SFP-10G-T-80 TEST REPORT (Arista)

ISO 9001 Certified, UCC Compliant, ROHS Compliant, REACH Compliant

CE FC

Content

  1. Test Purpose
  2. Test Result Summary
  3. Test Equipment Used
  4. Test Data
    1. Test Scenario
    2. Test Result

1. Test Purpose

By building test scenarios and simulating the customer's usage environment, FS tests whether the module performance meets the customer's requirements.

2. Test Result Summary

Table 2-1: Test Result Summary
Test Items Test Result
Muti-Version Pass
Connectivity Pass
Module Basic Information Pass

3. Test Equipment Used

Table 3-1: Test Equipment Used
Vendor Device Soft Version/Compatible Brand Serial Number
Arista Switch DCS-7020SR-24C2-F 4.26.4M /
Intel Network Interface Card (NIC) Intel X710-DA2 9.50 0x8000f167 /
FS Optical Transceiver Module SFP-10G-T-80 Arista Compatible A2407030501 A2407030502
FS Server RS7260 / /

4. Test Data

4.1 Test Scenario

Network topology: Arista-DCS-7020SR-24C2-F connected to SFP-10G-T-80, which is then connected to Intel-XXV710-DA2 via FS-RS7260.

Interoperability test scenario: A rack-mounted server setup with multiple network devices.

Test Premise

  1. Confirm the brand, quantity, and placement of the switches to be tested.
  2. Prepare control cables, test software, and optical fiber patch cords. Power on the switches in advance.
  3. Locate the Console port on the switch (often marked as "CON" or with a computer monitor icon). Use a control cable to connect the switch to the computer.
  4. Before connecting the software, confirm the control cable's connection port in the computer's device manager (under Ports COM and LPT).
  5. Open SecureCRT Portable software and enter the quick connection interface.

Connection Settings:

Other configurations can remain at their default values.

Screenshot of the SecureCRT Quick Connect window showing Serial port, COM28, and Baud rate 38400 settings.

Test Method

Test Steps:

  1. Insert the module into the corresponding rate port of the switch. Connect the TX-RX ends with an optical fiber jumper or an MTP self-loop device. Verify module connection. If not connected, check the jumper or switch port configuration.
  2. Log in to the switch using the provided account and password to enter privileged mode.
  3. Execute the appropriate test command based on the switch command configuration table. Review port status (connectivity), connection rate, alarm status, and module basic information to determine if requirements are met.

4.2 Test Result

Switch Information:

Port Status (from 'show interfaces status' command):

Table 4-2: Test Result
Port Name Status Vlan Duplex Speed Type Flags Encapsulation
Et1notconnect1full10GNot Present
Et2notconnect1full10GNot Present
Et3connected1a-fulla-10G10GBASE-T
Et4notconnect1full10GNot Present
Et5connected1a-fulla-10G10GBASE-T
Et6notconnect1full10GNot Present
Et7notconnect1full10GNot Present
Et8notconnect1full10GNot Present
Et9notconnect1full10GNot Present
Et10notconnect1full10GNot Present
Et11notconnect1full10GNot Present
Et12notconnect1full10GNot Present
Et13notconnect1full10GNot Present
Et14notconnect1full10GNot Present
Et15notconnect1full10GNot Present
Et16notconnect1full10GNot Present
Et17notconnect1full10GNot Present
Et18notconnect1full10GNot Present
Et19notconnect1full10GNot Present
Et20notconnect1full10GNot Present
Et21notconnect1full10GNot Present
Et22notconnect1full10GNot Present
Et23notconnect1full10GNot Present
Et24notconnect1full10GNot Present
Et25/1notconnect1full100GNot Present
Et26/1notconnect1full100GNot Present
Ma1notconnectrouted auto auto10/100/1000

2. Verify the NIC port status

Settings for ens4f0:

  • Supported ports: [ FIBRE]
  • Supported link modes: 10000baseT/Full
  • Supported pause frame use: Symmetric Receive-only
  • Supports auto-negotiation: No
  • Supported FEC modes: Not reported
  • Advertised link modes: 10000baseT/Full
  • Advertised pause frame use: No
  • Advertised auto-negotiation: No
  • Advertised FEC modes: Not reported
  • Speed: 10000Mb/s
  • Duplex: Full
  • Auto-negotiation: off
  • Port: Direct Attach Copper
  • PHYAD: 0
  • Transceiver: internal
  • Supports Wake-on: d
  • Wake-on: d
  • Current message level: 0x00000007 (7)
  • drv probe link
  • Link detected: yes

Settings for ens4f1:

  • Supported ports: [ FIBRE]
  • Supported link modes: 10000baseT/Full
  • Supported pause frame use: Symmetric Receive-only
  • Supports auto-negotiation: No
  • Supported FEC modes: Not reported
  • Advertised link modes: 10000baseT/Full
  • Advertised pause frame use: No
  • Advertised auto-negotiation: No
  • Advertised FEC modes: Not reported
  • Speed: 10000Mb/s
  • Duplex: Full
  • Auto-negotiation: off
  • Port: Direct Attach Copper
  • PHYAD: 0
  • Transceiver: internal
  • Supports Wake-on: d
  • Wake-on: d
  • Current message level: 0x00000007 (7)
  • drv probe link
  • Link detected: yes

3. Read the module's basic information from the switch side

DCS-7020SR-24C2-F#show interfaces ethernet 3 transceiver properties

  • Name: Et3
  • Administrative speed: 10G
  • Administrative duplex: full
  • Operational speed: 10G(forced)
  • Operational duplex: full(forced)
  • Media type: 10GBASE-T
  • Speed capabilities: 100M/full,1G/full,10G/full
  • Host error correction: unsupported

DCS-7020SR-24C2-F#show interfaces ethernet 5 transceiver properties

  • Name: Et5
  • Administrative speed: auto
  • Administrative duplex: auto
  • Operational speed: 10G(auto-negotiated)
  • Operational duplex: full(auto-negotiated)
  • Media type: 10GBASE-T
  • Speed capabilities: 100M/full,1G/full,10G/full
  • Host error correction: unsupported

4. Read the module's basic information from the NIC side

[root@RS5220 ~]# ethtool -m ens4f0

  • Identifier: 0x03 (SFP)
  • Extended identifier: 0x04 (GBIC/SFP defined by 2-wire interface ID)
  • Connector: 0x22 (RJ45)
  • Transceiver codes: 0x00 0x00 0x00 0x00 0x00 0x04 0x00 0x00 0x00
  • Transceiver type: Passive Cable
  • Encoding: 0x06 (64B/66B)
  • BR, Nominal: 10300MBd
  • Rate identifier: 0x02 (8/4/2G Rx Rate_Select only)
  • Length (SMF,km): 0km
  • Length (SMF): 0m
  • Length (50um): 0m
  • Length (62.5um): 0m
  • Length (Copper): 80m
  • Length (OM3): 0m
  • Passive Cu cmpince.: 0x00 (unspecified) [SFF-8472 rev10.4 only]
  • Vendor name: FS
  • Vendor OUI: 00:16:21
  • Vendor PN: SFP-10G-T-80
  • Vendor rev: A
  • Option values: 0x00 0x3a
  • Option: RX_LOS implemented
  • Option: TX_FAULT implemented
  • Option: TX_DISABLE implemented
  • Option: RATE_SELECT implemented
  • BR margin, max: 0%
  • BR margin, min: 0%
  • Vendor SN: A2407030502
  • Date code: 240718

[root@RS5220 ~]# ethtool -m ens4f1

  • Identifier: 0x03 (SFP)
  • Extended identifier: 0x04 (GBIC/SFP defined by 2-wire interface ID)
  • Connector: 0x22 (RJ45)
  • Transceiver codes: 0x00 0x00 0x00 0x00 0x00 0x04 0x00 0x00 0x00
  • Transceiver type: Passive Cable
  • Encoding: 0x06 (64B/66B)
  • BR, Nominal: 10300MBd
  • Rate identifier: 0x02 (8/4/2G Rx Rate_Select only)
  • Length (SMF,km): 0km
  • Length (SMF): 0m
  • Length (50um): 0m
  • Length (62.5um): 0m
  • Length (Copper): 80m
  • Length (OM3): 0m
  • Passive Cu cmpince.: 0x00 (unspecified) [SFF-8472 rev10.4 only]
  • Vendor name: FS
  • Vendor OUI: 00:16:21
  • Vendor PN: SFP-10G-T-80
  • Vendor rev: A
  • Option values: 0x00 0x3a
  • Option: RX_LOS implemented
  • Option: TX_FAULT implemented
  • Option: TX_DISABLE implemented
  • Option: RATE_SELECT implemented
  • BR margin, max: 0%
  • BR margin, min: 0%
  • Vendor SN: A2407030501
  • Date code: 240718

Test Conclusion

After completing the above test content, all the test information should be copied and pasted into a TXT document.

Remarks

PDF preview unavailable. Download the PDF instead.

sfp-10g-t-80-test-reportarista

Related Documents

Preview FS SFP-10G-T-30 Transceiver Test Report for Arista Compatibility
This document presents a comprehensive test report for the FS SFP-10G-T-30 transceiver module, detailing its performance and compatibility when used with Arista networking equipment. It outlines the test purpose, methodology, equipment utilized, and the conclusive test results.
Preview FS SFP-10G-T-100 Transceiver Test Report for Cisco Compatibility
Comprehensive test report for the FS SFP-10G-T-100 transceiver, detailing its performance and compatibility with Cisco networking equipment, including test scenarios, equipment, and results.
Preview SFP-10G-PCxxx Transceiver Test Report for Cisco Compatibility
This report details the test results for the FS SFP-10G-PCxxx transceiver, verifying its performance and compatibility with Cisco equipment, including detailed test scenarios, equipment used, and specific port status.
Preview FS SFP-10G-T-80 Transceiver Test Report for Cisco Compatibility
This test report details the performance and compatibility testing of the FS SFP-10G-T-80 transceiver module with Cisco equipment, covering test purpose, results, equipment used, and detailed data.
Preview FS SFP-10G-T-30 Transceiver Test Report for Cisco Compatibility
This document presents the comprehensive test results for the FS SFP-10G-T-30 transceiver, verifying its performance and compatibility with Cisco networking environments. It covers test purpose, equipment used, test scenarios, and detailed results.
Preview FS S5850-24S2Q Switch: Supported Transceivers and Cables
Comprehensive compatibility list for 1G SFP, 10G SFP+, and 40G QSFP+ transceivers, DACs, and AOCs with the FS S5850-24S2Q network switch. Includes detailed datasheets.
Preview FS SFP-GEB-T Transceiver Test Report for Juniper Compatibility
This report details the testing conducted on the FS SFP-GEB-T transceiver to verify its performance and compatibility within a Juniper network environment. It covers test purpose, equipment used, test scenarios, and detailed results including switch and NIC configurations.
Preview FS 10GBASE-T SFP+ Copper RJ-45 30m Transceiver Datasheet
Datasheet for the FS 10GBASE-T SFP+ Copper RJ-45 30m Transceiver, detailing its application, features, product specifications, electrical characteristics, pin descriptions, and testing procedures for network connectivity.