Secop SC12GH Compressor
Model: SC12GH
Sales Code: 104G8261
Single Pack Information
Single Pack Code: 195B4222
Position | Title | Code | Quantity |
---|---|---|---|
1 | Compressor SC12GH | 10468261 | 1 |
2 | Starting relay | 11706011 | 1 |
3 | Starting capacitor (80µF 220V, 6.3mm) | 117U5017 | 1 |
4 | Cord relief | 103N1004 | 1 |
5 | Cover | 103N2008 | 1 |
6 | Bolt joint for one compressor | M6 | ø16mm | 118-1917 | 1 |
Technical Data - General
Model Designation: SC12GH
Configurations: 220-240V/50Hz 1~ and 208-230V/60Hz 1~
Compressor Design
- Oil type: Polyolester
- Oil viscosity: 22cST
- Oil quantity: 504cm³ / 17fl.oz
- Refrigerant charge - tech. limit: 1300g / 45,9oz
- Free gas volume comp.: 1510cm³ / 51,1fl.oz
- Weight: 12,5kg / 27,6lbs
- Motor protection: 1# internal
- Winding resistance main: 4,40 (at 25°C)
- Winding resistance aux: 140 (at 25°C)
- Max. winding temp.: 125°C / 257°F
- Max. discharge temp.: 130°C / 266°F
Refrigerants and Displacement
- Refrigerant(s): R134a, R513A
- Displacement: 12,87cm³ / 0,79cu.in
- Compressors on pallet: 80
General Configurations
Parameter | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 |
---|---|---|---|---|
Motorconfiguration | CSIR | CSIR | CSIR | CSIR |
Power supply (nominal) | 220-240V/50Hz | 220-240V/50Hz | 208-230V/60Hz | 208-230V/60Hz |
Number of phases | 1 | 1 | 1 | 1 |
Voltage range | 198-254V | 198-254V | 198-254V | 198-254V |
Approvals | VDE, UL, KC | VDE, UL | VDE, UL, KC | VDE, UL |
Starting torque | HST | HST | HST | HST |
Applications
Parameter | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 |
---|---|---|---|---|
Refrigerant | R134a | R513A | R134a | R513A |
Application | HBP | HBP | HBP | HBP |
System cooling | fan 3m/s | fan 3m/s | fan 3m/s | fan 3m/s |
Hot gas defrost | OK | OK | OK | OK |
Long interval pull down | OK | OK | OK | OK |
Electrical Data
Parameter | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 |
---|---|---|---|---|
Starting device type | relay | relay | relay | relay |
Run capacitor | -/- | -/- | -/- | -/- |
Start capacitor | 80µF | 80µF | 80µF | 80µF |
LRA (locked rotor amps / 4s) | 19A | 19A | 18,3A | 18,3A |
RLA (rated load amps / 1s) | 3,9A | 3,9A | 3,52A | 3,52A |
Cut in current | 19A | 19A | 18,3A | 18,3A |
Compressor Dimensions
Housing Dimensions
- A Height: 209mm / 8,23in
- B Height: 203mm / 7,99in
- C Length shell: 218mm / 8,58in
- D Length w. cover: 255mm / 10,04in
- E Width: 151mm / 5,94in
Connectors
Parameter | Suction (X) | Discharge (Y) | Process (Z) |
---|---|---|---|
Diameter [mm] (i:inside, o:outside) | øi 10,11-10,29 | øi 8,11-8,29 | øi 6,11-6,29 |
Diameter [in] (i:inside, o:outside) | øi 0,4-0,41 | øi 0,32-0,33 | øi 0,24-0,25 |
Material | copper | copper | copper |
Horizontal angle | +2° | 37° | 143° |
Vertical angle | +2° | 30° | 0° |
Position I/h/w [mm] | 107/183/55 | 115/100/63 | -107/183/55 |
Position I/h/w [in] | 4,2/7,2/2,2 | 4,5/3,9/2,5 | -4,2/7,2/2,2 |
Straight tube l. [mm] | 12 | 12 | 12 |
Straight tube l. [in] | 0,5 | 0,5 | 0,5 |
Compressor Fixation
Diagrams illustrating compressor fixation points and dimensions are provided.
Mounting Accessories
Accessory | One Comp. Code | Multi Pack Code |
---|---|---|
Bolt joint | M6 | ø16mm | 118-1917 | 118-1918 |
Bolt joint | ø1/4" | ø16mm | 118-1946 | 118-1949 |
Bolt joint | ø1/4" | ø19mm | 118-1949 | 118-1919 |
Snap-on | ø7,3 | Ø16mm | 118-1947 | 118-1919 |
Application notes: Provision for PE Grounding is located at the PE Stamp on the compressor.
Performance Data
Detailed performance tables are provided for various configurations and operating conditions, including cooling capacity, COP, EER, power consumption (P1), current consumption (A), and refrigerant mass flow (m).
Configuration 1: R134a, 220V/50Hz, CSIR
Tables show performance under different evaporating and condensing pressures, return gas temperatures, and liquid temperatures.
Configuration 2: R513A, 220V/50Hz, CSIR
Tables show performance under different evaporating and condensing pressures, return gas temperatures, and liquid temperatures.
Configuration 3: R134a, 208-230V/60Hz, CSIR
Tables show performance under different evaporating and condensing pressures, return gas temperatures, and liquid temperatures.
Configuration 4: R513A, 208-230V/60Hz, CSIR
Tables show performance under different evaporating and condensing pressures, return gas temperatures, and liquid temperatures.
Operation Limits and Pressure Ranges
Graphical representations of operation pressure ranges are provided, illustrating continuous and transitory operation zones based on evaporating and condensing pressures.
Electrical Accessories / Wiring Diagram
Wiring diagrams are included for the CSIR motor configuration, showing the connections for the relay, start capacitor, cord relief, and plastic cover.
- Components:
- a2: relay (117U6011)
- c: start capacitor (80µF) (117U5017)
- d: cord relief (103N1004)
- b: plastic cover (103N2008)
Ambient/Machine Room Temperatures
- Ambient temperature range: 10-43°C / 50-110°F
- Machine room temperature range: 10-48°C / 50-119°F
- Compressor cooling: fan 3m/s
Service/Repair Information (R290)
Information regarding service and repair for R290 refrigerant is provided, including safety warnings.
Safety Warning: A triangle warning symbol with "R290" indicates a potential hazard.
Handling Instructions: Diagrams show correct and incorrect methods for handling refrigerant lines, with a checkmark [✔️] indicating the correct procedure and a cross [❌] indicating the incorrect procedure.