CUBOT TAB 65 Tablet RoHS Compliance Test Report
Report Number: LCSA05095004R
Applicant: Shenzhen Huafurui Technology Co., Ltd.
Address: Unit 601-03, 6/F, Block A, Building 1, Ganfeng Technology Building, No. 993 Jiaxian Road, Xiangjiaotang Community, Bantian Street, Longgang District, Shenzhen, P.R. China
Sample Name(s): Tablet
Trade Mark: CUBOT
Tested Model No.: TAB 65
Sample Received Date: May 12, 2025
Testing Period: May 12, 2025 ~ May 16, 2025
Date of Report: May 23, 2025
Testing Location: 901, No.40 Building, Xialang Industrial Zone, Heshuikou Community, Matian Street, Guangming District, Shenzhen, Guangdong, China
Test Request and Conclusion
The tests were conducted as per the client's request. The results indicate that the submitted sample complies with the limits set by the EU RoHS Directive 2011/65/EU with amendment (EU) 2015/863 for the following restricted substances: Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent Chromium (Cr(VI)), Polybrominated Biphenyls (PBBs), Polybrominated Diphenyl Ethers (PBDEs), Dibutyl Phthalate (DBP), Butylbenzyl Phthalate (BBP), Di-2-ethylhexyl Phthalate (DEHP), and Diisobutyl phthalate (DIBP).
Conclusion: PASS
Test Results Summary
The following tables detail the screening results for various components tested against the EU RoHS Directive 2011/65/EU and its amendment directives. The tests were performed using X-ray Fluorescence Spectroscopy (XRF) and Gas Chromatography-Mass Spectrometer (GC-MS) where applicable.
A. EU RoHS Directive 2011/65/EU and its amendment directives (XRF Screening)
Test method: Refer to IEC 62321-3-1:2013 Screening by X-ray Fluorescence Spectroscopy (XRF).
Sample No. | Sample Description | Cd | Pb | Hg | Cr6+ | PBBs | PBDEs | Date of sample submission/ Resubmission |
---|---|---|---|---|---|---|---|---|
1 | Black glass sheets | BL | BL | BL | BL | BL | BL | 2025-05-12 |
2 | Light gray metal case | BL | BL | BL | BL | / | / | 2025-05-12 |
3 | White plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
4 | Black plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
5 | Black adhesive tape | BL | BL | BL | BL | BL | BL | 2025-05-12 |
6 | Silver metal screws | BL | BL | BL | BL | / | / | 2025-05-12 |
7 | Silver metal shrapnel | BL | BL | BL | BL | / | / | 2025-05-12 |
8 | Silver metal flakes | BL | BL | BL | BL | / | / | 2025-05-12 |
9 | Gold-toned metal needles | BL | BL | BL | BL | / | / | 2025-05-12 |
10 | Black plastic thread | BL | BL | BL | BL | BL | BL | 2025-05-12 |
11 | PCB board | BL | BL | BL | BL | BL | BL | 2025-05-12 |
12 | Silver metal case | BL | BL | BL | BL | / | / | 2025-05-12 |
13 | Black plastic case | BL | BL | BL | BL | BL | BL | 2025-05-12 |
14 | White plastic frame | BL | BL | BL | BL | BL | BL | 2025-05-12 |
15 | Silver plastic film | BL | BL | BL | BL | BL | BL | 2025-05-12 |
16 | Silver plastic film | BL | BL | BL | BL | BL | BL | 2025-05-12 |
17 | White plastic film | BL | BL | BL | BL | BL | BL | 2025-05-12 |
18 | White plastic film | BL | BL | BL | BL | BL | BL | 2025-05-12 |
19 | Colorless transparent plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
20 | Yellow plastic lamp beads | BL | BL | BL | BL | BL | BL | 2025-05-12 |
21 | Silver metal case | BL | BL | BL | BL | / | / | 2025-05-12 |
22 | Black plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
23 | Yellow flexible circuit board | BL | BL | BL | BL | BL | BL | 2025-05-12 |
24 | Black plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
25 | Silver metal case | BL | BL | BL | BL | / | / | 2025-05-12 |
26 | Silver plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
27 | Silver metal flakes | BL | BL | BL | BL | / | / | 2025-05-12 |
28 | Silver metal flakes | BL | BL | BL | BL | / | / | 2025-05-12 |
29 | Silver metal flakes | BL | BL | BL | BL | / | / | 2025-05-12 |
30 | Silver metal magnet | BL | BL | BL | BL | / | / | 2025-05-12 |
31 | Copper-colored wire | BL | BL | BL | BL | / | / | 2025-05-12 |
32 | Black plastic thread | BL | BL | BL | BL | BL | BL | 2025-05-12 |
33 | Red plastic thread | BL | BL | BL | BL | BL | BL | 2025-05-12 |
34 | White plastic plug | BL | BL | BL | BL | BL | BL | 2025-05-12 |
35 | White plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
36 | Gold-toned metal needles | BL | BL | BL | BL | / | / | 2025-05-12 |
37 | White plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
38 | Black plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
39 | Silver metal needles | BL | BL | BL | BL | / | / | 2025-05-12 |
40 | Silver metal case | BL | BL | BL | BL | / | / | 2025-05-12 |
41 | Copper-colored metallic film | BL | BL | BL | BL | / | / | 2025-05-12 |
42 | White plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
43 | Black plastic sheet | BL | BL | BL | BL | BL | BL | 2025-05-12 |
44 | Silver metal needles | BL | BL | BL | BL | / | / | 2025-05-12 |
45 | Black IC | BL | BL | BL | BL | BL | BL | 2025-05-12 |
46 | Black IC | BL | BL | BL | BL | BL | BL | 2025-05-12 |
47 | Solder | BL | BL | BL | BL | / | / | 2025-05-12 |
48 | Black IC | BL | BL | BL | BL | BL | BL | 2025-05-12 |
49 | Black IC | BL | BL | BL | BL | BL | BL | 2025-05-12 |
50 | Black IC | BL | BL | BL | BL | BL | BL | 2025-05-12 |
51 | Silver metal flakes | BL | BL | BL | BL | / | / | 2025-05-12 |
52 | PCB board | BL | BL | BL | BL | BL | BL | 2025-05-12 |
53 | White plastic thread | BL | BL | BL | BL | BL | BL | 2025-05-12 |
54 | Silver metal flakes | BL | BL | BL | BL | / | / | 2025-05-12 |
55 | White plastic thread | BL | BL | BL | BL | BL | BL | 2025-05-12 |
B. EU RoHS Directive 2011/65/EU with amendment (EU) 2015/863 on DBP, BBP, DEHP & DIBP Content
Test method: Phthalates(DBP, BBP, DEHP &DIBP) Content: Refer to IEC 62321-8:2017, by solvent extraction and analysis was performed by gas chromatography-mass spectrometer (GC-MS).
1) Phthalates(DBP, BBP, DEHP &DIBP)
Tested Item(s) | MDL (mg/kg) | Test Result(s) (mg/kg) | Limit (mg/kg) |
---|---|---|---|
Dibutyl Phthalate(DBP) Content | 50 | N.D. | 1000 |
Butylbenzyl Phthalate(BBP) Content | 50 | N.D. | 1000 |
Di-(2-ethylhexyl) Phthalate(DEHP) Content | 50 | N.D. | 1000 |
Diisobutyl phthalate(DIBP) Content | 50 | N.D. | 1000 |
2) Phthalates(DBP, BBP, DEHP &DIBP)
Tested Item(s) | MDL (mg/kg) | Test Result(s) (mg/kg) | Limit (mg/kg) |
---|---|---|---|
Dibutyl Phthalate(DBP) Content | 50 | N.D. | 1000 |
Butylbenzyl Phthalate(BBP) Content | 50 | N.D. | 1000 |
Di-(2-ethylhexyl) Phthalate(DEHP) Content | 50 | N.D. | 1000 |
Diisobutyl phthalate(DIBP) Content | 50 | N.D. | 1000 |
3) Phthalates(DBP, BBP, DEHP &DIBP)
Tested Item(s) | MDL (mg/kg) | Test Result(s) (mg/kg) | Limit (mg/kg) |
---|---|---|---|
Dibutyl Phthalate(DBP) Content | 50 | N.D. | 1000 |
Butylbenzyl Phthalate(BBP) Content | 50 | N.D. | 1000 |
Di-(2-ethylhexyl) Phthalate(DEHP) Content | 50 | N.D. | 1000 |
Diisobutyl phthalate(DIBP) Content | 50 | N.D. | 1000 |
4) Phthalates(DBP, BBP, DEHP &DIBP)
Tested Item(s) | MDL (mg/kg) | Test Result(s) (mg/kg) | Limit (mg/kg) |
---|---|---|---|
Dibutyl Phthalate(DBP) Content | 50 | N.D. | 1000 |
Butylbenzyl Phthalate(BBP) Content | 50 | N.D. | 1000 |
Di-(2-ethylhexyl) Phthalate(DEHP) Content | 50 | N.D. | 1000 |
Diisobutyl phthalate(DIBP) Content | 50 | N.D. | 1000 |
Test Process Overview
The report outlines the testing procedures for various substances:
1. Lead (Pb) & Cadmium (Cd): IEC 62321-5:2013
The process involves weighing the sample, adding a digestion reagent, digesting the sample, and then performing analysis using ICP-OES/AAS after making up with deionized water. Filtration is a step in the process.
Diagram Description: A flowchart illustrates the steps: Weigh sample -> Add digestion reagent -> Digest sample -> Dry Ashing/Alkali Fusion/Acid Dissolution -> Residue/Solution -> Filtration -> Make up with deionized water -> Analyzed by ICP-OES/AAS.
2. Mercury (Hg): IEC 62321-4:2013+AMD1:2017 CSV
The process involves weighing the sample into a microwave digestion vessel, adding a digestion reagent, digesting the sample in a microwave digestion oven, and then performing analysis using ICP-OES after making up with deionized water. Filtration is a step in the process.
Diagram Description: A flowchart illustrates the steps: Weigh sample -> Add digestion reagent -> Digest sample in microwave digestion oven -> Dry Ashing/Alkali Fusion/Acid Dissolution -> Residue/Solution -> Filtration -> Make up with deionized water -> Analyzed by ICP-OES.
3. Hexavalent Chromium (Cr(VI))
1) IEC 62321-7-2:2017
The process involves weighing the sample into a vessel, adding a digestion reagent, digesting the sample, cooling and filtering, adjusting the pH of the solution, making up with deionized water, and then analyzing by UV-Vis.
Diagram Description: A flowchart illustrates the steps: Weigh sample -> Add digestion reagent -> Digest the sample -> Cool and filter -> Add the solution -> Adjust the pH value of the solution -> Make up with deionized water -> Analyzed by UV-Vis.
2) IEC 62321-7-1:2015
The process involves taking a portion of the sample, extracting with boiling water, filtering and removing the sample, adding a test solution, adjusting the pH value of the solution, and then analyzing by UV-Vis.
Diagram Description: A flowchart illustrates the steps: Take a portion of the sample -> Extracted with boiling water -> Filter and remove the sample -> Add test solution -> Adjust the pH value of the solution -> Analyzed by UV-Vis.
4. Polybrominated Biphenyls (PBBs) & Polybrominated Diphenyl Ethers (PBDEs): IEC 62321-6:2015
The process involves weighing the sample into a thimble, extracting with organic solvent, concentrating the extract, transferring the extract into a volumetric flask, making up with organic solvent, and then analyzing by GC-MS.
Diagram Description: A flowchart illustrates the steps: Weigh sample -> Extracted with organic solvent -> Concentrate the extract -> Transfer the extract into a volumetric flask -> Make up with organic solvent -> Analyzed by GC-MS.
5. Phthalates (DBP, BBP, DEHP & DIBP): IEC 62321-8:2017
The process involves weighing the sample into a thimble, extracting with organic solvent, concentrating the extract, transferring the extract into a volumetric flask, making up with organic solvent, and then analyzing by GC-MS.
Diagram Description: A flowchart illustrates the steps: Weigh sample -> Extracted with organic solvent -> Concentrate the extract -> Transfer the extract into a volumetric flask -> Make up with organic solvent -> Analyzed by GC-MS.
Sample Photos
The following images show the CUBOT TAB 65 tablet and its accessories:
Photo 1: Front view of the tablet with a ruler for scale.
Photo 2: Rear view of the tablet with a ruler for scale, showing the CUBOT branding and camera module.
Photo 3: Internal components of the tablet, including the battery and motherboard.
Photo 4: Various small components, including screws and connectors.
Photo 5: Small electronic components.
Photo 6: Screws.
Photo 7: A small circuit board.
Photo 8: Screws.
Photo 9: SIM card tray.
Photo 10: Battery.
Photo 11: Battery and small circuit board.
Photo 12: Internal view of the tablet, showing the display assembly.
Photo 13: Display assembly with connecting cables.
Photo 14: A diagram of the display assembly.
Photo 15-19: Various plastic films and sheets.
Photo 20: A flexible circuit board with connectors.
Photo 21-22: Small electronic components.
Photo 23: A flexible circuit board.
Photo 24-25: Small electronic components.
Photo 26-31: Various small electronic components and connectors.
Photo 32-33: Wires and connectors.
Photo 34: A small component with wires.
Photo 35-36: Components.
Photo 37-39: Components.
Photo 40: A circuit board.
Photo 41: A circuit board.
Photo 42-44: Components.
Photo 45-50: Various circuit boards and components.
Photo 51: A circuit board.
Photo 52: A circuit board.
Photo 53: A USB cable.
Photo 54: A USB cable.
Photo 55: Earphones.
Important Notes and Disclaimers
- Note: MDL = Method Detection Limit, N.D. = Not Detected (<MDL), mg/kg = milligram per kilogram = ppm.
- According to customer's requirement, only the appointed materials have been tested.
- The XRF screening report is for reference purposes only. The applicant shall make its/his/her own judgment as to whether the information provided in this XRF screening report is sufficient for its/his/her purposes. The result shown in this XRF screening report will differ based on various factors, including but not limited to, the sample size, thickness, area, surface flatness, equipment parameters and matrix effect (e.g. plastic, rubber, metal, glass, ceramic etc.). Further wet chemical pre-treatment with relevant chemical equipment analysis are required to obtain quantitative data.
- The reading may be different to the actual content in the sample be of non-uniformity composition.
- The maximum permissible limit is quoted from the document RoHS Directive 2011/65/EU with amendment (EU) 2015/863.
- For restricted substances PBBs and PBDEs, the results show the total Br content. The restricted substance was Cr(VI), and the results showed the total Cr content.
- Statement:
- The test report is invalid without the signature of the approver and the special seal for the company's report/ED.
- The company name, address and sample information shown on the report were provided by the applicant who should be responsible for the authenticity which are not verified by LCS.
- The test results in this report are only responsible for the tested samples.
- Without written approval of LCS, this report can't be reproduced except in full.
- In case of any discrepancy between the corresponding Chinese and English contents in the test report, the Chinese version shall prevail.