Features
- Meets IEC 62368-1 & IEC 60950-1
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- EMC Standard: EN55032/ EN55024 Class B
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
Safety Standard Approval
Approvals include CULUS LISTED (ITE POWER SUPPLY E190414), TÜV Rheinland, CE, and FCC (Tested to Comply With FCC Standards FOR HOME OR OFFICE USE).
Description
This product is a 50~65 watt AC to DC adapter designed for use in IPC systems, embedded systems, printers, monitors, and POS systems that have high wattage demands. It operates at 90 to 264 VAC input voltage and meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits. It is designed for ITE (Information Technology Equipment) applications.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current | 100Vac, 240Vac / full load ≤ 1.0A |
No load power consumption | 115Vac, 230Vac ≤ 0.075W |
Touch current | 264Vac / 50Hz ≤ 0.25mA |
Output Specifications
Parameter | Details |
---|---|
Output voltage/current | See rating chart |
Total output power | See rating chart |
Over voltage protection | The adapter enters shut down mode when over voltage occurs at the output terminal due to internal fault. Output trip voltage shall not exceed 28V. Normal state is restored by AC reset. |
Short circuit & Over current protection | When an internal or external fault occurs at the output, the power supply shuts down and enters auto-recovery mode. |
Over temperature protection | The power supply enters shut down mode when abnormal thermal rise occurs. Normal state is restored by AC reset. |
Brown-out protection | Shutdown and no damage. |
Environment (Working TEMP.) | 0~70°C (de-rating required above 40°C) |
Environment (Storage TEMP.) | -20~+80°C |
Environment (Working Humidity) | 20~80% RH non-condensing |
Environment (Storage Humidity) | 10~90% RH non-condensing |
Performance Specifications
Parameter | Value |
---|---|
Power factor | N/A |
Efficiency | See rating chart |
Power turn-on time | At 100Vac / full load, output voltage shall remain regulation ≤ 3 seconds. |
Hold-up time | At 100Vac or 240Vac / full load, output voltage shall remain regulation ≥ 10ms. |
Inrush current | At 100Vac, 240Vac / full load, shall be less than the rating of adapter critical components (including rectifiers, fuse, surge, and current limiting device). |
Operating altitude | 5000 meters above sea level. |
Withstand voltage | Between AC input and secondary applied DC 4242V, test time 1 minute, cut-off current shall be less than 10mA. |
MTBF | At 100Vac, 240Vac / full load, 300,000 hours at 25°C (standard SR332). |
EMC Performance
Standard | Compliance |
---|---|
EN55032 | Class B conducted, class B radiated |
FCC | Class B conducted, class B radiated |
VCCI | Class B conducted, class B radiated |
EN61000-3-2 | Meet class A |
EN61000-3-3 | Meet regulation |
EN61000-4-2 | Air discharge: ±8 KV, contact discharge: ±4KV, meet criterion A |
EN61000-4-3 | 80~1000 MHz, 3V/m, 80% AM(1kHz), meet criterion A |
EN61000-4-4 | Impulse: ±1kV applied to L,N, meet criterion A |
EN61000-4-5 | ±1kV applied differential mode, ±2kV applied common mode, meet criterion A |
EN61000-4-6 | 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meet criterion A |
EN61000-4-8 | 50 Hz or 60Hz, 1A/m, meet criterion A |
EN61000-4-11 (Voltage Dips) | >95% reduction for 0.5 period, meet criterion B; 30% reduction for 25 period, meet criterion C |
EN61000-4-11 (Voltage Interruptions) | >95% reduction for 250 period, meet criterion C |
Power De-rating
Power de-rating conditions for 100Vac or 240Vac input:
- 0°C to 40°C: 100% load
- 50°C: 85% load
- 60°C: 70% load
- 70°C: 55% load
Load shall be less than the rating of adapter critical components, following FSP specifications.
Performance Curves
Input Voltage Derating Curve
This graph illustrates the relationship between input voltage and output power. It shows that as the input voltage (X-axis, ranging from 90V to 264V) increases, the percentage of output power (Y-axis) remains at 100% up to approximately 150-180V and then gradually decreases towards 264V.
Output Power Derating Curve
This graph shows the adapter's output power performance relative to ambient temperature. The Y-axis represents the percentage of maximum load, and the X-axis represents temperature (°C) from 0 to 70°C. The curve indicates that the adapter can deliver 100% of its maximum load up to approximately 40°C, after which the output power is de-rated as the temperature increases.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5 Tier 2) |
---|---|---|---|---|---|
FSP050-DHAN3 | 12V | 4.17A | C14 | ≥88% | ≥89% |
FSP060-DHAN3 | 12V | 5A | C14 | ≥88% | ≥89% |
FSP065-DHAN3 | 12V | 5.42A | C14 | ≥88% | ≥89% |
Mechanical and Connector Specifications
The mechanical specifications detail the physical dimensions and connector configuration of the adapter. The diagrams show the overall dimensions of the adapter unit, including length, width, and height, with specific measurements provided (e.g., 1000.0±20.0 mm cable length, 31.5±0.5 mm unit height). The connector specifications describe the DC output plug, including its dimensions, wire gauge (16AWG), wire color (black), and the requirement for a ferrite core on the cable.