Meling Biomedical Combined Refrigerator and Freezer Operation Manual

Applicable Product Models

The following product models are applicable:

1. Application Notes

Thank you for choosing Meling Biomedical products. For your safe and convenient use and reasonable maintenance of the equipment, please read this Operation Manual carefully before use and keep it properly for reference.

The equipment operator may copy some chapters of this operation manual for internal use, such as instructing users on how to deal with emergencies. These chapters are clearly marked in the manual's catalog.

Meling Biomedical is not obligated or responsible for any instrument damage caused by the user's failure to use the equipment according to the instructions or the method specified by the manufacturer.

Due to the rapid improvement of Meling Biomedical products, the functions described in this Manual may be inconsistent with the products you purchased. Please refer to the physical functions.

Please read the Attention and Safety Precautions in Section 2 carefully.

Warning:

Tips:

2. Safety Instructions

When using this product for the first time, please pay attention to the meaning of the following warning signs and carefully read the safety precautions, so that you can use this equipment safely and correctly.

Warning! Failure to observe the precautions may result in serious personal injury or death. Attention! Failure to observe the precautions may result in personal injury or equipment failure and related property losses.
Must be grounded Risk of Explosion This sign indicates the risk of explosion when using volatile and explosive chemicals.
Do not place it obliquely Avoid direct sunlight
Beware of electric shock. Beware of low temperature
Beware of fire. Warning: flammable material This equipment is a precision instrument
Warning: crushing of hands.
Warning: Risk of fire/flammable materials.
Warning: Failure to observe the precautions may result in serious personal injury or death.

3. Precautions in Use

4. Product Installation

4.1 Installation Environment

4.2 Installation Site

In order to operate the equipment normally and obtain the best performance level, the installation site of the equipment shall meet the following requirements:

4.3 Preparation Before Use

4.4 First Power-on

When using the equipment for the first time, please follow these steps:

  1. After the equipment is placed, leveled, and cleaned, it shall stand for more than 24 hours, and then be powered on to ensure the normal operation of the equipment.
  2. Under no-load condition, connect the power cord to a special outlet with appropriate specifications.
  3. After powering on, turn on the power switch of the equipment.
  4. Check whether the operating temperature of the equipment reaches the required value, observe the normal start and stop of the equipment for more than 24 hours, and put a small amount of items in the equipment after confirming the normal performance.
  5. Please store items in batches, with the items not exceeding 1/3 of the cabinet body volume each time. Ensure that the equipment is running properly after shutdown for more than 12 hours before putting in the next batch of items.
  6. Try not to open the door during cooling, otherwise the temperature will rise.

4.5 Operation after Power Failure

  1. The equipment has a memory function for the set value. When the power is restored after power failure, the equipment will continue to operate before power failure.
  2. Once the equipment is powered off, it requires 5 minutes before it can be switched on again, so as to avoid damaging the compressor.
  3. Meling Biomedical guarantees the normal operation of this equipment under certain conditions, but is not responsible for any loss or damage of stored items after power failure.

Notes:

5. Component Composition

The product consists of cabinet body, door body, refrigeration system, and control system.

YCD-EL300

YCD-EL289 (Reference for YCD-FL519)

YCD-EL450 (Reference for YCD-EL450 and YCD-FL450)

Specifications:

Note: Due to product improvements and model differences, the actual products may differ from the diagrams. Please refer to the actual products. The diagrams are for functional parts description only.

6. Operating Instructions

6.1 Function Introduction

The series of products include two kinds of control systems with different adjustment methods. Please select the corresponding adjustment method according to the control system type of the preservation box you have purchased.

Type A control panel (applicable to YCD-EL300)

1. Function description of Type A control panel:

2. Function setting of Type A control panel:

  1. After powering on, the equipment can enter the working state.
  2. User parameter settings: In measurement and control state, press the SET key, and the digital tube will flash and display the temperature value currently set, entering the user parameter settings state. Press or key to adjust the set temperature. Long press or key to make the set temperature value increase or decrease successively. Press SET key or no operation within 5 seconds to save parameters and return to measurement and control state.
  3. On and Off: In the measurement and control state, press the Power Off key for 3 seconds to turn off the display and output control, and enter the power-off state (you can turn off the refrigerator chamber or freezer chamber separately). Press any key to turn on the display and output control, and return to the measurement and control state.
  4. Parameter display:
Alarm Code Default Description
E1 Refrigerator sensor failure
E2 Freezer sensor failure
dA Door ajar alarm

Note: In case of high and low temperature alarm, the buzzer will sound and the digital tube will flash to display the current temperature. In data failure, sensor failure, high and low temperature alarm, when the controller is in power-on state, the buzzer will sound and will become mute when pressing any key. After all failures are recovered or 30 minutes later, the mute will fail.

Type B control panel

1. Function description of Type B control panel:

2. Function setting of Type B control panel:

  1. After powering on, the machine will enter the working state.
  2. User parameter settings: Unlock: Under normal operation, press SET/MUTE and key for 3 seconds at the same time, and the digital tube in the upper chamber will display "PS1" and the digital tube in the lower chamber will display the parameter code "0000". Press SET/MUTE to enter the password "0005" (when entering the user menu password, enter "0099" to restore the key lock password to the default "0005."), and unlock it. Unlock and press SET/MUTE key for 3s, and the digital tube will display the parameter code "PS1" and enter the setting and adjustment parameters.
  3. Use or to scroll the parameters.
  4. Use or to increase or decrease the value.
  5. Use SET/MUTE to temporarily store the modified values and return to the display parameters.
  6. If other parameters are modified, repeat steps 1-3.
  7. Press SET/MUTE for more than 3s, save the modified parameters and return to the display parameter category.
  8. Press SET/MUTE for more than 3s, or press no key in 60 seconds to exit the parameter setting program.
No. Menu item Menu description Set range Default Unit Remarks
1 b1 Set logger module time - year 10~50 / Hardware version
2 b2 Set logger module time - month 1~12 / Software version
3 Set1 Refrigerator temperature setting 0.0~10.0 5.0
4 H01 Set value of high temperature alarm set+H; when H = 0, High temp alarm is disabled; When the alarm is over high temp alarm set, H01 will be displayed on the controller 0.0~10.0 5.0
5 L01 Set value of low temperature alarm set-L; when L = 0, low temp alarm is disabled; when the alarm is below low temp alarm set, L01 will be displayed on the controller 0.0~10.0 5.0
6 Set2 Freezer temperature setting YCD-EL series: -10~-26
YCD-FL series: -10~-40
YCD-EL series: -20
YCD-FL series: -40
7 H02 Set value of high temperature alarm set+H; when H02 = 0, High temp alarm is disabled; When the alarm is over high temp alarm set, H02 will be displayed on the controller 0.0~10.0 5.0
8 L02 Set value of low temperature alarm set-L; when L02 = 0, low temp alarm is disabled; when the alarm is below low temp alarm set, L02 will be displayed on the controller 0.0~10.0 5.0
9 Pt Print interval 0~240 min 20 min
10 tH1 Upper limit of ambient temperature alarm 20.0~50.0°C 40 °C
11 P1 Automatic heating modes 1. Set to 4 when the door is with condensation.
2. After the compressor is running. Heater on; When the compressor stops, the heater is delayed for 1 minute for turn-off.
3. When the humidity in the cabinet is more than 80%, the door heating is on, and when the humidity in the cabinet is moderately less than 60%, the door heating is off.
4. Door heating is always on.
5. Door heating is always off.
12 PS1 User menu password settings 0000~9999 0005
13 MAX The highest temperature since last clearance - -
14 NIN The lowest temperature since last clearance - -
15 CLR Clearance of the Max and Min temperature records - -

Quick setting of time after power on:

After the power-on self-test on the display board is completed, the quick setting menu is displayed.

Menu item Menu Menu description Set range Default Unit
n Set logger module time - year 10~50 /
y Set logger module time - month 1~12 /
r Set logger module time - day 01~31 /
S Set logger module time - hour 00~23 /
F Set logger module time - minute 00~59 /
Pt Print interval 0~240 20 min
SCY Temperature data recording period 0~240 10 min

If there is no operation for 60 seconds under the quick setting menu, it will automatically exit the quick setting menu and return to normal display.

4. Alarm display

Alarm Code Default Description
H01 Upper refrigerator chamber high temperature alarm
L01 Upper refrigerator chamber low temperature alarm
H02 Lower freezer chamber high temperature alarm
L02 Lower freezer chamber low temperature alarm
H03 High ambient temperature alarm
door Door opening alarm
PF Power failure alarm
bL Low battery alarm
Er The recorder is not connected
LoF The recorder is not started
EE Communication failure

6.2 Optional function

1. Printer

The printer has been installed with a paper roll at the factory. If the paper roll is used up after a long period of use, you can buy the same paper roll (size: thermal paper, paper width: 57.5±0.5mm, the outer diameter of the reel: not greater than 40mm, i.e., RM57*40 back-roll paper).

Description of printer panel:

Install the paper roll:

Press the open button 1, open the cover, install the paper roll, close the cover plate and allow the head of the roll paper to slightly extend out of the cover plate.

2. Remote alarm terminal, RS485 interface and network interface

Remote alarm terminal, RS485 interface and network interface are installed in the lower part of the back of the freezer body.

Note: These configurations are standard for some models.

7. Defrost, Discontinuation and Maintenance

Warning:

7.1 Equipment Maintenance

Defrosting: The equipment will automatically defrost during operation, which is convenient to use.

Cleaning and maintenance: The equipment should be cleaned and maintained regularly (for safety, please unplug the power plug), and the inner and outer surfaces of the cabinet body should be wiped with a warm, damp soft cloth.

Note:

7.2 Equipment Discontinuation

Deactivation: If the equipment is stored in an unsupervised area for a long time and not used, the power supply should be cut off, and the inner and outer surfaces of the cabinet body should be cleaned with a warm, damp soft cloth, aired, and sealed. The equipment must be locked to ensure that children cannot open the freezer door.

Scrapping: When the equipment reaches the end of its service life, it should be scrapped and must be handed over to a qualified professional recycling agency for disposal per local regulations. Non-professionals are not allowed to disassemble and break down the equipment without authorization. The scrapped equipment should be placed in a designated area inaccessible to children to avoid danger.

8. Troubleshooting and Maintenance Services

Any product may fail. Please observe the operation of the equipment in time during use. If there is any abnormality, please check and handle it according to the following table first. If the abnormality can't be changed, please inform our service center in time, and Meling Biomedical will serve you wholeheartedly to avoid losses.

Fan motor replacement time: about 6 years; Service life of the product: 10 years.

Problems Causes and solutions
Equipment does not work Please make sure that the outlet is energized.
Please make sure the power plug is plugged in, not loose.
Please make sure the power fuse is not disconnected.
Please make sure the supply voltage is appropriate, not too low or too high.
Compressor is not running Please make sure that the temperature is set correctly.
Please check whether the temperature inside the cabinet is too low.
The temperature does not reach the set value Please make sure that the door is closed tightly and don't open it too many times during a short time.
Please don't put too many items in at one time.
Please make sure that the ambient temperature is not too high.
High noise Please make sure that the cabinet is placed on a flat ground.
Please make sure that the cabinet does not contact the wall.
Condensation on cabinet body surface In rainy and humid seasons, door condensation is normal, and it shall be wiped off with a dry cloth.
Abnormal smell Equipment needs to be cleaned.
Items with heavy smell are not packed.
The door is not closed properly, and the cool air leaks After the equipment is used for a period of time, the door seal becomes hard and deformed.
Maintenance method: Blow the deformed part of the hot seal with a blower to soften it, and then dose and compress it after the door seal becomes soft.
The alarm lamp flashes and the buzzer is triggered Please make sure that it will be automatically eliminated after running for a period of time when the items are just put in and the temperature has been stable.
Please make sure that the alarm is generated for door opening since the door is not locked.
Please make sure that it will be automatically eliminated after running for a period of time because of low battery.
Please make sure that the temperature does not exceed the standard.
Lighting damage (refrigeration equipment) Please call the after-sales telephone and contact after-sales service personnel of Meling Biomedical for replacement. Please do not replace the parts by yourself.

The following conditions are not faults:

  1. When the compressor starts and stops, the equipment parts will make a slight impact sound.
  2. When overheated items are put in after the door is opened, high temperature alarm and high humidity alarm will be triggered in the control system (if this function is available, please refer to the alarm display table).
    Solution: Put the items into the equipment after they are naturally cooled. Put the items in small quantities in batches, and do not put too much at a time. After the system runs stably, the high temperature alarm and low temperature alarm will be released automatically.
  3. Slight sound of water caused by refrigerant flowing in the pipeline.

Notes:

9. Specifications

Model Ambient temperature Climate type Refrigerant and loading amount (Rated) Voltage (V~) Rated frequency (Hz) Temp Range (°C) (Rated) Volume (L) current (A) Net Weight (kg) Exterior Dimensions (DxWxH) (mm)
YCD-EL300 (Spraying aluminum liner) 16~32°C N Refrigerant:R600a/20g
Freezer:R600a/60g
220-240 60 Refrigerant:2~8°C
Freezer:-10~-26°C
300 1.76 95 640×700×1876
YCD-EL300 (HIPS) 16~32°C N Refrigerant:R600a/20g
Freezer:R600a/60g
220-240 60 Refrigerant:2~8°C
Freezer:-10~-26°C
300 1.76 87 640×700×1842
YCD-EL300 (Stainless steel liner) 16~32°C N Refrigerant:R600a/20g
Freezer:R600a/60g
220-240 60 Refrigerant:2~8°C
Freezer:-10~-26°C
300 1.76 104 640×700×1876
YCD-EL450 (Spraying aluminum liner) 16~32°C N Refrigerant:R600a/28g
Freezer:R600a/65g
220-240 60 Refrigerant:2~8°C
Freezer:-10~-26°C
450 1.84 144 735×810×1960
YCD-EL450 (HIPS) 16-32°C N Refrigerant:R600a/28g
Freezer:R600a/65g
220-240 60 Refrigerant:2~8°C
Freezer:-10~-26°C
450 1.84 127 735×810×1960
YCD-EL450 (Stainless steel liner) 16-32°C N Refrigerant:R600a/28g
Freezer:R600a/65g
220-240 60 Refrigerant:2~8°C
Freezer:-10~-26°C
450 1.84 162 735×810×1960
YCD-FL289 (Stainless steel liner) 16~32°C N Refrigerant:R134a/45g
Freezer:R290/42g
110 60 Refrigerant:2~8°C
Freezer:-10~-40°C
289 5.52 143 640×700×1845
YCD-EL300 (Spraying aluminum liner) 16~32°C N Refrigerant:R600a/22g
Freezer:R600a/60g
110 60 Refrigerant:2~8°C
Freezer:-10~-26°C
300 3.17 95 640×700×1876
YCD-FL450 (Spraying aluminum liner) 16~32°C N Refrigerant:R290/30g
Freezer:R290/42g
110 60 Refrigerant:2~8°C
Freezer:-10~-40°C
450 4.41 144 735×810×1960
YCD-EL450 (Spraying aluminum liner) 16~32°C N Refrigerant:R600a/28g
Freezer:R600a/50g
110 60 Refrigerant:2~8°C
Freezer:-10~-26°C
450 3 144 735×810×1960
YCD-FL519 (Stainless steel liner) 16~32°C N Refrigerant:R600a/26g
Freezer:R290a/65g
220-240 50 Refrigerant:2~8°C
Freezer:-10~-40°C
519 3.57 186 740×910×1972

* The foaming agent of this product is cyclopentane.

10. Accessories

Name Operation Manual Qualified Certificate Key Defrosting shovel
Number 1 1 2 1

YCD-FL289, YCD-FL519 do not have keys.

* The specific accessories shall be subject to the physical objects received.

Models: YCD-FL289, YCD-EL300, YCD-EL450, YCD-FL450, YCD-FL519, YCD Series Combined Refrigerator and Freezer, YCD Series, YCD Series Refrigerator and Freezer, Combined Refrigerator and Freezer, Refrigerator and Freezer, Refrigerator, Freezer

File Info : application/pdf, 22 Pages, 1.83MB

PDF preview unavailable. Download the PDF instead.

148522-ycd-el450-combined-refrigerator-freezer-meling-biomedical-operation-manual

References

Corel PDF Engine Version 21.2.0.706

Related Documents

Preview MELING BIOMEDICAL Combined Refrigerator and Freezer User Manual
This user manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of MELING BIOMEDICAL Combined Refrigerators and Freezers. It covers safety precautions, product components, operating procedures, troubleshooting, and specifications for various models including YCD-FL289, YCD-EL300, YCD-EL450, YCD-FL450, and YCD-FL519.
Preview Combined Refrigerator and Freezer User Manual
User manual for the MELING BIOMEDICAL Combined Refrigerator and Freezer, detailing installation, operation, maintenance, and troubleshooting for models YCD-FL289, YCD-EL300, YCD-EL450, YCD-FL450, and YCD-FL519.
Preview MELING BIOMEDICAL Combined Refrigerator and Freezer Operation Manual
This operation manual provides comprehensive instructions for the safe and effective use of MELING BIOMEDICAL Combined Refrigerators and Freezers. It covers installation, operation, maintenance, and troubleshooting for models including YCD-FL289, YCD-EL300, YCD-EL450, YCD-FL450, and YCD-FL519.
Preview Meling Biomedical Combined Refrigerator and Freezer Operation Manual
Comprehensive operation manual for Meling Biomedical Combined Refrigerators and Freezers, covering installation, operation, maintenance, troubleshooting, and specifications for models YCD-FL289, YCD-EL300, YCD-EL450, YCD-FL450, and YCD-FL519.
Preview MELING BIOMEDICAL Combined Refrigerator and Freezer Operation Manual
This operation manual provides detailed instructions for the safe and effective use, maintenance, and troubleshooting of MELING BIOMEDICAL Combined Refrigerators and Freezers. It covers product installation, operating instructions, component composition, specifications, and safety precautions for models such as YCD-FL289, YCD-EL300, YCD-EL450, YCD-FL450, and YCD-FL519.
Preview Meling Biomedical Product Catalogue: Freezers and Refrigerators
Comprehensive product catalogue from Meling Biomedical featuring a wide range of ultra-low temperature freezers, biomedical freezers, combined refrigerator-freezers, and pharmacy refrigerators. Details include structure, control systems, refrigeration systems, and technical specifications.
Preview Meling Biomedical Product Catalogue: Freezers and Refrigerators
A comprehensive product catalogue from Meling Biomedical showcasing their range of ultra-low temperature freezers, biomedical freezers, combined refrigerator-freezers, and pharmacy refrigerators. Includes detailed specifications, structure, control, and refrigeration systems.
Preview Meling Biomedical Product Catalogue - Refrigeration Solutions
Explore the comprehensive product catalogue from Meling Biomedical, featuring a wide range of ultra-low temperature freezers, biomedical freezers, and pharmacy refrigerators designed for scientific and medical applications. Discover innovative features, detailed specifications, and reliable performance.