Product Overview
Part Number: SFP-10G-T-301
A clear, high-resolution image of the FS SFP-10G-T-301 transceiver, showing its compact RJ-45 connector and SFP+ interface.
Application
- 10 Gigabit Ethernet over Cat6a Cable
- Up to 30m Reach over Cat6a Cable
Features
- Support 10GBASE-T on Line Port
- Support 10GBASE-R on Host Port
- Hot-pluggable SFP Footprint
- Compact RJ-45 Connector Assembly
- RoHS Compliant
- Single +3.3V Power Supply
- Lower Power Consumption
- Industrial Temperature Range: -40 ~85°C
Description
The 10GBASE-T SFP+ Copper RJ-45 transceiver provides 10GBASE-T throughput up to 30m over cat6a/cat7 copper cable via RJ-45 connector. This transceiver is compliant with IEEE 802.3an, IEEE 802.3az, SFF-8431 and SFP+ MSA. Each SFP+ transceiver module is individually tested to be used on a series of switches, routers, servers, network interface card (NICs) etc. Featuring an operating temperature range of -40 to 85°C, this industrial transceiver can work in harsh industrial environments, such as telecommunication, data processing & management, the application of industrial and factory automation, outdoor applications, rail and intelligent transportation systems (ITSs), marine, oil and gas, mining etc.
Product Specifications
Parameter | Symbol | Min | Typ. | Max | Unit | Notes/Conditions |
---|---|---|---|---|---|---|
Bit Rate | BR | 10 | Gb/sec | IEEE 802.3 compatible. See Notes 1 below |
Notes: 1. Clock tolerance is +/- 50 ppm
Environmental Specifications
Parameter | Symbol | Min | Typ. | Max | Unit | Notes/Conditions |
---|---|---|---|---|---|---|
Operating Temperature | Top | -40 | 85 | °C | I Temp | |
Storage Temperature | Tsto | -40 | 85 | °C | Ambient temperature |
Transmission Distances
Line Port | Cable | Reach | Host Port |
---|---|---|---|
10GBASE-T | Cat6a/Cat7 | 30m | 10GBase-R |
Electrical Characteristics
Low-Speed Signals, Electronic Characteristics
Parameter | Symbol | Min | Max | Unit | Notes/Conditions |
---|---|---|---|---|---|
SFP Output LOW | VOL | 0 | 0.5 | V | 4.7k to 10k pull-up to host_Vcc, measured at host side of connector |
SFP Output HIGH | VOH | host_Vcc -0.5 | host_Vcc + 0.3 | V | 4.7k to 10k pull-up to host_Vcc, measured at host side of connector |
SFP Input LOW | VIL | 0 | 0.8 | V | 4.7k to 10k pull-up to Vcc, measured at SFP side of connector |
SFP Input HIGH | VIH | 2 | Vcc + 0.3 | V | 4.7k to 10k pull-up to Vcc, measured at SFP side of connector |
Notes: 1. MOD_DEF(1) (SCL) and MOD_DEF(2) (SDA), are open drain CMOS signals (see section VII, "Serial Communication Protocol"). 2. Both MOD_DEF(1) and MOD_DEF(2) must be pulled up to host_Vcc
Electrical Power Interface
Parameter | Symbol | Min | Typ. | Max | Unit | Notes/Conditions |
---|---|---|---|---|---|---|
Supply Current | Is | 570 | 820 | mA | 2.7W max power over full range of voltage and temperature. See caution Notes below. | |
Input Voltage | Vcc | 3.13 | 3.3 | 3.47 | V | Referenced to GND |
Maximum Voltage | Vmax | 4 | V | |||
Surge Current | Isurge | TBD | mA | Hot plug above steady statecurrent. See caution notebelow. |
Notes: 1. The SFP+-10GBASE-T has an input voltage range of 3.3 V +/- 5%. The 4V maximum voltage is not allowed for continuous operation. 2. Power consumption and surge current are higher than the specified values in the SFP MSA.
High-Speed Electrical Interface
High-Speed Electrical Interface, Transmission Line-SFP
Parameter | Symbol | Min | Typ. | Max | Unit | Notes/Conditions |
---|---|---|---|---|---|---|
Line Frequency | fL | 125 | MHz | 5-level encoding, per IEEE 802.3 | ||
Tx Output Impedance | Zout,TX | 100 | Ohm | Differential, for all frequencies between 1MHz and 125MHz | ||
Rx Input Impedance | Zin,RX | 100 | Ohm | Differential, for all frequencies between 1MHz and 125MHz |
High-Speed Electrical Interface, Host-SFP
Parameter | Symbol | Min | Typ. | Max | Unit | Notes/Conditions |
---|---|---|---|---|---|---|
Single Ended Data Inputswing | Vinsing | 250 | 1200 | mV | Single ended | |
Single Ended Data Outputswing | Voutsing | 350 | 800 | mV | Single ended | |
Rise/Fall Time | Tr,Tf | 175 | psec | 20%-80% | ||
Tx Input Impedance | Zin | 50 | Ohm | Single ended | ||
Rx Output Impedance | Zout | 50 | Ohm | Single ended |
Notes: 1. All high-speed signals are AC-coupled internally.
Serial Communication Protocol
All FS.COM SFPs support the 2-wire serial communication protocol outlined in the SFP MSA. These SFPs use an MCU, can be accessed with address of A0h.
Parameter | Symbol | Min | Typ. | Max | Unit | Notes/Conditions |
---|---|---|---|---|---|---|
I²C Clock Rate | 0 | 200,000 | Hz | Serial Bus Timing, Requirements |
Pin Description
Pin | Symbol | Name/Description | Ref. |
---|---|---|---|
1 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |
2 | TFAULT | Transmitter Fault. Not supported. | 2 |
3 | TDIS | Transmitter Disable. Laser output disabled on high or open. | 2 |
4 | MOD_DEF(2) | Module Definition 2. Data line for Serial ID. | 3 |
5 | MOD_DEF(1) | Module Definition 1. Clock line for Serial ID. | 3 |
6 | MOD_DEF(0) | Module Definition 0. Grounded within the module. | 3 |
7 | Rate Select | No connection required | |
8 | LOS | High indicates no linked. low indicates linked. | 4 |
9 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
10 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
11 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
12 | RD- | Receiver Inverted DATA out. AC Coupled. | |
13 | RD+ | Receiver Non-inverted DATA out. AC Coupled. | |
14 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
15 | VCCR | Receiver Power Supply | |
16 | VccT | Transmitter Power Supply | |
17 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |
18 | TD+ | Transmitter Non-Inverted DATA in. AC Coupled. | |
19 | TD- | Transmitter Inverted DATA in. AC Coupled. | |
20 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |
Notes: 1. Circuit ground is connected to chassis ground. 2. PHY disabled on TDIS > 2.0V or open, enabled on TDIS < 0.8V. 3. Should be pulled up with 4.7k - 10k Ohms on host board to a voltage between 2.0 V and 3.6 V. MOD_DEF(0) pulls line low to indicate module is plugged in. 4. LVTTL compatible with a maximum voltage of 2.5V.
Diagram of Host Board Connector Block Pin Numbers and Names. It shows pins 1 through 20 with their corresponding symbols (VeeT, TD-, TD+, VeeT, VccT, VccR, VeeR, RD+, RD-, VeeR) and labels indicating direction ('Towards Bezel', 'Towards ASIC').
Recommended Application Circuit
Figure 2. Recommended Application Circuit. A schematic showing the interconnection between a HOST BOARD, SFP MODULE, ETH PHY, and MCU, detailing power, data, and control signal paths.
Mechanical Specifications
Figure 3. Outline Drawing. Technical drawings of the Copper SFP+ Transceiver with dimensions in millimeters, showing front, side, and top views, highlighting the RJ45 connector.
Test Center
FS.COM transceivers are tested to ensure connectivity and compatibility in our test center before shipped out. FS.COM test center is supported by a variety of mainstream original brand switches and groups of professional staff, helping customers make the most efficient use of our products in their systems, network designs and deployments. The original switches could be found nowhere but at FS.COM test center, e.g., Juniper MX960 & EX 4300 series, Cisco Nexus 9396PX & Cisco ASR 9000 Series, HP 5900 Series & HP 5406R ZL2 V3(J9996A), Arista 7050S-64, Brocade ICX7750-26Q & ICX6610-48, Avaya VSP 7000 MDA 2, etc.
Tested Equipment Examples:
- Cisco ASR 9000 Series(A9K-MPA-1X40GE)
- ARISTA 7050S-64(DCS-7050S-64)
- Juniper MX960
- Brocade ICX 7750-26Q
- Extreme Networks X670V VIM-40G4X
- Mellanox M3601Q
- Dell N4032F
- HP 5406R ZL2 V3(J9996A)
- AVAYA 7024XLS(7002QQ-MDA)
Test Assured Program
FS.COM truly understands the value of compatibility and interoperability to each optics. Every module FS.COM provides must run through programming and an extensive series of platform diagnostic tests to prove its performance and compatibility. In our test center, we care of every detail from staff to facilities—professionally trained staff, advanced test facilities and comprehensive original-brand switches, to ensure our customers to receive the optics with superior quality.
Our smart data system allows effective product management and quality control according to the unique serial number, properly tracing the order, shipment and every part. Our in-house coding facility programs all of our parts to standard OEM specs for compatibility on all major vendors and systems such as Cisco, Juniper, Brocade, HP, Dell, Arista and so on. With a comprehensive line of original-brand switches, we can recreate an environment and test each optics in practical application to ensure quality and distance. The last test assured step to ensure our products to be shipped with perfect package.
Order Information
Part Number | Description |
---|---|
SFP-10GSR-85 | 10GBASE-SR SFP+ 850nm 300m DOM Transceiver |
SFP-10GLRM-31 | 10GBASE-LRM SFP+ 1310nm 220m DOM Transceiver |
SFP-10GLR-31 | 10GBASE-LR SFP+ 1310nm 10km DOM Transceiver |
SFP-10GER-55 | 10GBASE-ER SFP+ 1550nm 40km DOM Transceiver |
SFP-10GZR-55 | 10GBASE-ZR SFP+ 1550nm 80km DOM Transceiver |
SFP-10GZR100-55 | 10GBASE-ZR SFP+ 1550nm 100km DOM Transceiver |
SFP-10GMSR-85 | Dual-Rate 1000BASE-SX and 10GBASE-SR SFP+ 850nm 300m DOM Transceiver |
SFP-10GMLR-31 | Dual-Rate 1000BASE-LX and 10GBASE-LR SFP+ 1310nm 10km DOM Transceiver |
SFP-10G-T-80 | 10GBASE-T SFP+ Copper RJ-45 80m Transceiver |
SFP-10G-T-301 | 10GBASE-T SFP+ Copper RJ-45 30m Industrial Transceiver |
Notes: 1. 10G SFP+ transceiver module is individually tested on corresponding equipment such as Cisco, Arista, Juniper, Dell, Brocade and other brands, and passes the monitoring of FS.COM intelligent quality control system.