,34 2,92 |
71,8 94,7 116,8 127,8 150,6 162,6 188,7 |
1,06 1,09 1,13 1,15 1,20 1,23 1,30 |
1,10 2,26 3,98 5,10 8,00 9,85 14,51 |
|
Cond. Pressure [°C/°F] pc= 55/131 Return Gas Temp. [°C/°F] RGT= 32/90 Liquid Temp. [°C/°F] Tliq= 55/131 |
-35 / -31 -25 / -13 -15 / 5 -10 / 14 0 / 32 5 / 41 15 / 59 |
38,9 89,4 158,6 202,7 314,9 385,0 558,0 |
133 305 542 692 1075 1315 1906 |
33,5 77,0 136,5 174,5 271,0 331,3 480,3 |
0,54 0,91 1,28 1,49 1,95 2,20 2,76 |
1,85 3,10 4,38 5,08 6,66 7,53 9,41 |
0,47 0,78 1,10 1,28 1,68 1,90 2,37 |
71,7 98,4 123,7 136,2 161,6 174,7 202,5 |
1,06 1,10 1,14 1,17 1,23 1,26 1,34 |
0,93 2,14 3,82 4,90 7,70 9,49 14,02 |