Domus Line IR Series Infrared Sensors

IR 2.0 Series

IR 2.0 FC FW - Back-door sensor

Description: A back-door infrared limit-switch sensor.

CodeInputOutputPowerWiring INWiring OUT
1759801 (white) - 1759803 (black)12-24VDC12-24VDCmax 36W (12VDC) 72W (24VDC)2500mm Micro12 male, 100mm adapter cable M242500mm Micro12 female, 150mm 9x Micro12 female, 150mm 10x Micro24 female

Visual Description: Image of the IR 2.0 FC FW sensor, a small cylindrical device, shown in white and black, with associated cables. Diagram shows dimensions: Ø14mm, 62mm.

IR 2.0 SD FW - Sensor dimmer switch

Description: An infrared sensor-dimmer switch.

CodeInputOutputPowerWiring INWiring OUT
1760001 (white) - 1760003 (black)12-24VDC12-24VDCmax 36W (12VDC) 72W (24VDC)2500mm Micro12 male, 100mm adapter cable M242500mm Micro12 female, 150mm 9x Micro12 female, 150mm 10x Micro24 female

Visual Description: Image of the IR 2.0 SD FW sensor, similar to the FC model, shown in white and black, with associated cables. Diagram shows dimensions: Ø16mm, Ø14mm, 62mm.

IR ACCESSORIES - 2x IR 2.0 adapter cable*

Description: Adapter cables for IR 2.0 series.

CodeWiring INWiring OUTWiring splitter
1185801/S2x cable 2000mm M24M|M12F2x cable 2000mm M12M|M12F1x cable 200mm 2M12M|1M24F

*See wiring diagram specifications on page 2.

Visual Description: Image of IR 2.0 adapter cables and a wiring splitter.

IR 2.0 Infrared Sensor Overview

The IR 2.0 is an infrared sensor designed for controlling single-colour LED luminaires operating at 12VDC (max 36W) and 24VDC (max 72W). It is factory-set in one of two modes: 'limit-switch' mode (IR 2.0 FC) for installation behind cabinet doors, or 'sensor-dimmer switch' mode (IR 2.0 SD) for under-cabinet installation.

A setup button allows users to change the function between FC and SD modes at any time. The IR 2.0 can be installed recessed into a Ø14mm hole or surface-mounted using the provided adhesive sticker.

In limit-switch mode (IR 2.0 FC), the sensor instantly activates the connected luminaires by switching them ON and OFF as the door it is installed behind opens and closes.

In sensor-dimmer switch mode (IR 2.0 SD), quick hand movements in front of the sensor control the switching ON/Off of the luminaires. Holding a hand steadily in front of the sensor allows for brightness adjustment (10-100%).

The device includes a 2500mm power cable with a Micro12 male connector, a 2500mm output cable with a Micro12 female connector, and a 9-slot Micro12 female distributor. For use with 24VDC single-colour LED devices, a wiring adapter set is provided to configure the device with the Micro24 connection system. Power supply is sold separately.

Key Features:

Installation Notes:

IR 2.0 FC: For optimal operation, the sensor must be installed at least 1mm away from the door panel. Avoid installation near heat sources or electromagnetic fields that could interfere with its function. A preliminary test before installation is recommended.

IR 2.0 SD: Activation for ON/Off is via quick hand movements (max. 50mm distance). Brightness adjustment is maintained by keeping a hand steady. The sensor integrates an automatic switch-off function after approximately 18 hours of continuous operation.

Adapter Wiring Set: The 2x IR 2.0 adapter wiring set (sold separately) enables a system with two sensors to control a luminaire or set of luminaires in a shared mode. For example, two IR 2.0 FC sensors can be used in a wardrobe with double hinged doors, ensuring the light turns ON when either door is opened and OFF only when both doors are closed.

Mode Change: The factory-set mode of the IR 2.0 can be changed from FC to SD (or vice versa) at any time by pressing the setup button located on the back surface. Refer to the instruction manual for detailed guidance.

Initial Setup: Upon first power-up, the IR 2.0 performs a sensitivity self-test, which is saved. Any change in installation requires the luminaire to be reset by cutting the power for at least 10 seconds. Caution: Do not connect the IR 2.0 power unit to a mains electrical circuit switch, as this could unintentionally trigger the self-test function.

Visual Description: Image of a hand activating the IR 2.0 SD sensor. Diagram illustrating a typical wiring setup for IR 2.0 sensors, showing power input, sensor connections, and output to luminaires via a distributor.

CE Mark: CE

IR 3.0 FC Series

IR 3.0 FC - Back-door sensor

Description: An infrared limit-switch sensor for back-door applications.

CodeInputOutputPowerWiring INWiring OUT
F0126000034 (white) F0126000035 (black)12-24VDC12-24VDCmax 36W (12VDC) 72W (24VDC)2500mm Micro24 male2500mm Micro24 female, 150mm 10x Micro24 female

Visual Description: Image of the IR 3.0 FC sensor, a compact unit, shown in white and black, with associated cables. Diagram shows dimensions: Ø14mm, 58mm, 1.5mm.

IR ACCESSORIES - M24|M12 adapter cable set

Description: Adapter cable set for connecting Micro24 to Micro12 systems.

CodeWiring INWiring OUT
4015500/S100mm M24F|M12M150mm 10xM12F|M24M

Visual Description: Image of the M24/M12 adapter cable set.

IR ACCESSORIES - 2x IR 3.0 adapter cable*

Description: Adapter cables for IR 3.0 series.

CodeWiring INWiring OUTWiring splitter
1185801/S2x cable 2000mm M24M|M12F2x cable 2000mm M12M|M12F1x cable 200mm 2M12M|1M24F

*See wiring diagram specifications on page 4.

Visual Description: Image of IR 3.0 adapter cables and a wiring splitter.

IR 3.0 FC Infrared Sensor Overview

The IR 3.0 FC is an infrared 'limit-switch' sensor designed for controlling single-colour LED devices operating at 12VDC (max 36W) and 24VDC (max 72W). It is recommended for installation behind cabinet doors and can be recessed into a Ø14mm hole.

The IR 3.0 FC activates instant switching ON/Off of connected luminaires by opening and closing the door on the back of which the sensor is installed. It features an enhanced detection signal, making it particularly suitable for installation behind doors with low-reflective surfaces.

The appliance is supplied with a 2500mm power cable and Micro24 male connector, a 2500mm output cable and Micro24 female connector, and a distributor with 10 Micro24 female slots. To use the IR 3.0 FC for controlling single-colour LED luminaires at 12VDC (max 36W), an adapter cable set (sold separately) is available to configure the luminaire with the Micro12 connection system. Power supply is not included and must be ordered separately.

Installation Notes:

The detection range (max. approximately 300mm) varies depending on the finish and reflectivity of the door surface. For proper operation, the sensor must be installed at least 2mm away from the door panel. A preliminary test before installation is advisable. Avoid using the IR 3.0 FC near heat sources or electromagnetic fields, which could alter or compromise its functioning.

The IR 3.0 FC integrates an automatic switch-off function that activates after approximately 18 hours of continuous operation.

Adapter Wiring Set: The 2x IR 3.0 adapter wiring set (sold separately) allows for a system with two sensors to control a luminaire or set of luminaires in a shared mode. For example, two IR 3.0 FC sensors can be installed inside a wardrobe with double hinged doors, enabling the light to turn ON when either door is opened, and to turn OFF only when both doors are closed.

Initial Setup: Upon first power-up, the IR 3.0 performs a sensitivity self-test, which is saved. Any change in installation requires the luminaire to be reset by cutting the power for at least 10 seconds. Caution: Do not connect the IR 3.0 power unit to a mains electrical circuit switch, as this could unintentionally trigger the self-test function.

Visual Description: Diagram illustrating a typical wiring setup for IR 3.0 FC sensors, showing power input, sensor connections, and output to luminaires via a distributor.

IR 4.0 Series

IR 4.0 FC - Back-door sensor

Description: An infrared limit-switch sensor for back-door applications.

CodeInputOutputPowerWiring INWiring OUT
F012600004312-24VDC12-24VDCmax 36W (12VDC) 72W (24VDC)2500mm Micro24 male2500mm Micro24 female, 150mm 10x Micro24 female

Visual Description: Image of the IR 4.0 FC sensor, a compact unit, shown in black, with associated cables. Diagram shows dimensions: Ø12mm, 65mm, 1mm.

IR 4.0 SD - Sensor-dimmer switch

Description: An infrared sensor-dimmer switch.

CodeInputOutputPowerWiring INWiring OUT
F012600004212-24VDC12-24VDCmax 36W (12VDC) 72W (24VDC)2500mm Micro24 male2500mm Micro24 female, 150mm 10x Micro24 female

Visual Description: Image of the IR 4.0 SD sensor, similar to the FC model, shown in black, with associated cables. Diagram shows dimensions: Ø12mm, 65mm, 1mm.

IR ACCESSORIES - M24|M12 adapter cable set

Description: Adapter cable set for connecting Micro24 to Micro12 systems.

CodeWiring INWiring OUT
4015500100mm M24F|M12M150mm 10xM12F|M24M

Visual Description: Image of the M24/M12 adapter cable set.

IR 4.0 Infrared Sensor Overview

The IR 4.0 is an infrared sensor for controlling single-colour LED luminaires at 12VDC (max 36W) and 24VDC (max 72W). It is factory-set in either 'limit-switch' mode (IR 4.0 FC) for installation behind a cabinet door, or 'sensor-dimmer switch' mode (IR 4.0 SD) for under-cabinet installation.

A setup button allows the function of both models to be changed at any time, from FC to SD and vice versa. The IR 4.0 can be recessed into a Ø10mm hole.

In limit-switch mode (IR 4.0 FC), the sensor activates soft switching ON and Off of the luminaires connected to the output cable by opening and closing the door on the back of which the sensor is installed.

In sensor-dimmer switch mode (IR 4.0 SD), quick hand movements in front of the sensor control the switching ON/Off (always in soft mode). Holding a hand steadily in front of the sensor adjusts the brightness (10-100%).

The device is supplied with a 2500mm power cable and Micro24 male connector, a 2500mm output cable and Micro24 female connector, and a distributor with 10 Micro24 female slots. To use the IR 4.0 for controlling single-colour LED luminaires at 12VDC (max 36W), an adapter cable set is available that configures the luminaire with the Micro12 connection system. Power supply is not included and must be ordered separately.

Installation Notes:

IR 4.0 FC: Activates soft-on and soft-off switching with a maximum fade time of 2.5 seconds when the door opens or closes. The detection range (max. approximately 250mm) varies by surface reflectivity. It can also be installed flush with the door without compromising functionality. A preliminary test before installation is advisable. Avoid using the IR 4.0 near heat sources or electromagnetic fields.

IR 4.0 SD: Switches ON/Off and adjusts brightness (10-100%) with soft-on/soft-off mode and a fade time of up to 1 second. Activation is via quick hand movements (max. 50mm distance). Brightness adjustment is stored in memory. Integrates an automatic switch-off function after approximately 18 hours of continuous operation.

Mode Change: The factory-set mode of the IR 4.0 can be changed from FC to SD (or vice versa) at any time by pressing the setup button located on the back surface. Refer to the instruction manual for detailed guidance.

Initial Setup: Upon first power-up, the IR 4.0 performs a sensitivity self-test, which is saved. Any change in installation requires the luminaire to be reset by cutting the power for at least 10 seconds. Caution: Do not connect the IR 4.0 power unit to a mains electrical circuit switch, as this could unintentionally trigger the self-test function.

Visual Description: Images of black and white IR 4.0 sensors.

CE Mark: CE

IR 4.0 SP Series

IR 4.0 SP FC - Back-door sensor

Description: An infrared limit-switch sensor for back-door applications.

CodeInputOutputPowerWiring INWiring OUT
F0126000084 (black) F0126000085 (white)12-24VDC12-24VDCmax 36W (12VDC) 72W (24VDC)2500mm Micro24 male, 2500mm Micro24 female150mm 10x Micro24 female

Visual Description: Image of the IR 4.0 SP FC sensor, a compact unit, shown in black and white, with associated cables. Diagram shows dimensions: 14mm, 76mm.

IR 4.0 SP SD - Sensor dimmer switch

Description: An infrared sensor-dimmer switch.

CodeInputOutputPowerWiring INWiring OUT
F0126000103 (black) F0126000104 (white)12-24VDC12-24VDCmax 36W (12VDC) 72W (24VDC)2500mm Micro24 male, 2500mm Micro24 female150mm 10x Micro24 female

Visual Description: Image of the IR 4.0 SP SD sensor, similar to the FC model, shown in black and white, with associated cables. Diagram shows dimensions: 14mm, 76mm.

IR ACCESSORI - Spacer SP for IR 4.0

Description: Spacers for IR 4.0 sensors.

CodeModelFinish
F0007000039SPACER SP IR 4.0black
F0007000040SPACER SP IR 4.0white

Visual Description: Image of SP spacers for IR 4.0 sensors, shown in black and white.

IR 4.0 SP Infrared Sensor Overview

The IR 4.0 SP is an infrared sensor for controlling single-colour LED luminaires at 12VDC (max 36W) and 24VDC (max 72W). It is factory-set in either 'limit-switch' mode (IR 4.0 FC) for installation behind a cabinet door, or 'sensor-dimmer switch' mode (IR 4.0 SD) for under-cabinet installation. It can also be surface-mounted under a shelf.

A setup button allows the function of both models to be changed at any time, from FC to SD and vice versa.

In limit-switch mode (IR 4.0 SP FC), the sensor activates soft switching ON/Off of the luminaires connected to the output cable by opening and closing the door on the back of which the sensor is installed.

In sensor-dimmer switch mode (IR 4.0 SP SD), quick hand movements in front of the sensor control the switching ON/Off (always in soft mode). Holding a hand steadily in front of the sensor adjusts the brightness (10-100%).

The device is supplied with a 2500mm power cable and Micro24 male connector, a 2500mm output cable and Micro24 female connector, and a distributor with 10 Micro24 female slots. To use the IR 4.0 SP for controlling single-colour LED luminaires at 12VDC (max 36W), an adapter cable set is available that configures the luminaire with the Micro12 connection system. Power supply is not included and must be ordered separately.

Installation Notes:

IR 4.0 SP FC: Activates soft-on and soft-off switching with a maximum fade time of 2.5 seconds when the door opens or closes. The detection range (max. approximately 250mm) varies by surface reflectivity. It can also be installed flush with the door without compromising functionality. A preliminary test before installation is advisable. Avoid using the IR 4.0 SP near heat sources or electromagnetic fields.

IR 4.0 SP SD: Switches ON/Off and adjusts brightness (10-100%) with soft-on/soft-off mode and a fade time of up to 1 second. Activation is via quick hand movements (max. 50mm distance). Brightness adjustment is stored in memory. Integrates an automatic switch-off function after approximately 18 hours of continuous operation.

Mode Change: The factory-set mode of the IR 4.0 SP can be changed from FC to SD (or vice versa) at any time by pressing the setup button located on the back surface. Refer to the instruction manual for detailed guidance.

Initial Setup: Upon first power-up, the IR 4.0 SP performs a sensitivity self-test, which is saved. Any change in installation requires the luminaire to be reset by cutting the power for at least 10 seconds. Caution: Do not connect the IR 4.0 SP power unit to a mains electrical circuit switch, as this could unintentionally trigger the self-test function.

Visual Description: Images of black and white IR 4.0 SP sensors.

CE Mark: CE

PDF preview unavailable. Download the PDF instead.

IR catalogue sheet EN r1-1 Adobe PDF Library 17.0 Adobe InDesign 20.5 (Macintosh)

Related Documents

Preview Domus Line IR Sensor Series: Installation and Operation Guide
Installation and operation guide for Domus Line IR 2.0, IR 3.0, and IR 4.0 sensor series. Covers technical specifications, wiring diagrams, setup procedures, material options, and operational modes for LED cabinet lighting.
Preview Domus Line X-Driver D-M LED Drivers and Accessories
Comprehensive guide to Domus Line X-Driver D-M LED drivers, including technical specifications, features, and compatible accessories like sensors and remote controls. Learn about smart lighting control via Bluetooth and Wi-Fi.
Preview Domus Line MINI POLY ECB Lighting Control System: Installation and Operation Guide
Comprehensive guide for Domus Line's MINI POLY ECB lighting control system, covering IR-1, TOUCH-1, PIR-1, PIR-2, and D-MWA sensors. Includes installation diagrams, operating instructions, and technical specifications.
Preview Domus Line X-DRIVER TW 2.0: Tunable White LED Lighting Control System
Detailed information on the Domus Line X-DRIVER TW 2.0, an all-in-one LED converter for Human Centric Lighting systems. Features include multiple power outputs (15W, 30W, 60W), multinet 110-240Vac input, and compatibility with various control modules (PIR, IR, RF, Bluetooth, Wi-Fi) for smart lighting management.
Preview Domus Line IR WI-XD Installation Manual and Technical Guide
Comprehensive installation manual and technical guide for the Domus Line IR WI-XD lighting control sensor, covering setup, operation modes, battery safety, and compliance information.
Preview Domus Line X-DRIVER LED Lighting System
Comprehensive guide to the Domus Line X-DRIVER system, featuring LED drivers, control modules, sensors, and kinetic switches for smart lighting solutions. Explore features, specifications, and applications for various lighting control needs.
Preview Domus Line PIR 2.0 Motion Sensor Control Unit - Technical Overview
Detailed technical overview of the Domus Line PIR 2.0 motion sensor control unit, including specifications, accessories, operation, and installation guidelines for LED lighting systems.
Preview Domus Line MINI POLY ECB & D-MWA ECB Control Units
Discover the Domus Line MINI POLY ECB and MINI POLY D-MWA ECB control units, versatile multi-sensor solutions for single-colour and dual-colour LED lighting. Learn about their features, including limit switch and sensor-dimmer modes, and compatible sensors like IR-1, TD-1, PIR-1, and PIR-2.